CMP IECEx ATEX 01 Compressed

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

www.cmp-products.

com
IECEx &
NEWCASTLE (Headquarters)
CMP Products
36, Nelson Way, Nelson Park East,
DUBAI
CMP Products Middle East Office
P.O. Box 61363,
ATEX 95
Cramlington, Northumberland, Jebel Ali Free Zone, Jebel Ali,
NE23 1WH, England Dubai,
Tel: +44 191 265 7411 United Arab Emirates
Fax: +44 01670 715646 Tel: +971 4 887 1012
E-Mail: cmp@cmp-products.com Fax: +971 4 887 1015
E-Mail: meoffice@cmp-products.com

HOUSTON PUSAN
CMP Products Texas Inc CMP Products (Korea) Ltd
5222 N Sam Houston Parkway E. 19F Rm1915 Centum IS Tower, #1209,
Houston, Texas 77032, USA Jaesong1-dong, Haeundae-gu, Busan,
Tel: +281 776 5201 South Korea, 612051
Fax: +281 776 5223 Tel: +82 51 780 5300
E-Mail: houstonoffice@cmp-products.com Fax: +82 51 780 8348
E-Mail: pusanoffice@cmp-products.com

SINGAPORE SHANGHAI
CMP Products (S.E.A) Pte Ltd. CMP Products Division
21 Toh Guan Road East, #09-03, Room 304, Building 7,
Toh Guan Centre No.1888 Xinjinqiao Road,
Singapore 608609 Pudong, Shanghai 201206,
Tel: +65 6466 6180 P.R. China
Fax: +65 6466 9891 Tel: +86 21 6093 2633
E-Mail: seaoffice@cmp-products.com Fax: +86 21 6093 2630
E-Mail: shanghaioffice@cmp-products.com
CMP PRODUCTS
PERTH, WA
Street Address :
CMP Products Pty Ltd
Unit 2-3/22 Harlond Avenue, Malaga, WA 6090
Postal Address :
CMP Products Pty Ltd
PO Box 1994, Malaga, WA 6944
Tel: +61 8 9249 4508
Fax: +61 8 9249 4608
E-Mail: perthoffice@cmp-products.com
CMP PRODUCTS

Cable Glands approved for Group I mining applications are also available from CMP Products
for a wide variety of cable types.

CABLE GLANDS AND CONNECTORS


Distributor :
FOR THE IEC & NEC WORLD • ATEX 95 & BEYOND

Single Solution • Three Forms of Protection


Ex d / Ex e / Ex nR
Document Reference : TPC168 – ISSUE 3 – 04/12
N O O T H E R M A N U F A C T U R E R G I V E S Y O U M O R E

CONTENTS TRITON CDS - T3CDS


Flameproof Ex d, Increased Safety Ex e and
Restricted Breathing Ex nR Cable Gland
CABLE GLANDS FOR HAZARDOUS AREAS
CMP Triton CDS Type T3CDS Triple Certified Flameproof
T3CDS & T3CDS/PB 1 (Type 'd'), Increased Safety (Type 'e') and Restricted Breathing
(Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone
E1FW & E2FW 2 2, Zone 21 and Zone 22 Hazardous Areas with all types of armoured
cable providing a flameproof seal on the cable inner bedding and an
E1FX & E2FX 3 environmental seal on the cable outer sheath.This product utilises a
unique Compensating Displacement Seal (CDS) system which
E1FU & E2FU 4 provides full compatibility with Restricted Breathing equipment that
Leading the Way in Hazardous Areas rely upon flammable gases being excluded from the main enclosure.
PX2K & PXSS2K 5 The cable gland provides mechanical cable retention and electrical
continuity via armour wire termination. A reversible armour cone and
CMP Products has an international reputation for Quality and Reliability in
RAPID Ex 6 AnyWay universal clamping ring arrangement allows the cable to be easily disconnected from the equipment, for
various sectors of Industry and is highly regarded as the Specialist in the field maintenance and change out etc., and re-connected with the same consummate ease. This feature also facilitates
of Industrial and Hazardous Area Cable Gland and Cable Connector design PX2K-REX & PXSS2K-REX remote make off procedures when the termination is to be conducted in confined spaces or in areas of restricted
7
and manufacture. access. Separate tightening actions for the inner compensating displacement seal (CDS) system and the armour
A2F, A2FRC, A2F-FC 8 termination affords maximum control over the pressure applied to the cable inner bedding.
CMP Products maintains its position as a leader in the business of All CMP Cable Glands are EMC tested.
terminating cables through its commitment to meeting customer needs, A2PE, SS2K, C2K 9
The CMP Triton CDS Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1,
providing solutions, whether standard or special, that pay close attention to CWE, CXE, C2KX Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, installation and
10
the heart of application and installer requirements, and in addition by maintenance is observed, e.g. IEC 60079-14.
responding to ongoing changes in standards & specification. PX2K-REX, TMC2, TMC2X 11
APPROVAL DETAIL TECHNICAL DATA
CMP Products remains in constant touch with the changes in development ATEX : SIRA06ATEX1283X, SIRA07ATEX4328X TEMPERATURE RATING : -60°C TO +130°C
of national and international standards, which products and equipment CABLE GLANDS FOR INDUSTRIAL AREAS ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, DELUGE PROTECTION : TO DTS 01:91
intended for use in flammable atmospheres must meet. Ex nR II, Ex tD A21 IP66: IM2 Exd I / Exe I CABLE TYPE : Aluminium Strip Armour (ASA), Screened Flexible Wire Braid
IECEx : IECEx SIR 07.0005X (e.g. CY / SY), Single Wire Armour (SWA), Aluminium Wire Armour (AWA),
BW, CX, CW, A2, SS2KGP, 12 Ingress Protection : IP66, IP67, IP68 Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour
Many cable gland products for use in Zones 1, 2, 21 & 22 Hazardous Areas SS2KGP/PB, E1U (e.g. SWB), Armored & Jacketed
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
have been available for several years with Dual Certification, referring to both GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS SEALING AREA(S) : Cable Inner Bedding & Outer Cable Sheath
Flameproof Type ‘d’ (Ex d) and Increased safety Type ‘e’ (Ex e) forms of E2U, E1W, E2W, E1X, E2X, 13
protection, according to IEC 60079, parts 1 and 7. Whilst this has suited the A2DG, A2 200
requirements for the majority of equipment types installed in hazardous
areas, there are other forms of protection, including Zone 2 Ex n apparatus,
where Ex d and Ex e cable glands may not be adequate. With special regard Flameproof Ex d, Increased Safety Ex e and
to Category II 3 GD Restricted Breathing Type Ex nR equipment, it is CONVERSION, ADAPTORS, REDUCERS TRITON CDS - T3CDS/PB Restricted Breathing Ex nR Cable Gland
particular important to consider the suitability of the cable glands to maintain & ACCESSORIES
the integrity of the installation, as some Ex d cable glands do not meet the
CMP Triton CDS Type T3CDS/PB Triple Certified Flameproof (Type 'd'),
test requirements of IEC 60079-15 for Ex nR equipment. TYPE 737 - ADAPTOR/REDUCER Increased Safety (Type 'e') and Restricted Breathing (Type ‘nR’) indoor
14 and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone
CMP Products has therefore taken the principle of dual certification one step
TYPES 747, 757, 767 - STOPPER PLUGS 22 Hazardous Areas with all types of lead sheathed / lead covered
further and for the first time introduces Triple Certified Ex d, Ex e, & Ex nR and armoured cable providing a flameproof seal on the cable inner
TYPE 781 - BREATHER/DRAIN PLUG lead covering and an environmental seal on the cable outer sheath.
approved cable glands that are indeed compatible with more types of
This product utilises a unique Compensating Displacement Seal (CDS)
equipment than ever before and brings to the market truly universal solutions. TYPE 777 - INSULATED ADAPTOR system which provides full compatibility with restricted breathing
No doubt that after careful review this makes the possibility of standardisation equipment that rely upon flammable gases being excluded from the
on single cable gland solutions for the majority of the Zone 1 & Zone 2, or main enclosure. The cable gland being suitable for use with armoured
Zone 21 & Zone 22, hazardous area equipment, worthy of serious cables, provides mechanical cable retention and electrical continuity
TYPE 780 - UNIONS via armour wire termination and earth bonding of the lead sheath. A reversible armour cone and AnyWay universal
consideration.
clamping ring arrangement allows the cable to be easily disconnected from the equipment, for maintenance and
TYPE 797 - ADAPTORS change out etc, and re-connected with the same consummate ease. This feature also facilitates remote make off
The adoption and integration of IEC standards into a selection of various procedures when the termination is to be conducted in confined spaces or in areas of restricted access. Separate
national standards around the world, including the European Normatives,
LOCKNUTS, SERRATED WASHERS, 15 tightening actions for the inner compensating displacement seal (CDS) system and the armour termination affords
together with the introduction, and wide spread acceptance, of the IECEx maximum control over the pressure applied to the cable inner lead covering.
EARTH TAGS, SHROUDS & ENTRY
approval scheme (IECEx 02) gives a new impetus to progressive All CMP Cable Glands are EMC tested.
manufacturers like CMP Products. It is now possible to supply cable THREAD SEALS
The CMP Triton CDS Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1,
connecting solutions that are certified under both the CENELEC / ATEX and Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, installation and
IECEx approval systems thereby providing the opportunity for dual marking of maintenance is observed, e.g. IEC 60079-14.
products that can be installed in global situations. SELECTION INFORMATION
CABLE GLAND SELECTION GUIDELINES 16 APPROVAL DETAIL TECHNICAL DATA
ATEX : SIRA06ATEX1283X, SIRA07ATEX4328X TEMPERATURE RATING : -60°C TO +130°C
CMP Products - a Global Solutions Provider of Cable Glands, ORDERING INFORMATION ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, DELUGE PROTECTION : TO DTS 01:91
Ex nR II, Ex tD A21 IP66 CABLE TYPE : Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed
Cable Connectors, and Complementary Cable Related Products CABLE GLAND SELECTION CHARTS 17 & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour
IECEx : IECEx SIR 07.0005X
& Accessories Ingress Protection : IP66, IP67, IP68 (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed &
Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS, SEALING AREA(S) : Cable Inner Lead Covering & Cable Outer Sheath
Cable Glands and Cable Connectors are available in a variety of materials
including Brass, Nickel, Plated Brass, Aluminium, & Stainless Steel, and
www.cmp-products.com with a wide variety of thread forms. A full range of installation accessories
is also available on request. 1
1
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

