Professional Documents
Culture Documents
Boq Glycerin Plant KRN - For Tender (Osbl Electrical) - 2021-06-04
Boq Glycerin Plant KRN - For Tender (Osbl Electrical) - 2021-06-04
Boq Glycerin Plant KRN - For Tender (Osbl Electrical) - 2021-06-04
PROJECT : DESIGN OF REFINED GLYCERINE PLANT 250 TPD AND RG STORAGE TANK FARM
SCOPE OF WORKS : ELECTRICAL & INSTRUMENT WORKS
LOCATION : BALIK PAPAN - KALIMANTAN TIMUR
OWNER : PT. KUTAI REFINERY NUSANTARA
CONSULTANT : PT. LYDUMA INTERMAS CONSULTANT
YEAR : 2021
REKAPITULASI
No. ITEM PEKERJAAN JUMLAH (Rp.)
I. PRELIMINARIES -
VAT 10 % Rp. -
ROUNDED TO BE Rp. -
_____________________ _____________________
Director Estimator
Internal
PROJECT : DESIGN OF REFINED GLYCERINE PLANT 250 TPD AND RG STORAGE TANK FARM
SCOPE OF WORKS : PRELIMINARIES
LOCATION : BALIK PAPAN - KALIMANTAN TIMUR
OWNER : PT. KUTAI REFINERY NUSANTARA
CONSULTANT : PT. LYDUMA INTERMAS CONSULTANT
YEAR : 2021
I. PRELIMINARIES
SUB TOTAL -
Internal
PROJECT : DESIGN OF REFINED GLYCERINE PLANT 250 TPD AND RG STORAGE TANK FARM
SCOPE OF WORK : ELECTRICAL WORKS
LOCATION : BALIK PAPAN - KALIMANTAN TIMUR
OWNER : PT. KUTAI REFINERY NUSANTARA
CONSULTANT : PT. LYDUMA INTERMAS CONSULTANT
YEAR : 2021
REVISE : 0
BILL OF QUANTITY
II. ELECTRICAL -
A. MEDIUM VOLTAGE -
A.1 CABLE
Pulling, termination & installation of NA2XSY 12/20(24) KV 1Cx120 mm2 MV Feeder Cable Switchgear
- Meter 1140 by Owner - -
Panel to Transformer RG Plant
Pulling, termination & installation by Cable Control Screen LiYCY 10Cx1.5 mm2 c/w accessories scoon, tag
- Meter 380 by Owner - -
number & nameplate
HIPOT/HV test cable AC/VLF end to end RST 3(1Cx120mm2), should be included in the package Hipot test,
- transportation, accommodation, reporting, etc. As spesification IEEE 400.2-2001, IEEE 400.2-2004, IEC, Lot 1 - - -
PUIL, SPLN, resistance test, isolation test, earthing test and technical test
- Supply & install sealant/sealing kit for sealing cable entries/cable duct available with foaming sealant. Lot 1 - - -
- Supply & install cable ties, black colour, size 500 (standart cable 500 mmsq) Lot 1 - - -
- Supply and installation termination accessories, tag number or nameplate Lot 1 - - -
- Installation & termination works of transformer 2500kVA 20/0.4 kV c/w install all accessories & compartment Lot 1 by Owner - -
Mobilization transformer with crane & truck (from storage to the site) for unloading and site position at
- Lot 1 by Owner - -
transfomer room, Unloading, Lifting, Fixing and Placing, transformer. Total Weigh of transformer 6955kg
Testing & precommissioning transformer with All tools tester, resistance test, isolation test, earthing test and
- Lot 1 - - -
technical test. Synergy & supporting to transformer's vendor.
Termination accessories: Alcohol for cleaning, Washcloth/Cloth laps, Nameplate panel, Cable marker/tag
- Lot 1 - - -
number.
Supply & fabricate framming support transformer with UNP 100 x 45 x 6 x 6000 mm for cupport c/w bolt & nut
- Lot 1 by Owner - -
and all accessories.
Installation works Panel LV electrical switchboard and accessories with follow stadard drawing and all panel
Used framming support for standing panel and mounting bracket support for mounting type panel, the
- Lot 2 by Owner
contractor is responsible for the condition of the panels during the erection, installation and termination period.
