Tropical Heat Pump

R410A(50Hz/60Hz)
0CVV0-01A

P/No. : MFL67474056
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 8 10
Combination Unit ARUN080LTH5 ARUN100LTH5
ARUN080LTH5 ARUN100LTH5
Model Name
Independent Unit

RT 6.4 8.0
*Cooling (Rated) kW 22.4 28.0
Btu/h 76,400 95,500
RT 5.6 7.1
Capacity **Cooling (Rated) kW 19.8 25.0
Btu/h 67,600 85,300
RT 7.2 8.6
Heating (Rated) kW 25.2 30.3
Btu/h 86,000 103,400
*Cooling (Rated) kW 5.00 7.00
Input **Cooling (Rated) kW 6.37 8.33
Heating (Rated) kW 5.80 7.30
*Cooling kW/kW 4.48 4.00
EER
**Cooling kW/kW 3.11 3.00
COP Heating kW/kW 4.34 4.15
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 62.1
Number of Revolution rev/min 3,600 3,600
Compressor
Motor Output x Number W x No. 5,300 × 1 5,300 × 1
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 1,200 × 1 1,200 × 1
m3/min 240 × 1 240 × 1
Air Flow Rate(High)
Fan ft3/min 8,476 × 1 8,476 × 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 9.52(3/8) 9.52(3/8)
Connctions Gas mm(inch) 19.05(3/4) 22.2(7/8)
mm (930 × 1,690 × 760) × 1 (930 × 1,690 × 760) × 1
Dimensions(W x H x D)
inch (36-5/8 × 66-17/32 × 29-29/32) × 1 (36-5/8 × 66-17/32 × 29-29/32) × 1
kg 173 × 1 173 × 1
Net Weight
lbs 381 × 1 381 × 1
Sound Cooling dB(A) 58.0 58.5
Pressure Level Heating dB(A) 60.0 60.5
Sound Power Cooling dB(A) 78.0 79.0
Level Heating dB(A) 80.0 80.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

2
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 8 10
Combination Unit ARUN080LTH5 ARUN100LTH5
ARUN080LTH5 ARUN100LTH5
Model Name
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 4.7 4.7
Precharged Amount
Refigerant lbs 10.4 10.4
t-CO2 eq 9.8 9.8
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 13 16
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

3
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 12 14
Combination Unit ARUN120LTH5 ARUN140LTH5
ARUN120LTH5 ARUN140LTH5
Model Name
Independent Unit

RT 9.5 11.1
*Cooling (Rated) kW 33.6 39.2
Btu/h 114,600 133,800
RT 8.9 10.5
Capacity **Cooling (Rated) kW 31.2 36.8
Btu/h 106,500 125,600
RT 10.7 12.5
Heating (Rated) kW 37.8 43.9
Btu/h 129,000 149,900
*Cooling (Rated) kW 8.00 9.30
Input **Cooling (Rated) kW 9.54 11.20
Heating (Rated) kW 8.06 9.69
*Cooling kW/kW 4.20 4.22
EER
**Cooling kW/kW 3.27 3.29
COP Heating kW/kW 4.69 4.53
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 62.1
Number of Revolution rev/min 3,600 3,600
Compressor
Motor Output x Number W x No. 5,300 × 1 5,300 × 1
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 1,200 × 1 900 × 2
m3/min 240 × 1 320 × 1
Air Flow Rate(High)
Fan ft3/min 8,476 × 1 11,301 × 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 12.7(1/2) 12.7(1/2)
Connctions Gas mm(inch) 28.58(1-1/8) 28.58(1-1/8)
mm (930 × 1,690 × 760) × 1 (1,240 × 1,690 × 760)×1
Dimensions(W x H x D)
inch (36-5/8 × 66-17/32 × 29-29/32) × 1 (48-13/16 × 66-17/32 × 29-29/32) × 1
kg 200 × 1 221 × 1
Net Weight
lbs 441 × 1 487 × 1
Sound Cooling dB(A) 59.0 60.0
Pressure Level Heating dB(A) 60.0 61.0
Sound Power Cooling dB(A) 79.0 82.0
Level Heating dB(A) 80.0 84.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

4
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 12 14
Combination Unit ARUN120LTH5 ARUN140LTH5
ARUN120LTH5 ARUN140LTH5
Model Name
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 10.0 13.0
Precharged Amount
Refigerant lbs 22.0 28.7
t-CO2 eq 20.9 27.1
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 20 23
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

5
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 16 18
Combination Unit ARUN160LTH5 ARUN180LTH5
ARUN160LTH5 ARUN180LTH5
Model Name
Independent Unit

RT 12.7 14.3
*Cooling (Rated) kW 44.8 50.4
Btu/h 152,900 172,000
RT 11.4 12.4
Capacity **Cooling (Rated) kW 40.3 43.6
Btu/h 137,500 148,800
RT 14.2 16.1
Heating (Rated) kW 50.0 56.7
Btu/h 170,600 193,500
*Cooling (Rated) kW 10.80 11.20
Input **Cooling (Rated) kW 13.15 14.39
Heating (Rated) kW 11.36 11.98
*Cooling kW/kW 4.15 4.50
EER
**Cooling kW/kW 3.06 3.03
COP Heating kW/kW 4.40 4.73
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 62.1 × 1 + 43.8 × 1
Number of Revolution rev/min 3,600 3,600 × 2
Compressor
Motor Output x Number W x No. 5,300 × 1 5,300 × 1 + 4,200 × 1
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 2 900 × 2
m3/min 320 × 1 320 × 1
Air Flow Rate(High)
Fan ft3/min 11,301 × 1 11,301 × 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 12.7(1/2) 15.88(5/8)
Connctions Gas mm(inch) 28.58(1-1/8) 28.58(1-1/8)
mm (1,240 × 1,690 × 760)×1 (1,240 × 1,690 × 760)×1
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 1 (48-13/16 × 66-17/32 × 29-29/32) × 1
kg 221 × 1 261 × 1
Net Weight
lbs 487 × 1 575 × 1
Sound Cooling dB(A) 60.5 61.0
Pressure Level Heating dB(A) 61.5 62.0
Sound Power Cooling dB(A) 83.0 85.0
Level Heating dB(A) 85.0 86.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

6
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 16 18
Combination Unit ARUN160LTH5 ARUN180LTH5
ARUN160LTH5 ARUN180LTH5
Model Name
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 13.0 12.0
Precharged Amount
Refigerant lbs 28.7 26.5
t-CO2 eq 27.1 25.1
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 26 29
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

7
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 20 22
Combination Unit ARUN200LTH5 ARUN220LTH5
ARUN200LTH5 ARUN220LTH5
Model Name
Independent Unit

RT 15.9 17.5
*Cooling (Rated) kW 56.0 61.6
Btu/h 191,100 210,200
RT 13.6 14.1
Capacity **Cooling (Rated) kW 48.0 49.6
Btu/h 163,800 169,100
RT 17.9 19.7
Heating (Rated) kW 63.0 69.3
Btu/h 215,000 236,500
*Cooling (Rated) kW 13.00 14.84
Input **Cooling (Rated) kW 15.77 16.72
Heating (Rated) kW 15.52 17.54
*Cooling kW/kW 4.31 4.15
EER
**Cooling kW/kW 3.04 2.96
COP Heating kW/kW 4.06 3.95
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 2 62.1 × 2
Number of Revolution rev/min 3,600 × 2 3,600 × 2
Compressor
Motor Output x Number W x No. 5,300 × 2 5,300 × 2
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 2 900 × 2
m3/min 320 × 1 320 × 1
Air Flow Rate(High)
Fan ft3/min 11,301 × 1 11,301 × 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 15.88(5/8) 15.88(5/8)
Connctions Gas mm(inch) 28.58(1-1/8) 28.58(1-1/8)
mm (1,240 × 1,690 × 760)×1 (1,240 × 1,690 × 760)×1
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 1 (48-13/16 × 66-17/32 × 29-29/32) × 1
kg 281 × 1 281 × 1
Net Weight
lbs 619 × 1 619 × 1
Sound Cooling dB(A) 62.0 64.5
Pressure Level Heating dB(A) 64.5 65.5
Sound Power Cooling dB(A) 86.0 86.0
Level Heating dB(A) 87.0 88.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

8
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 20 22
Combination Unit ARUN200LTH5 ARUN220LTH5
ARUN200LTH5 ARUN220LTH5
Model Name
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 14.0
Precharged Amount
Refigerant lbs 30.9 30.9
t-CO2 eq 29.2 29.2
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 32 35
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

9
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 24 26
Combination Unit ARUN240LTH5 ARUN260LTH5
ARUN120LTH5 ARUN140LTH5
Model Name ARUN120LTH5 ARUN120LTH5
Independent Unit

