HUAWEI Imaster NCE-FAN V100R022C10 Data Sheet (Access Manager+Controller) 01

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

HUAWEI iMaster NCE Data Sheet

iMaster NCE-FAN | Access Manager+Controller

HUAWEI iMaster NCE is the industry's Product Description


first network automation and
intelligence platform that integrates With the advent of the all-optical network era and the next-generation
management, control, analysis, and AI passive optical network (NGPON), service providers are looking for
functions. It effectively connects innovative networks to prepare for the rapid traffic growth in the future.
physical networks with business The software-defined networking (SDN) technologies are used to improve
intents and implements centralized network agility for diversified new services. The network infrastructure must
management, control, and analysis of be ultra-broadband, simplified, open, agile, and intelligent, of which, the
global networks. It enables resource access network consists of optical network terminals (ONTs), multi-
cloudification, full-lifecycle network dwelling units (MDUs), and optical line terminals (OLTs). The access
automation, and data analytics-driven management and control O&M system simplifies network deployment,
intelligent closed-loop management improves O&M automation, reduces network capital expenditure (CAPEX),
according to business and service and improves O&M efficiency.
intents and provides open network
APIs for rapid integration with IT NCE is an integrated platform for network management, control, and
systems. Mainly applied in data center, analysis. It provides NE and ONT connection management capabilities in
enterprise campus, enterprise private the Access Manager and Controller scenario. Limited by carriers' business
line, and carrier network scenarios, it and O&M costs, it provides automatic network management processes and
accelerates service transformation and manages abstraction models of NE universal interfaces. This implements
innovation for carriers and enterprises visualized management of legacy networks and NETCONF/YANG NEs and
by improving the simplicity, helps carriers simplify O&M, improve O&M efficiency, and reduce field visits.
intelligence, openness, and security of
networks.
Architecture and Key Components
As the smart brain of the entire
network, NCE effectively connects the Based on a cloud architecture, NCE utilizes service-based module design
physical network to the business and supports distributed virtualization deployment. The overall architecture
intent. It has the following four key consists of modules such as common services, Manager & Controller,
capabilities: scenario-based apps, and southbound and northbound openness.
• All-cloud platform with ultra-large
system capacity
• Full-lifecycle automation
• Intelligent closed-loop
management based on big data
and AI
• Scenario-based application
ecosystem enabled by open
programmability

01 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


3rd-party App/OSS/Orchestrator Highlights
RESTful CORBA MTOSI/XML
NCE Open API
Common
Service
SNMP TL1 PONTL1 xFTP (Perf)
Service Automation
Build-in Apps Network Management Access Controller ONT ZTP: The ONT go-online and service configuration
SysMonitor
Manager & Controller processes can be customized. The design state is used to
HA Ethernet Multicast Protocol Diagnostic
view ONT ZTP
quickly adapt to the customer's process design and
management

Layer 2 VLAN NE management ETHOAM Network changes, reducing OSS changes and shortening the TTM.
Installation slice
& Simulation Energy
Deployment Site consumption
management test
Voice Template
Capability Openness
management
ONT ONT
Security management maintenance
Line
ACL &
Order PON leased
Based on the unified open architecture of the controller,
QoS
management line
Log
NCE provides standard RESTful NBI open network
Distributed
Resource Management capability models to accelerate service innovation.
management Resource Orchestration
License
framework
Alarm Inventory Topology
pool framework NETCONF/YANG SBIs and legacy interfaces are supported,
enabling network convergence management.
SBI SNMP SSH NETCONF xFTP HTTPS