Flameproof Ex d, Increased Safety Ex e and Flameproof Ex d, Increased Safety Ex e and


E1FW TRI-STAR Restricted Breathing Ex nR Cable Gland E1FX TRI-STAR Restricted Breathing Ex nR Cable Gland

CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased CMP Type E1FX Tri-Star Triple Certified Flameproof (Type ‘d’),
Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’)
in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone
Wire Armour (SWA) cable. 21 and Zone 22 Hazardous Areas with Braided, Pliable Wire
Armour (PWA), Strip Armour and Steel Tape Armour (STA)
This cable gland provides a flameproof seal on the cable inner bedding cable. This cable gland provides a flameproof seal on the cable
and in addition the gas tight seal has been tested to prove compatibility inner bedding and in addition the gas tight seal has been tested
with Restricted Breathing equipment. to prove compatibility with Restricted Breathing equipment. The
cable gland allows mechanical cable retention and earth
The cable gland allows mechanical cable retention and earth continuity via
continuity via the cable armour termination.
the cable armour termination. Separate tightening actions for the inner
displacement seal and the armour termination afford maximum control over the pressure applied to the cable bedding, and Separate tightening actions for the inner displacement seal and the armour termination afford maximum
also allows the effectiveness of the gas tight seal to be tested. control over the pressure applied to cable bedding, and also allows the effectiveness of the gas tight seal to
be tested. A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off
A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be and enables the cable to be disconnected from the equipment. An environmental / load retention seal is
disconnected from the equipment.An environmental / load retention seal is provided on the cable outer sheath. provided on the cable outer sheath.
All CMP Cable Glands are EMC tested. All CMP Cable Glands are EMC tested.

The CMP E1FW Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, The CMP E1FX Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and
IEC 60079-14 installation is observed, e.g. IEC 60079-14.

APPROVAL DETAIL TECHNICAL DATA APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, Ex CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour (AWA) ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, CABLE TYPE : Screened Flexible Wire Braid (e.g. CY / SY), Pliable Wire Armour
nR II, Ex tD A21 IP66: I M2 Ex dI, Ex e I Ex nR II, Ex tD A21 IP66: I M2 Ex dI, Ex e I (PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip
SEALING AREA(S) : Cable Inner Bedding & Outer Cable Sheath
IECEx : IECEx SIR 06.0043X IECEx : IECEx SIR 06.0043X Armour (ASA), Armored & Jacketed
Ingress Protection : IP66, IP67, IP68 Ingress Protection : IP66, IP67, IP68 SEALING AREA(S) : Cable Inner Bedding & Outer Cable Sheath
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS

Flameproof Ex d, Increased Safety Ex e and Flameproof Ex d, Increased Safety Ex e and


E2FW TRI-STAR Restricted Breathing Ex nR Cable Gland E2FX TRI-STAR Restricted Breathing Ex nR Cable Gland

CMP Type E2FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased CMP Type E2FX Tri-Star Triple Certified Flameproof (Type ‘d’),
Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’)
in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with lead cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22
covered or lead sheathed and single wire armour (SWA) cable. Hazardous Areas with Lead Covered or Lead Sheathed and
Braided, Pliable Wire Armour (PWA), Strip Armour, or Steel
This cable gland provides a flameproof seal on the cable inner lead Tape Armour (STA) cable.
covering and in addition the gas tight seal has been tested to prove
compatibility with Restricted Breathing equipment that relies upon This cable gland provides a flameproof seal on the cable inner
flammable gases being excluded from the main enclosure. The cable gland lead covering and in addition the gas tight seal has been tested
allows mechanical cable retention and earth continuity via the cable to prove compatibility with restricted breathing equipment. The
armour termination, and also earth bonding of the inner lead covering or cable gland allows mechanical cable retention and earth
lead sheath. Separate tightening actions for the inner displacement seal and the armour termination afford maximum control continuity via the cable armour termination, and also earth bonding of the inner lead covering or lead sheath.
over the pressure applied to the cable inner lead covering, and also allows the effectiveness of the gas tight seal to be tested. Separate tightening actions for the inner displacement seal and the armour termination afford maximum
A detachable armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be control over the pressure applied to cable inner lead covering, and also allows the effectiveness of the gas
disconnected from the equipment. An environmental / load retention seal is provided on the cable outer sheath. tight seal to be tested. A detachable armour cone and AnyWay clamping ring arrangement facilitates remote
make off and enables the cable to be disconnected from the equipment. An environmental / load retention
All CMP Cable Glands are EMC tested. seal is provided on the cable outer sheath.
All CMP Cable Glands are EMC tested.
The CMP E2FW Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2,
Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, The CMP E2FX Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
e.g. IEC 60079-14. Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and
installation is observed, e.g. IEC 60079-14.

APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
APPROVAL DETAIL TECHNICAL DATA
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II,
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
CABLE TYPE : Lead Sheathed & Single Wire Armour (SWA)
Ex nR II, Ex tD A21 IP66: I M2 Ex dI, Ex e I ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, CABLE TYPE : Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed
SEALING AREA(S) : Cable Inner Bedding & Outer Cable Sheath Ex nR II, Ex tD A21 IP66 I M2 Ex dI, Ex e I & Pliable Wire Armour (LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA),
IECEx : IECEx SIR 06.0043X
Ingress Protection : IP66, IP67, IP68 IECEx : IECEx SIR 06.0043X Lead Sheathed & Strip Armour (LC/ASA)
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), Ingress Protection : IP66, IP67, IP68 SEALING AREA(S) : Cable Inner Lead Sheath & Outer Sheath
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS

2 3

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

Flameproof Ex d, Increased Safety Ex e and Flameproof Ex d, Increased Safety Ex e, Restricted


E1FU TRI-STAR Restricted Breathing Ex nR Cable Gland PX2K Breathing Ex nR Compound Barrier Cable Gland

CMP Type E1FU Tri-Star Triple Certified Flameproof (Type ‘d’), CMP Type PX2K Triple Certified Flameproof (Type ‘d’), Increased Safety
Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone
indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of
21 and Zone 22 Hazardous Areas with all types of armoured armoured cable providing a compound barrier seal around the cable
cable. conductors and an environmental seal on the cable outer sheath. The
cable gland provides mechanical cable retention and electrical continuity
This cable gland provides a flameproof seal on the cable inner via armour termination.
bedding and in addition the gas tight seal has been tested to
prove compatibility with Restricted Breathing equipment. A combined detachable armour cone and compound tube, together with
The cable gland allows mechanical cable retention and earth AnyWay universal clamping ring arrangement allows the cable to be
continuity via the cable armour termination. Separate tightening easily disconnected from the equipment, for maintenance and change out
actions for the inner Displacement Seal and the Armour Termination afford maximum control over the pressure etc, and re connected with the same consummate ease. This feature also facilitates remote make off procedures when the
applied to the cable bedding, and also allows the effectiveness of the gas tight seal to be tested. termination is to be conducted in confined spaces or in areas of restricted access.