RT 19.1 20.7
*Cooling (Rated) kW 67.2 72.8
Btu/h 229,300 248,400
RT 17.7 19.3
Capacity **Cooling (Rated) kW 62.4 68.0
Btu/h 212,900 232,000
RT 21.5 23.2
Heating (Rated) kW 75.6 81.7
Btu/h 257,900 278,800
*Cooling (Rated) kW 16.00 17.30
Input **Cooling (Rated) kW 19.08 20.74
Heating (Rated) kW 16.12 17.75
*Cooling kW/kW 4.20 4.21
EER
**Cooling kW/kW 3.27 3.28
COP Heating kW/kW 4.69 4.60
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 2 62.1 × 2
Number of Revolution rev/min 3,600 × 2 3,600 × 2
Compressor
Motor Output x Number W x No. 5,300 × 2 5,300 × 2
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 1,200 × 2 (900 × 2) + (1,200 × 1)
m3/min 240 × 2 (320 × 1) + (240 × 1)
Air Flow Rate(High)
Fan ft3/min 8,476 × 2 (1,1301 × 1) + (8,476 × 1)
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 15.88(5/8) 19.05(3/4)
Connctions Gas mm(inch) 34.9(1-3/8) 34.9(1-3/8)
(1,240 × 1,690 × 760) ×1
mm (930 × 1,690 × 760) × 2
+ (930 × 1,690 × 760) × 1
Dimensions(W x H x D)
(48-13/16 × 66-17/32 × 29-29/32) × 1
inch (36-5/8 × 66-17/32 × 29-29/32) × 2
+ (36-5/8 × 66-17/32 × 29-29/32) × 1
kg 200 × 2 (221 × 1) + (200 × 1)
Net Weight
lbs 441 × 2 (487 × 1) + (441 × 1)
Sound Cooling dB(A) 62.0 62.5
Pressure Level Heating dB(A) 63.0 63.5
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

10
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 24 26
Combination Unit ARUN240LTH5 ARUN260LTH5
ARUN120LTH5 ARUN140LTH5
Model Name ARUN120LTH5 ARUN120LTH5
Independent Unit

Sound Power Cooling dB(A) 82.0 83.8


Level Heating dB(A) 83.0 85.5
High pressure protection High pressure sensor / High pressure switch
Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 10.0 + 10.0 13.0 + 10.0
Precharged Amount
Refigerant lbs 22.0 + 22.0 28.7 + 22.0
t-CO2 eq 41.8 48.0
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 39 42
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

11
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 28 30
Combination Unit ARUN280LTH5 ARUN300LTH5
ARUN160LTH5 ARUN160LTH5
Model Name ARUN120LTH5 ARUN140LTH5
Independent Unit

RT 22.3 23.9
*Cooling (Rated) kW 78.4 84.0
Btu/h 267,500 286,600
RT 20.3 21.9
Capacity **Cooling (Rated) kW 71.5 77.1
Btu/h 244,000 263,100
RT 24.9 26.7
Heating (Rated) kW 87.8 93.9
Btu/h 299,600 320,500
*Cooling (Rated) kW 18.80 20.10
Input **Cooling (Rated) kW 22.69 24.35
Heating (Rated) kW 19.42 21.05
*Cooling kW/kW 4.17 4.18
EER
**Cooling kW/kW 3.15 3.17
COP Heating kW/kW 4.52 4.46
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 2 62.1 × 2
Number of Revolution rev/min 3,600 × 2 3,600 × 2
Compressor
Motor Output x Number W x No. 5,300 × 2 5,300 × 2
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W (900 × 2) + (1,200 × 1) 900 × 4
m3/min (320 × 1) + (240 × 1) 320 × 2
Air Flow Rate(High)
Fan ft3/min (1,1301 × 1) + (8,476 × 1) 11,301 × 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 34.9(1-3/8) 34.9(1-3/8)
(1,240 × 1,690 × 760) ×1
mm (1,240 × 1,690 × 760) × 2
+ (930 × 1,690 × 760) × 1
Dimensions(W x H x D)
(48-13/16 × 66-17/32 × 29-29/32) × 1
inch (48-13/16 × 66-17/32 × 29-29/32) × 2
+ (36-5/8 × 66-17/32 × 29-29/32) × 1
kg (221 × 1) + (200 × 1) 221 × 2
Net Weight
lbs (487 × 1) + (441 × 1) 487 × 2
Sound Cooling dB(A) 62.8 63.3
Pressure Level Heating dB(A) 63.8 64.3
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

12
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 28 30
Combination Unit ARUN280LTH5 ARUN300LTH5
ARUN160LTH5 ARUN160LTH5
Model Name ARUN120LTH5 ARUN140LTH5
Independent Unit

Sound Power Cooling dB(A) 84.5 85.5


Level Heating dB(A) 86.2 87.5
High pressure protection High pressure sensor / High pressure switch
Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 13.0+ 10.0 13.0+ 13.0
Precharged Amount
Refigerant lbs 28.7 + 22.0 28.7 + 28.7
t-CO2 eq 48.0 54.3
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 45 49
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

13
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 32 34
Combination Unit ARUN320LTH5 ARUN340LTH5
ARUN160LTH5 ARUN180LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit

RT 25.4 27.0
*Cooling (Rated) kW 89.6 95.2
Btu/h 305,700 324,800
RT 22.9 23.8
Capacity **Cooling (Rated) kW 80.6 83.9
Btu/h 275,000 286,300
RT 28.4 30.3
Heating (Rated) kW 100.0 106.7
Btu/h 341,200 364,100
*Cooling (Rated) kW 21.60 22.00
Input **Cooling (Rated) kW 26.30 27.54
Heating (Rated) kW 22.72 23.34
*Cooling kW/kW 4.15 4.33
EER
**Cooling kW/kW 3.06 3.05
COP Heating kW/kW 4.40 4.57
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 2 (62.1 × 2) + (43.8 × 1)
Number of Revolution rev/min 3,600 × 2 3,600 × 3
Compressor
Motor Output x Number W x No. 5,300 × 2 (5,300 × 2) + (4,200 × 1)
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 4 900 × 4
m3/min 320 × 2 320 × 2
Air Flow Rate(High)
Fan ft3/min 11,301 × 2 11,301 × 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 34.9(1-3/8) 34.9(1-3/8)
mm (1,240 × 1,690 × 760) × 2 (1,240 × 1,690 × 760) × 2
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 2 (48-13/16 × 66-17/32 × 29-29/32) × 2
kg 221 × 2 (261 × 1) + (221 × 1)
Net Weight
lbs 487 × 2 (575 × 1) + (487 × 1)
Sound Cooling dB(A) 63.5 63.8
Pressure Level Heating dB(A) 64.5 64.8
Sound Power Cooling dB(A) 86.0 87.1
Level Heating dB(A) 88.0 88.5
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

14
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 32 34
Combination Unit ARUN320LTH5 ARUN340LTH5
ARUN160LTH5 ARUN180LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 13.0 + 13.0 12.0 + 13.0
Precharged Amount
Refigerant lbs 28.7 + 28.7 26.5 + 28.7
t-CO2 eq 54.3 52.2
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 52 55
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

15
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 36 38
Combination Unit ARUN360LTH5 ARUN380LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit

RT 28.6 30.2
*Cooling (Rated) kW 100.8 106.4
Btu/h 343,900 363,000
RT 25.1 25.5
Capacity **Cooling (Rated) kW 88.3 89.9
Btu/h 301,300 306,600
RT 32.1 33.9
Heating (Rated) kW 113.0 119.3
Btu/h 385,600 407,100
*Cooling (Rated) kW 23.80 25.64
Input **Cooling (Rated) kW 28.92 29.87
Heating (Rated) kW 26.88 28.90
*Cooling kW/kW 4.24 4.15
EER
**Cooling kW/kW 3.05 3.01
COP Heating kW/kW 4.20 4.13
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 3 62.1 × 3
Number of Revolution rev/min 3,600 × 3 3,600 × 3
Compressor
Motor Output x Number W x No. 5,300 × 3 5,300 × 3
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 4 900 × 4
m3/min 320 × 2 320 × 2
Air Flow Rate(High)
Fan ft3/min 11,301 × 2 11,301 × 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 2 (1,240 ×1,690 × 760) × 2
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 2 (48-13/16 × 66-17/32 × 29-29/32) × 2
kg (281 × 1) + (221 × 1) (281 × 1) + (221 × 1)
Net Weight
lbs (619 × 1) + (487 × 1) (619 × 1) + (487 × 1)
Sound Cooling dB(A) 64.3 66.0
Pressure Level Heating dB(A) 66.3 67.0
Sound Power Cooling dB(A) 87.8 87.8
Level Heating dB(A) 89.1 89.8
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

16
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 36 38
Combination Unit ARUN360LTH5 ARUN380LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 13.0 14.0 + 13.0
Precharged Amount
Refigerant lbs 30.9 + 28.7 30.9 + 28.7
t-CO2 eq 56.4 56.4
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 58 61
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

17
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 40 42
Combination Unit ARUN400LTH5 ARUN420LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN200LTH5 ARUN200LTH5
Independent Unit