Levelling check for the framming support and connecting or jointing busbar with torque wrench.
- Supply, Installation, Unloading, Lifting , Setting , and Termination of LVMDP & Cap Bank Lot 1 by Owner - -
- Supply, Installation, Unloading, Lifting , Setting , and Termination of MCC BOP Lot 1 by Owner - -
- Pulling & Termination/Installation of NYY 4x1Cx120 mm2 LV Feeder Cable from LVMDP Panel to Nitrogen Meter 92 by Owner - -
- Pulling & Termination/Installation of NYY 4x95 mm2 LV Feeder Cable from LVMDP Panel to Compressor Meter 100 by Owner - -
- Pulling & Termination/Installation of NYY 2x4Cx6 mm2 LV Feeder Cable from LVMDP Panel to Carbonator Meter 484 by Owner - -
Pulling & Termination/Installation of NYY 4Cx25 mm2 LV Feeder Cable from LVMDP Panel to Indoor SDP
- Meter 50 by Owner - -
Lighting
Pulling & Termination/Installation of NYY 4Cx25 mm2 LV Feeder Cable from LVMDP Panel to Oudoor Lighting
- Meter 70 by Owner - -
01 (DP-01)
Pulling & Termination/Installation of NYY 4Cx25 mm2 LV Feeder Cable from LVMDP Panel to Oudoor Lighting
- Meter 120 by Owner - -
02 (DP-02)
Supply and Installation of RTU RS 485 Modbus cable 4(2x0.85) mm2 from MDP DPM incoming to OCC
- Meter 120 by Owner - -
Control room
- Supply & Installation of Scoon cable / cable lugs Copper 500 mmsq c/w Bolt & Nut & accessories Pcs 48 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 300 mmsq c/w Bolt & Nut & accessories Pcs 2 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 120 mmsq c/w Bolt & Nut & accessories Pcs 8 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 95 mmsq c/w Bolt & Nut & accessories Pcs 8 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 25 mmsq c/w Bolt & Nut & accessories Pcs 28 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 6 mmsq c/w Bolt & Nut & accessories Pcs 16 - - -
- Supply & Installation of PVC/Vinyl Wire end caps, colour red, blue, black & yellow. Lot 1 - - -
Pulling & Termination/Installation of LV Power cable SS with NYY 2x4Cx120 mm2 from MCC BOP to
- Meter 346 by Owner - -
Glycerine Export Pump 10-G-204B
Pulling & Termination/Installation of LV Power cable SD with NYY 2x4Cx4mm2 from MCC BOP to Yelow
- Meter 254 by Owner - -
Glycerine Export Pump 10-G-202
Pulling & Termination/Installation of LV Power Cable SS with NYY 4Cx25mm2 from MCC BOP to Glycerine
- Meter 118 by Owner - -
Transfer Pump 10-G-203A
Pulling & Termination/Installation of LV Power Cable SS with NYY 4Cx25mm2 from MCC BOP to Glycerine
- Meter 120 by Owner - -
Transfer Pump 10-G-203B
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx16mm2 from MCC BOP to Demin
- Meter 230 by Owner - -
Water Pump 10-G-206
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx6mm2 from MCC BOP to Dilution
- Meter 196 by Owner - -
Pump 10-G-208
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx4mm2 from MCC BOP to Hot Water
- Meter 166 by Owner - -
Pump 10-G-207
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx4mm2 from MCC BOP to Oil Trap
- Meter 196 by Owner - -
Pump 10-G-210
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx4mm2 from MCC BOP to
- Meter 160 by Owner - -
Condensate Transfer Pump 10-G-209
Pulling & Termination/Installation of LV Power Cable SD with NYY 2x4Cx6mm2 from MCC BOP to Waste
- Meter 483 by Owner - -
Residu RG Main Plant (Carbonator) Pump
Internal
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T201
- Meter 326 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T202
- Meter 356 by Owner - -
Mixer Agitator 01
