Download as pdf or txt
Download as pdf or txt
You are on page 1of 56

DARK SKY REPORT LANDSCAPE LIGHTING

R01-H14D03-STN-RPT-EL-0003 Rev.01 Issued For Construction


16 JULY 2021
DARK SKY LANDSCAPE LIGHTING REPORT
Content

1. Calculation Parameters

2. Overall Key Plan

3. Dark Sky Calculations

4. Dark Sky Submission Checklist

5. Dark Sky Report Checklist


Calculation Parameters

Depreciation Factor 1.0 FF&E Specifications

Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm

Ref: X-DF3
Lantern
10 W
650 lm
Upwards Spill Light 2700K
Calculation plane H:
@10m from the highest luminaire
Ref: X-DF5
Lantern
10 W
450 lm
10m 2700K

Outwards Spill Light


Calculation plane @5m Polar curve of all FF&E luminaires have
away from the luminaire downward beam distribution.
ELEVATION OF THE BUILDING/Object
SUBJECT TO CALCULATION

5m

Calculation plane
Overall Key Plan

6
8
11 5
7 4 14
2
9 3
10
1
13
12

1 Entrance 8 Street with bollards

2 Water Feature 9 Rock

3 Water Wall 10 Typical crossroads

4 Pathway under petals 11 Outdoor lobby

5 Weathered stairs 12 Pathway near cabana

6 Hotel Stairs 13 Pool

7 Villa Stairs 14 BOH - Road


Entrance
Lighting levels Overview
Updated Calculation Date: 10/06/21

1
Key Plan

Upwards Spill Light

Ref: X-DF5
Fixtures’ location

Plan

Note:
E av. 0.073 lux Upwards Spill Light
E max 0.18 lux • Luminaires are dimmed @75%

E av. 1.28 lux on floor

Material Codes & Material Reference Estimated


Description Image Reflectance
Floor Sand 0.4
Section

Calculation plane
Entrance
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-DF5
Lantern
10 W
450 lm
2500K
Entrance
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.073 lx 0.027 lx 0.18 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 1.28 lx 0.004 lx 6.28 lx


Water Feature
Lighting levels Overview
Updated Calculation Date: 10/06/21

Key Plan 2

Upwards Spill Light

Ref: X-U1 (20 items)


Fixtures’ location

Note:

Plan • only 20 items of X-U1 are installed.


E av. 0.007 lux Upwards Spill Light
E max 0.01 lux

E av. 0.04 lux on the floor

Material Codes & Material Reference Estimated


Description Image Reflectance
Floor Sand 0.4
Section
Ref: X-U1 (20 items)
Calculation plane
Fixtures’ location
Water Feature
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-U1
Inground Recessed Light
0.8 W
58 lm
88 deg
2700K

20 nos. X-U1 type


luminaires

Section
Water Feature
Lighting Levels Overview
Updated Calculation Date:10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.007 lx 0.004 lx 0.01 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 0.04 lx 0.005 lx 0.21 lx


Water wall
Lighting levels Overview
Updated Calculation Date: 10/06/21

This area is covered by the petals

Key Plan 3
Upwards Spill Light

c
c
c
Ref: X-DF1
Fixtures’ location

Ref: X-L3
Plan Fixtures’ location
Note:
E av. 0.075 lux Upwards Spill Light
• Linear light is dimmed @ 30%
E max 0.27 lux

• This area is covered by the petals.

Petal • The Upwards spill Light calculation


plane is located @ H: 17.5m (1m above
the petal)

E av. 0.24 lux on the floor • Degree of transmission of the petal is


considered 40%.

Material Codes & Material Reference Estimated


Description Image Reflectance
Floor Sand 0.4
Section
Ref: X-L3
Fixtures’ location Water Info not available Not available 0.65
Calculation plane
wall
Water wall
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

This area is covered by the petals


Ref: X-L3 Ref: X-DF1
Encapsulated linear Bollard
LED front emission 5W
10 W/m 34 lm
530 lm/m 2700K
2700K H: 500mm

Section Detail
Water wall
Lighting Levels Overview
Updated Calculation Date: 10/06/21

This area is covered by the petals

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.075 lx 0.004 lx 0.27 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 0.24 lx 0.005 lx 2.69 lx


Pathway under petals
Lighting levels Overview
Updated Calculation Date: 10/06/21

This area is covered by the petals


4
Key Plan
Upwards Spill Light

Ref: X-DF1
Fixtures’ location

Ref: X-P2
Plan Fixtures’ location

Note:
E av. 0.034 lux Upwards Spill Light
E max 0.18 lux
• Luminaires are dimmed @75%

• The petals are included in the calculation.