RT 31.8 33.4
*Cooling (Rated) kW 112.0 117.6
Btu/h 382,100 401,300
RT 27.3 27.7
Capacity **Cooling (Rated) kW 96.0 97.6
Btu/h 327,600 332,900
RT 35.8 37.6
Heating (Rated) kW 126.0 132.3
Btu/h 429,900 451,400
*Cooling (Rated) kW 26.00 27.84
Input **Cooling (Rated) kW 31.54 32.49
Heating (Rated) kW 31.04 33.06
*Cooling kW/kW 4.31 4.22
EER
**Cooling kW/kW 3.04 3.00
COP Heating kW/kW 4.06 4.00
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 4 62.1 × 4
Number of Revolution rev/min 3,600 × 4 3,600 × 4
Compressor
Motor Output x Number W x No. 5,300 × 4 5,300 × 4
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 4 900 × 4
m3/min 320 × 2 320 × 2
Air Flow Rate(High)
Fan ft3/min 11,301 × 2 11,301 × 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 2 (1,240 ×1,690 × 760) × 2
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 2 (48-13/16 × 66-17/32 × 29-29/32) × 2
kg 281 × 2 281 × 2
Net Weight
lbs 619 × 2 619 × 2
Sound Cooling dB(A) 65.0 66.4
Pressure Level Heating dB(A) 67.5 68.0
Sound Power Cooling dB(A) 89.0 89.0
Level Heating dB(A) 90.0 90.5
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

18
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 40 42
Combination Unit ARUN400LTH5 ARUN420LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN200LTH5 ARUN200LTH5
Independent Unit

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 14.0 14.0 + 14.0
Precharged Amount
Refigerant lbs 30.9 + 30.9 30.9 + 30.9
t-CO2 eq 58.5 58.5
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

19
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 44 46
Combination Unit ARUN440LTH5 ARUN460LTH5
ARUN220LTH5 ARUN160LTH5
Model Name ARUN220LTH5 ARUN160LTH5
Independent Unit
ARUN140LTH5

RT 35.0 36.6
*Cooling (Rated) kW 123.2 128.8
Btu/h 420,400 439,500
RT 28.2 33.3
Capacity **Cooling (Rated) kW 99.2 117.4
Btu/h 338,200 400,600
RT 39.4 40.9
Heating (Rated) kW 138.6 143.9
Btu/h 472,900 491,000
*Cooling (Rated) kW 29.68 30.90
Input **Cooling (Rated) kW 33.44 37.50
Heating (Rated) kW 35.08 32.41
*Cooling kW/kW 4.15 4.17
EER
**Cooling kW/kW 2.97 3.13
COP Heating kW/kW 3.95 4.44
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 4 62.1 × 3
Number of Revolution rev/min 3,600 × 4 3,600 × 3
Compressor
Motor Output x Number W x No. 5,300 × 4 5,300 × 3
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 4 900 × 6
m3/min 320 × 2 320 × 3
Air Flow Rate(High)
Fan ft3/min 1,1301 ×2 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 2 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 2 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg 281 × 2 221 × 3
Net Weight
lbs 619 × 2 487 × 3
Sound Cooling dB(A) 67.5 65.1
Pressure Level Heating dB(A) 68.5 66.1
Sound Power Cooling dB(A) 89.0 87.5
Level Heating dB(A) 91.0 89.5
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

20
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 44 46
Combination Unit ARUN440LTH5 ARUN460LTH5
ARUN220LTH5 ARUN160LTH5
Model Name ARUN220LTH5 ARUN160LTH5
Independent Unit
ARUN140LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 14.0 13.0 + 13.0 + 13.0
Precharged Amount
Refigerant lbs 30.9 + 30.9 28.7 + 28.7 + 28.7
t-CO2 eq 58.5 81.4
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

21
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 48 50
Combination Unit ARUN480LTH5 ARUN500LTH5
ARUN160LTH5 ARUN180LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

RT 38.2 39.8
*Cooling (Rated) kW 134.4 140.0
Btu/h 458,600 477,700
RT 34.3 35.3
Capacity **Cooling (Rated) kW 120.9 124.2
Btu/h 412,500 423,800
RT 42.6 44.5
Heating (Rated) kW 150.0 156.7
Btu/h 511,800 534,700
*Cooling (Rated) kW 32.40 32.80
Input **Cooling (Rated) kW 39.45 40.69
Heating (Rated) kW 34.08 34.70
*Cooling kW/kW 4.15 4.27
EER
**Cooling kW/kW 3.06 3.05
COP Heating kW/kW 4.40 4.52
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 3 (62.1 × 3) + (43.8 × 1)
Number of Revolution rev/min 3,600 × 3 3,600 × 4
Compressor
Motor Output x Number W x No. 5,300 × 3 (5,300 × 3) + (4,200 × 1)
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 6 900 × 6
m3/min 320 × 3 320 × 3
Air Flow Rate(High)
Fan ft3/min 11,301 × 3 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 3 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 3 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg 221 × 3 (261 × 1) + (221 × 2)
Net Weight
lbs 487 × 3 (575 × 1) + (487 × 2)
Sound Cooling dB(A) 65.3 65.4
Pressure Level Heating dB(A) 66.3 66.4
Sound Power Cooling dB(A) 87.8 88.5
Level Heating dB(A) 89.8 90.1
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

22
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 48 50
Combination Unit ARUN480LTH5 ARUN500LTH5
ARUN160LTH5 ARUN180LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 13.0 + 13.0 + 13.0 12.0 + 13.0 + 13.0
Precharged Amount
Refigerant lbs 28.7 + 28.7 + 28.7 26.5 + 28.7 + 28.7
t-CO2 eq 81.4 79.3
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

23
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 52 54
Combination Unit ARUN520LTH5 ARUN540LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

RT 41.4 42.9
*Cooling (Rated) kW 145.6 151.2
Btu/h 496,800 515,900
RT 36.5 37.0
Capacity **Cooling (Rated) kW 128.6 130.2
Btu/h 438,800 444,200
RT 46.3 48.1
Heating (Rated) kW 163.0 169.3
Btu/h 556,200 577,700
*Cooling (Rated) kW 34.60 36.44
Input **Cooling (Rated) kW 42.07 43.02
Heating (Rated) kW 38.24 40.26
*Cooling kW/kW 4.21 4.15
EER
**Cooling kW/kW 3.06 3.03
COP Heating kW/kW 4.26 4.21
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 4 62.1 × 4
Number of Revolution rev/min 3,600 × 4 3,600 × 4
Compressor
Motor Output x Number W x No. 5,300 × 4 5,300 × 4
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 6 900 × 6
m3/min 320 × 3 320 × 3
Air Flow Rate(High)
Fan ft3/min 11,301 × 3 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 3 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 3 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg (281 × 1) + (221 × 2) (281 × 1) + (221 × 2)
Net Weight
lbs (619 × 1) + (487 × 2) (619 × 1) + (487 × 2)
Sound Cooling dB(A) 65.8 67.0
Pressure Level Heating dB(A) 67.5 68.0
Sound Power Cooling dB(A) 89.0 89.0
Level Heating dB(A) 90.5 91.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

24
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 52 54
Combination Unit ARUN520LTH5 ARUN540LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN160LTH5 ARUN160LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 13.0 + 13.0 14.0 + 13.0 + 13.0
Precharged Amount
Refigerant lbs 30.9 + 28.7 + 28.7 30.9 + 28.7 + 28.7
t-CO2 eq 83.5 83.5
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

25
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 56 58
Combination Unit ARUN560LTH5 ARUN580LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN200LTH5 ARUN200LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

RT 44.5 46.1
*Cooling (Rated) kW 156.8 162.4
Btu/h 535,000 554,100
RT 38.7 39.2
Capacity **Cooling (Rated) kW 136.3 137.9
Btu/h 465,100 470,500
RT 50.0 51.8
Heating (Rated) kW 176.0 182.3
Btu/h 600,500 622,000
*Cooling (Rated) kW 36.80 38.64
Input **Cooling (Rated) kW 44.69 45.64
Heating (Rated) kW 42.40 44.42
*Cooling kW/kW 4.26 4.20
EER
**Cooling kW/kW 3.05 3.02
COP Heating kW/kW 4.15 4.10
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 5 62.1 × 5
Number of Revolution rev/min 3,600 × 5 3,600 × 5
Compressor
Motor Output x Number W x No. 5,300 × 5 5,300 × 5
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 6 900 × 6
m3/min 320 × 3 320 × 3
Air Flow Rate(High)
Fan ft3/min 11,301 × 3 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 19.05(3/4)
Connctions Gas mm(inch) 41.3(1-5/8) 41.3(1-5/8)
mm (1,240 ×1,690 × 760) × 3 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 3 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg (281 × 2) + (221 × 1) (281 × 2) + (221 × 1)
Net Weight
lbs (619 × 2) + (487 × 1) (619 × 2) + (487 × 1)
Sound Cooling dB(A) 66.3 67.4
Pressure Level Heating dB(A) 68.5 68.9
Sound Power Cooling dB(A) 90.0 90.0
Level Heating dB(A) 91.2 91.6
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

