2.b Hydraulic Culvert

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

2.

b
HYDRAULIC CALCULATION OF HUME PIPE CULVERT
DEVELOPMENT OF ROAD FROM AMAR FACTORY TO JAIL ROAD
AT CHAINAGE 0+55
1 Data
Structure Category ,= HPC
Catchment Area ,= 0.05 sq.km
,= 5 HEC
No. of Rows ,= 1 Nos.
Pipe Diameter ,= 1.2 m
Camber/Super Elevation ,= 2.50 %
Total Lenth Of Culvert ,= 12.5 m
Wearing Coat ,= 0.065 m
Provided FRL ,= 100.042 m

2 Discharge Based On Dicken's Method


Dicken's Discharge (Q) ,= C x M^(3/4) (Ref: Pg. 7-SP: 13-2004)
Normal Annual Rainfall ,= 112 Ref:- Flood Estimation Repor By CWC
Where C ,= 17
,= 1.798
Say ,= 1.798 m3/sec

3 Discharge Based On Rational Method


1. Catchment Area (A) ,= 0.05 sq.km
2. Length Of Longest Stream (L) ,= 0.5 Hec
3. Elevation Diffrence (H) ,= 1.4 m
4. Max. Rainfall Intensity (F) ,= 38.08 mm Ref:- Flood Estimation Repor By CWC
5. Duration Of Storm (T) ,= 24 hr

One Hour Rainfall Intensity I₀ ,= F x (T+1)/2T (Ref: Pg. 15-SP:13-2004)


,= 19.83333333 cm

Time Of Concentration Tc (Ref: Pg. 12-SP:13-2004)


Tc ,= (0.87 x L^3/H)^0.385
,= 0.556

Critical Intensity Of Rainfall in cm Per Hr Ic (Ref: Pg. 12-SP:13-2004)


Ic ,= I₀ x 2/(Tc+1)
,= 25.5 cm/hr

Chracterstics of the catchment area ,= 6 Loam , Lightly Cultivated or Covered


Coeficient Runoff (P) ,= 0.4 (Ref: Table 4.1-SP13-2004)
Fraction For C.A. in Hec 1.0 ,= 0.996 (Ref: Fig. 4.2-SP14-2004)
(Ref: Pg. 13-SP13-2004)
Discharge Q ,= 0.028 x P x f x A x Ic
Q ,= 1.42 Cumec

Pipe Configuration
No Of Rows ,= 1 Nos.
Pipe of Diameter ,= 1.2 m

C/S Area of Pipe [A] ,= No of rows x [(Π/4) x D x D]


,= 1.131 Sqm
Perimeter of [P] ,= No of rows x [Π x D]
,= 3.770
Hydraulic Mean Radius [R] ,= [A] / [P]
0.300

Entry Loss Coeficient (Ke) ,= 1.107 x (R^0.5)


,= 0.606 (Table-19.1 Pg IRC-SP-13)

Friction Loss Coeficient [Kf] ,= 0.00394 x L / R^1.2


,= 0.209

Head [H] ,= 0.400

Coveyance factor [λ] ,= A/(1+Ke+Kf)^0.5


,= 0.8

Carring Capacity [Q] ,= λ (2gH)^0.5 (CL 19.2.8 Page 76 IRC-SP-13-2004)


,= 2.35 cumec

Total Discharge Calculated By


1. Dicken's Method ,= 1.798 cumec
2. Rational Method ,= 1.422 cumec
3. Carrying Capacity ,= 2.352 cumec
4. Design Discharge ,= 1.798 cumec Safe
2.b
HYDRAULIC CALCULATION OF HUME PIPE CULVERT
DEVELOPMENT OF ROAD FROM AMAR FACTORY TO JAIL ROAD
AT CHAINAGE 0+555
1 Data
Structure Category ,= HPC
Catchment Area ,= 0.039 sq.km
,= 3.9 HEC
No. of Rows ,= 1 Nos.
Pipe Diameter ,= 1 m
Camber/Super Elevation ,= 2.50 %
Total Lenth Of Culvert ,= 12.5 m
Wearing Coat ,= 0.065 m
Provided FRL ,= 100.042 m

2 Discharge Based On Dicken's Method


Dicken's Discharge (Q) ,= C x M^(3/4) (Ref: Pg. 7-SP: 13-2004)
Normal Annual Rainfall ,= 112 Ref:- Flood Estimation Repor By CWC
Where C ,= 17
,= 1.492
Say ,= 1.492 m3/sec

