Unit Specification: ACW112D1312 Level Controller

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Unit Specification

ACW112D1312
Level Controller
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Fax: (763) 559-0108 ISSUE: 1 DATE: August 2004

GENERAL DESCRIPTION
The ACW112 Level Controller measures deviation from a gravity reference for mobile equipment such as hillside
combines and aerial lifts. Its sensing and switching components are contained within a single compact housing.
The Controller senses level through a suspended magnetic pendulum and Hall Effect sensors. Signals from the Hall
sensors provide ON-OFF electrical output to a three position, four way valve. The switching is instantaneous ON and
instantaneous OFF.

Dimensions of the ACW112D1312 in millimeters [inches].


95,2 [3.75]
47,6 [1.88] 68,3 [2.69]

Clearance holes
9,52 [0.38] for 1/4 inch bolts
(3)

138 [5.44]

Gauge points
119 [4.69] for leveling

4 leadwires
9,52 [0.38] 76,2 [3.0] 610 [24.0]
301A

CONNECTION DIAGRAM
ACW112
1 Rotation as viewed from cover side fo level controller
Black
ON Emergency
OFF shut off switch

Red Fuse

5A
Yellow Powered on CCW error

1 Jog switch

Orange Powered on CW error

1 Battery
284B

10102306 UNIT SPEC © Copyright 2004, Sauer-Danfoss.


1 OF 2 All rights reserved. Contents subject to change.
TECHNICAL DATA

Input voltage 12 V DC (11 to 15 V)


Voltage drop From input to output 2.5 V
Load current 4 A maximum
Supply current 100 mA plus required load current
Time delay 1/2 second
Damping fluid 5000 CS
Switch point ±1°
Differential Typically less than 1/2 degree turn-on to turn-off.
The difference between the nominal turn-on and turn-off is less than or equal to 1/2 degree.
See diagram Trip Point Variance From Zero Reference.

TRIP POINT VARIANCE FROM ZERO REFERENCE

ON
Output - voltage

Switch

OFF
-0.25 -0.20 -0.15 -0.10 -0.05 0.0 0.05 0.10 0.15 0.20 0.25
0 - Degree
1755

FAILURE MODES AND WARNINGS

Automatic controls are intended to move machine elements without operator input. This motion can be dangerous
to persons unfamiliar with the intended control action. Exercise care when operating the automatic control.

WWARNING
When the Level Controller is used as a switch to a tip alarm in rechargeable battery-operated electrical systems, the
warning device will not sound if the system voltage drops below the input voltage rating for the relay to the alarm.

WWARNING
This control uses a sensing signal which cannot be seen. This creates an extra danger of unforeseen stopping and
starting of machine components. Advise operators to turn the control OFF when people are near the sensor or the
controlled machine element.

10102306 UNIT SPEC