9639 10000 9595

6944 2695 500 500 8000 500 500 2695 6900 TO AU-107 TO KAREGAON
PCL CD.NO.: 05
FRL:387.722 Type of Structure Minor Bridge
-2.5% -2.5%
1.5 1.5 A Design Chainage
Proposed Span (m)
0+861
2x3x3.0m
1 1 Remark New Construction

1949

1949
PROW

5949
PROW
PARAPET WALL PARAPET WALL

4000

4000

CH:0+800

CH:0+900
450
TOP SLAB KEY PLAN
D/S
U/S
NOTES :-

1000
WHEEP HOLES 1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS ARE IN METERS,

3000
3015
2.0 1000 2.0
TOE WALL UNLESS OTHERWISE SPECIFIED.
1 1
(450x900) 2. DIMENSIONS OF THE DRAWING SHALL NOT BE MEASURED
(TYP.) IL : 378.308 B IL : 378.323 FROM THE DRAWING. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
GL.+378.608 F GL.+378.623
3. CODES FOLLOWED FOR THE DESIGNS OF STRUCTURES:
1 in 1000

500
a) IRC: 5-2015 c) IRC: 112-2020
BOTTOM RAFT
b) IRC: 6-2017 d) IRC: 78-2014 e) IRC SP: 13-2004
150 THK PCC M15 4. GRADE OF CONCRETE SHALL BE AS FOLLOWS :-
LEVELLING COURSE LEVELLING COURSE ----------------- M15
CURTAIN
LHS RHS CURTAIN
WALL TYPE- I BOX CELL ----------------- M35
WALL TYPE- II
2695 10000 2695 PARAPET WALL ----------------- M30
6000 6930 15390 6900 3000 5. MINIMUM CLEAR COVER TO ANY REINFORCEMENT SHALL BE AS FOLLOWS :-
TOTAL LENGTH
300 THICK DRY STONE EARTH FACE ----------------- 75
PITCHING OVER 150 LONGITUDINAL SECTION A-A NON EARTH FACE ----------------- 40
THICK GRAVEL BACKING (TYP.) (SCALE 1: 100) 6. BACK FILLING FOR SIDE WALL AND RETAINING WALLS SHALL CONFORM
C TO SPECIFICATION APPENDIX-6 OF IRC : 78-2014.
B

TO KAREGAON
SLOPE 1V : 2.0H SLOPE 1V : 2.0H 7. THE PROPERTIES OF THE MATERIALS USED FOR BACK FILLING BEHIND
PCL SIDE WALL AND RETAINING WALLS SHALL CONFORM TO THE FOLLOWING
Ø < 30° & rd = 20 kN/m³
8. SOFT AND LOOSE PATCHES IN THE BEARING AREA ARE TO BE REPLACED
RETAINING WALL

RETAINING WALL
BY COMPACTED GRANULAR FILLS WITH LAYERS NOT EXCEEDING 300 .
LENGTH

LENGTH
9. COMPRESSIBLE FILLER BOARD SHALL BE PROVIDED IN ALL STRUCTURE GAPS
4678

4655
1V : 1.5H

PROVIDED BETWEEN STRUCTURES .


10. PROTECTION WORKS SHOULD BE DONE AS PER SITE

1V : 1.5H
CONDITION AND AS PER INSTRUCTIONS OF ENGINEER IN CHARGE.
11. ANY DISCREPANCY NOTED SHOULD BE REPORTED TO THE DESIGN
ENGINEER IMMEDIATELY.
12. THE SAFE BEARING CAPACITY CONSIDERED FOR THIS BOX STRUCTURE
500

IS 20.00 t/m². THE SAME SHALL BE CONFIRMED AT SITE BEFORE EXECUTION,


IF NOT PLEASE BRING NOTICE TO AUTHORITY ENGINEER/DETAILED DESIGN
X = 775448.9611 X = 775433.6125 CONSULTANCY. IF BLACK COTTON SOIL IS ENCOUNTERED AT SITE AT STURCTURE
Y = 2107007.3668 Y = 2107006.2396 LOCATION DURING CONSTRUCTION BLANKET MATERIAL SHALL BE
PROVIDED BELOW THE STRUCTURE.
3000

FLOW 13. ALL THE LEVELS AND CAMBERS TO BE VERIFIED WITH RESPECT TO
PARAPET WALL PARAPET WALL U/S PLAN AND PROFILE DRAWINGS BEFORE STARTING UP OF EXECUTION.
(TYP.) (TYP.)
14. BACK FILLING BEHIND WALLS SHALL BE DONE SIMULTANEOUSLY ON
D/S 300 THICK M15 1000 THICK
A EITHER SIDE OF THE STRUCTURE.
1000 THICK
400