3 Discharge Based On Rational Method


1. Catchment Area (A) ,= 0.039 sq.km
2. Length Of Longest Stream (L) ,= 0.5 Hec
3. Elevation Diffrence (H) ,= 1.4 m
4. Max. Rainfall Intensity (F) ,= 38.08 mm Ref:- Flood Estimation Repor By CWC
5. Duration Of Storm (T) ,= 24 hr

One Hour Rainfall Intensity I₀ ,= F x (T+1)/2T (Ref: Pg. 15-SP:13-2004)


,= 19.83333333 cm

Time Of Concentration Tc (Ref: Pg. 12-SP:13-2004)


Tc ,= (0.87 x L^3/H)^0.385
,= 0.556

Critical Intensity Of Rainfall in cm Per Hr Ic (Ref: Pg. 12-SP:13-2004)


Ic ,= I₀ x 2/(Tc+1)
,= 25.5 cm/hr

Chracterstics of the catchment area ,= 6 Loam , Lightly Cultivated or Covered


Coeficient Runoff (P) ,= 0.4 (Ref: Table 4.1-SP13-2004)
Fraction For C.A. in Hec 1.0 ,= 0.996 (Ref: Fig. 4.2-SP14-2004)
(Ref: Pg. 13-SP13-2004)
Discharge Q ,= 0.028 x P x f x A x Ic
Q ,= 1.11 Cumec

Pipe Configuration
No Of Rows ,= 1 Nos.
Pipe of Diameter ,= 1m

C/S Area of Pipe [A] ,= No of rows x [(Π/4) x D x D]


,= 0.785 Sqm
Perimeter of [P] ,= No of rows x [Π x D]
,= 3.142
Hydraulic Mean Radius [R] ,= [A] / [P]
0.250

Entry Loss Coeficient (Ke) ,= 1.107 x (R^0.5)


,= 0.554 (Table-19.1 Pg IRC-SP-13)

Friction Loss Coeficient [Kf] ,= 0.00394 x L / R^1.2


,= 0.260

Head [H] ,= 0.400

Coveyance factor [λ] ,= A/(1+Ke+Kf)^0.5


,= 0.6

Carring Capacity [Q] ,= λ (2gH)^0.5 (CL 19.2.8 Page 76 IRC-SP-13-2004)


,= 1.63 cumec

Total Discharge Calculated By


1. Dicken's Method ,= 1.492 cumec
2. Rational Method ,= 1.109 cumec
3. Carrying Capacity ,= 1.634 cumec
4. Design Discharge ,= 1.492 cumec Safe
2.b
HYDRAULIC CALCULATION OF HUME PIPE CULVERT
DEVELOPMENT OF ROAD FROM AMAR FACTORY TO JAIL ROAD
AT CHAINAGE 0+710
1 Data
Structure Category ,= HPC
Catchment Area ,= 0.1 sq.km
,= 10 HEC
No. of Rows ,= 2 Nos.
Pipe Diameter ,= 1.2 m
Camber/Super Elevation ,= 2.50 %
Total Lenth Of Culvert ,= 12.5 m
Wearing Coat ,= 0.065 m
Provided FRL ,= 100.042 m

2 Discharge Based On Dicken's Method


Dicken's Discharge (Q) ,= C x M^(3/4) (Ref: Pg. 7-SP: 13-2004)
Normal Annual Rainfall ,= 112 Ref:- Flood Estimation Repor By CWC
Where C ,= 17
,= 3.023
Say ,= 3.023 m3/sec

3 Discharge Based On Rational Method


1. Catchment Area (A) ,= 0.1 sq.km
2. Length Of Longest Stream (L) ,= 0.5 Hec
3. Elevation Diffrence (H) ,= 1.4 m
4. Max. Rainfall Intensity (F) ,= 38.08 mm Ref:- Flood Estimation Repor By CWC
5. Duration Of Storm (T) ,= 24 hr

One Hour Rainfall Intensity I₀ ,= F x (T+1)/2T (Ref: Pg. 15-SP:13-2004)


,= 19.83333333 cm

Time Of Concentration Tc (Ref: Pg. 12-SP:13-2004)


Tc ,= (0.87 x L^3/H)^0.385
,= 0.556

Critical Intensity Of Rainfall in cm Per Hr Ic (Ref: Pg. 12-SP:13-2004)


Ic ,= I₀ x 2/(Tc+1)
,= 25.5 cm/hr

Chracterstics of the catchment area ,= 6 Loam , Lightly Cultivated or Covered


Coeficient Runoff (P) ,= 0.4 (Ref: Table 4.1-SP13-2004)
Fraction For C.A. in Hec 1.0 ,= 0.996 (Ref: Fig. 4.2-SP14-2004)
(Ref: Pg. 13-SP13-2004)
Discharge Q ,= 0.028 x P x f x A x Ic
Q ,= 2.84 Cumec