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T202
- Meter 364 by Owner - -
Mixer Agitator 02
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T198
- Meter 256 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T199
- Meter 276 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T196
- Meter 332 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T197
- Meter 354 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T203
- Meter 312 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T204
- Meter 294 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of LV Power cable SD with NYY 4Cx2.5mm2 from MCC BOP to 10T205
- Meter 278 by Owner - -
Mixer Agitator
- Supply & Installation of Scoon cable / cable lugs Copper 120 mmsq c/w Bolt & Nut & accessories Pcs 32 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 25 mmsq c/w Bolt & Nut & accessories Pcs 16 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 16 mmsq c/w Bolt & Nut & accessories Pcs 16 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 6 mmsq c/w Bolt & Nut & accessories Pcs 24 - - -
- Supply & Installation of Scoon cable / cable lugs Copper 4 mmsq c/w Bolt & Nut & accessories Pcs 64 - - -
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC to Glycerine Export
- Meter 173 by Owner - -
Pump 10-G-204B
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Yelow
- Meter 127 by Owner - -
Glycerine Export Pump 10-G-202
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Glycerine
- Meter 118 by Owner - -
Transfer Pump 10-G-203A
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Glycerine
- Meter 120 by Owner - -
Transfer Pump 10-G-203B
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Demin
- Meter 115 by Owner - -
Water Pump 10-G-206
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Dilution
- Meter 98 by Owner - -
Pump 10-G-206
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Hot Water
- Meter 83 by Owner - -
Pump 10-G-207
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Oil Trap
- Meter 98 by Owner - -
Pump 10-G-210
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to
- Meter 80 by Owner - -
Condensate Transfer Pump 10-G-209
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to Waste
- Meter 241 by Owner - -
Residu RG Main Plant (Carbonator) Pump
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T200
- Meter 148 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T201
- Meter 163 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T202
- Meter 178 by Owner - -
Mixer Agitator 01
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T202
- Meter 182 by Owner - -
Mixer Agitator 02
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T198
- Meter 128 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T199
- Meter 138 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T196
- Meter 166 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T197
- Meter 177 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T203
- Meter 156 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T204
- Meter 147 by Owner - -
Mixer Agitator
Pulling & Termination/Installation of Local switch Cable with NYYHY 3x1,5mm2 from MCC BOP to 10T205
- Meter 139 by Owner - -
Mixer Agitator
Supply & Installation of support Switch (Remote) with UNP 100x50x6 H=1.2m c/w Base plate h=8mm Thk &
- set 22 by Owner - -
accessoriest required
Installation of Fitting Steel Conduit pipe IMC Type, (elbow, Coupling, clamp, bolt, nut, etc), Size 3/4",
- Lot 1 by Owner - -
panasonic make