CONCRETE (TYP.) 300 THICK M15 STONE APRON


STONE APRON CONCRETE (TYP.) (FLEXIBLE) 15. WEEP HOLES OF 100 DIA SHALL BE PROVIDED AT 1000 C/C
A (FLEXIBLE) BOTH HORIZONTALLY AND VERTICALLY IN A STAGGERED MANNER
IN SIDE WALLS OF BOX CELL AND RETAINING WALLS ABOVE 150
FROM GL OR LWL WHICHEVER IS HIGHER.
3000

FLOW 16. 600 THICK FILTER MEDIA SHALL BE PROVIDED BEHIND SIDE WALLS
AND RETAINING WALLS AS PER IRC : 78 - 2014.
X = 775448.4191 X = 775433.0705
Y = 2107014.7469 17. DRAINAGE SPOUT, COLLECTION PIT ASSEMBLY AND DRAINAGE PIPE SHALL
Y = 2107013.6197
BE FABRICATED FROM MILD STEEL AND AFTER THE COMPLETE ASSEMBLY,
500

EXCEPT GRATING, SHALL BE GIVEN A HOT DIPPED GALVANISED COATING.


18. FOR DETAILS OF RETAINING WALL REFER SEPARATE DRAWING.

1V : 1.5H
19. RETAINING WALL LENGTH AND HEIGHT VARIES AS PER SITE CONDITION.
20. ALL DIMENSIONS AND LEVELS SHOULD BE VERIFIED BEFORE EXECUTION
RETAINING WALL
RETAINING WALL
1V : 1.5H

TO AU-107

OF WORK.
LENGTH
LENGTH

21. FOR DETAILS OF APPROACH SLAB, CRASH BARRIER RCC POST AND DRAINAGE
4655
4678

SPOUT REFER MISCELLANEOUS DRAWING.


22. FLOOR PROTECTION WILL BE PROVIDED AT U/S AND
D/S, AS PER IRC SP: 13-2004.
23. VEHICULAR LOADS CONSIDERED IN DESIGN ARE AS FOLLOWS
a) 70R TRACKED LOAD b) 40T BOGIE LOAD
24. WEARING COAT OF 65mm THK CONSISTING 40mm BC AND 25mm MASTIC ASPHALT.

SLOPE 1V : 2.0H B SLOPE 1V : 2.0H IMPORTANT NOTE :


2695 10000 2695

C
* THE TOTAL LENGTH OF THE BOX STRUCTURE INCLUDING THE
SLOPE PROTECTION WORK SHALL FIT WITHIN ROW
6000 6930 15390 6900 3000
TOTAL LENGTH REFERENCE DRAWINGS:
PLAN (SCALE 1: 120) 1. REINFORCEMENT DETAILS : 413/STR/MNB/REINF./0+861/201

CLIENT: EPC CONTRACTOR: PROOF CONSULTANT: SAFETY CONSULTANT : DESIGN CONSULTANT: PROJECT: DRAWING TITLE: SCALE

GENERAL ARRANGEMENT DRAWING OF MINOR BRIDGE AT KM: 0+861 AS SHOWN

BOX TYPE (NEW CONSTRUCTION)


CONSTRUCTION OF BYPASS ROAD TO DATE
UMRI CITY KM 0+000 TO KM 3+600, FEB - 2024
DRAWING NUMBER: 413/STR/MNB/0+861/101 (SHEET NO.1 OF 3)
Sharda Construction & Corporation Pvt.Ltd. M/S Sankalp Consultancy Services R J CONSULTANCY SERVICES Padmapriya Consulting LLP TQ UMRI DIST, NANDED
R1 09-02-2024 REVISED AS PER LATEST P&P R.SAI Regd.Office:- Shop No.13, Mukteshwar ROAD AND HIGHWAY DESIGN ENGINEERS Hariviluu, House No. 24 155/15/1, Shipyard DRAWN REV
PUBLIC WORKS DEPARTMENT P.No.72, Sharda Towers, Plot No. 2, S. No. 10, Bhanudas Nagar, Akashwani
DESIGNED CHECKED APPROVED
Apartment, Layout, Vepagunta, Visakhapatnam,
R0 12-02-2024 INITIAL SUBMISSION R.SAI MAHARASHTRA Ashok Nagar, Nanded-5, Maharashtra. Vasantnagar, Nanded-431815 Road, Aurangabad - 431 001
HYDERABAD DIVISION Andhra Pradesh, Pin Code 530 047 GSSR R.SAI U.PHANI SK. SINGH R1
NO DATE REMARKS BY
TO AU-107 TO KAREGAON TO KAREGAON TO AU-107
65mm THK. METAL BEAM 65mm THK. METAL BEAM
WEARING COAT CRASH BARRIER WEARING COAT CRASH BARRIER
FRL FRL

