Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

ShockLog 248 Impact Recorder

• Alert recipients and operators to The ShockLog 248 is the entry model Features
inspect goods and equipment for in the ShockLog product line of impact
• Record max peak X, Y, and Z and
potential damage recorders, which includes the ShockLog
internal temperature
298 impact recorder. Available in 10G,
• Determine baseline damage
30G, and 100G impact scale ranges, • Record impact events (up to 15)
boundaries
the ShockLog 248 monitors impact and • Field-proven triaxial piezoelectric
• Detect mishandling during shipping, internal temperature, provides peak accelerometer technology
operation and storage,enabling you value (time slot) and summary period
to identify and assign accountability journey profile data. • Show direction of impact: X, Y, and Z
and take corrective action • User-definable alarm levels
ShockLog 248 delivers a visual alert that
• Make adjustments to product your product has encountered impact • Programmable wake-up levels for
packaging, loading process, events that might affect its performance maximising battery life
carriers, or mode of transport or safety, enabling immediate inspection
• LED lights for visual notification of
• Help identify opportunities and remediation at the time shipment
alarms and warnings
for improvement through is received or before installation in the
journey profiling field. The ShockLog 248 will record the • Self-contained unit design, free of
detailed impact curve for the first and cables and wires
14 most significant events. Up to 128 • iButton and USB data transfer options
event notifications are maintained in the
event summary log. • IP67-rated, RF-screened

• Temperature/humidity sensor built


into unit (optional)

solutions@shockwatch.com.au 1300 074 625 shockwatch.com.au Mar 2020


Applications Data Transfer Protect Your High Value Assets

The ShockLog 248 is designed for a The ShockLog has two options for data Customers use the ShockLog 248

variety of applications where a single transfer: USB or iButton interface. impact recorder to:

range/frequency filter is required. This Gain complete programming control • Alert recipients and operators to
versatile impact sensing solution also and full data access over the USB inspect goods and equipment for
offers optional environmental recording port. iButtons allow for easy control potential damage
capability, monitoring your products in for setup, download, and start and
• Detect mishandling during shipping,
transit, in use, and in storage. stop of the ShockLog. An overview
operation or storage, enabling you to
Below is a small sampling of can be downloaded using an iButton
identify and assign accountability and
applications in which the ShockLog 248 while keeping the unit secure and
take corrective action
has been used: tamperproof.
• Make adjustments to product
• A
 utomotive parts: Motors, pumps, packaging, loading process, carriers,
windshields, engines, transmissions ShockLog Software Allows For or mode of transport

• T
 ransportation: Rail cars, barges, Configuration, Data Extraction and
• Help identify opportunities for
cranes, and trucking fleets Analysis
improvement through journey

• E
 nergy: Oil and gas drilling tools, • S
 imple Windows-based software profiling

power transformers, nuclear materials, program


solar panels, and wind turbines • C
 lear instructions for quick
• D
 efense and aviation: Lasers, missiles, deployment and easy data analysis
munitions, gyroscopes, aircraft • O
 verview of the entire journey with
engines, rocket boosters, peak acceleration values for all three
and satellites axes reported on a time basis
• M
 edical and research: Lab • E
 xport data into programs such as
equipment, particle accelerator Excel for more detailed analysis
systems, MRI machines, dental chairs,
x-ray equipment

solutions@shockwatch.com.au 1300 074 625 shockwatch.com.au Mar 2020


Key Specifications
Temperature Range -40ºC to 85ºC / -22ºF to 185ºF

Dimensions 84mm x 84mm x 55mm

Weight 455g (without battery)

1 x 3.6V Lithium thionyl chloride*


Battery Type
1 x 1.5V AA alkaline*

Battery Life Up to 12 months (w/lithium battery)

Scale Range (factory set) 10G, 30G, 100G

Cut-off Frequency Options (factory set) 40Hz, 90Hz, 250Hz

Time Slots Up to 262,000

Time Slot Length 10sec to 1 hour

Humidity / Temperature Specifications

Temperature Range -40ºC to 85ºC / -22ºF to 185ºF

Humidity Measuring Range 0 - 100% RH

Dew Point Measuring Range -40ºC to 85ºC / -22ºF to 185ºF / 0 - 100% RH

*Always use lithium batteries for journeys where the temperature may be outside the -5°C to +50°C range. The capacity of alkaline batteries drops
dramatically when exposed to temperatures below 10°C. If using a lithium battery and the ShockLog will be traveling by air, make sure the battery
is aproved for air cargo. If the batteries are accidentally installed with the wrong polarity, the ShockLog will not be damaged; however, the life of
the battery may be severely affected.

solutions@shockwatch.com.au 1300 074 625 shockwatch.com.au Mar 2020

You might also like