26
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 56 58
Combination Unit ARUN560LTH5 ARUN580LTH5
ARUN200LTH5 ARUN220LTH5
Model Name ARUN200LTH5 ARUN200LTH5
Independent Unit
ARUN160LTH5 ARUN160LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 14.0 + 13.0 14.0 + 14.0 + 13.0
Precharged Amount
Refigerant lbs 30.9 + 30.9 + 28.7 30.9 + 30.9 + 28.7
t-CO2 eq 85.6 85.6
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

27
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 60 62
Combination Unit ARUN600LTH5 ARUN620LTH5
ARUN220LTH5 ARUN220LTH5
Model Name ARUN220LTH5 ARUN200LTH5
Independent Unit
ARUN160LTH5 ARUN200LTH5

RT 47.7 49.3
*Cooling (Rated) kW 168.0 173.6
Btu/h 573,200 592,300
RT 39.6 41.4
Capacity **Cooling (Rated) kW 139.5 145.6
Btu/h 476,000 496,800
RT 53.6 55.5
Heating (Rated) kW 188.6 195.3
Btu/h 643,500 666,400
*Cooling (Rated) kW 40.48 40.84
Input **Cooling (Rated) kW 46.59 48.26
Heating (Rated) kW 46.44 48.58
*Cooling kW/kW 4.15 4.25
EER
**Cooling kW/kW 2.99 3.02
COP Heating kW/kW 4.06 4.02
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 5 62.1 × 6
Number of Revolution rev/min 3,600 × 5 3,600 × 6
Compressor
Motor Output x Number W x No. 5,300 × 5 5,300 × 6
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 6 900 × 6
m3/min 320 × 3 320 × 3
Air Flow Rate(High)
Fan ft3/min 11,301 × 3 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 19.05(3/4) 22.2(7/8)
Connctions Gas mm(inch) 41.3(1-5/8) 44.5(1-3/4)
mm (1,240 ×1,690 × 760) × 3 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 3 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg (281 × 2) + (221 × 1) 281 × 3
Net Weight
lbs (619 × 2) + (487 × 1) 619 × 3
Sound Cooling dB(A) 68.3 67.8
Pressure Level Heating dB(A) 69.3 69.6
Sound Power Cooling dB(A) 90.0 90.8
Level Heating dB(A) 92.0 92.1
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

28
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 60 62
Combination Unit ARUN600LTH5 ARUN620LTH5
ARUN220LTH5 ARUN220LTH5
Model Name ARUN220LTH5 ARUN200LTH5
Independent Unit
ARUN160LTH5 ARUN200LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 14.0 + 13.0 14.0 + 14.0 + 14.0
Precharged Amount
Refigerant lbs 30.9 + 30.9 + 28.7 30.9 + 30.9 + 30.9
t-CO2 eq 85.6 87.7
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

29
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 64 66
Combination Unit ARUN640LTH5 ARUN660LTH5
ARUN220LTH5 ARUN220LTH5
Model Name ARUN220LTH5 ARUN220LTH5
Independent Unit
ARUN200LTH5 ARUN220LTH5

RT 50.9 52.5
*Cooling (Rated) kW 179.2 184.8
Btu/h 611,400 630,500
RT 41.8 42.3
Capacity **Cooling (Rated) kW 147.2 148.8
Btu/h 502,200 507,700
RT 57.3 59.0
Heating (Rated) kW 201.6 207.9
Btu/h 687,900 709,400
*Cooling (Rated) kW 42.68 44.52
Input **Cooling (Rated) kW 49.21 50.16
Heating (Rated) kW 50.60 52.62
*Cooling kW/kW 4.20 4.15
EER
**Cooling kW/kW 2.99 2.97
COP Heating kW/kW 3.98 3.95
Power Factor - 0.93 0.93
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL code NL503K / NA507K NL503K / NA507K
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 62.1 × 6 62.1 × 6
Number of Revolution rev/min 3,600 × 6 3,600 × 6
Compressor
Motor Output x Number W x No. 5,300 × 6 5,300 × 6
Starting Method Direct On Line Direct On Line
Oil Type FVC68D(PVE) FVC68D(PVE)
Type Propeller fan Propeller fan
Motor Output x Number W 900 × 6 900 × 6
m3/min 320 × 3 320 × 3
Air Flow Rate(High)
Fan ft3/min 11,301 × 3 11,301 × 3
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid mm(inch) 22.2(7/8) 22.2(7/8)
Connctions Gas mm(inch) 44.5(1-3/4) 53.98(2-1/8)
mm (1,240 ×1,690 × 760) × 3 (1,240 ×1,690 × 760) × 3
Dimensions(W x H x D)
inch (48-13/16 × 66-17/32 × 29-29/32) × 3 (48-13/16 × 66-17/32 × 29-29/32) × 3
kg 281 × 3 281 × 3
Net Weight
lbs 619 × 3 619 × 3
Sound Cooling dB(A) 68.6 69.3
Pressure Level Heating dB(A) 70.0 70.3
Sound Power Cooling dB(A) 90.8 90.8
Level Heating dB(A) 92.5 92.8
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

30
Multi V 5 Tropical Outdoor Units

1. Specifications
HP 64 66
Combination Unit ARUN640LTH5 ARUN660LTH5
ARUN220LTH5 ARUN220LTH5
Model Name ARUN220LTH5 ARUN220LTH5
Independent Unit
ARUN200LTH5 ARUN220LTH5

High pressure protection High pressure sensor / High pressure switch


Protection Compressor/Fan Over-heat protection / Fan driver overload protector
Devices
Inverter Over-heat protection / Over-current protection
Communication Cable (VCTF-SB) No.×༅ 2C × 1.0 ~ 1.5 2C × 1.0 ~ 1.5
Refigerant name R410A R410A
kg 14.0 + 14.0 + 14.0 14.0 + 14.0 + 14.0
Precharged Amount
Refigerant lbs 30.9 + 30.9 + 30.9 30.9 + 30.9 + 30.9
t-CO2 eq 87.7 87.7
Control Electronic Expansion Valve Electronic Expansion Valve
380~415, 3, 50 380~415, 3, 50
Power Supply V, Ø, Hz
400, 3, 60 400, 3, 60
Number of maximum connectable indoor units 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions (ISO15042) :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• **Cooling : Indoor Ambient Temp. 29°CDB / 19°CWB, Outdoor Ambient Temp. 46°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The Maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)

31
32
Gravity point
Multi V 5 Tropical
2. Dimensions
ARUN080LTH5 / ARUN100LTH5 / ARUN120LTH5

[mm(inch)]
System Heat Recovery Heat Pump
Liquid Low Pressure High Pressure Liquid Gas
HP
pipe Gas pipe Gas pipe pipe pipe

8 Ø 9.52 (3/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 9.52 (3/8) Ø 19.05 (3/4)
10 Ø 9.52 (3/8) Ø 22.2 (7/8) Ø 19.05 (3/4) Ø 9.52 (3/8) Ø 22.2 (7/8)

12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
Outdoor Units
GGGGn™ˆ› G—–•›
Multi V 5 Tropical
2. Dimensions

[mm(inch)]
System Heat Recovery Heat Pump
Liquid Low Pressure High Pressure Liquid Gas
HP
pipe Gas pipe Gas pipe pipe pipe

14~16 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
18~20 Ø 15.88 (5/8) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)

22 Ø 15.88 (5/8) Ø 28.58(1-1/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)


24 Ø 15.88 (5/8) Ø 34.9(1-3/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 34.9 (1-3/8)

26~34 Ø 19.05 (3/4) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 34.9 (1-3/8)

36~40 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)

42~60 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 34.9 (1-3/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)

62~64 Ø 22.2 (7/8) Ø 44.5 (1-3/4) Ø 41.3 (1-5/8) Ø 22.2 (7/8) Ø 44.5 (1-3/4)

66~96 Ø 22.2 (7/8) Ø 53.98 (2-1/8) Ø 44.5 (1-3/4) Ø 22.2 (7/8) Ø 53.98 (2-1/8)
ARUN140LTH5 / ARUN160LTH5 / ARUN180LTH5 / ARUN200LTH5 / ARUN220LTH5
Outdoor Units

33
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
3.1 8 / 10 HP (1 Comp)
̰ Cooling Operation

High Temperature High Pressure Gas


High Temperature High Pressure Liquid
Low Temperature Low Pressure Gas

Indoor Heat Exchanger Indoor Unit Indoor Heat Exchanger Indoor Unit
Electronic Electronic
Expansion Valve Expansion Valve

M M
Fan Fan

Outdoor Unit
Fan
Outdoor 4-Way
Temperature Motor Valve
Sensor

High Pressure Pressure Gas Pipe


Sensor Switch
Liquid Pipe
Outdoor
Unit HEX
Temperature
Sensor

Suction Oil Separator


Temperature
Sensor

Charging Port

Comp.1 Discharge
Accumulator Temperature Sensor
Low Pressure Sensor

Inverter
Comp.1

Sub-Cooling Circuit
Outlet Temperature
Sensor

Liquid Pipe
Heatsink Temperature Sensor
SC EEV

Pressure Sensor Temperature Sensor Check Valve s Solenoid Valve


Remarks
Pressure Switch SVC Valve EEV Strainer

34
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
̰ Oil Return/ Defrost Operation