Network infrastructure
DSLAM MSAN OLT MDU ONT
PON Leased Line O&M
PON leased line views can be customized.
Common service module: provides basic network services Allows users to view the overall information of ONUs, and
such as alarms and logs and product engineering details and alarm details of any ONU in the view.
capabilities such as disaster recovery (DR) and backup.
Network Slice
Manager & Controller: provides access network A hardware infrastructure network can be divided
management and control services, including: into multiple independent virtual networks, which
• Provisioning services on the access network, including can be flexibly combined and allocated with
provisioning Ethernet, multicast, and voice services, and resources on demand to meet different
managing VLANs, profiles, access control list (ACL) & requirements of various services. If the live network
quality of service (QoS), and lines corresponding to the cannot meet a new service requirement, carriers can
services. create a new virtual network without affecting the
• Managing access devices, including the management live network. In this way, the new service can be
of the central office (CO) devices and terminals such as provisioned as soon as possible.
the BITS, MSAN, DSLAM, OLT, and ONT, and
managing the environment monitoring sites OLT Centralized Management
corresponding to the CO devices. • Supports master frame resource management,
• Access network diagnosis and maintenance topology visualization, and Layer 2 service
management, including FTTH service diagnosis views, configuration in the OLT centralized
circuit and loop line tests and emulation tests for management system.
access media, and remote ONT maintenance and • Supports visualization, details query, and
management. management of master frame site resources in
• Access network automation: automatic ONT zero touch the OLT centralized management system.
provisioning (ZTP).
Energy Consumption Management
Scenario-based app: provides network management and This feature visualizes NE energy consumption,
automatic access capabilities for different business
helping users view and analyze network energy
scenarios.
consumption.
Northbound and southbound openness: provides NBIs
and SBIs for quick interconnection and integration with
third-party applications and other management and
control systems and devices.

02 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


Key Features ONT ZTP Based on ONT Service Packages
In scenarios where different services need to be created on
ONT ZTP Without Field Visits the ONT, the relationship between the ONT and services
can be determined only in the OSS provisioning phase. In
ONT ZTP mainly applies to the scenario where an this scenario, NCE provides the preset service package
ONT provisioning process is not available for carriers definition and ONT binding interface to configure and
who are ditching copper for fiber networks. deploy the ONT on demand.
Customers can apply for a customized ONT go-
OSS
online policy and preconfigure the policy. (Service provisioning system)
Immediately after an ONT is powered on, it is
authenticated on the cloud, and if it passes the
3. Bind ONTs to service
authentication based on the whitelist, configurations packages.
are applied to it according the preconfigured go- 2. Import the ONT
online policy. After the optical line has been whitelist. Pre-configure
deployed, services are provisioned with no field visit profiles and service 6. Add new online ONTs
packages. and configure service ports
required. NCE based on service packages.
5. NCE authenticates
ONTs on the cloud.

ONT ZTP Based on ONT Service Preconfiguration OLT


ONT
On NCE, preconfigure service packages, pre-add virtual
4. NCE automatically 1. Finish only basic
ONTs, and plan unique ONT aliases. When a real ONT discovers online ONTs. configurations, such as
goes online, a virtual ONT is mapped to the real ONT management channel
configuration, board hardware
based on the location of the real ONT and then added to
configuration, and global
the OLT. After the result is reported to the OSS and the system parameter
real ONT passes the OSS authentication, the virtual ONT configuration during OLT
deployment.
is changed to the real ONT, and the ONT service is Do not configure ONT and
automatically provisioned. service port data.

OSS
(Service provisioning system) Intelligent FTTx Site Management

5. NCE notifies the OSS The intelligent site management solution can be used for
that ONTs are
2. Import the ONT whitelist,
FTTx sites. Sensor components are used to avert black-box
launched.
configure service packages, management, remotely monitor site status in a visualized
and import pre-deployed
way, simplify door lock rights management, and remotely
ONT configurations to NCE. 6. Change the ONT SN
and alias to the SN and detect batteries. Site asset management, visualized site
NCE alias of the online ONT,
4. NCE authenticates monitoring, and remote operations reduce the number of
and activate the ONT.
ONTs on the cloud. site visits, facilitate remote site maintenance, and save on
maintenance costs.
OLT
ONT

3. NCE automatically 1. Pre-configure an


discovers online ONTs. access profile offline
during OLT deployment.

This scenario is similar to the P2P management mode of


the traditional copper line network. Each configured ONT
is equivalent to a P2P port. During subscriber provisioning,
select an ONT for service provisioning.

03 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


Remote Diagnosis PON Leased Line O&M

FTTC/FTTB diagnosis view: This view displays E2E links You can customize a PON private line view by configuring
from CPE UNIs to OLT upstream ports to implement one- the ONU type, ONU name matching rule, and ONU name
stop NE and link status monitoring and fault diagnosis. keyword.
With this view, FTTC/FTTB troubleshooting is simplified. After the configuration is complete, you can view the
overall information about ONUs (including the total
FTTH diagnosis view: This view displays E2E links from number of ONUs, number of online ONUs, number of
ONT UNIs to OLT upstream ports to implement one-stop offline ONUs, and number of ONUs that contain alarms)
NE and link status monitoring and fault diagnosis. With in the PON private line view. In addition, you can view the
this view, FTTH troubleshooting is simplified. details and alarm details of any ONU in the view.