Pipe Configuration
No Of Rows ,= 2 Nos.
Pipe of Diameter ,= 1.2 m

C/S Area of Pipe [A] ,= No of rows x [(Π/4) x D x D]


,= 2.262 Sqm
Perimeter of [P] ,= No of rows x [Π x D]
,= 7.540
Hydraulic Mean Radius [R] ,= [A] / [P]
0.300

Entry Loss Coeficient (Ke) ,= 1.107 x (R^0.5)


,= 0.606 (Table-19.1 Pg IRC-SP-13)

Friction Loss Coeficient [Kf] ,= 0.00394 x L / R^1.2


,= 0.209

Head [H] ,= 0.400

Coveyance factor [λ] ,= A/(1+Ke+Kf)^0.5


,= 1.7

Carring Capacity [Q] ,= λ (2gH)^0.5 (CL 19.2.8 Page 76 IRC-SP-13-2004)


,= 4.70 cumec

Total Discharge Calculated By


1. Dicken's Method ,= 3.023 cumec
2. Rational Method ,= 2.844 cumec
3. Carrying Capacity ,= 4.703 cumec
4. Design Discharge ,= 3.023 cumec Safe
2.b
HYDRAULIC CALCULATION OF HUME PIPE CULVERT
DEVELOPMENT OF ROAD FROM AMAR FACTORY TO JAIL ROAD
AT CHAINAGE 1+410
1 Data
Structure Category ,= HPC
Catchment Area ,= 0.029 sq.km
,= 2.9 HEC
No. of Rows ,= 1 Nos.
Pipe Diameter ,= 1 m
Camber/Super Elevation ,= 2.50 %
Total Lenth Of Culvert ,= 12.5 m
Wearing Coat ,= 0.065 m
Provided FRL ,= 100.042 m

2 Discharge Based On Dicken's Method


Dicken's Discharge (Q) ,= C x M^(3/4) (Ref: Pg. 7-SP: 13-2004)
Normal Annual Rainfall ,= 112 Ref:- Flood Estimation Repor By CWC
Where C ,= 17
,= 1.195
Say ,= 1.195 m3/sec

3 Discharge Based On Rational Method


1. Catchment Area (A) ,= 0.029 sq.km
2. Length Of Longest Stream (L) ,= 0.5 Hec
3. Elevation Diffrence (H) ,= 1.4 m
4. Max. Rainfall Intensity (F) ,= 38.08 mm Ref:- Flood Estimation Repor By CWC
5. Duration Of Storm (T) ,= 24 hr

One Hour Rainfall Intensity I₀ ,= F x (T+1)/2T (Ref: Pg. 15-SP:13-2004)


,= 19.83333333 cm

Time Of Concentration Tc (Ref: Pg. 12-SP:13-2004)


Tc ,= (0.87 x L^3/H)^0.385
,= 0.556

Critical Intensity Of Rainfall in cm Per Hr Ic (Ref: Pg. 12-SP:13-2004)


Ic ,= I₀ x 2/(Tc+1)
,= 25.5 cm/hr

Chracterstics of the catchment area ,= 6 Loam , Lightly Cultivated or Covered


Coeficient Runoff (P) ,= 0.4 (Ref: Table 4.1-SP13-2004)
Fraction For C.A. in Hec 1.0 ,= 0.996 (Ref: Fig. 4.2-SP14-2004)
(Ref: Pg. 13-SP13-2004)
Discharge Q ,= 0.028 x P x f x A x Ic
Q ,= 0.82 Cumec

Pipe Configuration
No Of Rows ,= 1 Nos.
Pipe of Diameter ,= 1m

C/S Area of Pipe [A] ,= No of rows x [(Π/4) x D x D]


,= 0.785 Sqm
Perimeter of [P] ,= No of rows x [Π x D]
,= 3.142
Hydraulic Mean Radius [R] ,= [A] / [P]
0.250

Entry Loss Coeficient (Ke) ,= 1.107 x (R^0.5)


,= 0.554 (Table-19.1 Pg IRC-SP-13)

Friction Loss Coeficient [Kf] ,= 0.00394 x L / R^1.2


,= 0.260

Head [H] ,= 0.400

Coveyance factor [λ] ,= A/(1+Ke+Kf)^0.5


,= 0.6

Carring Capacity [Q] ,= λ (2gH)^0.5 (CL 19.2.8 Page 76 IRC-SP-13-2004)


,= 1.63 cumec

Total Discharge Calculated By


1. Dicken's Method ,= 1.195 cumec
2. Rational Method ,= 0.825 cumec
3. Carrying Capacity ,= 1.634 cumec
4. Design Discharge ,= 1.195 cumec Safe