High Temperature High Pressure Gas


High Temperature High Pressure Liquid
Low Temperature Low Pressure Gas

Indoor Heat Exchanger Indoor Unit Indoor Heat Exchanger Indoor Unit
Electronic Electronic
Expansion Valve Expansion Valve

M M
Fan Fan

Outdoor Unit
Fan
Outdoor 4-Way
Temperature Motor Valve
Sensor

High Pressure Pressure Gas Pipe


Sensor Switch
Liquid Pipe
Outdoor
Unit HEX
Temperature
Sensor

Suction Oil Separator


Temperature
Sensor

Charging Port

Comp.1 Discharge
Accumulator Temperature Sensor
Low Pressure Sensor

Inverter
Comp.1

Sub-Cooling Circuit
Outlet Temperature
Sensor

Liquid Pipe
Heatsink Temperature Sensor
SC EEV

Pressure Sensor Temperature Sensor Check Valve s Solenoid Valve


Remarks
Pressure Switch SVC Valve EEV Strainer

36
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
3.2 12 / 14 / 16 HP (1 Comp)
̰ Cooling Operation

High Temperature High Pressure Gas


High Temperature High Pressure Liquid
Low Temperature Low Pressure Gas

Indoor Heat Exchanger p•‹––™G|•› Indoor Heat Exchanger p•‹––™G|•›


Electronic Electronic
Expansion Valve Expansion Valve

M M
Fan Fan

Outdoor Unit
Q
Fan
Outdoor 4-Way
Temperature M M Motor Valve
Sensor

High Pressure Pressure nˆšGw—ŒG


Gas Pipe
Sensor Switch
Low Pressure Sensor
s˜œ‹Gw—ŒG
Liquid Pipe
Outdoor
Unit HEX
Temperature
Sensor

Suction Oil Separator


Temperature
Sensor

Receiver
Receiver Outlet

Accumulator Comp.1 Discharge


Temperature Sensor

Charging Port
Receiver
Inlet SC Inverter
Suction Comp.1
Oil Return
Sub-Cooling Circuit
Outlet Temperature VI EEV
Sensor

Sub-Cooling Circuit Liquid Pipe


Heatsink Inlet Temperature Temperature Sensor
Sensor SC EEV

* 14, 16HP have 2fans.

Pressure Sensor Temperature Sensor Check Valve š Solenoid Valve


Remarks
Pressure Switch SVC Valve EEV Strainer

37
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
̰ Oil Return/ Defrost Operation

High Temperature High Pressure Gas


High Temperature High Pressure Liquid
Low Temperature Low Pressure Gas

Indoor Heat Exchanger p•‹––™G|•› Indoor Heat Exchanger p•‹––™G|•›


Electronic Electronic
Expansion Valve Expansion Valve

M M
Fan Fan

Outdoor Unit
Q
Fan
Outdoor 4-Way
Temperature Motor Valve
Sensor

High Pressure Pressure nˆšGw—ŒG


Gas Pipe
Sensor Switch
Low Pressure Sensor s˜œ‹Gw—ŒG
Liquid Pipe

Outdoor
Unit HEX
Temperature
Sensor

Suction Temperature Oil Separator


Sensor

Receiver
Receiver Outlet

Accumulator Comp.1 Discharge


Temperature Sensor

Charging Port

Receiver Inlet
SC Inverter
Suction Comp.1
Oil Return
Sub-Cooling
Circuit Outlet VI EEV
Temperature Sensor

Sub-Cooling Liquid Pipe


Heatsink Circuit Inlet Temperature Sensor
Temperature Sensor SC EEV

* 14, 16HP have 2fans.

Pressure Sensor Temperature Sensor Check Valve š Solenoid Valve


Remarks
Pressure Switch SVC Valve EEV Strainer

39
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
3.3 18 / 20 / 22 HP (2 Comp)
̰ Cooling Operation

oŽG{Œ”—Œ™ˆ›œ™ŒGoŽGw™Œššœ™ŒGnˆš
oŽG{Œ”—Œ™ˆ›œ™ŒGoŽGw™Œššœ™ŒGs˜œ‹
s–žG{Œ”—Œ™ˆ›œ™ŒGs–žGw™Œššœ™ŒGnˆš

p•‹––™G oŒˆ›GlŸŠˆ•ŽŒ™ p•‹––™G|•› p•‹––™G oŒˆ›GlŸŠˆ•ŽŒ™ p•‹––™G|•›


l“ŒŠ›™–•ŠG l“ŒŠ›™–•ŠG
lŸ—ˆ•š–•G}ˆ“Œ lŸ—ˆ•š–•G}ˆ“Œ

t t
mˆ• mˆ•

vœ›‹––™G|•›
mˆ•
vœ›‹––™ [T~ˆ
{Œ”—Œ™ˆ›œ™Œ t–›–™ }ˆ“Œ
zŒ•š–™

oŽGw™Œššœ™Œ w™Œššœ™Œ nˆšGw—ŒG


zŒ•š–™ zž›Š
s–žGw™Œššœ™ŒGzŒ•š–™ s˜œ‹Gw—ŒG

vœ›‹––™
|•›Gol
{Œ”—Œ™ˆ›œ™Œ
zŒ•š–™

zœŠ›–• j–”—UX v“


{Œ”—Œ™ˆ›œ™Œ kšŠˆ™ŽŒ v“GzŒ—ˆ™ˆ›–™
zŒ—ˆ™ˆ›–™
zŒ•š–™ {Œ”—Œ™ˆ›œ™Œ
zŒ•š–™ j–”—UYGkšŠˆ™ŽŒ
yŒŠŒŒ™ {Œ”—Œ™ˆ›œ™ŒGzŒ•š–™
yŒŠŒŒ™
vœ›“Œ›
v“Giˆ“ˆ•ŠŒ v“Giˆ“ˆ•ŠŒ
hŠŠœ”œ“ˆ›–™ p•Œ™›Œ™ }ˆ“Œ p•Œ™›Œ™ }ˆ“Œ
j–”—UX j–”—UY
jˆ™ŽT
•ŽG
w–™› }pGll} }pGll}
yŒŠŒŒ™ zj
p•“Œ› zœŠ›–•
v“GyŒ›œ™•
zœ‰Tj––“•Ž
j™Šœ›Gvœ›“Œ›
{Œ”—Œ™ˆ›œ™ŒGzŒ•š–™

zœ‰Tj––“•Ž s˜œ‹Gw—Œ
oŒˆ›š•’ j™Šœ›Gp•“Œ› {Œ”—Œ™ˆ›œ™ŒGzŒ•š–™
{Œ”—Œ™ˆ›œ™ŒGzŒ•š–™ zjGll}

w™Œššœ™ŒGzŒ•š–™ {Œ”—Œ™ˆ›œ™ŒGzŒ•š–™ jŒŠ’G}ˆ“Œ š z–“Œ•–‹G}ˆ“Œ


yŒ”ˆ™’š
w™Œššœ™ŒGzž›Š z}jG}ˆ“Œ ll} z›™ˆ•Œ™

40
Multi V 5 Tropical Outdoor Units

3. Piping Diagrams
̰ Oil Return/ Defrost Operation

oŽG{Œ”—Œ™ˆ›œ™ŒGoŽGw™Œššœ™ŒGnˆš
oŽG{Œ”—Œ™ˆ›œ™ŒGoŽGw™Œššœ™ŒGs˜œ‹
s–žG{Œ”—Œ™ˆ›œ™ŒGs–žGw™Œššœ™ŒGnˆš

p•‹––™G oŒˆ›GlŸŠˆ•ŽŒ™ p•‹––™G|•› p•‹––™G oŒˆ›GlŸŠˆ•ŽŒ™ p•‹––™G|•›


l“ŒŠ›™–•ŠG l“ŒŠ›™–•ŠG
lŸ—ˆ•š–•G}ˆ“Œ lŸ—ˆ•š–•G}ˆ“Œ

t t
mˆ• mˆ•

vœ›‹––™G|•›
mˆ•
vœ›‹––™ [T~ˆ
{Œ”—Œ™ˆ›œ™Œ t–›–™ }ˆ“Œ
zŒ•š–™

oŽGw™Œššœ™Œ w™Œššœ™Œ nˆšGw—ŒG


zŒ•š–™ zž›Š
s–žGw™Œššœ™ŒGzŒ•š–™ s˜œ‹Gw—ŒG

vœ›‹––™
|•›Gol
{Œ”—Œ™ˆ›œ™Œ
zŒ•š–™

zœŠ›–• j–”—UX v“ v“


zŒ—ˆ™ˆ›–™ j–”—UY zŒ—ˆ™ˆ›–™
{Œ”—Œ™ˆ›œ™Œ kšŠˆ™ŽŒ kšŠˆ™ŽŒ
zŒ•š–™ {Œ”—Œ™ˆ›œ™Œ {Œ”—Œ™ˆ›œ™Œ
zŒ•š–™ zŒ•š–™
yŒŠŒŒ™
yŒŠŒŒ™
vœ›“Œ›
v“Giˆ“ˆ•ŠŒ v“Giˆ“ˆ•ŠŒ
p•Œ™›Œ™ }ˆ“Œ p•Œ™›Œ™ }ˆ“Œ
hŠŠœ”œ“ˆ›–™ j–”—UX j–”—UY
jˆ™ŽT
•ŽG
w–™› }pGll} }pGll}
yŒŠŒŒ™
p•“Œ› zj
zœŠ›–•
v“GyŒ›œ™•
zœ‰Tj––“•Ž
j™Šœ›Gvœ›“Œ›
{Œ”—Œ™ˆ›œ™ŒGzŒ•š–™