Remote emulation test: Maintenance personnel can


remotely diagnose faults on voice, broadband, and other
services.

Intelligent alarm analysis: Alarm compression,


correlation analysis, and other methods are provided to
reduce the alarm quantity and help users identify root
causes.
Network Slice
NE data verification: NE configuration data is verified
against the data planned by carriers to avoid data Network slices are used to divide the physical network of a
inconsistency and the resultant service problems. carrier into multiple logical networks for different
purposes. Slicing enables carriers to build multiple
ONT video quality diagnosis: Faults of IPTV + cooperated dedicated, virtual, isolated, and on-demand logical
OTT videos can be quickly diagnosed and demarcated. networks on a physical network to meet different
NCE collects quality indicators in real time, displays them requirements of customers in different industries for
in a visualized manner, and compares them to quickly network capabilities (such as delay, bandwidth, and
demarcate faults. packet loss rate).
Network slicing has the following characteristics:
Northbound and Southbound Openness • Isolation: Different network slices are isolated from
each other. When a slice is abnormal, other slices are not
NCE supports the new RESTful NBI and traditional NBIs affected.
such as XML, CORBA, and SNMP for compatibility with • Flexibility: The network slice service, function, capacity,
new and existing evolvable networks. It covers all service level agreement (SLA), and connection relationship
scenarios such as network performance monitoring, can be customized based on different service requirements,
automatic service configuration, and network monitoring. and the slice lifecycle can be managed as required.
The NBIs provide various atomic APIs and scenario-based
APIs, greatly simplifying the integration of the northbound
OSS/IT system and shortening the TTM. The unified API
gateway provides a secure and reliable entry point for
access.

04 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


OLT Centralized Management Scenario-based App
The master OLT with complex functions is deployed in the Access Controller
central office (CO) equipment room, and the functions of
the remote slave OLT are simplified, so that device Access Controller provides automation capabilities for
management and deployment are simplified. NCE can access devices and preferentially builds automation
manage all OLTs on the entire network by managing only capabilities for SD-OLTs (next-generation OLTs),
the master OLT, which greatly reduces service including automatic service provisioning (ONT ZTP), and
management and maintenance costs. automatic network adjustment (device replacement).

Energy Consumption Management

NCE periodically collects energy consumption data of


network-wide NEs and displays the data in multi-
dimensional views, meeting customers' requirements for
visibility into access network energy consumption.

05 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


Specifications
Category Description

Management and control of NEs Basic network configuration and access service provisioning

Simplified access device installation and PnP ONU ZTP


Service provisioning
Automatic recovery of ONU after replacement

ONT ZTP with no field visits required ONT PnP


ONT available immediately after replacement
ONT self-service roaming

E2E diagnosis and remote repair E2E diagnosis view


Remote emulation test
Video quality diagnosis

Programmable NBIs Design state and running state capability of Design Studio

Operating Environment
On-Premises Deployment

Hardware Configuration Requirements of TaiShan 200 (Model 2280)

Hardware Model Requirement

512 GB server advanced TaiShan 200 (Model • CPUs: 2 x Kunpeng 920 (2.6 GHz, 64 cores)
configuration 2280) • RAM: 16 x 32 GB DDR4
• Hard disk: 12 x 1800 GB HDD or 12 x 1920 GB SSD
• RAID controller card: Avago3508 (2 GB cache) delivered,
compatible with PMC3152 (2 GB cache)
• NICs: 2 x 4 GE electrical ports + 2 x 2 10GE optical ports
delivered, compatible with 2 x 4 GE electrical ports + 2 x
2 10GE/25GE optical ports, 2 x 4 GE electrical ports + 2 x
4 10GE/25GE optical ports