A reversible armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables All CMP Cable Glands are EMC Tested.
the cable to be disconnected from the equipment. An environmental / load retention seal is provided on the
cable outer sheath. The CMP PX2K cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 &
Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
The CMP E1FU Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in The PX2K is supplied in kit form inclusive of two detachable armour cones. Stepped Cone is suitable for SWA cables,
Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and Grooved Cone is suitable for all other approved armoured cables. PX2K/PB for use with lead sheathed/lead covered cables.
installation is observed, e.g. IEC 60079-14.

APPROVAL DETAIL TECHNICAL DATA APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +100°C
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour (AWA), ATEX Code of Protection Category : Ex II 2/3 GD, Ex d IIC, DELUGE PROTECTION : DTS01:91
Ex nR II, Ex tD A21 IP66: I M2 Ex dI, Ex e I Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour Ex e II, Ex nR II, Ex tD A21 IP66; IM2 Ex d, Exe I CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour (AWA),
IECEx : IECEx SIR 06.0043X (ASA), Pliable Wire Armour (PWA), Screened Flexible Wire Braid (e.g. CY / SY), IECEx : IECEx SIR 06.0044X Wire Braid Armour (e.g. SWB), Screened Flexible Wire Braid (e.g. CY / SY),
Ingress Protection : IP66, IP67, IP68 Armored & Jacketed Ingress Protection : IP66, IP67, IP68 Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), SEALING AREA(S): Cable Inner Bedding & Outer Cable Sheath Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), SEALING AREAS : Inner Compound Barrier & Outer Sheath
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS, INMETRO GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS, INMETRO

Flameproof Ex d, Increased Safety Ex e and Flameproof Ex d, Increased Safety Ex e and


E2FU TRI-STAR Restricted Breathing Ex nR Cable Gland PXSS2K Restricted Breathing Ex nR Cable Gland

CMP Type E2FU Tri-Star Triple Certified Flameproof (Type ‘d’), CMP Type PXSS2K Triple Certified Flameproof (Type ‘d’),
Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’)
indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22
21 and Zone 22 Hazardous Areas with all types of Lead Covered Hazardous Areas with all types of unarmoured cable providing a
or Lead Sheathed and armoured cable. This cable gland compound barrier seal around the cable conductors and an
provides a flameproof seal on the cable inner lead covering and environmental seal on the cable outer sheath.
in addition the gas tight seal has been tested to prove
compatibility with Restricted Breathing equipment. The cable The cable gland provides mechanical cable retention.
gland allows mechanical cable retention and earth continuity via
the cable armour termination, and also earth bonding of the A combined washer and compound tube allows the cable to be
inner lead Covering or lead sheath. easily disconnected from the equipment, for maintenance and
change out etc, and re-connected with the same consummate ease. This feature also facilitates remote make
Separate tightening actions for the inner Displacement Seal and the Armour Termination afford maximum off procedures when the termination is to be conducted in confined spaces or in
control over the pressure applied to the cable inner lead covering, and also allows the effectiveness of the gas areas of restricted access.
tight seal to be tested. A detachable universal armour cone and AnyWay clamping ring arrangement
facilitates remote make off and enables the cable to be disconnected from the equipment. An environmental / All CMP Cable Glands are EMC Tested.
load retention seal is provided on the cable outer sheath.
The CMP PXSS2K cable gland is suitable for use with all forms of equipment protection permitted in Zone 1,
The CMP E2FU Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation
Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and is observed, e.g. IEC 60079-14.
installation is observed, e.g. IEC 60079-14.

APPROVAL DETAIL TECHNICAL DATA APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +100°C
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, Ex CABLE TYPE : Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, Ex nR DELUGE PROTECTION : DTS01:91
nR II, Ex tD A21 IP66: I M2 Ex dI, Ex e I & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour II, Ex tD A21 IP66; IM2 Ex d, Exe I CABLE TYPE : Unarmoured
IECEx : IECEx SIR 06.0043X (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed & IECEx : IECEx SIR 06.0044X SEALING AREAS : Inner Compound Barrier & Outer Sheath
Ingress Protection : IP66, IP67, IP68 Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA) Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), SEALING AREA(S): Cable Inner Lead Covering & Cable Outer Sheath Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS, INMETRO

4 5

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

PX2K-REX Flameproof Ex d, Increased Safety Ex e,


PX2K-REX Restricted Breathing Ex nR Resin Barrier Cable Gland

RapidEx is the revolutionary method for installing barrier glands. The gland
utilises a liquid pour resin seal, that vastly reduces installation time and
associated costs. This solution is particularly effective on multicore cables
where traditional compound is difficult and time consuming to apply.
A revolutionary sealing solution for CMP Type PX2K-REX Triple Certified Flameproof (Type ‘d’), Increased

barrier glands that also delivers Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in
Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of

increased reliability armoured cable providing a RapidEx barrier seal around the cable
conductors and an environmental seal on the cable outer sheath.

All CMP Cable Glands are EMC Tested.


is a Liquid Pour, Fast Curing, Liquid Resin Seal that
The cable gland provides mechanical cable retention and electrical continuity via armour termination. A combined detachable
installs in seconds and cures in minutes. Its unique armour cone and resin tube, together with AnyWay universal clamping ring arrangement allows the cable to be easily
formula begins with a low viscosity liquid that flows disconnected from the equipment, for maintenance and change out etc., and re connected with the same consummate ease.
into the cable interstices completely surrounding This feature also facilitates remote make off procedures when the termination is to be conducted in confined spaces or in areas
of restricted access. The CMP PX2K-REX cable gland is suitable for use with all forms of equipment protection permitted in Zone
the cable conductors, driving out the air in the process. The viscosity then
1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed,
increases and completely cures in minutes, dependant on ambient e.g. IEC 60079-14. The PX2K-REX is supplied in kit form inclusive of two detachable armour cones. Stepped Cone is suitable
temperature. for SWA cables, Grooved Cone is suitable for all other approved armoured cables. PX2K-REX/PB for use with lead
sheathed/lead covered cables.
RapidEx benefits
APPROVAL DETAIL TECHNICAL DATA
is a revolutionary sealing system that gets ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +85°C
right to the heart of the cable interstices and ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour (AWA),
Ex nR II, Ex tD A21 IP66, IM2 Ex d I, Ex e I Wire Braid Armour (e.g. SWB), Screened Flexible Wire Braid (e.g. CY / SY),
can be reliably installed in no time at all.
IECEx : IECEx SIR 06.0044X Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)
SEALING AREA(S) : Inner RapidEx Resin Barrier & Outer Sheath
• Simple cable preparation, Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : GOST R (POCC GB.HO06.B00207),
• Easy liquid pour RapidEx resin application, INMETRO, ABS, DNV, LLOYDS, NEPSI, cCSAus

• Cleaner, faster mixing process,


• High consistency of liquid pour fill,
• Fully compatible with IEC & CEC / NEC wiring code rules,
• Thermal endurance / age tested to IEC 60079-0:2007, PXSS2K-REX Flameproof Ex d, Increased Safety Ex e,
• Explosion pressure tested to IEC 60079-1:2007, CSA-C 22.2 and PXSS2K-REX Restricted Breathing Ex nR Compound Barrier Cable Gland
UL 2225,
• No need for repeated cable gland disassembly before connection RapidEx is the revolutionary method for installing barrier glands. The gland
to equipment, utilises a liquid pour resin seal, that vastly reduces installation time and
• Faster RapidEx curing time, allowing earlier energizing of associated costs. This solution is particularly effective on multicore cables
where traditional compound is difficult and time consuming to apply.
equipment,
• Enhanced accuracy, improved reliability. CMP Type PXSS2K-REX Triple Certified Flameproof (Type ‘d’), Increased
Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in
Ease of application Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of
unarmoured cable providing a barrier seal around the cable conductors and
an environmental seal on the cable outer sheath.
During application the liquid resin flows between and around the cable
conductors ensuring a complete and total seal with zero gaps. All CMP Cable Glands are EMC Tested.