- Supply & Installation of Straight Steel Conduit pipe IMC Type, Size 3/4" for power cable, panasonic make Meter 72 by Owner - -
Supply & Installation of Fitting Steel Conduit pipe IMC Type, (elbow, Coupling, clamp, bolt, nut, etc), Size 3/4",
- Lot 1 by Owner - -
panasonic make
- Install/fabricating angel bar L50x50x5 paint finishing Lot 1 by Owner - -
Supply/Install Cable Level switch NYYHY 3x1,5mm2 from Level Switch to Sensor switch Oil Trap Pump 10-G-
- Meter 98 by Owner - -
210
Supply/Install Cable Level switch NYYHY 3x1,5mm2 from Level Switch to Sensor switch Condensate Transfer
- Meter 80 by Owner - -
Pump 10-G-209
D.3 SUPPORT
- Install/fabricating angel bar L60x60x5 paint finishing Lot 1 by Owner - -
E LIGHTNING PROTECTION -
E.1 AREMATURE AND INSTALLATION
- Installation Lightning Arester Radius type set 1 by Owner - -
- Supply & Installation Ex Obstruction lamp set 1 by Owner - -
- Supply & Installation of Pole lightning arrester H : 8 Meter From roof as per drawing set 1 by Owner - -
- Guy wire ss ( GUYKIT-7M-SS) c/w accessoriest m 30 - - -
- Upper Termination Kit set 1 - - -
- FRP Support Mast - 2m set 1 - - -
- Inline Coupling set 1 - - -
Internal
E.2 GROUNDING
- Grounding Pit Chamber & Control Box 20 x 20 x 30 cm with concrete or other material set 1 - - -
- Grounding busbar 18x3x0.5 cm pcs 1 by Owner - -
- Porselin isolator pcs 3 by Owner - -
- Round Rod Copper 5/8", 4 Meter length 3 by Owner - -
- Tiger Claw Clamp, cooper material pcs 3 - - -
- Clamp Rod pcs 3 by Owner - -
- Bolt, Nut, Washer ( 2WP, 1SW ) lot 1 - - -
- Main conductor with Cable Bar copper 70mmq Meter 50 by Owner - -
- Scoon cable (cable lugs) Copper 70 mmsq c/w Bolt & Nut (Carbon steel) Pcs 4 - - -
- Jasa penancapan grounding rod nos 3 - - -
- Connection with the Cad weld method lot 1 - - -
- Accessories Required for grounding installation lot 1 - - -
F. LIGHTING -
F.1 ZONA A
1 DP-01
- Supply and install powder coat Panel Box (WATERPROOF) Outdoor Type set 1 - - -
- MCCB A1N-Icu 380/415V 25A 36kA Ea 1 include
- MCB S 201 L C10. 10A. 10 KA 1P Ea 5 include
- MCB S 201 L C6. 6A. 6 KA 1P Ea 4 include
- RCCB 2P 25A 30mA Ea 3 include
- Selector Switch TSS-251 25mm ( Auto-Man ) Ea 1 include
- TIMER AT2e-R 220V Ea 1 include
- Contactors AX 25-30-10 3P 220VAC Ea 1 include
- Pilot Lamp XB7-EVL LED 22MM 220V [G] Ea 1 include
- Pilot Lamp XB7-EVL LED 22MM 220V [Y] Ea 1 include
- Pilot Lamp XB7-EVL LED 22MM 220V [R] Ea 1 include
- Branching busbar by full isolation, busbar terminal cable, cable installation and all accessoriest Lot 1 include
- All Accessories termination c/w internal wiring, nameplate, sealing kit, pertinax, cable gland and tag number Lot 1 include
2 LIGHTING ARMATURE
- Supply and Fixing of STREET LIGHT TPYE GLD350S 120 W, 5700K set 14 by Owner - -
- Supply and Fixing of Lighting Pole type A c/w Electrical box and All Accessories set 4 - - -
- Supply and Fixing of Lighting Pole type B c/w Electrical box and All Accessories set 7 - - -
- Supply and Fixing of Lighting Pole type C c/w Foundation, Electrical box and All Accessories set 3 - - -
- Accessories Required lot 1 - - -
- - -
3 LIGHTING INSTALLATION
- Supply & Installation Lighting Point with Cable NYY 3x2,5 mm Meter 400 by Owner - -
- Supply & Installation Lighting Point with Cable NYFGBY 3x2,5 mm Meter 109 by Owner - -
- Supply & Installation of Straight conduit pipe HDG IMC type, Size 3/4" Meter 182 by Owner - -
- Supply & Installation of elbow, Jointing, Tdos, Clamp and Accessories conduit pipe HDG IMC type, Size 3/4" Lot 1 by Owner - -
