Advantages
+ Very high efficiency
+ Very low pulsation
+ Very low noise emission
+ Robust and compact
+ Multiple flow capable
Design and function
1 Pinion shaft
2 Internal gear
3 Filler pin
4 Filler segment
5 Axial disc
6 Control piston
7 Radial pressure area
8 Axial pressure area
9 Housing
10 End cover with bleeder screw
Suction chamber
Pressure chamber
1 8 5 6 2 9 58 10 2 1 7 6 4 7 3
Function Calculations
Rotation of the gears within the pump draws in the pressure Pump flow Q = Vg th · n · ηv · 10-3 [l / min]
fluid (usually hydraulic oil) into the space between the pinion
Q · Δp
and internal gear. The two smooth running gears help to Power P= [kW]
600 · ηg
ensure excellent intake behavior.
Vg th pump volume per revolution [cm3]
In the radial direction, the gear chambers are sealed by gear n Speed [rpm]
meshing and the filler piece. In the axial direction, the axial ηv Volumetric efficiency
plates seal the pressure chamber with the minimal possible ηg Overall efficiency
gap. This design minimizes volume losses and increases Δp Differential pressure [bar]
efficiency. When the gears rotate, the pinion teeth enter the
gaps between the internal gear teeth and displace the
pressure fluid.
2
Technical data
Design Internal gear pump with radial and axial sealing gap compensation
Type IPH
Shaft load for details of radial and axial drive shaft loads please contact
J.M. Voith SE & Co. KG
Input pressure suction side 0.8…3 bar absolute pressure (at start up for short time 0.6 bar)
Required purity of the pressure fluid Class 19/17/14 (ISO 4406), Class 8 (NAS 1638)
Filtration filtration quotient min. β20 ≥ 75, recommended β10 ≥ 100 (longer life)
Characteristics
Displacment per Delivery at Continuous
revolution Speed min. Speed max. 1 500 rpm pressure Peak pressure
Type. size –
delivery [cm3] [min-1] [min-1] [l/min] [bar] [bar]
speeds
• Due to production tolerances. the pump volume may be
reduced by up to 1.5 %.
3
IPH Size 4, Rotation and dimensions
Rotation
6 22 172
clockwise (cw)
0.3 ± 0.15 77 73* 13 M10x15 146
8 h9
8.7
81
13.5
47.5
g
28
66.3
25 h7 37
h8
6
20 c/2 c/2 e
1.
M8x16 Z
10
ø
Rotation counter-
c
clockwise (ccw)
l h
k
i
* Ensure the M10x1plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm during pumping operation.
Dependent on the pump position, filling or ventilation is possible here prior to commissioning.
4
IPH Size 4, Designs and dimensions
Rotation, Suction port Mounting flange Shaft end
Standard
Rotation clockwise, SAE 2-hole flange Keyway connection
radial suction port
20 64.5
1
0 1
64.5
72.5 72.5
Variants
Rotation counterclockwise, Involute gearing with
radial suction port SAE-2-hole-flange
64
6
0
ANSI B92.1a
13T
72
16 / 32 DP 30 °
64.5 101.6 h8
13
12 42.5
8 h9
ø 78
1 1
28
90
124
25 h7
6
64.5
90
42.5 50 122
42
1
ANSI B92.1a
64 13T
16 / 32 DP 30 °
* Direction of rotation free selectable in the illustrated mounting flange / shaft end combination.
5
IPH Size 5, Rotation and dimensions
Rotation
6 26.2 210
clockwise (cw)
0.3 ± 0.15 95 98 18 M10x15 181
10 h9
11.2
109
17.5
52.4
g
35
86.3
32 h7 44
h8
7
12
22 c/2 c/2 e M12x25 Z
ø
Rotation counter-
clockwise (ccw) c
l h
k
i
* Ensure the M10x1plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm during pumping operation.
Dependent on the pump position, filling or ventilation is possible here prior to commissioning.
6
IPH Size 5, Designs and dimensions
Rotation, Suction port Mounting flange Shaft end
Standard
Rotation clockwise, SAE 2-hole flange Keyway connection
radial suction port
22 80
1
0 1
80
89 89
Variants
Rotation counterclockwise, Involute gearing with
radial suction port SAE-2-hole-flange
80
0
ANSI B92.1a
89 14T
12 / 24 DP 30 °
80 ø 127 h8
16
56
10 h9
1 1
ø 100
ø 162
189
35 32 h7
6 80
17.5
56 55 189
56
1
ANSI B92.1a
80 14T
12 / 24 DP 30 °
* Direction of rotation free selectable in the illustrated mounting flange / shaft end combination.
7
IPH Size 6, Rotation and dimensions
Rotation
5 35.7 264
clockwise (cw)
0.3 ± 0.2 120 121 20.5 M12x20 228.6
12 h9
13.7
135
22
69.9
g
43
106.3
40 h7 61
h8
4
2.
