ATEX RESPONSIBILITY
ATEX IECEx RESPONSIBILITY
NB – Notified Body HAZARDOUS AREA ZONE EQUIPMENT PROTECTION LEVEL (EPL)
EQUIPMENT CB – Certification Body
M – Manufacturer
CATEGORY
TYPE EXAMINATION PRODUCTION GAS DUST GAS DUST TYPE EXAMINATION PRODUCTION
NB NB 1 0 20 Ga Da CB CB
M M 2 1 21 Gb Db CB CB
Technical File stored with NB
M M 3 2 22 Gc Dc CB CB
13463-5 c c
1 21
Constructional safety 80079-37 Ex h Ex h
1 21 Ga/Da ** ** *
2 22 2 22
Gb/Db * * N/A
1 21 Control of ignition 1 21
13463-6 b b
2 22 sources
80079-37 Ex h Ex h
2 22
Gc/Dc * N/A N/A
1 21 1 21
13463-8 k k Liquid immersion 80079-37 Ex h Ex h * Describe the single measure applied to prevent the ignition
2 22 2 22
source from becoming effective. Where appropriate refer to
© SGS United Kingdom Ltd – 2020 – All rights reserved - SGS is a registered trademark of SGS Group Management SA 5608/0320 - BAS-WC-002 - Issue 3 - February 2020
SGS BASEEFA SERVICES • IEC 61508 certification SGS BASEEFA LIMITED tel. +44 (0)1298 766600
• Training and technical advice fax. +44 (0)1298 766601
• ATEX and IECEx equipment/component • Quality system approval • IECEx service facility certification Rockhead Business Park,
certification e-mail: baseefa@sgs.com
• Assistance with DSEAR • Technical file storage Staden Lane, Buxton, SK17 9RZ www.sgs.co.uk/sgsbaseefa
• IECEx certificate of personnel competence (ATEX user directive) implementation • Testing