SLOPE 1V : 1.5H SLOPE 1V : 1.5H

PARAPET WALL PARAPET WALL

RETAINING WALL RETAINING WALL

CUSHION CUSHION

450

450
1000 TOP SLAB 1000 1000 TOP SLAB 1000
1000

1000

1000

1000
600 THK 600 THK 600 THK 600 THK
FILTER MEDIA D FILTER MEDIA FILTER MEDIA D FILTER MEDIA
E E
20 20 20 20
STR. GAP STR. GAP STR. GAP STR. GAP
(TYP.) (TYP.) (TYP.) (TYP.)

3015

3015
150 THK 150 THK
300 THK 1 1 300 THK 1 1
FILTER MEDIA FILTER MEDIA
STONE PITCHING 1.5 1.5 STONE PITCHING 1.5 1.5
GL GL GL GL
300

300

300

300
IL : 378.308 500 IL : 378.308

500
BOTTOM SLAB BOTTOM SLAB

RETAINING WALL C SHEAR KEY RETAINING WALL RETAINING WALL C SHEAR KEY RETAINING WALL

4678 500 3000 400 3000 500 4678 4678 500 3000 400 3000 500 4678

SECTION AT B-B SECTION AT C-C


(SCALE 1: 75) (SCALE 1: 75)

387.509 387.722 387.809


FRL'S

500
500 500
0+857.30 0+861 0+864.70
CHAINAGE

TRAFFIC DIRECTION

2000

L
BOTTOM SLAB LEGEND :-
d

d-100

2000
20 Ø @ 2000c/c
U/S = UP STREAM FRL = FINISHED ROAD LEVEL
BAR IN BOTH DIRECTION IL = INVERT LEVEL
PCC CUT SURFACE GL = GROUND LEVEL

D/S = DOWN STREAM LHS = LEFT HAND SIDE


500

EPOXY RHS = RIGHT HAND SIDE


BOND E.S = EARTHEN SHOULDER

500
= LEVEL P.S = PAVED SHOULDER
EXP. = EXPANSION
B TYP. = TYPICAL
C
L = CENTRE LINE
PCL = PROPOSED CENTRE LINE
TYPICAL ROCK ANCHORAGE DETAILS THK = THICK
L= LENGTH OF THE BOTTOM SLAB MCB = METAL BEAM CRASH BARRIER
B= WIDTH OF THE BOTTOM SLAB

IMPORTANT NOTE:-
1. SHEAR KEY CAN BE NEGLECTED IF THE BOTTOM SLAB IS RESTING ON THE ROCK SURFACE.
PROVIDE ROCK ANCHORAGE AT EVERY 2.0m INTERVAL IN BOTH DIRECTIONS.
2. PROVISION OF RIGID AND FLEXIBLE APRONS ARE SUBJECTED TO SITE CONDITION.
(SHEET NO.2 OF 3)
CLIENT: EPC CONTRACTOR: PROOF CONSULTANT: SAFETY CONSULTANT : DESIGN CONSULTANT: PROJECT: DRAWING TITLE: SCALE

GENERAL ARRANGEMENT DRAWING OF MINOR BRIDGE AT KM: 0+861 AS SHOWN

BOX TYPE (NEW CONSTRUCTION)


CONSTRUCTION OF BYPASS ROAD TO DATE
UMRI CITY KM 0+000 TO KM 3+600, FEB - 2024
DRAWING NUMBER: 413/STR/MNB/0+861/101
Sharda Construction & Corporation Pvt.Ltd. M/S Sankalp Consultancy Services R J CONSULTANCY SERVICES Padmapriya Consulting LLP TQ UMRI DIST, NANDED
R1 09-02-2024 REVISED AS PER LATEST P&P R.SAI Regd.Office:- Shop No.13, Mukteshwar ROAD AND HIGHWAY DESIGN ENGINEERS Hariviluu, House No. 24 155/15/1, Shipyard DRAWN REV
PUBLIC WORKS DEPARTMENT P.No.72, Sharda Towers, Plot No. 2, S. No. 10, Bhanudas Nagar, Akashwani
DESIGNED CHECKED APPROVED
Apartment, Layout, Vepagunta, Visakhapatnam,
R0 12-02-2024 INITIAL SUBMISSION R.SAI MAHARASHTRA Ashok Nagar, Nanded-5, Maharashtra. Vasantnagar, Nanded-431815 Road, Aurangabad - 431 001
HYDERABAD DIVISION Andhra Pradesh, Pin Code 530 047 GSSR R.SAI U.PHANI SK. SINGH R1
NO DATE REMARKS BY
65mm THK. WEARING COAT
20 500
300 mm THICK EXP.GAP
M15 CONCRETE
CONSTRUCTION
6000 6930
JOINT
125 200