06 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


TaiShan Servers Required

Service Scenario Network Scale Hardware Number of Servers

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 1


(Centralized system) configuration

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 3


(Distributed system) configuration

Manager+Controller < 100,000 equivalent NEs 512 GB server advanced 7


(Distributed system) configuration

Manager+Controller < 150,000 equivalent NEs 512 GB server advanced 9


(Distributed system) configuration

Hardware Configuration Requirements of 2288X V5

Hardware Model Requirement

512 GB server advanced 2288X V5 • CPUs: 2 x Xeon Gold 6238R (2.2GHz,28 Core)
configuration • RAM: 16 x 32 GB DDR4
• Hard disks: 12 x 1800 GB SAS HDD
• RAID controller card: Avago3508 (2 GB cache) delivered,
compatible with PMC3152 (2 GB cache)
• NICs: 4 x 2 GE electrical ports + 2 x 2 10GE optical ports
delivered, compatible with 2 x 4 GE electrical ports + 2 x
2 10GE/25GE optical ports

2288X V5 Servers Required

Service Scenario Network Scale Hardware Number of Servers

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 1


(Centralized system) configuration

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 3


(Distributed system) configuration

Manager+Controller < 100,000 equivalent NEs 512 GB server advanced 7


(Distributed system) configuration

Manager+Controller < 150,000 equivalent NEs 512 GB server advanced 9


(Distributed system) configuration

07 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


Hardware Configuration Requirements of RS221G1

Hardware Model Requirement

512 GB server advanced RS221G1 • CPUs: 2 x Xeon Gold 6238R (2.2GHz,28 Core)
configuration • RAM: 16 x 32 GB DDR4
• Hard disks: 12 x 1800 GB SAS HDD
• RAID controller card: Avago3508 (2 GB cache)
• NICs: 4 x 2 GE electrical ports + 2 x 2 10GE optical ports

RS221G1 Servers Required

Service Scenario Network Scale Hardware Number of Servers

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 1


(Centralized system) configuration

Manager+Controller < 30,000 equivalent NEs 512 GB server advanced 3


(Distributed system) configuration

Manager+Controller < 100,000 equivalent NEs 512 GB server advanced 7


(Distributed system) configuration

Manager+Controller < 150,000 equivalent NEs 512 GB server advanced 9


(Distributed system) configuration

Private Cloud Deployment


VM Resources Required

Service Scenario Network Scale VMs vCPUs Memory Storage


(GB) (GB)

Manager+Controller < 30,000 equivalent NEs 21 212 848 7400

Manager+Controller < 100,000 equivalent NEs 46 696 2784 24500

Manager+Controller < 150,000 equivalent NEs 60 872 3488 28900

08 | HUAWEI iMaster NCE Data Sheet | iMaster NCE-FAN | Access Manager+Controller


Software Configuration Requirements

Item Type Version Remarks

Delivered Virtualization FusionCompute 8.3.0 (onsite Used on the TaiShan server in the on-
software software installation) premises scenario.
configurations FusionCompute 8.3.0 (factory Used on the X86 server in the on-
installation) premises scenario.

OS EulerOS V200R010C00 Used on the TaiShan server in the on-


premises scenario and in the private
cloud scenario.
Used on the X86 server in the on-
premises scenario and in the private
cloud scenario.

Database GaussDB T V3 (also called OMP node


Gauss100 OLTP 1.5.1) NCE Manager
Controller

Compatible Virtualization FusionSphere OpenStack 22.1.0 Used only in the private cloud scenario.
software software FusionSphere OpenStack 8.0.0
configurations FusionSphere OpenStack 6.5.1

FusionCompute
8.0.0/8.0.0.SPC1/8.0.1/8.2.0

FusionCube 8.0.0 or later Used only on the X86 server in the


private cloud scenario.

OS EulerOS V200R007 (EulerOS 2.5),


EulerOS V200R008 (EulerOS 2.8),
and EulerOS V200R009 (EulerOS
2.9)

Trademark Statement
, , and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks, and trade names mentioned in
this document are the property of their respective holders.

General Disclaimer HUAWEI TECHNOLOGIES CO., LTD.


The information in this document may contain predictive statements including, without limitation, statements Huawei Industrial Base
regarding the future financial and operating results, future product portfolio, new technology, etc. There are a Bantian Longgang
number of factors that could cause actual results and developments to differ materially from those expressed Shenzhen 518129, P.R. China
or implied in the predictive statements. Therefore, such information is provided for reference purpose only and Tel: +86-755-28780808
constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. www.huawei.com
Copyright © Huawei Technologies Co., Ltd. 2023. All rights reserved.