In the process of curing the RapidEx resin adheres to both the cable The cable gland provides mechanical cable retention. A combined detachable spacer and resin tube allows the cable to be
conductors and the inside of the barrier tube creating a bond that is set for easily disconnected from the equipment, for maintenance and change out etc., and re-connected with the same consummate
the life of the cable gland product. The RapidEx seal will never crack or ease. This feature also facilitates remote make off procedures when the termination is to be conducted in confined spaces or in
areas of restricted access.
shrink with changes in temperature.
The CMP PXSS2K-REX cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone
Faster curing 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.

RapidEx liquid pour resin cures approximately 15 times faster than


traditional clay based compound. RapidEX cures in 15 minutes at 40ºC,
APPROVAL DETAIL TECHNICAL DATA
and 30 minutes at 20ºC. ATEX : SIRA 06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +85°C
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, CABLE TYPE : Unarmoured
Enhanced reliability Ex nR II, Ex tD A21 IP66,
IECEx : IECEx SIR 06.0044X
IM2 Ex d I, Ex e I
SEALING AREA(S) : Inner RapidEx Resin Barrier & Outer Sheath

Ingress Protection : IP66, IP67, IP68


RapidEx offers users a combination of advantages not least of which is the
Additional Approvals Held : GOST R (POCC GB.HO06.B00207),
enhanced reliability that the product delivers in ensuring that the form of INMETRO, ABS, DNV, LLOYDS, NEPSI, cCSAus
equipment protection is not compromised in anyway.
6 7

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

Flameproof Ex d, Increased Safety Ex e EX L & EX M Cable Gland (A2Pe) Code of


A2F and Restricted Breathing Ex nR Cable Gland V-TEC EX Protection EEx e II
CMP Type A2F Triple Certified Flameproof (Type 'd'), Increased Safety (Type 'e') The CMP V-TEC Type EX, EX L & M Range (A2Pe) of Increased Safety
and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in (Type ‘e’) Non-Metallic Cable Glands for Unarmoured and Screened Flexible
Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured and Cables, is endorsed by an EC design type approval certificate in accordance with
braided cable providing a combined flameproof seal and environmental seal on the requirements of EN50014 : 1997 & EN50019 : 1994 and the ATEX Directive
the cable outer sheath. This product provides full compatibility with restricted 94/9/EC, concerning safety of Electrical Equipment, Products and Protection
breathing equipment that rely upon flammable gases being excluded from the Systems for use in potentially explosive atmospheres (Hazardous Areas).
main enclosure.
These Cable Gland products provide an environmental seal on the cable outer
The CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment sheath and have been introduced as a cost effective solution for all indoor and
protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, outdoor cable installations in Zone 1 and Zone 2 Hazardous Areas, where Ex e or EEx e Code of Protection has been
installation and maintenance is observed, e.g. IEC 60079-14. permitted. This cable gland is also suitable for use in conjunction with Ex de or EEx de equipment and apparatus which has an
increased safety terminal chamber.EC design type approval certificate number : PTB 99 ATEX 3112X and 3113X.

APPROVAL DETAIL TECHNICAL DATA


EC design type approval certificate number : V
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C D
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, DELUGE PROTECTION : DTS01:91
PTB 99 ATEX 3112X and 3113X.
Ex e II, Ex nR II, Ex tD A21 IP66; IM2 Exd I, Exe I CABLE TYPE : Unarmored & Braided
IECEx : IECEx SIR 06.0044X SEALING AREA (S) : Inner Compound Barrier & Outer Sheath Flameproof Ex d, Increased Safety Ex e &
Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : CSA, GOST R (POCC GB.ГБ05.06.B00207),
SS2K Restricted Breathing Ex nR Cable Gland
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS, INMETRO

CMP Type SS2K Tri-Star Triple Certified Flameproof (Type 'd'), Increased Safety
(Type 'e') and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for
Flameproof Ex d, Increased Safety Ex e and Restricted use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured
A2FRC Tri star Breathing Ex nR Cable Gland for Conduit Connection
cables. This cable gland provides a flameproof seal on the cable inner sheath (or
outer sheath of single sheathed cable) and a secondary environmental seal
on the cable outer sheath. This cable gland can also be used with braided cables
CMP Type A2FRC Tri-Star Triple Certified Flameproof (Type 'd'), Increased Safety where the sealing is made on the cable overall diameter, when this arrangement is
(Type 'e') and Restricted Breathing (Type ‘nR’) indoor and outdoor conduit permitted by the prevailing installation code of practice, and the metallic braid is
connection cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 earthed inside the equipment.
hazardous areas with un-armoured cable housed in rigid or flexible conduit
systems. The cable gland provides a combined flameproof seal and environmental This product provides full compatibility with Restricted Breathing equipment and affords extra stability and superior resistance
seal on the cable outer sheath. This product provides full compatibility with to cable pull out. The CMP SS2K Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in
restricted breathing equipment. Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is
observed, e.g. IEC 60079-14. SS2k/PB for use with lead sheathed/lead covered cables & SS2K/TA for use with steel tape
The CMP A2FRC Tri-Star Cable Gland is suitable for use with all forms of armour also available.
equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice
for selection and installation is observed, e.g. IEC 60079-14. APPROVAL DETAIL TECHNICAL DATA
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, DELUGE PROTECTION : DTS01:91
APPROVAL DETAIL TECHNICAL DATA Ex nR II, Ex tD A21 IP66 CABLE TYPE : Unarmored & Braided
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C IECEx : IECEx SIR 06.0041X SEALING AREA (S) : Cable Inner Bedding & Outer Cable
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, CABLE TYPE : Unarmored & Braided Ingress Protection : IP66, IP67, IP68 Sheath, Double Seal on Cable Outer Sheath
Ex e II, Ex nR II, Ex tD A21 IP66 SEALING AREA (S) : Cable Outer Sheath Additional Approvals Held : GOST R (POCC GB. ГБ06.B00207),
IECEx : IECEx SIR 06.0040X GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS, CSA
Ingress Protection : IP66
Additional Approvals Held : GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), CSA, INMETRO, ABS, DNV, LLOYDS

C2K Increased Safety Ex e Cable Gland


C2K
Flameproof Exd, Increased Safety Ex e and Restricted Breathing
A2F-FC Tri Star Ex nR Cable Gland For Flexible Metallic Conduit Connection CMP Type C2K Increased Safety (Type 'e') cable gland for use in Zone 1, Zone 2,
Zone 21 and Zone 22 Hazardous Areas with all types of armoured cable providing
an environmental seal on the cable outer sheath. The cable gland being suitable for
CMP Type A2F Triple Certified Flameproof (Type 'd'), Increased Safety (Type 'e') use with amoured cables provides mechanical cable retention and electrical
and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in continuity via armour wire termination. A reversible armour cone and AnyWay
Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured and universal clamping ring arrangement allows the cable to be easily disconnected
braided cable providing a combined flameproof seal and environmental seal on from the equipment, for maintenance and change out etc. This feature also
the cable outer sheath. This product provides full compatibility with restricted facilitates remote make off procedures when the termination is to be conducted in
breathing equipment that rely upon flammable gases being excluded from the main confined spaces or in areas of restricted access.
enclosure.
The CMP C2K Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are
The CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition
protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection, prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
installation and maintenance is observed, e.g. IEC 60079-14.

APPROVAL DETAIL TECHNICAL DATA


APPROVAL DETAIL TECHNICAL DATA ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, DELUGE PROTECTION : DTS01:91
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II, Ex e II, Ex nR II, Ex tD A21 IP66 CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour
CABLE TYPE : Unarmored & Braided
Ex nR II, Ex tD A21 IP66 IECEx : IECEx SIR 06.0042X (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire
SEALING AREA (S) : Cable Outer Sheath
IECEx : IECEx SIR 06.0040X Ingress Protection : IP66, IP67, IP68 Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Screened
Ingress Protection : IP66 Additional Approvals Held : GOST R (POCC GB. ГБ06.B00207), Flexible Wire Braid (e.g. CY / SY), Armored & Jacketed
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS SEALING AREA (S) : Cable Outer Sheath
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS, INMETRO

8 9

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

Increased Safety Ex e Cable Gland PX2KX-REX Flameproof Ex d, Increased Safety Ex e,


CWE PX2KX-REX Restricted Breathing Ex nR Resin Barrier Cable Gland
CMP Type CWe Increased Safety (Type 'e') cable gland for use in Zone 1, Zone 2,
Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable
providing an environmental seal on the cable outer sheath. The cable gland being RapidEx is the revolutionary method for installing barrier glands. The gland utilises a
suitable for armoured cables, provides mechanical cable retention and electrical liquid pour resin seal, that vastly reduces installation time and associated costs. This
continuity via armour wire termination.A detachable armour cone and AnyWay solution is particularly effective on multicore cables where traditional compound is difficult
universal clamping ring arrangement allows the cable to be easily disconnected and time consuming to apply.
from the equipment, for maintenance and change out etc., and re-connected with CMP Type PX2KX-REX Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’)
the same consummate ease. This feature also facilitates remote make off and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and
procedures when the termination is to be conducted in confined spaces or in areas Zone 22 Hazardous Areas with all types of braid cable providing a RapidEx barrier seal
of restricted access. around the cable conductors and an environmental seal on the cable outer sheath.

The CMP CWe Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are All CMP Cable Connectors are EMC Tested.The cable gland provides mechanical cable
retention and electrical continuity via armour termination. A combined detachable armour cone and resin tube, together with AnyWay universal
equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition
clamping ring arrangement allows the cable to be easily disconnected from the equipment, for maintenance and change out etc., and re connected
prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14. with the same consummate ease. This feature also facilitates remote make off procedures when the termination is to be conducted in confined spaces
or in areas of restricted access. The CMP PX2KX-REX cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone
APPROVAL DETAIL TECHNICAL DATA 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C
ATEX Code of Protection Category : II 2 GD, Ex e II, CABLE TYPE : Single Wire Armour (SWA)
Ex tD A21 IP66
APPROVAL DETAIL TECHNICAL DATA
SEALING AREA (S) : Cable Outer Sheath
ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +85°C
IECEx : IECEx SIR 06.0042X
ATEX Code of Protection Category : II 2/3 GD, Ex d IIC, Ex e II,
CABLE TYPE : Single Wire Armour (SWA), Aluminium Wire Armour (AWA),
Ingress Protection : IP66
Ex nR II, Ex tD A21 IP66: IM2 Ex d I, Ex e I
Additional Approvals Held : GOST R (POCC GB. ГБ06.B00207), Wire Braid Armour (e.g. SWB), Screened Flexible Wire Braid (e.g. CY / SY),
IECEx : IECEx SIR 06.0044X Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS Ingress Protection : IP66, IP67, IP68
Additional Approvals Held : GOST R (POCC GB.HO06.B00207), SEALING AREA(S) : Inner RapidEx Resin Barrier & Outer Sheath
INMETRO, ABS, DNV, LLOYDS, NEPSI, cCSAus
Increased Safety Ex e Cable Gland
CXe
CMP Type CXe Increased Safety (Type 'e') cable gland for use in Zone 1, Zone 2,
Zone 21 and Zone 22 Hazardous Areas with Braided, Pliable Wire Armour (PWA), TMC2 Ordinary, Wet & Hazardous Location Cable Connector
Strip Armour and Steel Tape Armour (STA) cable providing an environmental seal TMC2
on the cable outer sheath. The cable gland being suitable for armoured cables,
CMP Type TMC2 Cable Connector suitable for use with Interlocked & Continuously Welded
provides mechanical cable retention and electrical continuity via armour wire Metal Clad (Type MC or MC-HL) or TECK armored & jacketed cables in ordinary, wet &
termination. A detachable armour cone and AnyWay universal clamping ring hazardous locations including:
arrangement allows the cable to be easily disconnected from the equipment, for
maintenance and change out etc., and re-connected with the same consummate * Certified to CSA, UL, ATEX (EN) & IECEx Standards
ease. This feature also facilitates remote make off procedures when the termination * Class I Division 2, where permitted by code
* Class 1 Zone 1 AEx e and Ex e, where permitted by code
is to be conducted in confined spaces or in areas of restricted access.
* Ingress Protection to Nema 4X and IP68
The CMP CXe Cable Gland is suitable for use with Increased Safety Type e and Flameproof Type d enclosures that are
equipped with a secondary Increased Safety Type e terminal enclosure (i.e. Ex de) provided always that no source of ignition All CMP Cable Connectors are EMC Tested. The 2-part design allows the grounding and over
jacket sealing to be actioned in a single simple movement and allows he cable to be easily
prevails and the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.
removed from the equipment, for maintenance and change out etc. The TMC2 cable connector is supplied in Copper free (<0.4%), Aluminium,
Stainless Steel, or Electroless Nickel Plated Brass in NPT (standard) and Metric thread forms.

APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA06ATEX1097X, SIRA07ATEX4326X TEMPERATURE RATING : -60°C TO +130°C APPROVAL DETAIL TECHNICAL DATA
ATEX Code of Protection Category : II 2 GD, Ex e II, CABLE TYPE : Wire Braid Armour (e.g. SWB), Screened Flexible Wire ATEX : SIRA09ATEX1164X TEMPERATURE RATING : -60°C TO +110°C
Ex tD A21 IP66 Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour ATEX Code of Protection Category : II 2 GD, Ex d IIC Gb, Ex e IIC Gb, CABLE TYPE : Corrugated & Interlocked Metal Clad Armor
IECEx : IECEx SIR 06.0042X (STA), Strip Armour (e.g. ASA) Ex ta IIIC Da (MC) or TECK, Continuously Welded Metal Clad Armor (MCHL)
SEALING AREA (S) : Cable Outer Sheath IECEx : IECEx SIR 09.0068X SEALING AREA (S) : Cable Outer Jacket
Ingress Protection : IP66
Additional Approvals Held : cCSAus, GOST R (POCC GB.HO06.B00207),
Additional Approvals Held : GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 75000361 01 01 14761), ABS, DNV
GOST K (KZ 7500361.01.01.14761), INMETRO, ABS, DNV, LLOYDS

Ordinary, Wet & Hazardous Location Cable Connector TMC2X Ordinary, Wet & Hazardous Location Cable Connector
C2KX TMC2X
CMP Type TMC2X Cable Connector is suitable for use with Interlocked & Corrugated Continuously
CMP C2KX Cable Connector suitable for use with Armored & Jacketed Welded Metal Clad (Type MC or MC-HL) or TECK armored and armored & jacketed cables in
cables incorporating Wire Braid Armor in Ordinary, Wet & Hazardous ordinary, wet & hazardous locations including:

Locations. * Certified to CSA, UL, ATEX (EN) & IECEx Standards


* Class I Division 1 & Class 1 Division 2 ABCD
The cable connector provides mechanical retention and electrical * Class 1 Zone 1 AE d/Ex d, in accordance with NEC/CEC installations
continuity via the armor termination and is available in NPT (standard) or * Class 1 Zone 1 Ex d IIC for ATEX/IEC & IEC Ex installation codes
* Ingress Protection to Nema 4X and IP66
Metric thread forms. Standard material is Brass grade CuZn39Pb3
(CW614N) to EN12168 with Electroless Nickel Plated Brass entry All CMP Cable Connectors are EMC Tested. The TMC2X utilizes CMP’s innovative RAPID Ex Fast
Curing Liquid Compound Injection System, which installs in seconds, significantly reducing
component. installation error, with a complete 100% cure time of 1 hour, which significantly reduces installation
times. The new 2-part design allows the grounding and over jacket sealing to be actioned in a single simple movement and allows the cable to be
This product provides Nema 4X and IP68 ingress protection and is UL listed for use in Class I Zone 1 AEx e II easily removed from the equipment, for maintenance and change out etc. The TMC2X cable connector is supplied in Copper Free (<0.4%) Aluminium,
applications and can be used in Class I Division 2 areas when installed in compliance with the NEC requirements. Stainless Steel, or Electroless Nickel Plated Brass in NPT (standard) and Metric thread forms.

APPROVAL DETAIL TECHNICAL DATA APPROVAL DETAIL TECHNICAL DATA


ATEX : SIRA09ATEX1165X TEMPERATURE RATING : -60°C TO +100°C
ATEX : SIRA06ATEX1097X TEMPERATURE RATING : -60°C TO +130°C
ATEX Code of Protection Category : II 2 GD, Ex d IIC, Ex e IIC Gb, CABLE TYPE : Continuously Welded Metal Clad Armor (MCHL),
ATEX Code of Protection Category : II 2 GD, Ex e II, Ex tD A21 IP66 DELUGE PROTECTION : DTS01:91
Ex ta IIIC Da Corrugated & Interlocked Metal Clad Armor (MC) or TECK
IECEx : IECEx SIR 06.0041X CABLE TYPE : Armored & Jacketed
IECEx : IECEx SIR 09.0069X SEALING AREA (S) : Inner Compound Barrier & Cable Outer Jacket
Ingress Protection : IP66, IP67, IP68 SEALING AREA (S) : Cable Outer Jacket
Additional Approvals Held : cCSAus, GOST R (POCC GB.HO06.B00207),
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), GOST K
GOST K (KZ 75000361 01 01 14761), ABS, DNV, LLOYDS
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
10 11

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN SAFE AREAS SEALING CABLES IN SAFE AREAS

BW Cable Gland E2U Cable Gland


BW E2U
CMP BW type brass indoor cable gland for use with all types of Single Wire Armour (SWA) CMP E2U type brass indoor & outdoor cable gland for use with all types of Lead Sheathed
cable providing mechanical cable retention and electrical continuity via armour wire and Armoured cables providing an environmental seal on the inner lead sheath and on the
termination. cable outer sheath. The cable gland provides mechanical cable retention and electrical
continuity via the armour termination and also earth bonding of the inner lead covering or
CMP BWL type is also available, this design benefits from a longer body to protect the lead sheath.
armour wires from impact.