Petal • The Upwards spill Light calculation plane


is located @ 1m above the petal

• Degree of transmission of the petal is


considered 40%.
E av. 1.06 lux on the floor

Material Codes & Material Reference Estimated


Description Image Reflectance
Floor Sand 0.4
Section

Calculation plane
Pathway under petals
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

This area is covered by the petals

Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm

Ref: X-P2
Adjsutable multihead accent light
Adjustable (pre-locked at 45 degree downwards)
4,5 W x 2
1092 lm
2700K
H: 900mm
Pathway under petals
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.034 lx 0.004 lx 0.18 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 1.06 lx 0.003 lx 7.75 lx


Stairs – Weathered
Lighting levels Overview
Updated Calculation Date: 10/06/21

Ref: X-W4 5
Fixtures’ location Key Plan

Upwards Spill Light

Plan

Note:
E av. 0.096 lux Upwards Spill Light
E max 0.29 lux • Luminaires are dimmed @ 20%

E av. 3.39 lux on Step

Material Codes & Material Reference Estimated


Description Image Reflectance
Steps Light Beige Stone Not available 0.5
Section

Calculation plane
Stairs – Weathered
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-W4
Low glare Wall recessed light
2W
88 lm
2700K

Mounting detail section


Stairs – Weathered
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.096 lx 0.011 lx 0.29 lx

Step
Properties E Emin Emax

Perpendicular illuminance 3.39 lx 0.29 lx 31.4 lx


Stairs – Hotel
Lighting levels Overview
Updated Calculation Date: 10/06/21

Ref: X-W3
6
Fixtures’ location Key Plan

Upwards Spill Light

Plan

E av. 0.20 lux Upwards Spill Light


E max 0.27 lux Note:

• Luminaires are dimmed @ 50%

E av. 19.8 lux on landing E av. 26.4 lux on Flight

Material Codes & Material Reference Estimated


Description Image Reflectance
Steps Light Beige Stone Not available 0.5

Calculation plane
Section
Stairs – Hotel
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-W3
Low glare Wall recessed light
2W
88 lm
2700K

Mounting detail section


Stairs – Hotel
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.2 lx 0.095 lx 0.27 lx

Flight
Properties E Emin Emax

Perpendicular illuminance 26.4 lx 2.28 lx 114 lx

Landing
Properties E Emin Emax

Perpendicular illuminance 19.8 lx 3.14 lx 100 lx


Stairs - Villa cluster
Lighting levels Overview
Updated Calculation Date: 10/06/21

Key Plan 7
Ref: X-B3
Fixtures’ location

Upwards Spill Light

Plan

Note:
E av. 0.091 lux Upwards Spill Light
E max 0.25 lux • Luminaires are dimmed @ 75%

E av. 19.3 lux on flight

E av. 1.05 lux on Landing

Material Codes & Material Reference Estimated


Description Image Reflectance
Steps Light Beige Stone Not available 0.5
Section

Calculation plane
Stairs - Villa cluster
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-B3
Low glare Wall recessed light
2W
88 lm
2700K

Mounting detail section


Stairs - Villa cluster
Lighting levels overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.091 lx 0.009 lx 0.25 lx

Flight
Properties E Emin Emax

Perpendicular illuminance 19.3 lx 0.46 lx 266 lx

Landing
Properties E Emin Emax

Perpendicular illuminance 1.05 lx 0.19 lx 5.60 lx


Street with bollards
Lighting levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light 8


Key Plan

Plan

Ref: X-B1
Fixtures’ location

Note:
E av. 0.055 lux Upwards Spill Light
E max 0.27 lux • Luminaires are dimmed @ 15%

E av. 0.6 lux on the floor Material Codes & Material Reference Estimated
Description Image Reflectance
Floor Sand 0.4
Section
Calculation plane Fixtures’ location
Street with bollards
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-B1
Bollard Lighting
7.4 W
491 lm
2700K

Mounting detail
Street with bollards
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.055 lx 0.009 lx 0.27 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 0.6 lx 0.001 lx 198 lx

Note:

• This calculation is revised as per the DD comments.

