Professional Documents
Culture Documents
Futura Brochure
Futura Brochure
Power Monitoring
& Analysis
True RMS Voltage,
Current, Power &
Energy
Harmonic Analysis
On-Board Event
Recording
On-Board Waveform
Recording
Description
Power Quality with Voltage The Futura+ Series, CPU Comprehensive • kVAR Max/Min
Stability & Reliability 1000, is an advanced, easy- Measurements • kVA Max/Min
Recording
to-use multi-function electri- • Three Phase Voltage (L -N)
• PF Max/Min
Current Fault Recording cal power monitor/transducer
• Three Phase Voltage (L - L)
that measures every aspect • Frequency Max/Min
of power including Voltage, • Three Phase Amps
• %THD Max
Current, Watts, VARs, VA, PF, • Neutral Current (Calculated)
Advanced Communication Freq. and Energy.
Capabilities From basic energy meter-
• Bidirectional kW
(Three Phase & Total) User Alarm Set Points
Dual Digital Com Ports ing to advanced power quality • Over/Under Voltage
analysis, the CPU 1000 arms • Bidirectional kVAR
Modbus & DNP 3.0 (Three Phase & Total) • Over/Under Current
you with sophisticated moni-
10 Channel Analog toring capabilities. The unit’s • Bidirectional kVA • Over/Under kVA
Retransmits (0-1 or comprehensive on-board (Three Phase & Total)
4-20mA) • Over/Under kW
memory provides immediate • PF (Three Phase & Total)
Up to 4 Remote access to historical, I/O and • Over/Under kVAR
Displays • Frequency
waveform recording. With the • Over/Under PF
M200 memory option, the unit • Bidirectional kWh
records up to 3 months of his- • Over/Under Frequency
• Bidirectional kVARh
torical data and 100 waveform • Over %THD
Utility Grade Design records. This makes the CPU • Bidirectional kVAh
Optically Isolated • Phase Reversal
1000 one of the most prolific • %THD
Sensing Voltages
analysis devices at its pricing • Reverse Power
• Harmonics to the 31st Order
Universal AC/DC Power point. • Logic & Hysteresis
Supply
The unit provides multiple
• Relay Output Control
Meets ANSI C62.41 (6 paths of communication pro- Advanced
kV Voltage Burst), IEEE viding open protocol solutions. Measurements
SWC C.37.90.1 (Surge Built-In analog retransmits retro-
Withstand) •Voltage Max/Min
fit into existing analog milliamp
Reliable in Harsh input based data collection. • Amps Demand Max/Min
Conditions
• KW Max/Min
Perfect for
Substation Panels
Electro Industries/GaugeTech
The Leader in Web Accessed Power Monitoring C
Power Quality/Harmonic Storage Capabilities
Analysis Recording*
Memory Historical I/O Event Stamping Waveform
The CPU 1000 conducts an Modules Recording**
110,000
extensive harmonic and power
quality analysis. The unit mea- M100 110,000 90 Days 255 for Relay and N/A
Snapshots
sures and calculates harmonic Input Status
Contacts
distortion to the 31st order
for each voltage and current M150 55,000 45 Days 255 for Relay and 25 Waveform
snapshots Input Status Records
channel. Using the M150 and Contacts
M200 memory modules, the
unit will record voltage distur- M200 110,000 90 Days 255 for Relay and 100 Waveform
snapshots Input Status Records
bances such as surges, sags Contacts
and transients.
Display Modules
50.5
50.5 +
I o o 9 8 39
50. i
50.6
Communication Ports
All communication ports are
isolated from the main unit and
additionally isolated from each
other. This design avoids dan-
gerous ground loops.
i 20.0 +
i7.24 i2 0.0
i 20.0
+
5.64 50.5
i 20.0 +
I 8.I 4 60.00
Note: Complete Mounting and Wiring Diagrams can be downloaded directly from www.electroind.com
Ordering Information
Specify a unit by writing its option numbers below. See sample. Specify your CT and Pt ratio, Delta or Wye System. If a specification is given, it will be preprogrammed in the factory.
Model Connection Volts Amps Power Operating Control Com Memory I/O Analog
Voltage Power Port Output
Option
Numbers:
- - - - - - - - - -
Example:
- 3E - V - A - KW - 120 - 115A - SF485DB - M200 - L200 - 1mAO
CPU 1000
D2 M200
125V DC
±20% 12VA
Hardware Options
M100 M150 M200 L200 L200KYZ
512k Mass Memory 512k Mass Memory 1024k Mass Memory I/O Module I/O Module
Historical Data Logging Historical Data Logging for Historical Data Logging and 3 Relay Outputs and 3 KYZ Pulses and
and 25 Captured Event Waveforms 100 Captured Event Waveforms 4 Status Inputs 4 Status Inputs
Display Options Up to 4 displays with a CPU 1000 power supply. All displays include 6 feet of cable. If additional Length is desired, please specify. Look up display descriptions on previous pages.