F.2 ZONA B
1 DP-02
- Supply and install powder coat Panel Box (WATERPROOF) Outdoor Type set 1 - - -
- MCCB A1N-Icu 380/415V 25A 36kA Ea 1 include -
- MCB S 201 L C10. 10A. 10 KA 1P Ea 5 include -
- MCB S 201 L C6. 6A. 6 KA 1P Ea 4 include -
- RCCB 2P 25A 30mA Ea 3 include -
- Selector Switch TSS-251 25mm ( Auto-Man ) Ea 1 include -
- TIMER AT2e-R 220V Ea 1 include -
- Contactors AX 25-30-10 3P 220VAC Ea 1 include -
- Pilot Lamp XB7-EVL LED 22MM 220V [G] Ea 1 include -
- Pilot Lamp XB7-EVL LED 22MM 220V [Y] Ea 1 include -
- Pilot Lamp XB7-EVL LED 22MM 220V [R] Ea 1 include -
- Branching busbar by full isolation, busbar terminal cable, cable installation and all accessoriest Lot 1 include -
- All Accessories termination c/w internal wiring, nameplate, sealing kit, pertinax, cable gland and tag number Lot 1 include -
2 LIGHTING ARMATURE
- Supply and Fixing of STREET LIGHT TPYE GLD350S 120 W, 5700K set 26 by Owner - -
- Supply and Fixing of STAIRCASE LIGHTING 30W with TYPE GLD8560 SERIES LED Low -Mid Bay, 5700K set 7 by Owner - -
- Supply and Fixing of Lighting Pole type Roof tank (show on drawing) c/w All Accessories set 15 by Owner - -
- Supply and Fixing of Lighting Pole for staircase (show on drawing) c/w Electrical box and All Accessories set 7 by Owner - -
- Supply and Fixing of Lighting Pole type B c/w Electrical box and All Accessories set 10 by Owner - -
- Supply and Fixing of Lighting Pole type C c/w Electrical box and All Accessories set 1 by Owner - -
- Flexible conduit, size 3/4" lot 1 by Owner - -
- Accessories Required lot 1 - - -
3 LIGHTING INSTALLATION
- Supply & Installation with Cable NYY 3x2,5 mm Meter 835 by Owner - -
- Supply & Installation of Straight conduit pipe HDG IMC type, Size 3/4" Meter 542 by Owner - -
- Supply & Installation of elbow, Jointing, Tdos, Clamp and Accessories conduit pipe HDG IMC type, Size 3/4" Lot 1 by Owner - -
G. GROUNDING -
G.1 TRAFO
- Grounding Pit Chamber & Control Box 20 x 20 x 30 cm with concrete or other material set 1 - - -
- Grounding busbar 18x3x0.5 cm pcs 1 by Owner - -
- Porselin isolator pcs 2 by Owner - -
- Round Rod Copper 5/8", 4 Meter length 2 by Owner - -
- Tiger Claw Clamp, cooper material pcs 2 - - -
- Clamp Rod pcs 2 by Owner - -
- Bolt, Nut, Washer ( 2WP, 1SW ) lot 1 - - -
- Cable BC 70mmq from box control to grounding pole Meter 12 by Owner - -
- Cable NYA 70mmq From Trafo to box control Meter 25 by Owner - -
- Scoon cable (cable lugs) Copper 70 mmsq c/w Bolt & Nut (Carbon steel) Pcs 2 - - -
Internal
Testing (All tools tester, resistance test, isolation test, earthing test and technical test , continuity Test,) power
- lot 1 - - -
cable, tag number, nameplate, SDP & DP Panel & Auxilliary panel.
Internal
PROJECT : DESIGN OF REFINED GLYCERINE PLANT 250 TPD AND RG STORAGE TANK FARM
SCOPE OF WORK : INSTRUMENT WORKS
LOCATION : BALIK PAPAN - KALIMANTAN TIMUR
OWNER : PT. KUTAI REFINERY NUSANTARA
CONSULTANT : PT. LYDUMA INTERMAS CONSULTANT
YEAR : 2021
REVISE : 0
BILL OF QUANTITY
14 DISCRETTE TRANSMITTER
a. Fixing and Installation Discrette Transmitter c/w smart power option 4 Pcs by Owner - -
b. Supply and Installation Instrument Support Discrette Transmitter 4 set by Owner - -
16 INSTRUMENT CABLE
a. INSTRUMENT
Pulling POWER
& Installation CABLE
of Feeder Cable N2XY 3x2.5mm² for MCC BOP to INSTRUMENT ELECTRICAL DISTRIBUTION PANEL
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank CG TANK 500 MT 10T196 107 Meter by Owner - -
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank Y. GLYCERINE TANK 250 MT 10T204 94 Meter by Owner - -
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank REFINED GLYCERINE DAY TANK 500 MT 10T198 66 Meter by Owner - -
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank REFINED GLYCERINE TANK 3000 MT 10T200 72 Meter by Owner - -
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank REFINED GLYCERINE TANK 4000 MT 10T202 49 Meter by Owner - -
- Pulling & Installation of Cable N2XY 3x1.5mm² for HUB power cable the tank DILUTION TANK 300 MT 10T206 115 Meter by Owner - -
- 58 Meter by Owner - -
c. INSTRUMENT
Pulling CABLE
& Installation FOR CONTROL
of Cable VALVE 1x2x1,5mm² mm2 for tank REFINED GLYCERINE DAY TANK 500 MT 10T198
CU/XLPE/IS-OS/PVC
- Pulling & Installation of Cable CU/XLPE/IS-OS/PVC 1x2x1,5mm² for tank REFINED GLYCERINE DAY TANK 500 MT 10T199 118 Meter by Owner - -
Pulling & Installation of Cable CU/XLPE/IS-OS/PVC 1x2x1,5mm² for tank REFINED GLYCERINE TANK 3000 MT 10T200
- 127 Meter by Owner - -
Pulling & Installation of Cable CU/XLPE/IS-OS/PVC 1x2x1,5mm² for tank REFINED GLYCERINE TANK 3000 MT 10T201
- 140 Meter by Owner - -
Pulling & Installation of Cable CU/XLPE/IS-OS/PVC 1x2x1,5mm² for tank REFINED GLYCERINE TANK 4000 MT 10T202
- 157 Meter by Owner - -
- 168 Meter by Owner - -
d. GROUNDING CABLE
Supply and Installation of Cable NYAF 6mm2 from Field instrument to grounding of Junction Box
- 353 Meter by Owner - -
Supply and Installation of Cable Gland 6mm2
- 20 pcs - - -
17 CONDUIT PIPE
a. Instrument Power Cable
- Installation of Straight Steel Conduit pipe IMC Type, Size 3/4" for power cable 181 Meter by Owner - -
- Installation of Fitting Conduit pipe IMC Type, (elbow,TEE DOS 3 Way, Coupling, clamp, bolt, nut, etc), Size 3/4" 1 Lot by Owner - -
- Installation of L50x50x5 1 Lot by Owner - -
b. Instrument Cable the wireless
- Installation of Straight Steel Conduit pipe IMC Type, Size 3/4" for power cable 150 Meter by Owner - -
- Installation of Fitting Conduit pipe IMC Type, (elbow,TEE DOS 3 Way, Coupling, clamp, bolt, nut, etc), Size 3/4" 1 Lot by Owner - -
- Installation of L50x50x5 1 Lot by Owner - -
c. Field Instrument Cable
- Installation of Straight Steel Conduit pipe IMC Type, Size 3/4" for power cable 276 Meter by Owner - -
- Installation of Fitting Conduit pipe IMC Type, (elbow,TEE DOS 3 Way, Coupling, clamp, bolt, nut, etc), Size 3/4" 1 Lot by Owner - -
- Installation of L50x50x5 1 Lot by Owner - -
d. Control Valve Cable
- Installation of Straight Steel Conduit pipe IMC Type, Size 3/4" for power cable 150 Meter by Owner - -
- Installation of Fitting Conduit pipe IMC Type, (elbow,TEE DOS 3 Way, Coupling, clamp, bolt, nut, etc), Size 3/4" 1 Lot by Owner - -
- Installation of L50x50x5 1 Lot by Owner - -
18 PNEUMATIC SYSTEM
- Supply and Install Stainless Steel pipe 304 Sch10 dia 1/2" 42 Meter by Owner - -
- Supply and Install Stainless Steel Fitting 304 Sch10 dia 1/2" 1 Lot by Owner - -
- Supply and Install Stainless Steel Ball Valve dia 1/2" 5 Ea by Owner - -
- Supply and Install air fiter regulator lubricator c/w accessories required 5 set by Owner - -
- Supply and Install Stainless Steel Swagelok Straight Male Connector 1/4in tube 1/2in Male NPT 10 Ea by Owner - -
- Supply and Install Stainless Steel Swagelok Straight Male Connector 1/4in tube 1/4in Male NPT 10 Ea by Owner - -
- Supply and Install Stainless Steel Swagelok Tube Fitting, Union Elbow, 1/4 in. Tube OD 1 lot by Owner - -
- Supply and Install Stainless Steel Swagelok Tube 1/4 in. Tube OD 108 Meter by Owner - -