Professional Documents
Culture Documents
Screenshot 2024-02-16 at 11.55.34
Screenshot 2024-02-16 at 11.55.34
www.knyee-energy.com→
Catalog
About us
Product
Installation&use
Product
introduction Aftermarket
Solutions
About us
a
-gare
Product ZC-S51100(All-in-one
System)
ZC-L48100(RackMode
StorageBattery)
ZC-W51100(WallMounted
StorageBattery)
TowerHV(HighVoltage
StackedBattery)
Overview
KNYBEENERGY
KNYLITENERGY
XNYLIEENERCY
KNYENERGYSOLARINVERTER/IN
**111
★★★★★ ★★★★ ★★★★ ★★★★★
LH5K-SL/LH6K-SL(Single- LH8K-TH/LH1OK-TH(Three- KNY-8K-S/KNY-10K-S(All-in- KNY5500(All-in-oneSolar
phaseInverter5-6kw) phaseInverter8-10kw) oneSolarChargeInverter) ChargeInverter)
Off-grid On-grid
Off-grid (self-consumption) mode, the On-grid mode, the inverter can feed
inverter can store solar or utility grid excess power back to the grid,
power in batteries to meet the helping users get revenue from the
household's electricity needs. Users sale of electricity.
can also adjust the priorities of
different energy sources to maximize For customers who want to use clean
the use of electricity. energy to reduce their electricity bills
Suitable for customers who want to
have a stable power supply
A B
Self-generation, self-
consumption, surplus electricity User-defined mode
on the grid
The electricity generated by PV is
According to the user's own use of the
preferentially used by the load at home,
difference, can be customised to different
and the excess electricity of
needs of the programme, to do power
photovoltaics can be stored in the battery
generation, discharge, charging time
pack for the next power outage, or sold
period are chosen by the user, so that
to the grid at a certain price to make a
green energy within reach!
profit
Inverter parallel connection schematic
3 Photovoltaics charge the battery and carry the load 4 Mains bypass load
When the lighting conditions are good or the When there is no photovoltaic panels, use the mains to
household load power is within the power charge the battery, and use the battery as a UPS power
generated by the solar photovoltaic panel, the supply when needed to meet household electricity
excess part is charged to the battery needs
Mobile App
Users can view the inverter's
power generation curve and
parameters in real time on the
Diesel Generator mobile app, and can also
Mobile APP Inverter receive alerts when the
inverter breakdown.
Computer
Computer The user communicates with the
inverter through a specific PC host
software, and can upgrade the
firmware of the inverter software, as
well as modify and read operating
parameters, which is suitable for
Energy storage inverter BMS professionals to debug equipment.
• High-density lithium iron phosphate battery, safer to use and longer life
• Minimalist design, Exquisite appearance
• Wall-mounted installation, smaller size, but larger capacityMillisecond-level
• Expansion connection is convenient and fast plug and play at any time
• BMS communication management, safe, stable and reliable
• High-density lithium iron phosphate battery, safer to use and longer life
• All in one structure, easy and fast installation, plug and play at any time
• Can be easily modularized and expanded to meet more family needs
• Base wheel design, easy to move
• High-density lithium iron phosphate battery, safer to use and longer life
Client needs
Electrical Quantity Power(W) Daily electricity time(h) Total Power (WH) ① The daily power
equipment
According to the above table analysis, the total load commonly used by the family in one day is:10.064kW
The selected battery:The 48V, 100Ah battery module is connected to the 5.5kW off-grid all-in-one inverter through a DC switch. The battery power is 8kWh. Considering the
discharge depth of the battery (DOD=80%), the battery conversion efficiency is 94%, which can be used in practice. The capacity of the battery is: 3.60kWh, which requires about
three battery modules to be connected in parallel to meet the daily consumption of the family.
Each module consists of 100Ah batteries to form a 51.2v voltage battery module, 16 in series. 2 to 15 modules can be connected in parallel to expand the
capacity and power of the energy storage system. Adopt modular structure design. Each energy storage module integrates a BMS system, which can be easily
expanded, and a maximum of 75Kwh battery packs can be combined.
The power module adopts a new topological circuit design, which can realize the energy conversion between photovoltaic, mains, battery and load, and
has the function of photovoltaic and mains charging. Has a wide voltage range. The mains charging module adopts advanced control algorithm to realize full
digital double closed-loop control of voltage and current. High control precision and small size. The AC voltage input range is wide, and the input and output
protection functions are complete, which can realize stable and reliable charging and protection of the battery. The inverter module is based on the all-digital
intelligent design, adopts advanced SPWM technology, outputs pure sine waves, and converts DC power to AC power, which is suitable for AC loads such as
household appliances and electric tools.
Basic requirements :
When installing energy storage equipment, a certain ①: The battery fixing base should be placed in a
space should be left around it to ensure sufficient
suitable position first, the installation site should be
installation space and heat dissipation.
smooth, the ground should be solid, and the equipment
should be 30-50cm away from the wall
②: If there are multiple batteries, the first battery ③: Installers should pay attention to the direction
should be placed correctly before placing the others during installation. They should be installed vertically
and not tilted
Install the PCS module, the PCS module should be installed on the top,
not other positions
The signal cable delivered with the product is used to connect to the RS485 interface of
each battery module, and the communication port of the inverter needs to be connected to
the RS485-2 interface. The PV line should be distinguished from the +/- polar AC input
line and the AC output line. Correctly distinguish between L/N and grounding when wiring
to avoid short circuits
1. PV modules :
3. Energy storage battery : When the
Convert light energy into DC
solar energy is insufficient and there is
electricity , Charge the battery
through the inverter, or directly no mains power, ensure the normal
convert it into AC power to supply power consumption of the system
power to the load. load.
。
Real-time data viewing method
On the LCD main screen, press the "UP" and "DOWN" buttons to turn pages to view
various real-time data of the machine.
UP Previous selection
All products of our company have SN code (one item, one code), and track
the status of the product through the software background to realize the
detection of product installation and after-sale return