26.5 c/2 c/2 e
15
M12x25 Z
ø
Rotation counter-
clockwise (ccw) c
l h
k
i
* Ensure the M10x1plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm during pumping operation.
Dependent on the pump position, filling or ventilation is possible here prior to commissioning.
8
IPH Size 6, Designs and dimensions
Rotation, Suction port Mounting flange Shaft end
Standard
Rotation clockwise, SAE 2-hole flange Keyway connection
radial suction port
26.5 104
1
0 1
104
112.5 112
Variants
Rotation counterclockwise, Involute gearing with
radial suction port SAE-2-hole-flange
104
0
ANSI B92.1a
112.5 13T
12 / 24 DP 30 °
1 1
ø 130
264
43 40 h7
6 104
22
75.5 63 264
75.5
1
ANSI B92.1a
104 13T
12 / 24 DP 30 °
* Direction of rotation free selectable in the illustrated mounting flange / shaft end combination.
9
Measurement values – Airborne noise level Measurement values – Efficiency ηv and ηg
IPH 4 IPH 4
7050 100
ηv
95
45
65
90
Airborne noise level dB(A)
40 ηg
60 85
35
80
Efficiency %
55
30 75
5025 70
50 00 50
50 100
100 150
150 200
200 250
250 300
300 350
350 0 50 100 150 200 250 300 350
Operating pressure p [bar] Operating pressure p [bar]
IPH 5 IPH 5
75
100 100
ηv
95
90
70
90
ηg
Airborne noise level dB(A)
80
65 85
70
80
Efficiency %
60
60
75
55
50 70
0 50
50 100
100 150
150 200
200 250 300 350 0 50 100 150 200 250 300 350
Operating pressure p [bar] Operating pressure p [bar]
IPH 6 IPH 6
80
210 100
ηv
95
190
75
90
ηg
Airborne noise level dB(A)
170
70 85
150
80
Efficiency %
65
130 75
60
110 70
0 00 50
50 100
100 150
150 200
200 250
250 300
300 350
350 0 50 100 150 200 250 300 350
Operating pressure p [bar] Operating pressure p [bar]
IPH 6 – 80 IPH 6 – 100 IPH 6 – 125 IPH 6 – 80 IPH 6 – 100 IPH 6 – 125
10
Measurement values – Delivery Q Measurement values – Input power P
IPH 4 IPH 4
50 30
100 70
25
95
45
65
20
90
40
15
85 60
Delivery Q in l / min
35
Power P in kW
10
80
55
30 755
25 700 50
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Operating pressure p [bar] Operating pressure p [bar]
IPH 5 IPH 5
100 60
100
95
50
90
40
90
80
30
85
Delivery Q in l / min
70
20
80
Power P in kW
60 10
75
50 0
70
0 50 100 150 200 250 300 350 00 50
50 100
100 150
150 200
200 250
250 300
300 350
350
Operating pressure p [bar] Operating pressure p [bar]
IPH 6 IPH 6
210 100
120 80
10095
190
75
8090
170
6085 70
Delivery Q in l / min
150
4080
Power P in kW
65
130 2075
110 070 60
0 50 100 150 200 250 300 350 0 0 50 50 100100 150150 200200 250250 300300 350350
Operating pressure p [bar] Operating pressure p [bar]
IPH 6 – 80 IPH 6 – 100 IPH 6 – 125 IPH 6 – 80 IPH 6 – 100 IPH 6 – 125
11
Suction and pressure flange according to SAE...
1)
2)
Wrench torque for screws according to ISO 6162
1)
Screw EN ISO 4762
A
C
i
2)
Round seal ring (O-Ring) ISO-R 1629 NBR
3)
Special design. Deviation from SAE J 518 C Code 61
k D
B
12
Multi-flow pumps, pump combinations
• are available as two or three-flow pumps; four-flow pumps in the illustration above.
must be designed by Voith. • If identical types or identical sizes follow each other,
• The pumps are arranged in increasing order according to the pump with the higher pump flow is placed closer
size and delivery. to the drive.
13
Designs
1 6
1 6 0 1 1 0
3 8
0 SAE-2-hole-flange
Special design 4 9 Special design
1 SAE-4-hole-flange
14
Allowed input torques A B
Size A B
[Nm] [Nm]
4 450 300
5 800 540
6 1 350 800
Type code
IPH 5 - 50 1 0 1
Shaft end
0 Splined gear shaft ANSI B92.1a
1 Parallel shaft with keyway
Mounting flange
0 SAE-2-hole
1 SAE-4-hole
Delivery
Size Delivery
4 20 25 32
5 40 50 64
6 80 100 125
Size
Type
15
90115-IPH-PDS-EN-210224. BDI. All data and information without obligation. Subject to change.
This is a translated document
Original language: German.
Legally binding language version of the document: German.
3159-000107-DSH-DEX-00
www.voith.com/hydraulics