Darcy 1 Endurance Hydraulic Screen Technology
Darcy 1 Endurance Hydraulic Screen Technology
Screen
Positive Wellbore support preventing mobilisation of problematic sands, shales, coals etc.
Mechanical strength and collapse resistance for high geo-mechanical loads and extreme conditions
Conform to the borehole whilst maintaining base pipe geometry
Premium sand control combined with ICD capability and zonal isolation
Selective production, injection and shutoff with maximum ID Independent ISO Collapse Testing achieving 6,000psi and
Mechanical Crush Testing beyond API base pipe ratings
OPERATIONAL EFFICIENCY
Control,
Wellbore
Run in Activation Selectivity and
Support
Shut off
© Copyright Darcy 2015, CONFIDENTIAL 5
Endurance Hydraulic Screen® - Operational Efficiency (versus Gravel Pack)
MOBILISATION INSTALLATION & OPERATION
13 Gravel 1 x large work boat, Filter equipment, Chemicals, gels, Gravel pack Tote tanks
pack crew or elements gravel lab chemicals and
1.5 helicopter 1 x specialised Diatomaceous equipment fluids
trips vessel / spread with earth Completion brine
large deck space Laboratory Boat to back load
mud
Our environmentally neutral system lends itself to even the most remote or sensitive locations
HPHT
Horizontal & Multi-lateral wells
Stimulate the filter cake ahead of activation and
benefit from completion strength that is not subject Complete more complex wells with greater
to mechanical failure when the reservoir is depleted ease and less risk, when gravel packing isn’t an
over time. option.
Setting Tool
1 hr Rig Time 3. ACTIVATE HYDRAULIC SCREENS with surface applied pressure Reservoir
Isolation Shifting Tool
Valve
TIME & COST SAVINGS Approx. 30% reduction to overall completion timings on first 2 ‘Darcy’ wells
Bull Nose
“…The Darcy crew displayed above standard dedication to the performed operations, not only wrt. their own equipment but also providing advice,
support and QC-checks for other third party suppliers….”
“…Proactive and hands-on DARCY representatives onshore during whole detailed planning phase (from January to May), and also during
execution phase……Quick response on mail and actions from meetings…Cost estimate, risks and suggested improvements to DOP`s and
operation was provided according to deadline set...Very good work...”
Statoil D&W Engineers, May 2015
“…Overall Darcy have been available at all times and more than willingly to help, assist, explain and cooperate in the planning phase….Statoil is
very pleased with the work performed both on- and offshore, during planning, execution as post job analysis/AAR…”
Statoil D&W Engineer, Sept 2015
“…[Well] came in 7 days sharp, 3,2 days (or roughly 31%) below budget, with 7 ea. Darcy screens installed. This makes [Well] the 2nd fastest
completion in [license] history (after [well], the first Darcy well),and sets a new benchmark for what can be achieved…”
Statoil D&W Engineer, Sept 2015
Positive wellbore support in one simple step. Eliminate gravel packing without the need for additional downhole tools.
Systems selected on solid or pre-drilled base pipe platforms
Integral valve arrangement to deliver desired level of functionality
Under development
Endurance300® 5” Pre-drilled 6.625” 7.250” 8.000” Client Funded Development
Project
Note: additional size options are available for each Endurance Series
Darcy’s Facility Aberdeen, UK Library of Component Test Screen Prototypes Screen Manufacture
Samples
Burst and Collapse testing of the 6 5/8” Darcy screen system was conducted at Stress Engineering’s facility in Houston, as per ISO 17824.
Demonstrate the screen will conform to a well bore of variable diameter and eccentricity.
Two test scenarios are completed to determine tensile rating of shroud to base pipe
Testing conducted on the Clamp Body / Retainer Ring welds to establish the load capacity when welded as per
approved procedures
Weld Sheared
Weld Sheared
Welds to
test
Push Test Pull Test
The sample successfully tested, failure occurred at a load of The sample successfully tested, failure occurred at a load of
194,68lbs, almost double the required figure 166,812lbs, almost one and a half times the required figure