Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ADVANCED SERIES METERS

BASED ON UP-TO DATE ADDAX TECHNOLOGY FOR RESIDENTIAL METERING


Datasheet

add new tech to your business!

© 2022 All Rights Reserved www.addgrup.com


ADVANCED SERIES METERS
BASED ON UP-TO DATE ADDAX TECHNOLOGY FOR RESIDENTIAL METERING

KWh Active energy (export/import)


KVArh Reactive energy (4 quadrants)
AD13A.1-11-1 VAh Apparent energy
MULTI-FUNCTION & MULTI-TARIFF
V
THREE-PHASE ELECTRONIC METERS A
Measured quantities
DESIGNED FOR USE IN AMI/AMR SYSTEM
Calculation of total harmonic
THD
distortion factor

OVERALL VIEW T1-T6 Multirate registration

Built-in clock

Event Log

Load profile

I1≠I2 Differential current detection

IP54 Protection level

Backup power supply

Standard data model,


open protocols

Optical port

Built-in relay

DISPLAY INDICATIONS Sensor of meter cover opening


Reactive Load
Measurement energy OBIS character Communication Credit Sensor of terminal block cover
direction codes state mode opening
Active energy
Active power Tariff
indicator
Parameter value kWh Magnetic field sensor
or text message kvarh Units
VA
Differential Phase RS-485 communication
current Err! presence interface
Clock Meter Terminal Battery Reason
error cover block cover state of basic relay Basic relay
state disconnection state
state PLC Power Line Communication

Authentication & Encryption

© 2022 All Rights Reserved www.addgrup.com


FUNCTIONALITY
DLMS/COSEM SUPPORT TEST OUTPUTS DATA TRANSMISSION
• Standard data model • Outputs: 2 optical outputs (LEDs), • Data transmission on demand
• Standard communication protocols optical port or by schedule
• Interoperability • Parameters under control: • Request types:
BUILT-IN CLOCK active energy, reactive energy - Concentrator request
• Real Time Clock (RTC), accuracy 0,5 s. (via communication channel)
BUILT-IN DISPLAY
• IEC 62052-21 standard compliant - Hand Held Unit request
• LCD, 8 digits, configurable decimal
• External synchronization (via optical port)
place (up to 3 digits)
• Daylight saving time support • Special symbols, data identification POWER LINE COMMUNICATION (PLC)
MEASURED QUANTITIES according to IEC 62056-61 (OBIS) - Built-in PLC modem
• Active energy, class B (1), • Metering data and specified messages - G3-PLC (ITU-T G.9903) compliant
export and import displaying - PRIME (ITU-T G.9904, PRIME
• Reactive energy, class 2; 4 quadrants • Service and client lists of parameters specifications v.1.3.6 and v.1.4)
• Apparent energy • Manual and automatic modes of screens standard compliant;
• Power, Max Demand scrolling - Switching between G3-PLC and PRIME
- integration period: • Display self-testing is performed by changing the meter
15’, 30’, 60’, 1 day • Configurable backlight mode firmware.
- average interval: day, month - PLC features:
LOAD CONTROL
• Phase voltage/current, instantaneous  CENELEC A
• Built-in relay (80 A)
value, RMS, neutral current, difference  FCC band
• Control modes:
between phase and neutral currents  EMC standards compliance
- remote (by command)
 Auto-discovery
METERING DATA - local (by condition)
 Repeating
• Actual meter readings - manual (by push button)
• Periodic meter readings: • Continuous relay state control RS-485 COMMUNICATION INTERFACE
daily, monthly • Relay status displaying • Built-in RS-485 interface with two
• Interval meter readings: • Load switch events registering paralleled outputs:
5’, 10’, 15’, 20’, 30’, 60' POWER LOAD CONTROL - provides a link between the meter
• Timestamp • 1 extra relay (2.5 A), which controls and an extension communication
external contactor of consumer’s module via mini USB port;
DATA STORAGE
appliances - ensures the power supply of
• Non-volatile memory
• Control modes: communication module;
• Capacity depends on data type
- remote (by command) - provides a link between the meter
and number of parameters and
- local (by schedule) and other devices via WAGO
can be expanded for one type of data on
• Events registering connectors
the expense of another
• Up to 3 interval profiles and 1 billing ELECTRICAL ENERGY QUALITY - baud rate - up to 19 200 bps.
profile. For example: CONTROL
COMMUNICATION MODULE
- 15 minutes interval profile: • Quality indexes:
• Two LEDs placed on the terminal block
6 parameters for about 63 days - average voltage
cover to reflect the state of
- hourly interval profile: - voltage sags and swells
communication module
6 parameters for about 13 days - outages
- network frequency OPTICAL PORT
- monthly billing profile:
- angles between phases • IEC 62056-21 standard compliant;
6 parameters for about 110 months
- THD for voltage/current harmonics • Data transmission rate 38400 bps;
MULTI-RATE METERING • Possibility of local data exchange and
• Remote or local configuring of
• Up to 6 tariff registers meter parameterization.
parameters thresholds
• Up to 12 changeovers per day • A possibility to install the optical port
• Quality events registering
• Tariff indicator is displayed on LCD and cap with sealing option is provided.
transmitted to HES FRAUD & THEFT PROTECTION
• Continuous monitoring; SOFTWARE UPDATE
• Active and passive tariff plans,
• Fraud types under control: • Remote (via communication channel) or
configurable activation time of the
- meter case cover opening local (via optical port);
passive tariff plan
- meter terminal block cover opening • Sw update events registering.
CALENDAR
- inadmissible differential current METER PARAMETERIZATION
• Up to 12 seasons per year
- strong external magnetic field • Remote (via communication channel) or
• Up to 7 daily profiles per week
• Hall sensor for magnetic field detection local (via optical port);
• Up to 30 special days per year
• Protective seals • Access rights assignment from HES;
• Support of movable holidays
• Fraud events registering BACKUP POWER SUPPLY
EVENTS & ALARMS HANDLING
THRESHOLDS MANAGEMENT • Battery for meter backup supply when
• Continuous control of current state of
• Configurable thresholds values the power is off
meter functional nodes and
• Possibility to disconnect consumer from • Battery lifetime - not less than 20
alarms/events, timestamps
the network, when a threshold is years.
• Standard set of events processing
crossed
including: registration in the special
INFORMATION SECURITY
logs and registers, event report
• Communication encryption
sending, states displaying, load
(AES-GCM-128 security suite)
switching off on special cases
• Data access according
• Different types of event logs
to access rights
METER SELF-CONTROL • Firmware protection
• Built-in test for continuous self-control • Secure events registering
• Quick response on severe error
• Meter state events registering