• The Emax 198 lux, is identified on one point right under the luminaire, and
it’s unlikely to cause any disturbance or glare thanks to the significantly small
area of the hot spot.
Rock
Lighting levels Overview
Updated Calculation Date: 10/06/21

9
Key Plan

Outwards Spill Light


Vertical illuminance

Ref: X-P3
Fixtures’ location

Upwards Spill Light

Plan

E av. 0.011 lux Upwards Spill Light


E max 0.033 lux

Outwards Spill Light Note:


Vertical illuminance
E av. 0.023 lux • Luminaires are dimmed @75%

Material Codes & Material Reference Estimated


Description Image Reflectance
Rock Light Beige Stone Not available 0.5
Section Ref: X-P3
Fixtures’ location
Calculation plane
Rock
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-P3
Spike mounted spotlight
3.5 W
164 lm
2700K

Mounting detail
Rock
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.011 lx 0.003 lx 0.033 lx

Outwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.023 lx 0.00 lx 0.58 lx


Typical Crossroads
Lighting levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light Key Plan 10

Plan

Ref: X-B1
Fixtures’ location

E av. 0.09 lux Upwards Spill Light


E max 0.28 lux

Note:

• Luminaires are dimmed @ 30%

E av. 0.69 lux on the floor


Material Codes & Material Reference Estimated
Description Image Reflectance
Floor Sand 0.4
Section

Calculation plane Ref: X-B1


Fixtures’ location
Typical Crossroads
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-B1
Bollard Lighting
7.4 W
491 lm
2700K

Mounting detail
Typical Crossroads
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.09 lx 0.019 lx 0.28 lx

Floor
Properties E Emin Emax
Note:
Perpendicular illuminance 0.69 lx 0.003 lx 312 lx
• This calculation is revised as per the DD comments.

• The Emax 312 lux, is identified on one point right under the luminaire, and
it’s unlikely to cause any disturbance or glare thanks to the significantly small
area of the hot spot.
Outdoor Lobby
Lighting levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Horizontal illuminance 11
E av. 0.24 lux
Key Plan

Outwards Spill Light


Vertical illuminance
E av. 0.048 lux

Petals

Plan

Note:

• Luminaires are dimmed @75%

Petals

E av. 0.056 lux


E max 0.056 lux
Upwards Spill Light

E av. 0.032 lux


Outwards Spill Light
Material Codes & Material Reference Estimated
Description Image Reflectance
Upper Grass 0.15
Floor
Section
Calculation plane Lower Light Beige stone Not available 0.5
Floor
Outdoor Lobby
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-P3
Spike mounted spotlight
3.5 W
164 lm
2700K
36 deg

Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm
Outdoor Lobby
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.018 lx 0.001 lx 0.056 lx

Outwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.032 lx 0.001 lx 0.19 lx


Pathway near Cabana
Lighting levels Overview
Updated Calculation Date: 10/06/21

Key Plan 12
Upwards Spill Light

Ref: X-DF3
Fixtures’ location

Plan

E av. 0.11 lux Upwards Spill Light


E max 0.29 lux
Note:

• Luminaires are dimmed @ 60%

E av. 0.34 lux on the floor Material Codes & Material Reference Estimated
Description Image Reflectance
Floor Sand 0.4
Section

Calculation plane
Pathway near Cabana
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-DF3
Lantern
10 W
650 lm
2700K
H: 650mm
Pathway near Cabana
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.11 lx 0.015 lx 0.29 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 0.34 lx 0.001 lx 8.51 lx


Pool
Lighting levels Overview
Updated Calculation Date: 10/06/21

Plan
Outwards spill light / Key Plan
vertical illuminance 13
Floor steps area E av. 0.11 lux
Horizontal illuminance 3
E av. 23.5 lux

Ref: X-UW3
Outwards spill light /
Fixtures’ location
2 vertical illuminance
E av. 0.15 lux

Floor middle area


Horizontal illuminance
E av. 21.8 lux

Outwards spill light /


Ref: X-UW2 vertical illuminance
Fixtures’ location E av. 0.14 lux

Ref: X-P8
Fixtures’ location
Note:

Upwards Spill Light • Luminaires mounted on


Horizontal illuminance
E av. 0.19 lux
palm trees @ H:6m
E av. 0.15 lux
E max 0.41 lux • Luminaires on palm trees are
Upwards spill light dimmed @ 75%
Calculation plane H= @16m Outwards spill light