zœ‰Tj––“•Ž s˜œ‹Gw—Œ
oŒˆ›š•’ j™Šœ›Gp•“Œ› {Œ”—Œ™ˆ›œ™ŒGzŒ•š–™
{Œ”—Œ™ˆ›œ™ŒGzŒ•š–™ zjGll}

w™Œššœ™ŒGzŒ•š–™ {Œ”—Œ™ˆ›œ™ŒGzŒ•š–™ jŒŠ’G}ˆ“Œ š z–“Œ•–‹G}ˆ“Œ


yŒ”ˆ™’š
w™Œššœ™ŒGzž›Š z}jG}ˆ“Œ ll} z›™ˆ•Œ™

42
Multi V 5 Tropical Outdoor Units

4. Wiring Diagrams
4.1 8 / 10 HP (UXA, 1 Comp)

43
Multi V 5 Tropical Outdoor Units

4. Wiring Diagrams
4.2 12 HP (UXA, 1 Comp)

44
Multi V 5 Tropical Outdoor Units

4. Wiring Diagrams
4.3 14 / 16 HP (UXB, 1 Comp)

45
Multi V 5 Tropical Outdoor Units

4. Wiring Diagrams
4.4 18 / 20 / 22 HP (UXB, 2 Comp)

46
Multi V 5 Tropical Outdoor Units

5. Field Wiring
5.1 Heat Pump System
̰ Example Connection of Power & Communication Cable
 Single Outdoor Unit
Outdoor Voltage range(V)
Power supply Frequency
Outdoor Indoor
(3Ø 4wires)
[Outdoor Unit] 60Hz 400 220
(Main Switch)
R S T N 50Hz 380-415 220-240
Switch

Fuse
Indoor
Power supply
(1Ø 2wires)
L N
Power Line
(4 Wires Cable)
Fuse Power Line
(2 Wires Cable)
Communication Line
(2 Wires Cable)

Pull Box Pull Box Pull Box


(Installer option) (Installer option) (Installer option)

Power Line Power Line Power Line Power Line


(2 Wires Cable) (2 Wires Cable) (2 Wires Cable) (2 Wires Cable)

Communication Line
(3 Wires Cable)
[Indoor Units]

WARNING
• Indoor Unit ground Lines are required for preventing electrical shock accident during current leakage,
Communication disorder by noise effect and motor current leakage (without connection to pipe).
• Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from
the power supply.
If individual power supply is necessary for each indoor unit, IPM (Independent Power Module) should
be applied at each indoor unit. (optional)
• Install the main switch that can interrupt all the power sources in an integrated manner because this
system consists of the equipment utilizing the multiple power sources.
• If there exists the possibility of reversed phase, lose phase, momentary blackout or the power goes on
and off while the product is operating, attach a reversed phase protection circuit locally.
Running the product in reversed phase may break the compressor and other parts.

Between Indoor and Master Outdoor unit

Master
SODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY2 GND 12V
Outdoor Unit

3 4 3 4 3 4

The GND terminal at the main PCB is a ‘-’ terminal for day contact, it is
not the point to make ground connection.

47
Multi V 5 Tropical Outdoor Units

5. Field Wiring
̰ Series Outdoor Unit
 When the power source is connected In series between the units.
Outdoor ※ The below System is representative Multi V 5 System.
Power supply Actual combination of outdoor unit may be different by product line-up of region.
(3Ø 4wires)
(Main Switch) [Master] [Slave1] [Slave2] [Slave3]
R S T N

Switch

Fuse
Indoor
Power supply
(1Ø 2wires)
L N
Power Line
(4 Wires Cable)
Fuse Power Line
(2 Wires Cable)
Communication Line
(2 Wires Cable)

Pull Box Pull Box Pull Box


(Installer option) (Installer option) (Installer option)

Power Line Power Line Power Line Power Line Voltage range(V)
(2 Wires Cable) (2 Wires Cable) (2 Wires Cable) (2 Wires Cable) Frequency
Outdoor Indoor
60Hz 400 220

Communication Line 50Hz 380-415 220-240


(3 Wires Cable)

[Indoor Units]

WARNING
When the MCA (sum of the maximum current) is over than 150A, do not use single power source for
connecting seriesunits.

 When the power source is supplied to Each outdoor unit individually.


Outdoor
※ The below System is representative Multi V 5 System.
Power supply
Actual combination of outdoor unit may be different by product line-up of region.
(3Ø 4wires)
(Main Switch) [Master] [Slave1] [Slave2] [Slave3]
R S T N R S T N R S T N R S T N

Switch Switch Switch Switch

Fuse Fuse Fuse Fuse


Indoor
Power supply
(1Ø 2wires)
L N

Fuse Power Line


(2 Wires Cable)
Power Line Communication Line
(4 Wires Cable) (2 Wires Cable)

Pull Box Pull Box Pull Box


(Installer option) (Installer option) (Installer option)

Power Line Power Line Power Line Power Line


Voltage range(V) (2 Wires Cable) (2 Wires Cable) (2 Wires Cable) (2 Wires Cable)
Frequency
Outdoor Indoor
60Hz 400 220
Communication Line
50Hz 380-415 220-240 (3 Wires Cable)

[Indoor Units]

48
Multi V 5 Tropical Outdoor Units

5. Field Wiring

WARNING
• Indoor Unit ground Lines are required for preventing electrical shock accident during current leakage,
Communication disorder by noise effect and motor current leakage (without connection to pipe).
• Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from
the power supply.
If individual power supply is necessary for each indoor unit, IPM (Independent Power Module) should
be applied at each indoor unit. (optional)
• Install the main switch that can interrupt all the power sources in an integrated manner because this
system consists of the equipment utilizing the multiple power sources.
• If there exists the possibility of reversed phase, lose phase, momentary blackout or the power goes on
and off while the product is operating, attach a reversed phase protection circuit locally.
Running the product in reversed phase may break the compressor and other parts.

 Between Indoor and Master Outdoor unit

Master Master
SODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY2 GND 12V SODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY2 GND 12V
Outdoor Unit Outdoor unit

3 4 3 4 3 4 SODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY2 GND 12V
Slave1
Outdoor Unit

Slave2
SODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY2 GND 12V
Outdoor Unit

The GND terminal at the main PCB is a ‘-’ terminal for dry contact. It is not the point to make ground connection.
• Make sure that terminal number of master and slave outdoor units are matched.(A-A,B-B)

̰ Example Connection of Communication Cable

• Connection of communication cable must be installed • Abnormal operation can be caused by communication
like below figure between indoor unit to outdoor unit. defect, when connection of communication cable is in
stalled like below figure.
BUS Type STAR Type

49
Multi V 5 Tropical Outdoor Units

6. Electric Characteristics
̰ Wiring of Main Power Supply and Equipment Capacity
1. Use a separate power supply for the Outdoor Unit and Indoor Unit.
2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain liquid,etc.) when proceeding with the
wiring and connections
3. The wire size is the minimum value for metal conduit wiring. The power cord size should be 1 rank thicker taking
into account the line voltage drops. Make sure the power-supply voltage does not drop more than 10%.
4. Specific wiring requirements should adhere to the wiring regulations of the region.
5. Power supply cords of parts of appliances for outdoor use should not be lighter than polychloroprene sheathed
flexible cord (design 60245 IEC57).
6. Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from the power
supply.

WARNING
• Follow ordinance of local regulation for technical standard related to electrical equipment, wiring
regulations and guidance of each electric power company.
• Make sure to use specified wires for connections so that no external force is imparted to terminal
connections. If connections are not fixed firmly, it may cause heating or fire.
• Make sure to use the appropriate type of overcurrent protection switch. Note that generated overcurrent
may include some amount of direct current.
• Some installation site may require attachment of an earth leakage breaker. If no earth leakage breaker
is installed, it may cause an electric shock.

CAUTION
• Do not use anything other than breaker and fuse with correct capacity. Using fuse and wire or copper
wire with too large capacity may cause a malfunction of unit or fire.

