CPU1000 Futura+

Advanced Multi-Function Power Transducer


Futura+
SERIES

with Remote Displays & Extensive Communication Capabilities

Power Monitoring
& Analysis
 True RMS Voltage,
Current, Power &
Energy

 Max & Min Demand

 Harmonic Analysis

 Waveform Scope I20.0


80.0
On-Board Data
Logging & Storage
 On-Board Historical
Trending

 On-Board Event
Recording

 On-Board Waveform
Recording
Description
 Power Quality with Voltage The Futura+ Series, CPU Comprehensive • kVAR Max/Min
Stability & Reliability 1000, is an advanced, easy- Measurements • kVA Max/Min
Recording
to-use multi-function electri- • Three Phase Voltage (L -N)
• PF Max/Min
 Current Fault Recording cal power monitor/transducer
• Three Phase Voltage (L - L)
that measures every aspect • Frequency Max/Min
of power including Voltage, • Three Phase Amps
• %THD Max
Current, Watts, VARs, VA, PF, • Neutral Current (Calculated)
Advanced Communication Freq. and Energy.
Capabilities From basic energy meter-
• Bidirectional kW
(Three Phase & Total) User Alarm Set Points
 Dual Digital Com Ports ing to advanced power quality • Over/Under Voltage
analysis, the CPU 1000 arms • Bidirectional kVAR
 Modbus & DNP 3.0 (Three Phase & Total) • Over/Under Current
you with sophisticated moni-
 10 Channel Analog toring capabilities. The unit’s • Bidirectional kVA • Over/Under kVA
Retransmits (0-1 or comprehensive on-board (Three Phase & Total)
4-20mA) • Over/Under kW
memory provides immediate • PF (Three Phase & Total)
 Up to 4 Remote access to historical, I/O and • Over/Under kVAR
Displays • Frequency
waveform recording. With the • Over/Under PF
M200 memory option, the unit • Bidirectional kWh
records up to 3 months of his- • Over/Under Frequency
• Bidirectional kVARh
torical data and 100 waveform • Over %THD
Utility Grade Design records. This makes the CPU • Bidirectional kVAh
 Optically Isolated • Phase Reversal
1000 one of the most prolific • %THD
Sensing Voltages
analysis devices at its pricing • Reverse Power
• Harmonics to the 31st Order
 Universal AC/DC Power point. • Logic & Hysteresis
Supply
The unit provides multiple
• Relay Output Control
 Meets ANSI C62.41 (6 paths of communication pro- Advanced
kV Voltage Burst), IEEE viding open protocol solutions. Measurements
SWC C.37.90.1 (Surge Built-In analog retransmits retro-
Withstand) •Voltage Max/Min
fit into existing analog milliamp
 Reliable in Harsh input based data collection. • Amps Demand Max/Min
Conditions
• KW Max/Min

Perfect for
Substation Panels

Electro Industries/GaugeTech
The Leader in Web Accessed Power Monitoring C
Power Quality/Harmonic Storage Capabilities
Analysis Recording*
Memory Historical I/O Event Stamping Waveform
The CPU 1000 conducts an Modules Recording**
110,000
extensive harmonic and power
quality analysis. The unit mea- M100 110,000 90 Days 255 for Relay and N/A
Snapshots  
sures and calculates harmonic Input Status
Contacts 
distortion to the 31st order
for each voltage and current M150 55,000 45 Days 255 for Relay and 25 Waveform
snapshots   Input Status Records
channel. Using the M150 and Contacts 
M200 memory modules, the
unit will record voltage distur- M200 110,000 90 Days 255 for Relay and 100 Waveform
snapshots   Input Status Records
bances such as surges, sags Contacts 
and transients.

Waveform Scope * Recording Time is Based on 10 Values Logged at 15 Minute Intervals.


** Each Record is 10 Cycles Prior/50 Cycles Post Event, All 6 Channels Simultaneously.
The unit also provides data  Snapshots Can be Configured to any Desired Time Interval from
1 Second to 2.5 Hours.
to build a graphical, real time  Both Instantaneous and Average Readings Stored.
depiction of each waveform  Must be Used with L200 I/O Module

