Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

QS-H150 ™

Handheld Explosives
Trace Detector

Simultaneous, real-time detection


of explosives particulates and vapors BENEFITS
with or without physical contact
› Detects explosives in seconds

The QS-H150 is a handheld explosives detector that rapidly detects and identifies trace
› Non-radioactive ion source
amounts of a wide variety of military, commercial, and homemade explosives (HMEs). › Choice of sampling modes:

The QS-H150’s innovative design includes a patented heated vortex collector and
› Simultaneous non-contact
particulate and vapor detection
patented non–radioactive ion mobility spectrometry technology. These provide
operational advantages that make the detector highly effective in real world situations › Wipe sampling
– advantages proven time and again in customer evaluations. › inCal automatic calibration
Operation and maintenance expenses are extremely low with the QS-H150. › Rapid clear-down
Consumables costs are greatly minimized. Routine maintenance consists only › Low total cost of ownership
of cleaning, using common supplies and desiccant replacement as required. › One-handed operation
No radioactive materials are used in the QS-H150, so there are no associated
certification, licensing, inspection, testing or decommissioning costs.

The QS-H150 is portable, easy-to-use, and offers the choice of collecting samples
directly from a surface or using sample traps. The system’s real-time detection
algorithm delivers fast results, alerting the operator as soon as a threat is detected.
It also minimizes system contamination, allowing the QS-H150 to be ready for the
next sample in seconds, even after a positive detection.

The presence of a threat is indicated by both visible and audible alarms, with the
substance identification displayed on the integrated LCD screen. A standard monitor
and USB keyboard may be connected at any time for access to spectrogram display
and analysis tools, administrative tools, and diagnostics.
The patented automatic calibration system, inCal™, prevents errors that could
result from an uncalibrated instrument. The QS-H150 monitors its environment,
senses changes that would affect its analysis, and recalibrates accordingly. No user
intervention, no calibration consumables, and no system down-time required.
SPECIFICATIONS

GENERAL CLEAR-DOWN TIME OPTIONAL FEATURES


Height: 18.8 cm (7.4") › 10 seconds or less (typical) › Vehicle battery charger
Width: 12.7 cm (5.0") › No user intervention › System vehicle adapter
Depth: 49.3 cm (19.4") SAMPLE ACQUISITION › Printing kit

Weight: 5.1 kg (11.3 lb) › Non-contact vapor collection OPERATING ENVIRONMENTAL


DETECTOR TYPE › Particulate collection via wiping Operating -10°C to 55°C
(wand or with gloved hand) Temperature: (14°F to 131°F)
Ion Mobility Spectrometry
ALARM METHOD Altitude: Up to 4,572 m
POWER REQUIREMENTS
(15,000ft)
› Configurable visual and audible alarms
AC Input: 100-240 VAC, 47-63Hz
› Substance identification by name Relative 0 to 95%,
DV Input: 15VDC, 15A via Humidity: non-condensing
battery (included) CONSUMABLE MATERIALS
SUBSTANCES DETECTED
DATA DISPLAY › L ow-cost molecular sieve drying agent
(desiccant) Military, commercial, and homemade
› Integrated LCD screen explosives (HMEs) including: ammonium,
› Connections for optional external
› Sample traps (if using particulate
nitrate, ANFO, black powder,
collection)
monitor & keyboard C-4, detasheet, detonating cord,
BATTERIES dinitrotoluene, DMNB, dynamite, EGDN,
WARM UP TIME
Less than 15 minutes (typical)
› Lithium Ion (Li-ion) rechargeable (2 ea) HMTD, HMX, nitroglycerin (NG), o-MNT,
p-MNT, peroxides, PETN, RDX, semtex,
› Up to 4 hours operating time per battery
ANALYSIS TIME smokeless powder, tetryl, triacetone
User-selectable, 5-30 seconds triperoxide (TATP), trinitrotoluene
(10 seconds default) (TNT), urea nitrate, and others.
Additional substances can be
added through the user-expandable
detection library

FOR MORE INFORMATION VISIT


leidos.com/security-detection

© Leidos. All rights reserved. The information in this document is proprietary to Leidos.
It may not be used, reproduced, disclosed, or exported without the written approval of Leidos.
20-leidos-0420-21554 | 20-144565 | Leidos Creative