50
Multi V 5 Tropical Outdoor Units

6. Electric Characteristics
̰ 50Hz
Unit Power Supply COMP OFM
Model
Hz Volts Voltage-range MCA TOCA MFA MSC RLA(Cooling) RLA(Heating) kW FLA
8 HP 50 380-415 Min.:342, Max.:456 24.1 26.0 25 5.9 5.7 7.0 1.20 2.50
10 HP 50 380-415 Min.:342, Max.:456 25.9 28.0 30 5.9 8.9 9.4 1.20 2.50
12 HP 50 380-415 Min.:342, Max.:456 28.0 30.0 30 5.9 10.6 10.7 1.20 2.50
14 HP 50 380-415 Min.:342, Max.:456 30.2 32.0 32 5.9 12.4 13.3 1.80 2.50
16 HP 50 380-415 Min.:342, Max.:456 30.2 32.0 32 5.9 15.1 16.1 1.80 2.50
18 HP 50 380-415 Min.:342, Max.:456 40.7 44.0 45 10.2 15.8 17.1 1.80 2.50
20 HP 50 380-415 Min.:342, Max.:456 46.3 50.0 55 10.2 17.9 22.9 1.80 2.50
22 HP 50 380-415 Min.:342, Max.:456 47.3 52.0 55 10.2 21.7 26.2 1.80 2.50
24 HP 50 380-415 Min.:342, Max.:456 56.1 60.0 60 11.8 21.1 21.3 2.40 5.00
26 HP 50 380-415 Min.:342, Max.:456 58.2 62.0 63 11.8 22.9 24.0 3.00 5.00
28 HP 50 380-415 Min.:342, Max.:456 58.2 62.0 63 11.8 25.7 26.7 3.00 5.00
30 HP 50 380-415 Min.:342, Max.:456 60.4 64.0 75 11.8 27.5 29.4 3.60 5.00
32 HP 50 380-415 Min.:342, Max.:456 60.4 64.0 75 11.8 30.3 32.1 3.60 5.00
34 HP 50 380-415 Min.:342, Max.:456 70.9 76.0 80 16.1 30.9 33.1 3.60 5.00
36 HP 50 380-415 Min.:342, Max.:456 76.5 82.0 90 16.1 33.1 38.9 3.60 5.00
38 HP 50 380-415 Min.:342, Max.:456 77.5 84.0 90 16.1 36.9 42.2 3.60 5.00
40 HP 50 380-415 Min.:342, Max.:456 92.6 100.0 105 20.4 35.8 45.7 3.60 5.00
42 HP 50 380-415 Min.:342, Max.:456 93.6 104.0 105 20.4 39.7 49.0 3.60 5.00
44 HP 50 380-415 Min.:342, Max.:456 94.5 105.0 105 20.4 43.5 52.3 3.60 5.00
46 HP 50 380-415 Min.:342, Max.:456 90.6 96.0 105 17.7 42.6 45.4 5.40 7.50
48 HP 50 380-415 Min.:342, Max.:456 90.6 96.0 105 17.7 45.4 48.2 5.40 7.50
50 HP 50 380-415 Min.:342, Max.:456 101.1 105.0 105 22.0 46.1 49.2 5.40 7.50
52 HP 50 380-415 Min.:342, Max.:456 106.7 114.0 120 22.0 48.2 55.0 5.40 7.50
54 HP 50 380-415 Min.:342, Max.:456 107.7 116.0 120 22.0 52.0 58.3 5.40 7.50
56 HP 50 380-415 Min.:342, Max.:456 122.8 132.0 135 26.3 51.0 61.8 5.40 7.50
58 HP 50 380-415 Min.:342, Max.:456 123.8 132.0 135 26.3 54.8 65.1 5.40 7.50
60 HP 50 380-415 Min.:342, Max.:456 124.7 137.0 150 26.3 58.6 68.4 5.40 7.50
62 HP 50 380-415 Min.:342, Max.:456 139.9 145.0 150 30.6 57.6 71.9 5.40 7.50
64 HP 50 380-415 Min.:342, Max.:456 140.8 147.0 150 30.6 61.4 75.2 5.40 7.50
66 HP 50 380-415 Min.:342, Max.:456 141.8 150.0 150 30.6 65.2 78.5 5.40 7.50

Note
1. Voltage supplied to the unit terminals should be within the minimum and maximum
range. Symbols
MCA : Minimum Circuit Amperes (A)
2. Maximum allowable voltage unbalance between phase is 2%.
3. MSC means the Max. current during the starting of compressor. TOCA : Total Over Current Amperes (A)
4. MSC and RLA are measured as the compressor only test condition. MFA : Maximum Fuse Amperes (A)
5. OFM are measured as the outdoor unit test condition. MSC : Maximum Starting Current (A)
6. TOCA means the total over current value of each outdoor unit. RLA : Rated Load Amperes (A)
7. Select the wire size based on the larger value among MCA or TOCA. OFM : Outdoor Fan Motor
8. MFA is used to select the circuit breaker and ground fault circuit interrupter, and kW : Fan Motor rated output (kW)
recommended circuit breaker type is ELCB(Earth Leakage Circuit Breaker).
FLA : Full Load Amperes (A)
9. Select the electrical equipment of combination unit according to the electrical
characteristics of individual unit.

51
Multi V 5 Tropical Outdoor Units

6. Electric Characteristics
̰ 60Hz
Unit Power Supply COMP OFM
Model
Hz Volts Voltage-range MCA TOCA MFA MSC RLA(Cooling) RLA(Heating) kW FLA
8 HP 60 400 Min.:342, Max.:440 24.1 26.0 25 5.9 5.7 7.0 1.20 2.50
10 HP 60 400 Min.:342, Max.:440 25.9 28.0 30 5.9 8.9 9.4 1.20 2.50
12 HP 60 400 Min.:342, Max.:440 28.0 30.0 30 5.9 10.6 10.7 1.20 2.50
14 HP 60 400 Min.:342, Max.:440 30.2 32.0 32 5.9 12.4 13.3 1.80 2.50
16 HP 60 400 Min.:342, Max.:440 30.2 32.0 32 5.9 15.1 16.1 1.80 2.50
18 HP 60 400 Min.:342, Max.:440 40.7 44.0 45 10.2 15.8 17.1 1.80 2.50
20 HP 60 400 Min.:342, Max.:440 46.3 50.0 55 10.2 17.9 22.9 1.80 2.50
22 HP 60 400 Min.:342, Max.:440 47.3 52.0 55 10.2 21.7 26.2 1.80 2.50
24 HP 60 400 Min.:342, Max.:440 56.1 60.0 60 11.8 21.1 21.3 2.40 5.00
26 HP 60 400 Min.:342, Max.:440 58.2 62.0 63 11.8 22.9 24.0 3.00 5.00
28 HP 60 400 Min.:342, Max.:440 58.2 62.0 63 11.8 25.7 26.7 3.00 5.00
30 HP 60 400 Min.:342, Max.:440 60.4 64.0 75 11.8 27.5 29.4 3.60 5.00
32 HP 60 400 Min.:342, Max.:440 60.4 64.0 75 11.8 30.3 32.1 3.60 5.00
34 HP 60 400 Min.:342, Max.:440 70.9 76.0 80 16.1 30.9 33.1 3.60 5.00
36 HP 60 400 Min.:342, Max.:440 76.5 82.0 90 16.1 33.1 38.9 3.60 5.00
38 HP 60 400 Min.:342, Max.:440 77.5 84.0 90 16.1 36.9 42.2 3.60 5.00
40 HP 60 400 Min.:342, Max.:440 92.6 100.0 105 20.4 35.8 45.7 3.60 5.00
42 HP 60 400 Min.:342, Max.:440 93.6 104.0 105 20.4 39.7 49.0 3.60 5.00
44 HP 60 400 Min.:342, Max.:440 94.5 105.0 105 20.4 43.5 52.3 3.60 5.00
46 HP 60 400 Min.:342, Max.:440 90.6 96.0 105 17.7 42.6 45.4 5.40 7.50
48 HP 60 400 Min.:342, Max.:440 90.6 96.0 105 17.7 45.4 48.2 5.40 7.50
50 HP 60 400 Min.:342, Max.:440 101.1 105.0 105 22.0 46.1 49.2 5.40 7.50
52 HP 60 400 Min.:342, Max.:440 106.7 114.0 120 22.0 48.2 55.0 5.40 7.50
54 HP 60 400 Min.:342, Max.:440 107.7 116.0 120 22.0 52.0 58.3 5.40 7.50
56 HP 60 400 Min.:342, Max.:440 122.8 132.0 135 26.3 51.0 61.8 5.40 7.50
58 HP 60 400 Min.:342, Max.:440 123.8 132.0 135 26.3 54.8 65.1 5.40 7.50
60 HP 60 400 Min.:342, Max.:440 124.7 137.0 150 26.3 58.6 68.4 5.40 7.50
62 HP 60 400 Min.:342, Max.:440 139.9 145.0 150 30.6 57.6 71.9 5.40 7.50
64 HP 60 400 Min.:342, Max.:440 140.8 147.0 150 30.6 61.4 75.2 5.40 7.50
66 HP 60 400 Min.:342, Max.:440 141.8 150.0 150 30.6 65.2 78.5 5.40 7.50

Note
1. Voltage supplied to the unit terminals should be within the minimum and maximum
range. Symbols
MCA : Minimum Circuit Amperes (A)
2. Maximum allowable voltage unbalance between phase is 2%.
3. MSC means the Max. current during the starting of compressor. TOCA : Total Over Current Amperes (A)
4. MSC and RLA are measured as the compressor only test condition. MFA : Maximum Fuse Amperes (A)
5. OFM are measured as the outdoor unit test condition. MSC : Maximum Starting Current (A)
6. TOCA means the total over current value of each outdoor unit. RLA : Rated Load Amperes (A)
7. Select the wire size based on the larger value among MCA or TOCA. OFM : Outdoor Fan Motor
8. MFA is used to select the circuit breaker and ground fault circuit interrupter, and kW : Fan Motor rated output (kW)
recommended circuit breaker type is ELCB(Earth Leakage Circuit Breaker).
FLA : Full Load Amperes (A)
9. Select the electrical equipment of combination unit according to the electrical
characteristics of individual unit.