channel. This allows the user


to view actual waveforms
for each voltage and current
channel using PC software. interval is programmable from and above current. When The M200 provides 110,000
1 second to 180 minutes. The the unit triggers a waveform snapshots of historical data,
default storage interval is 15 recording, it records 10 cycles full I/O event recording and
minutes. Using this module, prior and 50 cycles past the 100 waveform events consist-
you can trend any parameter event. All 6 channels are ing of 60 cycles of recording
such as kW usage, Voltage, recorded simultaneously. This for each event. This is a sig-
Watt/VAR distribution and any module provides 25 captured nificant amount of waveform
other desired parameter. waveform events and is a recording capability.
The event portion of the good economical choice for In addition, unique to this
memory, when used with the an advanced metering solu- design, the memory can be
Extensive On Board L200 I/O module, records tion. configured to store any desired
Memory when a status input or a relay amount of waveforms (in
The CPU 1000 is available output changes state. M200 Memory Module intervals of 60) when an event
with several different on-board – Advanced Memory occurs. You can program the
memory options allowing you The M200 module is the unit to record for long duration
M150 Memory Module
to choose the memory option — Historical, Event & Waveform Storage advanced memory module event or short duration events
that is necessary for your spe- This module provides his- offered in the CPU 1000 power depending on the application.
cific power monitoring applica- torical, event and waveform monitor. This module provides This is the memory of choice
tion needs. recording. The M150 offers significantly more memory for users who want to capital-
55,000 historical points and full capability. Using this memory ize on their investment. This
event recording. All memory is module, you are assured that memory is stored is a FIFO
M100 Memory Module your monitor is always record- buffer.
– Historical & Event Memory stored in a FIFO buffer.
ing and providing you with a
This module stores up to Additionally, the module
comprehensive analysis of
110,000 snapshots of informa- records waveforms based on
any occurrences in the power
tion per value in non-volatile RMS triggers. Set the meter to
distribution system.
mass memory. The storage trigger on above/below voltage

Display Modules

50.5
50.5 +
I o o 9 8 39
50. i
50.6

P11 P14/15 P31


A Single Function Digital Display Module P14: Displays Instantaneous Real Power Amps Module Displaying Phases A-B-C
Available for Every Function. (W), Total Kilowatt Hour (Wh) and Watt and N. Also Displays % THD for Each
Demand (WD). Reading.
P15: VAR/VARh/VARD. 6 1/2 Digit
Resolution.
Advanced Communication 10 Channel Analog Outputs
(0-1mA or 4-20mA) Physical Construction
Capabilities
Voltage Optical Isolation
Dual Digital The voltage inputs are opti-
Communication Ports PLC cally isolated. Issues such
Dual digital communication or RTU as noisy grounds, switching
ports allow communication noise, SWC or any other such
with RTUs, SCADA, PLCs, or problems pose no threat to
remote monitoring software the CPU 1000 meter. The input
using Modbus or DNP 3.0 structure is one of the safest
Built-In Analog Multiple Remote Displays
protocol. The first serial port and most durable designs
Transducer Outputs
allows for real time polling Choice of Display Modules available.
The CPU 1000 features 10
and data downloads using EI The CPU 1000 Series pro-
channels of analog transducer
protocol. The second port pro- vides a multitude of different
outputs replacing all exist- Case Construction
vides a Modbus RTU, Modbus display choices. Just select
ing transducers (0-1mA or Designed for harsh environ-
ASCII or DNP 3.0 output. the applicable display or
4-20mA.) Bidirectional as well ments, the unit is mounted
Using dual ports allows the combination of displays that
as unidirectional outputs are in a shielded metal case. It
unit to communicate to RTUs meet your individual applica-
available. The analog trans- offers no visible openings and
and other data collection sys- tion needs. Up to 4 displays
ducer signals are custom is resistant to contamination
tems in real time while having can be powered directly from
scalable and allow you to wire from harmful dust, sand or
an additional serial port avail- the CPU 1000’s power supply.
the meter to communicate other matter. All screws and
able for data downloads and The displays can be mounted
to any pre-existing data col- hardware are non-corrosive
remote interrogation. In this both locally and remotely (up
lection system. This is invalu- stainless steel.
manner, you are assured that to 4,000 feet from CPU 1000.)
able in retrofit applications.
the monitor is always available All displays are LED based to
Communicate analog now and Power Supply
for data collection even while ensure durability in harsh
upgrade to digital later. With The power supply offers both
communicating in real-time to conditions.
the CPU 1000 meter, you have primary MOV protection and
a third party system.
the best of both worlds. active line filtering to reduce
any damaging occurrences to
the supply. This design meets
ANSI C42.21 (Surge Test
6.0KV) and ANSI C37.90.1
(Surge Withstand Capability).

Communication Ports
All communication ports are
isolated from the main unit and
additionally isolated from each
other. This design avoids dan-
gerous ground loops.

i 20.0 +
i7.24 i2 0.0
i 20.0
+
5.64 50.5
i 20.0 +
I 8.I 4 60.00

P32 P33 P34


Volts Module Displays A-N, B-N, C-N Power Module Provides Values for KW, Multi-Function Digital Display with a
Phases, Total Harmonic Distortion and kVAR, VA and PF. Simultaneous 3 Phase Presentation of
Phase-to-Phase Readings. Voltage, Current, and Power. It Displays
%THD for Each Voltage and Current
Reading.
Specifications COMMUNICATION FORMAT
 Protocols: DNP 3.0, Modbus RTU/ASCII, EI Bus
COMPLIANCE
 ANSI/IEEE C37.901. Surge Withstand
INPUT VOLTAGE RANGE  1 Start Bit, 8 Data Bits, 1 Stop Bit; Programmable up  ANSI C62.41 Surge Immunity (6 KV)
 150V Phase to Neutral Standard* to 9600 Baud on Real Time Port, 38,400 Baud on  ANSI C12 Revenue Accuracy
 300V Phase to Neutral (OPTION G) Download Port  IEC 687 Revenue Accuracy
*Used with PTs for Extended Input Voltage. FREQUENCY RANGE
I/O ISOLATION Fundamental 45-75 Hz
Accuracy