EQ EQ EQ
300
1000

150
100

450
100

750
COMPACTED EARTH HAUNCH
450 300x300 TOP SLAB
150 mm THICK PCC M15

2500
LEVELLING COURSE
1000 THICK

750
STONE APRON COMPACTED EARTH 750
HAUNCH
300x300

500
450 450
BOTTOM SLAB 100 100

550
PCC M15 100

150 THICK EQ EQ EQ
PCC M15 CONSTRUCTION 20
1650 JOINT EXP.GAP
100 100 P.C.C M15
TYPICAL CROSS SECTION DETAIL-C 500
OF CURTAIN WALL TYPE-I (SCALE 1:25)
(SCALE 1:50)
DETAIL-D
(SCALE 1:25)

6900
3000
300 mm THICK 1000 THICK
M15 CONCRETE 200 125 STONE APRON

300

1000
150
750

COMPACTED EARTH
2000

150 mm THICK PCC M15 450


LEVELLING COURSE 500 2695
425 425
800

COMPACTED
PCC M15 EARTH

150 THICK
PCC M15 METAL BEAM
CRASH BARRIER
1300
150 150
65mm THK.
TYPICAL CROSS SECTION WEARING COURSE

OF CURTAIN WALL TYPE-II -2.5%


(SCALE 1:50)

400
65mm THK. WEARING COAT
1.5
1

1100
BED LEVEL

INVERT LEVEL
DRY STONE
500

PITCHING
2.0
1
(MIN)

450

450
PARAPET WALL
1200

TOP SLAB TOP SLAB

150 300 150 THICK PCC M15


1 LEVELLING COURSE
150
1 COMPACTED EARTH TOE WALL HAUNCH HAUNCH

4000
(450x900) 300x300 300x300
DETAIL-B 100 100
HAUNCH
100 250x250
(SHOWING DIMENSIONAL P.C.C M15
DETAIL-F EQ EQ EQ
DETAILS OF SHEAR KEY) (SCALE 1: 50)
CONSTRUCTION
JOINT
(SCALE 1:50)

450
TOP SLAB
400

DETAIL-E
(SCALE 1:25)
DETAIL-A
(SCALE 1: 25)

(SHEET NO.3 OF 3)
CLIENT: EPC CONTRACTOR: PROOF CONSULTANT: SAFETY CONSULTANT : DESIGN CONSULTANT: PROJECT: DRAWING TITLE: SCALE

GENERAL ARRANGEMENT DRAWING OF MINOR BRIDGE AT KM: 0+861 AS SHOWN

BOX TYPE (NEW CONSTRUCTION)


CONSTRUCTION OF BYPASS ROAD TO DATE
UMRI CITY KM 0+000 TO KM 3+600, FEB - 2024
DRAWING NUMBER: 413/STR/MNB/0+861/101
Sharda Construction & Corporation Pvt.Ltd. M/S Sankalp Consultancy Services R J CONSULTANCY SERVICES Padmapriya Consulting LLP TQ UMRI DIST, NANDED
R1 09-02-2024 REVISED AS PER LATEST P&P R.SAI Regd.Office:- Shop No.13, Mukteshwar ROAD AND HIGHWAY DESIGN ENGINEERS Hariviluu, House No. 24 155/15/1, Shipyard DRAWN REV
PUBLIC WORKS DEPARTMENT P.No.72, Sharda Towers, Plot No. 2, S. No. 10, Bhanudas Nagar, Akashwani
DESIGNED CHECKED APPROVED
Apartment, Layout, Vepagunta, Visakhapatnam,
R0 12-02-2024 INITIAL SUBMISSION R.SAI MAHARASHTRA Ashok Nagar, Nanded-5, Maharashtra. Vasantnagar, Nanded-431815 Road, Aurangabad - 431 001
HYDERABAD DIVISION Andhra Pradesh, Pin Code 530 047 GSSR R.SAI U.PHANI SK. SINGH R1