TIME LINE PROJECT REPLACEMENT AIR CONDITONER NEW UNIT PACKAGE & CEILING TYPE APPROVED BY CHECKED BY MADE BY

PT. INDONESIA NIPPON SEIKI

YEAR 2022
NO JOBS DESCRIPTION MONTH MARCH APRIL MAY JUNE JULY
REMARKS
DATE 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

1 PAC- PIS B - 002 (INJECTION ROOM FACTORY. B)


LIBUR IDUL FITRI 1443 H
~UNINSTAL OLD UNIT PACKAGE AC
~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACCUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

2 PAC - PCB B - 004 (SMT & MEET ROOM FACTORY .B )

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

3 PAC - PRS 1 - B - 001 ( PRINTING MANUAL ROOM FACTORY. B )

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

4 PAC - PRS 1 - B - 005 ( SUB ASSY ROOM PRINTING FACTORY. B)

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

5 PAC - PRS 1 - B - 003 (OVEN PRINTING MANUAL ROOM FACTORY.B)

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

6 PAC - PRS 2 - B - 004 (OVEN PRINTING AUTO FACTORY. B)

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

7 PAC - PRS 2 - B - 003 (OVEN PRINTING AUTO FACTORY.B )

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACCUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

8 PAC - PRS2 - B - 001 ( PRINTING AUTO ROOM FACTORY. B )

~UNINSTAL OLD UNIT PACKAGE AC


~INSTAL NEW UNIT PACKAGE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACCUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

9 CAC - PRS 2 - B - 011 ( FINISH STOCK PRINTING ROOM FACTORY. B )

~UNINSTAL OLD UNIT CEILING CASSETE AC INDOOR - OUT DOOR


~INSTAL NEW UNIT CEILING CASSETE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACCUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST

10 CAC - PRS 2 - B - 012 (FINISH STOCK PRINTING ROOM FACTORY. B )

~UNINSTAL OLD UNIT CEILING CASSETE AC INDOOR - OUT DOOR


~INSTAL NEW UNIT CEILING CASSETE AC INDOOR - OUT DOOR
~INSTAL CUPER TUBE & WIRING ELECTRIC
~LEAK & PRESSURE TEST
~VACCUM SYSTEM
~INSERT NEW REFRIGRANT R410 TO SYSTEM UNIT
~RUNNING TEST