G-121-U Value Calculation-01

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES

1. THIS DRAWING IS THE COPYRIGHT OF ATI CONSULTANTS, ARCHITECTS AND ENGINEERS AND
MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE ABOVE CONSULTANT'S AUTHORITY.
2. DO NOT SCALE FROM THE DRAWINGS.
3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN METERS UNLESS NOTED OTHERWISE. ALL
DIMENSIONS TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.
4. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT ARCHITECTURAL,
STRUCTURAL, MECHANICAL, ELECTRICAL AND CIVIL DRAWINGS AND ALL RELEVANT SECTIONS
OF THE SPECIFICATIONS.
5. THE CONTRACTOR SHALL SUBMIT FULL SHOP / SETTING OUT DRAWING FOR APPROVAL (BASED
ON SITE DIMENSIONS) PRIOR TO COMMENCEMENT OF ANY SITE WORKS,PLACING OF ORDERS,
MANUFACTURE OF FITTINGS, FIXTURES AND COMPONENTS.

THERMO BLOCK WORK


INSIDE SURFACE FILM
RESISTANCE FOR WALL

PLASTER PAINT INSIDE SURFACE FILM


RESISTANCE FOR WALL
THERMO BLOCK WORK
PLASTER PAINT
THERMAL INSULATION
REINFORCED CONCRETE
PLASTER PAINT
THERMAL INSULATION
OUTSIDE SURFACE FILM PLASTER PAINT
RESISTANCE FOR WALL
OUTSIDE SURFACE FILM
RESISTANCE FOR WALL
INSIDE OUTSIDE
THERMO BLOCK WORK
INSIDE OUTSIDE

EXTERNAL WALL SEC. -01


(PLASTER PAINT FINISH)
EIFS APPROVED BY DM/DCD EXTERNAL DROP BEAM SEC. -01
(PLASTER PAINT FINISH)
EIFS APPROVED BY DM/DCD

INSIDE OUTSIDE
INSIDE SURFACE FILM
RESISTANCE FOR WALL
THERMO BLOCK WORK
PLASTER PAINT
THERMO BLOCK WORK

INSIDE SURFACE FILM


RESISTANCE FOR WALL
AIR SPACE
PLASTER PAINT
EXTERNAL CLADDING
SYSTEM (GRC) REINFORCED CONCRETE

OUTSIDE SURFACE FILM THERMAL INSULATION


RESISTANCE FOR WALL AIR SPACE
INSIDE OUTSIDE EXTERNAL CLADDING
SYSTEM (GRC)

OUTSIDE SURFACE FILM


RESISTANCE FOR WALL
EXTERNAL WALL SEC. -02
THERMO BLOCK WORK
(GRC CLADDING FINISH)
EXTERNAL DROP BEAM SEC. -02
(GRC CLADDING FINISH)

D 13/10/2023 IFC ATI


C 31/08/2023 DETAILED DESIGN ATI
B 23/06/2023 SCHEMATIC DESIGN ATI
A 19/05/2023 CONCEPT ATI
NO. DATE DESCRIPTION ISSUE BY

Lead Consultant
Arab & Turk International
Office 1001, 10th floor,
Westbury Office Tower,
Burj Khalifa Boulevard,
Downtown Dubai, U.A.E.
+971 (0)4 435 7490
www.ati-cae.com info@ati-cae.com
THERMO BLOCK WORK
Client
INSIDE SURFACE FILM
RESISTANCE FOR WALL
INSIDE SURFACE FILM INSIDE OUTSIDE
RESISTANCE FOR WALL
PLASTER PAINT

THERMO BLOCK WORK


AIR SPACE
THERMAL INSULATION
PLASTER PAINT Project
AMERICAN SCHOOL OF
REINFORCED CONCRETE
AIR SPACE
THERMAL INSULATION
CREATIVE SCIENCE
SPANDREL GLASS PANEL
AIR SPACE
PAHSE 01 - G+3+R,
AIR SPACE NAD AL SHEBA,DUBAI UAE
SPANDREL GLASS PANEL
VISION GLASS PANEL
AIR SPACE Discipline
OUTSIDE SURFACE FILM VISION GLASS PANEL
RESISTANCE FOR WALL
INSIDE OUTSIDE OUTSIDE SURFACE FILM
RESISTANCE FOR WALL
ARCHITECTURAL DRAWINGS
THERMO BLOCK WORK
Drawing Title
EXTERNAL WALL SEC. -03
(GLASS CURTAIN FINISH) EXTERNAL DROP BEAM SEC. -03
(GLASS CURTAIN FINISH)
U VALUE CALCULATION-01

Drawn Checked Approved


Author Checker Approver
Date Scale
13/10/2023 1 : 25 A1
Project No. Drawing No. Rev

D-241 G-121 D
This drawing, the designs and details shown are the copyright of Arab & Turk International
Consulting Architects and shall not be copied or reproduced in any form without their
written consent.

+971 (0)4 435 7492 Office 1001, 10th Floor, Westbury Office Tower, Burj Khalifa
www.ati-cae.com Boulevard, Downtown Dubai, United Arab Emirates

Plot Date: 13/10/2023 09:47:08