CX CX Cable Gland E1W Cable Gland


E1W
CMP CX type brass indoor & outdoor cable gland for use with all types of Wire Braid CMP E1W type brass indoor & outdoor cable gland for use with Single Wire Armour (SWA)
Armour, Strip Armour, Pliable Wire Armour & Steel Tape Armour (STA) cable providing an cables providing an environmental seal on the cable inner sheath and on the cable outer
environmental seal on the cable outer sheath. sheath. The cable gland provides mechanical cable retention and electrical continuity via the
armour termination.
The cable gland also provides mechanical cable retention and electrical continuity via
armour wire termination.

CW CW Cable Gland E2W Cable Gland


E2W
MP CW type brass indoor & outdoor cable gland for use with all types of Single Wire CMP E2W type brass indoor & outdoor cable gland for use with all types of Lead Sheathed
Armour (SWA) cable providing an environmental seal on the cable outer sheath. and Single Wire Armour (SWA) cable providing an environmental seal on the cable inner
lead sheath and on the cable outer sheath. The cable gland provides mechanical cable
The cable gland also provides mechanical cable retention and electrical continuity via retention and electrical continuity via the armour termination and also earth bonding of the
armour wire termination. inner lead covering or lead sheath.

A2 Cable Gland E1X Cable Gland


A2 E1X
CMP A2 type brass indoor & outdoor cable gland for use with all types of Unarmoured CMP E1X type brass indoor & outdoor cable gland for use with Wire Braid Armour, Strip
cable, providing mechanical cable retention and an environmental seal on the cable outer Armour, Pliable Wire Armour & Steel Tape Armour (STA) cables providing an environmental
sheath. seal on the cable inner bedding and cable outer sheath. The cable gland provides
mechanical cable retention and electrical continuity via the armour termination.

SS2KGP Cable Gland E2X Cable Gland


SS2KGP E2X
Unarmoured cable, providing mechanical cable retention and an environmental seal on the CMP E2X type brass indoor & outdoor cable gland for use with all types of Lead Sheathed
cables inner and outer sheath, or a double seal on the cable outer sheath. and Wire Braid Armour, Strip Armour, Pliable Wire Armour & Steel Tape Armour cable
providing an environmental seal on the cable inner lead sheath and cable outer sheath.
Suitable for applications where superior cable pull out resistance is required. The cable gland provides mechanical cable retention and electrical continuity via the armour
termination and also earth bonding of the inner lead covering or lead sheath.

S2KGP/PB Cable Gland A2DG Dome Top Cable Gland


SS2KGP/PB A2DG
CMP SS2KGP/PB type brass indoor & outdoor cable gland for use with all types of Lead CMP A2DG type indoor and outdoor non-metallic Dome Cap cable gland for use with all
Sheathed Unarmoured cable, providing mechanical cable retention and an environmental types of Unarmoured cables, providing an environmental seal on the cable outer sheath.
seal on the cables inner lead sheath and cable outer sheath. A2DG cable glands are available in various colours and are supplied complete with
locknut. Standard thread forms are metric to EN 60423. Standard versions are produced in
The cable gland also provides earth bonding of the inner lead covering or lead sheath. Low Smoke and Fume (LSF) polymeric materials with UL 94 V2 rating. Alternative versions
are available in Red coloured Flame Retardant, Low Smoke and Fume (LSF) and Halogen
Free polymeric material with UL 94 V0 rating.

E1U E1U Cable Gland A2 200 A2 200 Hex Head Series Cable Gland

CMP E1U type brass indoor & outdoor cable gland for use with all types of armoured Unarmoured cables, providing an environmental seal on the cable outer sheath. The A2 200
cables providing an environmental seal on the cable inner bedding and on the cable outer Hex Head cable glands are available in various colours and are supplied complete with a
sheath. locknut. Standard thread forms are metric to EN 60423. Standard versions are produced in
Low Smoke and Fume (LSF) polymeric materials with UL 94 V2 rating. Alternative versions
The cable gland provides mechanical cable retention and electrical continuity via the armour are available in Red coloured Flame Retardant, Low Smoke and Fume (LSF) and Halogen
termination. Free polymeric material with UL 94 V0 rating.

12 13

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

Thread Conversion Adaptor & Reducer Type 737 Unions Type 780
TYPE 737 TYPE 780
The CMP Type 737 range of Thread Conversion Adaptors & Reducers are designed The CMP Type 780 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated
to provide flexibility and versatility in the execution of construction works when there cable glands, to any fixed equipment. The 780 Union provides a running connection by means of an integral
is a conflict between the type or size of the cable gland thread and the cable entry coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct
hole in the equipment. These Thread Conversion Adaptors & Reducers are available termination. The ease of installation offered by the 780 Union consequently makes the process of removing the
with Male to Female connection threads and can be supplied with thread conversion conduit or other terminated cable entry device from the equipment a simple, fast and effective one.
between the forward and rear threads to either an increased or reduced size or a Available in Brass, Aluminium or Steenless Steel these Unions are approved for use in conjunction with Ex d and
different thread type, e.g. Metric to NPT, or NPT ro Metric. Ex e certified equipment and cable entry devices, and can also be supplied with thread conversion between the
forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to NPT, or
TECHNICAL DATA
NPT to Metric. A General Purpose Industrial version is also available.
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X
ATEX Code of Protection Category: II 2 GD, Ex d IIC, Ex e II,
TECHNICAL DATA
Ex tD A21 IP66, IM2 Exd I Exe I
ATEX : SIRA10ATEX/306U
IECEx : IECEx SIR 07.0083X
ATEX Code of Protection Category: II 2 GD, Ex d IIC Gb
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
Ex e II Gb Ex ta III C Da IP6x Component, Zone 1,2,21 & 22 -
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
Gas Groups IIA, IIB, IIC
IECEx : IECEx SIR 05.004U
Additional Approvals Held : CSA, UL, GOST R (POCC GB.
ГБ06.B00207), GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
Stopper Plugs Types 747,757,767
TYPE 747/757/767
Component approved Stopper Plugs designed to close unused cable entry holes in Adaptors Type 797
explosion protected equipment. Versions available with and without integral “O” Ring
seal & in various materials. Also for industrial and safe area use.
TYPE 797
The CMP Type 797 Male to Male and Female to Female Adaptor is designed to convert an existing enclosure
TECHNICAL DATA aperture to the opposite male or female thread form. These Male to Male & Female to Female Adaptors can
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X also be supplied with thread conversion between the two threads to either a reduced size or a different thread
ATEX Code of Protection Category: II 2 GD, Ex d IIC, Ex e II, type, e.g. Metric to NPT, or NPT to Metric. A General Purpose Industrial version is also available.
Ex tD A21 IP66, IM2 Exd I Exe I
IECEx : IECEx SIR 07.0083X
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207),
The CMP Type 797 Male to Male and Female to Female Adaptors are available in Brass, Aluminium or
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS Stainless Steel and can be supplied for both Industrial and Hazardous Area applications, with Ex ‘d’ & Ex e
Component and Equipment Approval.