 2500V AC 60 Hz AMBIENT TEMPERATURE


 Minimum isolation between any input to output of analog retransmitting module,  Operating -20ºC to +70ºC Parameters Accuracy* Range
digital communication module or relay output terminals.
CONSTRUCTION Volts & Current  0.15% 0-2000 
CONTROL POWER REQUIREMENTS  Metal Housing
 115V ±20%, 12VA (OPTION 115A) Watts & Energy  0.2% 0-2000 / 51/2
BURDEN
 230V ±20%, 12VA (OPTION 230A)
Per Element Digit Counter 
 24-48V DC, ±20%, 12VA (OPTION D)  Voltage 0.3VA MAX VA & VARs  0.3% 0-2000 / 51/2
 125V DC, ±20%, 12VA (OPTION D2)  Current 0.2VA MAX VAh & VARh  Digit Counter 
INPUT CURRENT RANGE DISPLAY UPDATE TIME
 10A maximum (programmable to any CT ratio) PF  0.50 % 1.0 TO ±0.5
 1 Second
HARMONIC RANGE WAVEFORM RECORDING Frequency 0.01 Hz 47-75 Hz
 3 Channels Volt to Neutral**  Dual Analog to Digital Processing
 3 Channels A, B and C Current** Harmonic 0.50% 0-100%
 One Second Update
**To the 31st Harmonic  Waveform Capable of Viewing 5 Times Full Scale
SENSING METHOD Current Neutral 2% 0-2000 
RMS for Current and 21/2 Times RMS for Voltage (Calculated) 
 True RMS
TIME CLOCK
INPUT WITHSTAND CAPABILITIES  On-Board Time/Date Clock – Non Volatile
 Voltage & Current Continuous 200% Rated; Surge 10x
SHIPPING  Reads in Kilovolts over 2000
Rated per 3 Seconds  Reads in MW, MVA, MVR for readings over 2,000
 6 lbs.
 Surge Withstand: per IEEE C37.90.1 *Accuracy in % of full scale

Note: Complete Mounting and Wiring Diagrams can be downloaded directly from www.electroind.com

Ordering Information
Specify a unit by writing its option numbers below. See sample. Specify your CT and Pt ratio, Delta or Wye System. If a specification is given, it will be preprogrammed in the factory.

Model Connection Volts Amps Power Operating Control Com Memory I/O Analog
Voltage Power Port Output
Option
Numbers:
- - - - - - - - - -

Example:
- 3E - V - A - KW - 120 - 115A - SF485DB - M200 - L200 - 1mAO
CPU 1000

CPU 1000 3E V A KW 120 115A X X X X


3 Element Volts Amps Kilowatt 120/208 Volts ±20% 12VA None None None None
Wye System Labeling Labeling Labeling Used Direct or with PTs

2.5E KV KA MW G 230A SF232DB M100 L200 1mA0


277/480 ±20% 12VA
2 .5 Element Kilovolts Kiloamps Megawatt
Direct Hookup
Wye System Labeling Labeling Labeling

2E 75 D SF485DB M150 L200KYZ 20mA0


2 Element 69 Volt Line to Neutral 24-48V DC
120 Volt Line to Line ±20% 12VA
Delta System

D2 M200
125V DC
±20% 12VA

Hardware Options
M100 M150 M200 L200 L200KYZ
512k Mass Memory 512k Mass Memory 1024k Mass Memory I/O Module I/O Module
Historical Data Logging Historical Data Logging for Historical Data Logging and 3 Relay Outputs and 3 KYZ Pulses and
and 25 Captured Event Waveforms 100 Captured Event Waveforms 4 Status Inputs 4 Status Inputs

1mAO 20mAO SF232DB SF485DB


Analog Output Module Analog Output Module RS232 Communication Adapter RS485 Multi-Drop, Daisy
10 Channels of 0-1mA 10 Channels of 4-20mA Chain Communication Adapter
Retransmitting Signals Retransmitting Signals 4000 Foot Range

Display Options Up to 4 displays with a CPU 1000 power supply. All displays include 6 feet of cable. If additional Length is desired, please specify. Look up display descriptions on previous pages.

P1 P14/15 P31 P32 P33 P34 ISO485


Single Function Energy Amps Volts Power Multifunction Isolation Module (for long
distance display applications)
Electro Industries/GaugeTech
1800 Shames Drive • Westbury, NY 11590
1- 877- EIMETER (1- 877- 346- 3837) • E-Mail: sales@electroind.com
Tel: 516-334 -0870 • Web Site: www.electroind.com • Fax: 516-338-4741 E100707 110107 B