Professional Documents
Culture Documents
Filter Element 1
Filter Element 1
FRAMO
FILTER ELEMENT
REPLACEMENT INSTRUCTION
FORCLOSEDLOOPSYSTEM
FOR CLOSED LOOP SYSTEM
No.
Rev.A:
Rev. A:
1400-0152-4
Date/sign.: 07Sep94 I VT
Page: 11 of 11
18Jan01 /I BF
Venting-valve I O-ring I
Drain valve
1
1 Stop all power packs. Keep the feed pump running. (The oil by-passes filter unit).
3 Open drain valve and venting plug. The oil in the filter chamber drains to tank.
5 Install the new filter elements and end cover. (Ensure o-ring is not damaged).
6 Close the drain valve and the venting plug. Open venting valve.
7 Open the main return line valve 2. Mix. of oil and air will be drained to waste tank through the
venting valve.
8 When filter house and return pipes are completely filled with oil, close the venting valve.