TECHNICAL DATA
ATEX : SIRA05ATEX1233U
ATEX Code of Protection Category: II 2 GD, Ex d IIC & Ex e II,
IM2 Exd I Exe I Component, Zone 1,2,21 & 22 - Gas Groups IIA, IIB, IIC
Breather/Drain Plug Type 781 IECEx : IECEx SIR 05.004U

TYPE 781 Additional Approvals Held : CSA, UL, GOST R (POCC GB. ГБ06.B00207),
GOST K (KZ 7500361.01.01.14761), ABS, DNV, LLOYDS
Designed for increased safety Ex e apparatus that is susceptible to condensation or
prone to moisture collection or ingress during normal operation. Designed to act both
as a drainage device when mounted in a bottom entry of the equipment, and also to
enable the inside air to breathe with the external environment under normal ambient Earth Tags Serrated Washers
and atmospheric conditions, whilst excluding further dust and moisture from
penetrating the enclosure. Type 781 is supplied complete with an integral entry
CMP slip on earth tags, installed between the Available in Stainless Steel as standard, these
thread “O” ring seal, and a castellated locknut to facilitate drainage from inside the
cable gland and equipment, provide an earth “shake-proof” Serrated Washers fitted internally
enclosure. A General Purpose Industrial version is also available.
bond connection as specified in BS6121:Part to the equipment and before a locknut act as an
TECHNICAL DATA 5:1993 and also complies with category anti-vibration device to prevent the cable gland
ATEX : SIRA01ATEX1284U, SIRA02ATEX1003X “B” rating specified in BS EN 50262:1999. or other cable entry device and locknut
ATEX Code of Protection Category: II 2 GD, Ex d IIC, Ex e II, Alternative materials are available. arrangement from inadvertently loosening in
Ex tD A21 IP66, IM2 Exd I Exe I service. Alternative materials are available.
IECEx : IECEx SIR 07.0083X
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), GOST K Locknuts
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS

Brass Locknuts are the recommended items used in securing brass cable glands, unions, adaptors, reducers,
and stopper plugs to a gland plate or into equipment.
Insulated Adaptor Type 777
TYPE 777 Aluminium versions are also available for use with CMP Aluminium Cable Glands to prevent the electrolytic
action of galvanic corrosion which can occur when dissimilar metals are coupled together.
The CMP Type 777 Insulated Adaptor allows the Metallic Cable Gland, and ultimately the cable armour, to be
effectively isolated from the equipment. The use of these Adaptors has proven to be an essential precaution in
areas where electromagnetic “noise” and circulating eddy currents “stray” around any vulnerable cable system.
Particularly relevant in Power Plants and in areas where highly sensitive instrumentation circuits are relied upon Shrouds
for inference free safety critical operations, the cable armour can still be connected to ground externally with
the use of an earth tag fitted between the cable gland and insulated adaptor. CMP manufactures a range of push on shrouds which are used to minimise the risk of dirt or foreign substances
gathering on the Cable Gland Body, and/or point of cable to gland interface. Standard shrouds are produced
This allows the user to design his system around a single point earthing strategy and allows the operator to in Black PVC and PCP. CMP LSF (Blue/Grey) shrouds are available from stock.
perform tests on the earth circuit without disconnection of the elements installed. A General Purpose Industrial
version is also available. PVC, PCP & LSF shrouds are also manufactured in alternative colours including Red and White to suit a variety
of customer requirements.
TECHNICAL DATA
ATEX : SIRA10ATEX1057U
ATEX Code of Protection Category: II 2 GD, Ex d IIC Gb /Exe IIC Gb / Ex ta
Entry Thread Seal
IIIC Da Component, Zone 1,2,21 & 22 - Gas Groups IIA, IIB, IIC
IECEx : IECEx SIR 05.004U To maintain the Ingress Protection rating between the equipment and cable gland it might be necessary to fit an Entry Thread Seal
Additional Approvals Held : CSA, GOST R (POCC GB. ГБ06.B00207), GOST K at the gland entry interdace. For Explosion Protected equipment it is essential to maintain the integrity of the degree of Ingress
(KZ 7500361.01.01.14761), ABS, DNV, LLOYDS Protection at which the equipment has been rated. Manufactured in 2mm thick white Nylon as standard and certified to EN
60529. As an alternative we are also able to offer Integral Thread “O” Ring Seals to cable glands, adaptors, reducers and
14 stopper plugs. 15

www.cmp-products.com www.cmp-products.com
SEALING CABLES IN HAZARDOUS AREAS SEALING CABLES IN HAZARDOUS AREAS

CABLE GLAND SELECTION GUIDELINES Selection Table Of Unarmoured Cable Glands Please replace “XX” in Ordering Reference with Cable Gland name i.e. A2
There are many factors to consider when selecting cable glands for industrial installations. Neglecting to pay due attention to some of these factors may cause
Available Entry Threads ‘C’ Cable
unnecessary anxiety at a future point in time when the equipment and cables have been delivered on site, but for example the cable glands have either been forgotten Cable Minimum Bedding Across Across Nominal Ordering
to be ordered or it is discovered that they are the incorrect type or size at the very point when they are needed the most. Good advice would be to allocate some value Gland Standard Option Thread Diameter Flats Corners Protrusion Reference
added planning and preparation time to the subject of cable gland selection so as to avoid the great inconvenience which is likely to occur at a critical point in time. In Size Length Length (Brass Metric)
the event that a user or contractor is in possession of a cable schedule that requires a cable gland selection and sizing process to be carried out, CMP Products would be Metric NPT NPT Min Min
more than happy to assist in carrying out this process at no cost to the enquirer. Please contact CMP Products for further information on this subject. 20S/16 M20 1/2” 3/4” 10.0 3.1 8.7 24.0 26.6 21.0 20S16XX1RA
Here is a summary of some aspects to carefully • Check whether an entry thread seal is required for 20S M20 1/2” 3/4” 10.0 6.1 11.7 24.0 26.6 21.0 20XX1RA
consider when selecting cable glands. IP66 (or IP67/IP68) conditions. 20 M20 1/2” 3/4” 10.0 6.5 14.0 27.0 30.0 24.0 20XX1RA
• Check whether fixing accessories such as locknuts and 25 M25 3/4” 1” 10.0 11.1 20.0 36.0 39.9 26.0 25XX1RA
• Identify the type of cable to be used.
serrated washers are required. 32 M32 1” 1 1/4” 10.0 17.0 26.3 41.0 45.5 27.0 32XX1RA
• Check the construction, size & material properties of
• Check whether earth tags are required.(**) 40 M40 1 1/4” 1 1/2” 15.0 23.5 32.2 50.0 55.4 28.0 40XX1RA
the cable.
• Check whether shrouds tags are required. 50S M50 1 1/2” 2” 15.0 31.0 38.2 55.0 61.0 29.0 50SXX1RA
When the cable is armoured, verify the following :- • Select a corresponding cable gland type from this
50 M50 2” 2 1/2” 15.0 35.6 44.1 60.0 66.5 30.0 50XX1RA
• Check the type and material of the cable armour (*) catalogue.
63S M63 2” 2 1/2” 15.0 41.5 50.0 70.0 77.6 30.0 63SXX1RA
• Check the short circuit fault current rating of the cable • For installations in Hazardous Areas, special
considerations should be taken into account to ensure 63 M63 2 1/2” 3” 15.0 47.2 56.0 75.0 83.2 30.0 63XX1RA
armour (**)
• Check the actual diameter of the inner bedding compliance with national or international codes of 75S M75 2 1/2” 3” 15.0 54.0 62.0 80.0 88.7 32.0 75SXX1RA
(where present) against this catalogue. practice. 75 M75 3” 3 1/2” 15.0 61.1 68.0 85.0 94.2 32.0 75XX1RA
• Check the actual diameter of the lead covering (where • Check whether a thread conversion adaptor / reducer 90 M90 3” 3 1/2” 15.0 66.6 79.4 108.0 120.7 44.0 90XX1RA
present) against this catalogue. is required to make the installation. 100 M100 4” - 15.0 76.0 91.0 123.0 137.8 48.0 100XX1RA
• Check the actual size of the overall cable diameter • Select corresponding adaptors or reducers from this 115 M115 - - 15.0 86.0 98.0 133.4 147.6 55.0 115XX1RA
against this catalogue. catalogue. 130 M130 - - 15.0 97.0 115.0 152.4 164.9 62.0 130XX1RA
• Check the size and type of armour or braid (where • Check whether any stopper plugs are required to
present) against this catalogue. close unused cable entries. All dimensions in millimetres
• Check any special environmental requirements in • Select corresponding stopper plugs from this
relation to corrosion protection. catalogue. Selection Table Of SWA Cable Glands Please replace “XXXX” in Ordering Reference with Cable Gland name i.e. E1FW
• Check the material of the mating electrical enclosures
Note (*) : If the cable armour is of a non standard material,
to eliminate dis-similar metals. Available Entry Threads ‘C’ Cable
e.g. Aluminium Wire Armour, it may be necessary to consider Cable Minimum Overall Cable Across Across Nominal Ordering
• Consider whether any protective plating is required to Bedding Armour Range
an alternative cable gland material, e.g. Aluminium. Gland Standard Option Thread Diameter Flats Corners Protrusion Reference
be applied to the cable gland. Diameter
• Check the type and size of the cable entry hole in the Size Length Length (Brass Metric)
Note (**) : For certain medium voltage and high voltage Metric NPT NPT Min Max Min Max Min Max Max Max
mating electrical equipment. cables where the fault current carrying capacity of the cable 20S/16 M20 1/2” 3/4” 15.0 3.1 8.7 6.1 11.5 0.90 1.00 24.0 24.4 58.5 20S16XXXX1RA
• Check the ingress protection rating of the electrical armour is greater than that of the standard earth tag it may
equipment or site standard 20S M20 1/2” 3/4” 15.0 6.1 11.7 9.5 15.9 0.90 1.25 24.0 26.6 58.5 20XXXX1RA
be necessary to consider a cable gland utilising the CMP
• Check whether a single seal or double seal cable 20 M20 1/2” 3/4” 15.0 6.5 14.0 12.5 20.9 0.90 1.25 30.5 33.3 60.5 20XXXX1RA
heavy duty Cast Integral Earth Lug (CIEL) option which can
gland is required. 25S M25 3/4” 1” 15.0 11.1 20.0 14.0 22.0 1.25 1.60 37.5 40.5 67.5 25XXXX1RA
be identified in the body of this catalogue.
25 M25 3/4” 1” 15.0 11.1 20.0 18.2 26.2 1.25 1.60 37.5 40.5 67.5 25XXXX1RA
32 M32 1” 1-1/4” 15.0 17.0 26.3 23.7 33.9 1.60 2.00 46.0 51.0 69.5 32XXXX1RA
HOW TO ORDER 40 M40 1-1/4” 1-1/2” 15.0 22.0 32.2 27.9 40.4 1.60 2.00 55.0 61.0 78.0 40XXXX1RA
50S M50 1-1/2” 2” 15.0 29.5 38.2 35.2 46.7 2.00 2.50 60.0 66.5 75.5 50SXXXX1RA
On each of the main product pages in this catalogue you will find a cable gland The table below is provided to allow the selection of alternative materials, thread 50 M50 2” 2-1/2” 15.0 35.6 44.1 40.4 53.1 2.00 2.50 70.0 78.6 80.5 50XXXX1RA
selection table which includes the part number, typically of a standard metric types, thread sizes and other options. 63S M63 2” 2-1/2” 15.0 40.1 50.0 45.6 59.4 2.00 2.50 75.0 83.2 91.5 63SXXXX1RA
product, for ordering purposes. 63 M63 2-1/2” 3” 15.0 47.2 56.0 54.6 65.9 2.00 2.50 80.0 89.0 92.0 63XXXX1RA
The part number is composed of the CMP Size, Type Number, and Standard Suffix.
75S M75 2-1/2” 3” 15.0 52.8 62.0 59.0 72.1 2.00 2.50 89.0 101.6 99.0 75SXXXX1RA
75 M75 3” 3-1/2” 15.0 59.1 68.0 66.7 78.5 2.00 2.50 99.0 111.1 102.0 75E1FW1RA
e.g. 1: 20 - E1W - Brass, with M20 entry thread e.g. 2 : 20 – E1FW – Nickel Plated Brass, with M20 entry thread
90 M90 3-1/2” 3-1/2”” 15.0 66.6 80.0 76.2 90.4 3.15 3.15 114.0 128.6 120.0 90XXXX1RA
100 M100 - - 15.0 76.0 91.0 86.1 101.5 3.15 4.00 123.0 138.0 148.0 100XXXX1RA
Size Type Standard Suffix ID Size Type Standard Nickel Plated 115 M115 - - 15.0 86.0 98.0 101.5 110.3 3.15 4.00 133.4 147.8 169.0 115XXXX1RA
Suffix ID Finish 130 M130 - - 15.0 97.0 115.0 114.2 123.3 3.15 4.00 146.1 161.9 183.0 130XXXX1RA
All dimensions in millimetres