52
Multi V 5 Tropical Outdoor Units

9. Operation Limits
̰ Cooling / Heating Operation

Cooling Heating
60°C 20°C
18°C
55°C
15°C
50°C

Range for continuous operation


10°C

Range for warming up operation


45°C

Outdoor Temperature(°C WB)


40°C
5°C
Range for continuous operation
Outdoor Temperature(°C DB)

Range for pull down operation


35°C
0°C
30°C

25°C -5°C

20°C
-10°C
15°C

10°C -15°C

5°C
-20°C
0°C

-5°C
-25°C
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 27°C 30°C
Indoor Temperature(°C WB) Indoor Temperature(°C DB)

Note
1. These figures assume the following operating conditions:
Equivalent piping length:7.5m
Level difference:0m
2. Range of pull down operation:
If the relative humidity is too high, cooling capacity can be decreased by the sensible heat reduction.


Multi V 5 Tropical Outdoor Units

10. Sound Levels


10.1 Sound Pressure Level
Note
• Data is valid at free field condition
• Data is valid at nominal operating condition
• Sound level will vary depending on a range of
factors such as the construction(acoustic
1m
absorption coefficient) of particular room in
which the equipment is installed
1m
• Sound level can be increased in static
pressure mode or air guide application.

Unit:dB(A)
Model Cooling Heating
ARUN080LTH5 58.0 60.0
ARUN100LTH5 58.5 60.5
ARUN120LTH5 59.0 60.0
ARUN140LTH5 60.0 61.0
ARUN160LTH5 60.5 61.5
ARUN180LTH5 61.0 62.0
ARUN200LTH5 62.0 64.5
ARUN220LTH5 64.5 65.5
ARUN240LTH5 62.0 63.0
ARUN260LTH5 62.5 63.5
ARUN280LTH5 62.8 63.8
ARUN300LTH5 63.3 64.3
ARUN320LTH5 63.5 64.5
ARUN340LTH5 63.8 64.8
ARUN360LTH5 64.3 66.3
ARUN380LTH5 66.0 67.0
ARUN400LTH5 65.0 67.5
ARUN420LTH5 66.4 68.0
ARUN440LTH5 67.5 68.5
ARUN460LTH5 65.1 66.1
ARUN480LTH5 65.3 66.3
ARUN500LTH5 65.4 66.4
ARUN520LTH5 65.8 67.5
ARUN540LTH5 67.0 68.0
ARUN560LTH5 66.3 68.5
ARUN580LTH5 67.4 68.9
ARUN600LTH5 68.3 69.3
ARUN620LTH5 67.8 69.6
ARUN640LTH5 68.6 70.0
ARUN660LTH5 69.3 70.3

240
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN080LTH5 ARUN100LTH5 ARUN120LTH5
80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN140LTH5 ARUN160LTH5 ARUN180LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN200LTH5 ARUN220LTH5 ARUN240LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

241
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN260LTH5 ARUN280LTH5 ARUN300LTH5
80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN320LTH5 ARUN340LTH5 ARUN360LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


Octave Band Sound Pressure Level (dB = 20μPa )

65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN380LTH5 ARUN400LTH5 ARUN420LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

242
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN440LTH5 ARUN460LTH5 ARUN480LTH5
80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN500LTH5 ARUN520LTH5 ARUN540LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


Octave Band Sound Pressure Level (dB = 20μPa )

65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN560LTH5 ARUN580LTH5 ARUN600LTH5


80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

243
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN620LTH5 ARUN640LTH5 ARUN660LTH5
80 80 80
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating
75 75 75

70 70 70
Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )

Octave Band Sound Pressure Level (dB = 20μPa )


65 65 65
NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60
55 55 55
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50
45 45 45
NC-45 NC-45 NC-45
40 40 40
NC-40 NC-40 NC-40
35 35 35
NC-35 NC-35 NC-35
30 30 30
NC-30 NC-30 NC-30
25 25 25

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


Hearing NC-20 Hearing NC-20 Hearing NC-20
15 15 15

NC-15 NC-15 NC-15


10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

244
Multi V 5 Tropical Outdoor Units

10. Sound Levels


10.2 Sound Power Levels
Note
• Data is valid at diffuse field condition
• Data is valid at nominal operating condition
• Sound level can be increased in static pressure mode or used air guide.
• Sound power level is measured on the rated condition in the reverberation rooms.
• Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient)
of particular room in which the equipment in installed.
• Reference acoustic intensity 0dB = 10E-6μW/m2

Unit:dB(A)
Model Cooling Heating
ARUN080LTH5 78.0 80.0
ARUN100LTH5 79.0 80.0
ARUN120LTH5 79.0 80.0
ARUN140LTH5 82.0 84.0
ARUN160LTH5 83.0 85.0
ARUN180LTH5 85.0 86.0
ARUN200LTH5 86.0 87.0
ARUN220LTH5 86.0 88.0
ARUN240LTH5 82.0 83.0
ARUN260LTH5 83.8 85.5
ARUN280LTH5 84.5 86.2
ARUN300LTH5 85.5 87.5
ARUN320LTH5 86.0 88.0
ARUN340LTH5 87.1 88.5
ARUN360LTH5 87.8 89.1
ARUN380LTH5 87.8 89.8
ARUN400LTH5 89.0 90.0
ARUN420LTH5 89.0 90.5
ARUN440LTH5 89.0 91.0
ARUN460LTH5 87.5 89.5
ARUN480LTH5 87.8 89.8
ARUN500LTH5 88.5 90.1
ARUN520LTH5 89.0 90.5
ARUN540LTH5 89.0 91.0
ARUN560LTH5 90.0 91.2
ARUN580LTH5 90.0 91.6
ARUN600LTH5 90.0 92.0
ARUN620LTH5 90.8 92.1
ARUN640LTH5 90.8 92.5
ARUN660LTH5 90.8 92.8

245
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN080LTH5 ARUN100LTH5 ARUN120LTH5
100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN140LTH5 ARUN160LTH5 ARUN180LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN200LTH5 ARUN220LTH5 ARUN240LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

246
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN260LTH5 ARUN280LTH5 ARUN300LTH5
100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN320LTH5 ARUN340LTH5 ARUN360LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN380LTH5 ARUN400LTH5 ARUN420LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

247
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN440LTH5 ARUN460LTH5 ARUN480LTH5
100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN500LTH5 ARUN520LTH5 ARUN540LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARUN560LTH5 ARUN580LTH5 ARUN600LTH5


100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

248
Multi V 5 Tropical Outdoor Units

10. Sound Levels


ARUN620LTH5 ARUN640LTH5 ARUN660LTH5
100 100 100
̰ Cooling ̰ Cooling ̰ Cooling
̵ Heating ̵ Heating ̵ Heating

90 90 90

NR-90 NR-90 NR-90

80 80 80
NR-85 NR-85 NR-85
Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )

Sound Power Level (0dB = 10E-6μW/m 2 )


NR-80 NR-80 NR-80

70 NR-75 70 NR-75 70 NR-75

NR-70 NR-70 NR-70

60 60 60
NR-65 NR-65 NR-65

NR-60 NR-60 NR-60


50 50 50
NR-55 NR-55 NR-55

NR-50 NR-50 NR-50


40 40 40
NR-45 NR-45 NR-45

NR-40 NR-40 NR-40


30 30 30
NR-35 NR-35 NR-35

NR-30 NR-30 NR-30


20 20 20
NR-25 NR-25 NR-25

NR-20 NR-20 NR-20


10 10 10
125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

249
Air Solution
LG Electronics Inc, 128, Yeoui-daero,
Yeongdeungpo-gu, Seoul, Korea
(07336)
http://partner.lge.com