1 E av. 0.14 lux


• Water material settings:
2 E av. 0.15 lux
Reflection factor: 20%
3 E av. 0.11 lux
Degree of transmission: 9%
Refractive index: 1.5
Section

Calculation plane
Pool
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-UW3
Recessed lighting
for steps
6W
450 lm
40deg
3000K

Ref: X-UW1
Recessed lighting
for steps and walls
39 W/m
2652 lm
Grazing 14°x40°
3000K
L: 360mm

Ref: X-P8
Spotlight mounted
on palm trees
5W
550 lm
45 deg
3000K

Water material settings:

Reflection factor: 20%


Degree of transmission: 9%
Refractive index: 1.5
Pool
Upwards Spill Light Overview
Updated Calculation Date: 10/06/21

Plan Section

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.15 lx 0.005 lx 0.41 lx


Pool
Outwards Spill Light Overview
Updated Calculation Date: 10/06/21

Plan Section

1- Outwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.14 lx 0.003 lx 0.74 lx

2- Outwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.15 lx 0.025 lx 0.60 lx

3- Outwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.11 lx 0 lx 0.59 lx


Pool
Floor Light Overview
Updated Calculation Date: 10/06/21

Section Calculation planes located at floor level

Plan

1- Horizontal plane – Floor – steps area


Properties E Emin Emax

Perpendicular illuminance 17.6 lx 1.47 lx 143 lx

Note:

2- Horizontal plane – Floor – Middle area • This calculation is revised as per the DD comments.
Properties E Emin Emax
• The Emax 1589 lux, is identified on one point right under the luminaire on the steps. And it’s
Perpendicular illuminance 15.2 lx 0.16 lx 1589 lx unlikely to be glary thanks to the significantly small area of the hotspot and the fact that this area is
used as a quick passage and not as a lounge.
BOH - Road
Lighting levels Overview
Updated Calculation Date: 10/06/21

Key Plan 14
Upwards Spill Light

Ref: X-W2
Fixtures’ location

Plan
Note:

• Luminaires are dimmed @ 15%


E av. 0.14 lux Upwards Spill Light
E max 0.3 lux

E av. 1.59 lux on the floor

Ref: X-W2
Material Codes & Material Reference Estimated
Fixtures’ location
Description Image Reflectance
Floor Sand 0.4

Section
Calculation plane
BOH - Road
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-W2
Wall Recessed Light
7.8 W
463 lm
2700K
Asymmetric / floor wash

Mounting detail
BOH - Road
Lighting Levels Overview
Updated Calculation Date: 10/06/21

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.14 lx 0.035 lx 0.30 lx

Floor
Properties E Emin Emax

Perpendicular illuminance 1.59 lx 0.005 lx 56.8 lx


Tree - Phoenix Atlantica (Most critical tree calculation)
Lighting levels Overview
Tree is covered by the petals
Updated Calculation Date: 10/06/21

Reference image
Calculation
E av. 0.025 lux Upwards Spill Light surface
E max 0.24 lux

Petals
10 m

Note:

4.5 m • Luminaires are dimmed @ 50%

• The petals are included in the


calculation.
Ref: X-P1
Fixture mounted @ 70 deg • Degree of transmission of petals is
from ground level considered 40%.

• Calculation surface is mounted 1m above


Section the petals.
0.8 m

Calculation plane
Tree - Phoenix Atlantica
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21

Ref: X-P1
Spike mounted spotlight
15 W
240 lm
Beam angle: 38
2700K

10 m

Upwards Spill Light


5m

Plan - Calculation plane

Upwards Spill Light


Properties E Emin Emax

Perpendicular illuminance 0.025 lx 0 lx 0.24 lx


Vertical Illuminance at the property line
Compliance with LEED and IDA/IES requirements
Updated Calculation Date: 10/06/21

Key Plan

Property line
Maximum vertical
580m
illuminance is 0 lux

200m

450m
Built Area
Compliance with LEED and IES:

• Maximum vertical illuminance at any


point in the plane of the property line
is 0 lux:

< 0.5 lux required by the


IDA / IES MODEL LIGHTING
ORDINANCE (MLO).
470m
< 0.5 Lux required by LEED
(light pollution reduction _Option 2[2])
Dark Sky Submission Checklist
Dark Sky Submission Checklist (Cont.)
Dark Sky Report Checklist
Dark Sky Report Checklist (cont.)

You might also like