Selection Table Of STA/Braided Cable Glands Please replace “XXXX” in Ordering Reference with Cable Gland name i.e. E1FX
20 E1W 1RA 20 E1FW 1RA 5 Available Entry Threads ‘C’ Cable Overall Cable Across Across
Cable Minimum Lead Sheath Armour Range Nominal Ordering
CMP Entry Thread Size Gland Standard Option Thread Diameter Flats Corners
Protrusion Reference
Cable Gland Supply Entry Thread Diameter
STD Options Material NPT / BSP / Size Length Length (Brass Metric)
Size & Type Type Type Imperial PG Metric
Suffix NPSM Metric NPT NPT Min Max Min Max Min Max Max Max
e.g. 20E1FW 1 - Gland RA D Deluge Seal 0 Brass 1A Metric 1A 1/2“ 7 3/8” - 20S/16 M20 1/2” 3/4” 15.0 3.1 8.7 6.1 11.5 0.90 1.00 24.0 24.4 58.5 20S16XXXX1RA
20S M20 1/2” 3/4” 15.0 6.1 11.7 9.5 15.9 0.90 1.25 24.0 26.6 58.5 20XXXX1RA
- 2 - Pack - B Brazilian 1 Aluminium 1 Imperial 1 5/8” 9 1/2“ 16
Certification 20 M20 1/2” 3/4” 15.0 6.5 14.0 12.5 20.9 0.90 1.25 30.5 33.3 60.5 20XXXX1RA
- - - 2 Nylon 2 PG 2 3/4“ 11 3/4“ 20 25S M25 3/4” 1” 15.0 11.1 20.0 14.0 22.0 1.25 1.60 37.5 40.5 67.5 25XXXX1RA
25 M25 3/4” 1” 15.0 11.1 20.0 18.2 26.2 1.25 1.60 37.5 40.5 67.5 25XXXX1RA
- - - 3 Mild Steel 3 NPT 3 1” 13.5 1” 25
32 M32 1” 1-1/4” 15.0 17.0 26.3 23.7 33.9 1.60 2.00 46.0 51.0 69.5 32XXXX1RA
- - - 4 Stainless Steel 4 BSP 4 1-1/4” 16 1-1/4” 32
40 M40 1-1/4” 1-1/2” 15.0 22.0 32.2 27.9 40.4 1.60 2.00 55.0 61.0 78.0 40XXXX1RA
Brass - Fully
- - - 5 5 NPSM 5 1-1/2” 21 1-1/2” 40 50S M50 1-1/2” 2” 15.0 29.5 38.2 35.2 46.7 2.00 2.50 60.0 66.5 75.5 50SXXXX1RA
Nickel Plated
50 M50 2” 2-1/2” 15.0 35.6 44.1 40.4 53.1 2.00 2.50 70.0 78.6 80.5 50XXXX1RA
- - - 6 N/A 6 BSPT 6 2” 29 2” 50
63S M63 2” 2-1/2” 15.0 40.1 50.0 45.6 59.4 2.00 2.50 75.0 83.2 91.5 63SXXXX1RA
Brass with Nickel 63 M63 2-1/2” 3” 15.0 47.2 56.0 54.6 65.9 2.00 2.50 80.0 89.0 92.0 63XXXX1RA
- - - 7 Plated Entry - - 7 2-1/2” 36 2-1/2” 63 75S M75 2-1/2” 3” 15.0 52.8 62.0 59.0 72.1 2.00 2.50 89.0 101.6 99.0 75SXXXX1RA
Component 75 M75 3” 3-1/2” 15.0 59.1 68.0 66.7 78.5 2.00 2.50 99.0 111.1 102.0 75XXXX1RA
90 M90 3-1/2” 3-1/2” 15.0 66.6 80.0 76.2 90.4 3.15 3.15 114.0 128.6 120.0 90XXXX1RA
- - - 8 Zinc Plated - - 8 3” 42 3” 75
100 M100 - - 15.0 76.0 91.0 86.1 101.5 3.15 4.00 123.0 138.0 148.0 100XXXX1RA
- - - - - - 9 3-1/2” 48 3-1/2” 90 115 M115 - - 15.0 86.0 98.0 101.5 110.3 3.15 4.00 133.4 147.8 169.0 115XXXX1RA
- - - - 10 4” 4” 100 130 M130 - - 15.0 97.0 115.0 114.2 123.3 3.15 4.00 146.1 161.9 183.0 130XXXX1RA
“Unless otherwise stated, for IEC products, the standard Hazardous Area certification marking includes ATEX and IEC Ex as a minimum – All dimensions in millimetres
16 please refer to CMP Products if your requirement differs from the standard” 17