Annual Production Report produced by Reymart Galleros

Design 1 Residential Building, 9.600089, 124.124659


 Report  System Metrics  Project Location

Project Name Residential Building Design Design 1

Project Description solar design for residential Module DC


22.6 kW
Nameplate
Project Address 9.600089, 124.124659
Inverter AC 26.4 kW
Reymart Galleros
Nameplate Load Ratio: 0.86
Prepared By
reymart.galleros@bisu.edu.ph
Annual
25.92 MWh
Production

Performance
68.7%
Ratio

kWh/kWp 1,146.9

TMY, 10km Grid, meteonorm


Weather Dataset
(meteonorm)

2aaf7fc180-1dcd5fd28b-7a12997c74-
Simulator Version
47109fc418

 Monthly Production  Sources of System Loss

3k
AC System:
System: 0.1% Shading: 0.6%
Shading:
Inverters: 4.0%
Inverters: Reflection: 3.3%
Reflection:

Clipping: 0.0%
Clipping: Soiling: 2.0%
Soiling:
2k
Wiring: 0.4%
Wiring: Irradiance: 0.7%
Irradiance:
kWh

Mismatch: 9.2%
Mismatch:
1k

Temperature: 15.3%
Temperature:
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

© 2023 Aurora Solar 1/3 November 16, 2023


Annual Production Report produced by Reymart Galleros

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,692.7 Weather Dataset TMY, 10km Grid, meteonorm (meteonorm)
POA Irradiance 1,669.1 -1.4%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,659.8 -0.6%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,604.4 -3.3%
Irradiance after Soiling 1,572.3 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,572.6 0.0% Rack Type a b Temperature Delta
Nameplate 35,523.8 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 35,268.7 -0.7% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 29,881.0 -15.3% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 27,117.6 -9.2% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 27,015.4 -0.4%
J F M A M J J A S O N D
Constrained DC Output 27,014.9 0.0% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 25,935.4 -4.0%
Irradiation Variance 5%
Energy to Grid 25,920.3 -0.1%
Temperature Metrics Cell Temperature Spread 4° C

Avg. Operating Ambient Temp 28.9 °C Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 47.9 °C AC System Derate 0.50%
Simulation Metrics Uploaded
Module Characterization
Operating Hours 4628 By

Solved Hours 4628 Module Characterizations GSM-B50-200 Spec Sheet


HelioScope
(GermanSolar) Characterization, PAN
Spec Sheet
REC280TP (REC Solar) HelioScope
Characterization, PAN
Uploaded
Device Characterization
Component By
Characterizations Inverter 12.000W TL Default
HelioScope
(Beghelli) Characterization

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
Inverters Inverter 12.000W TL (Beghelli) 2 (26.4 kW) Wiring Zone 12 12-29 Along Racking
AC Home
12 AWG (Copper) 2 (147.5 ft)
Runs
 Field Segments
Home Runs 12 AWG (Copper) 3 (62.9 ft)
Intrarow Frame
Description Racking Orientation Tilt Azimuth Frames Modules Power
Combiners 1 input Combiner 2 Spacing Size
Combiners 2 input Combiner 1 Flush Landscape 8.40
Field Segment 1 18° 267.1626° 0.5 ft 1x1 30 30
Mount (Horizontal) kW
Strings 10 AWG (Copper) 4 (80.4 ft)
Field Segment 1 Flush Landscape 7.20
55 (15.4 18.4° 86.863594° 0.5 ft 1x1 36 36
Module REC Solar, REC280TP (280W) (copy) Mount (Horizontal) kW
kW)
Flush Landscape 7.00
GermanSolar, GSM-B50-200 36 (7.20 Field Segment 3 19.5° 177.73596° 0.5 ft 1x1 25 25
Module Mount (Horizontal) kW
(200W) kW)

© 2023 Aurora Solar 2/3 November 16, 2023