© 2022 All Rights Reserved www.addgrup.com


TECHINCAL SPECIFICATIONS TERMINAL BLOCK DIMENSIONS

Accuracy class:
- Active energy B (1)
- Reactive energy 2
Reference current, Iref 5A
Maximum current, Imax 80 A
Minimum current 0.05 Iref
Starting current:
- Active energy 0.004 Iref
- Reactive energy 0.005 Iref
Reference voltage, Un 3×230 V
Voltage range 0.8 Un ... 1.2 Un
Reference frequency 50 Hz
Meter constant: CONNECTION DIAGRAM (IEC)
- Active energy 1 000 imp/kWh
- Reactive energy 1 000 imp/kvarh
Temperature range -40°C … +70°C
Internal clock quartz crystal 32 kHz
Clock accuracy (at 25°C) (IEC 62052-21) ≤0.5 s /24 h
PLC raw data rate (with convolutional
coding):
21.4-64.3 kbps
- PRIME v1.3.6, CENELEC A band 3-95 kHz
5.4-64.3 kbps DESIGN FEATURES
- PRIME v1.4 for each of 1, 3-8 channel in
the band 3 kHz up to 500 kHz DESIGN
• Compliance with DIN 43857 standard
- G3-PLC CENELEC A band (35-90 kHz) up to 44 kbps
specifications
- G3-PLC FCC band (154-487 kHz) up to 230 kbps HOUSING
Inherent consumption of current circuit, • Light-tone non-flammable
2.5 VA
not more (IEC 62053-61) polycarbonate
MOUNTING
Inherent consumption of voltage circuit,
• By 3 fixing points or on DIN rail
active/total, per phase, 2 W / 10 V
(35mm)
not more (IEC 62053-61)
Insulation strength (IEC 61010-1-90) 4 kV, 50 Hz, 1 min CONTACT US

Impulse voltage (IEC 60060-1) 12 kV, 1.2/50 μs 36 Dragomirna str.


Electrostatic discharge (IEC 61000-4-2) 15 kV Kishinev MD-2008
High frequency radiant field Republic of Moldova
10 V/m
(IEC 61000-4-3) Phone : +373 (0) 22 930 012
High frequency interferences Fax : +373 (0) 22 930 012
4 kV
(IEC 61000-4-4)
E-mail : info@addgrup.com
Surge immunity (IEC 61000-4-5) 6 kV Web : www.addgrup.com
IP rating IP54
Mean total lifetime, not less 20 years
Dimensions, L x W x D 280 x 180 x 68 mm