1. Calculation Parameters
Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm
Ref: X-DF3
Lantern
10 W
650 lm
Upwards Spill Light 2700K
Calculation plane H:
@10m from the highest luminaire
Ref: X-DF5
Lantern
10 W
450 lm
10m 2700K
5m
Calculation plane
Overall Key Plan
6
8
11 5
7 4 14
2
9 3
10
1
13
12
1
Key Plan
Ref: X-DF5
Fixtures’ location
Plan
Note:
E av. 0.073 lux Upwards Spill Light
E max 0.18 lux • Luminaires are dimmed @75%
Calculation plane
Entrance
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-DF5
Lantern
10 W
450 lm
2500K
Entrance
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Key Plan 2
Note:
Ref: X-U1
Inground Recessed Light
0.8 W
58 lm
88 deg
2700K
Section
Water Feature
Lighting Levels Overview
Updated Calculation Date:10/06/21
Floor
Properties E Emin Emax
Key Plan 3
Upwards Spill Light
c
c
c
Ref: X-DF1
Fixtures’ location
Ref: X-L3
Plan Fixtures’ location
Note:
E av. 0.075 lux Upwards Spill Light
• Linear light is dimmed @ 30%
E max 0.27 lux
Section Detail
Water wall
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Ref: X-DF1
Fixtures’ location
Ref: X-P2
Plan Fixtures’ location
Note:
E av. 0.034 lux Upwards Spill Light
E max 0.18 lux
• Luminaires are dimmed @75%
Calculation plane
Pathway under petals
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm
Ref: X-P2
Adjsutable multihead accent light
Adjustable (pre-locked at 45 degree downwards)
4,5 W x 2
1092 lm
2700K
H: 900mm
Pathway under petals
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Ref: X-W4 5
Fixtures’ location Key Plan
Plan
Note:
E av. 0.096 lux Upwards Spill Light
E max 0.29 lux • Luminaires are dimmed @ 20%
Calculation plane
Stairs – Weathered
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-W4
Low glare Wall recessed light
2W
88 lm
2700K
Step
Properties E Emin Emax
Ref: X-W3
6
Fixtures’ location Key Plan
Plan
Calculation plane
Section
Stairs – Hotel
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-W3
Low glare Wall recessed light
2W
88 lm
2700K
Flight
Properties E Emin Emax
Landing
Properties E Emin Emax
Key Plan 7
Ref: X-B3
Fixtures’ location
Plan
Note:
E av. 0.091 lux Upwards Spill Light
E max 0.25 lux • Luminaires are dimmed @ 75%
Calculation plane
Stairs - Villa cluster
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-B3
Low glare Wall recessed light
2W
88 lm
2700K
Flight
Properties E Emin Emax
Landing
Properties E Emin Emax
Plan
Ref: X-B1
Fixtures’ location
Note:
E av. 0.055 lux Upwards Spill Light
E max 0.27 lux • Luminaires are dimmed @ 15%
E av. 0.6 lux on the floor Material Codes & Material Reference Estimated
Description Image Reflectance
Floor Sand 0.4
Section
Calculation plane Fixtures’ location
Street with bollards
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-B1
Bollard Lighting
7.4 W
491 lm
2700K
Mounting detail
Street with bollards
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Note:
• The Emax 198 lux, is identified on one point right under the luminaire, and
it’s unlikely to cause any disturbance or glare thanks to the significantly small
area of the hot spot.
Rock
Lighting levels Overview
Updated Calculation Date: 10/06/21
9
Key Plan
Ref: X-P3
Fixtures’ location
Plan
Ref: X-P3
Spike mounted spotlight
3.5 W
164 lm
2700K
Mounting detail
Rock
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Plan
Ref: X-B1
Fixtures’ location
Note:
Ref: X-B1
Bollard Lighting
7.4 W
491 lm
2700K
Mounting detail
Typical Crossroads
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Note:
Perpendicular illuminance 0.69 lx 0.003 lx 312 lx
• This calculation is revised as per the DD comments.
• The Emax 312 lux, is identified on one point right under the luminaire, and
it’s unlikely to cause any disturbance or glare thanks to the significantly small
area of the hot spot.
Outdoor Lobby
Lighting levels Overview
Updated Calculation Date: 10/06/21
Petals
Plan
Note:
Petals
Ref: X-P3
Spike mounted spotlight
3.5 W
164 lm
2700K
36 deg
Ref: X-DF1
Bollard
5W
34 lm
2700K
H: 500mm
Outdoor Lobby
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Key Plan 12
Upwards Spill Light
Ref: X-DF3
Fixtures’ location
Plan
E av. 0.34 lux on the floor Material Codes & Material Reference Estimated
Description Image Reflectance
Floor Sand 0.4
Section
Calculation plane
Pathway near Cabana
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-DF3
Lantern
10 W
650 lm
2700K
H: 650mm
Pathway near Cabana
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Plan
Outwards spill light / Key Plan
vertical illuminance 13
Floor steps area E av. 0.11 lux
Horizontal illuminance 3
E av. 23.5 lux
Ref: X-UW3
Outwards spill light /
Fixtures’ location
2 vertical illuminance
E av. 0.15 lux
Ref: X-P8
Fixtures’ location
Note:
Calculation plane
Pool
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-UW3
Recessed lighting
for steps
6W
450 lm
40deg
3000K
Ref: X-UW1
Recessed lighting
for steps and walls
39 W/m
2652 lm
Grazing 14°x40°
3000K
L: 360mm
Ref: X-P8
Spotlight mounted
on palm trees
5W
550 lm
45 deg
3000K
Plan Section
Plan Section
Plan
Note:
2- Horizontal plane – Floor – Middle area • This calculation is revised as per the DD comments.
Properties E Emin Emax
• The Emax 1589 lux, is identified on one point right under the luminaire on the steps. And it’s
Perpendicular illuminance 15.2 lx 0.16 lx 1589 lx unlikely to be glary thanks to the significantly small area of the hotspot and the fact that this area is
used as a quick passage and not as a lounge.
BOH - Road
Lighting levels Overview
Updated Calculation Date: 10/06/21
Key Plan 14
Upwards Spill Light
Ref: X-W2
Fixtures’ location
Plan
Note:
Ref: X-W2
Material Codes & Material Reference Estimated
Fixtures’ location
Description Image Reflectance
Floor Sand 0.4
Section
Calculation plane
BOH - Road
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-W2
Wall Recessed Light
7.8 W
463 lm
2700K
Asymmetric / floor wash
Mounting detail
BOH - Road
Lighting Levels Overview
Updated Calculation Date: 10/06/21
Floor
Properties E Emin Emax
Reference image
Calculation
E av. 0.025 lux Upwards Spill Light surface
E max 0.24 lux
Petals
10 m
Note:
Calculation plane
Tree - Phoenix Atlantica
3D views – Luminaires Selection
Updated Calculation Date: 10/06/21
Ref: X-P1
Spike mounted spotlight
15 W
240 lm
Beam angle: 38
2700K
10 m
Key Plan
Property line
Maximum vertical
580m
illuminance is 0 lux
200m
450m
Built Area
Compliance with LEED and IES: