eGrout S50* constructive solutions

Non shrink electrochemically compatible grout

Uses Instructions for use

eGrout S50 is used to grout spaces between structural Preparation


concrete and cathodic protection anodes such as narrow
The substrate must be free from oil, grease or any loosely
slots and chases on vertical or horizontal surfaces.
adhering material. If concrete surfaces are defective or have
laitance, they must be cut back to a sound base.
Advantages
Pre soaking
„ Non shrink and non metallic
Soak concrete substrates for a minimum of two hours
„ High compressive strength
continuously prior to placing the grout. Immediately before
„ Can be pumped or hand placed placement all free water should be removed.

„ Chloride free Mixing and placing

„ Electrochemically compatible with cathodic protection For best results a mechanically powered grout mixer should
anode systems be used. When quantities up to 60 kg are used, a slow speed
drill fitted with a high shear mixer is suitable. Larger quantities
Description will require a high shear vane mixer. Do not use a colloidal
impeller mixer.
eGrout S50 is supplied as a ready to use dry powder. The
addition of a controlled amount of clean water will produce a To enable the grouting operation to be carried out continuously,
grout for placing into voids. it is essential that sufficient mixing capacity and labour are
available. The use of a grout holding tank with provision to
eGrout S50 is a blend of Portland cements, graded
gently agitate the grout may be required.
aggregates and additives. The low water requirement
produces a grout of high strength with good workability. Consistency of grout mix

The quantity of clean water required to be added to a 20 kg


Specification
bag to achieve the desired consistency is given below:
All repair grouting must be carried out with a pre-bagged,
non shrink, electrochemically compatible cementitious grout Hand placement : 2.8 litres
supplied by a registered firm under the ISO 9001:2000 Quality
The water should be accurately measured into the mixer. The
Assurance Scheme. The compressive strength of the grout
total contents of eGrout S50 bag should be slowly added and
shall be at least 50 N/mm2 at 28 days.
continuous mixing should take place for 5 minutes. This will
The grout must be stored, handled and placed in strict ensure that the grout has a smooth even consistency.
accordance with the manufacturers instructions. No site
Placing
batched additions to the pre-bagged grout shall be allowed.
At 35°C place the grout within 10 minutes of mixing to gain the
Properties full benefit of the expansion process.

At a water:powder ratio of 0.14 at 20°C: eGrout S50 can be placed in a single pour.

Test method Typical result Pump eGrout S50 from one point only to eliminate the
Compressive strength : 10 N/mm at 1 day
2 entrapment of air. For pumping advice please contact Fosroc.
(BS 1881 Part 116) 40 N/mm2 at 7 days
Curing
50 N/mm2 at 28 days
Expansion characteristics After grouting all exposed areas should be cured by covering
(ASTM C827-87) : Up to 2% @ 24 hours with polythene sheet securely taped down at all edges or
Electrical Resistivity using a suitable Fosroc curing compound such as
@28days : 5,000 - 6,500 Ohm-cm Rendercure*† .
eGrout S50*
eGrout S50*

Cleaning Storage

eGrout S50 should be removed from all tools and equipment Shelf life
with clean water immediately after use.
eGrout S50 has a shelf life of 12 months if kept in a dry store
Cured product can be removed mechanically or with in sealed bags.
Fosroc Acid Etch*†.
Storage conditions
Sampling procedure
Store in a cool place and out of direct sunlight. Storage at
Cementitious grouts cannot be tested as concrete. Special high temperature may reduce shelf life.
sampling procedures are required, refer to your local Fosroc
office for further details. Precautions

Health and safety


Technical support
eGrout S50 contains cement powders that when mixed or
Fosroc offers a comprehensive technical support service to
become damp, release alkalis that can be harmful to the
specifiers, end users and contractors. It is also able to offer
skin. During use, avoid inhalation of dust and contact with
on-site technical assistance, an AutoCAD facility and
skin and eyes. Wear suitable protective clothing, gloves, eye
dedicated specification assistance in locations all over the
protection and a dust mask. The use of a barrier cream
world.
provides additional skin protection. In case of contact with
eyes, rinse immediately with plenty of clean water and seek
Limitations
medical advice. In case of contact with skin, rinse with plenty
At ambient temperatures above 35°C, the mixed grout should of clean water, then cleanse with soap and water. If swallowed,
be placed immediately after mixing. Water with a temperature seek medical attention immediately - do not induce vomiting.
less than 20°C should be used for mixing.

Estimating

Supply
eGrout S50 : 20 kg bags

Yield
Hand placement : 10 litres/20 kg bag

* Denotes the trademark of Fosroc International Limited



See separate data sheet

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard
Conditions for the Supply of Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s
responsibility to obtain the recent version. Refer to www.fosroc.com.

Head Office
Al Gurg Fosroc telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
LLC Regional offices
Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Post Box 657, Dubai Bahrain, YBA Kanoo telephone: 17735454 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com
Qatar, Tadmur telephone: 4500607 fax: 4500543 email: qatar@fosroc.com
www.fosroc.com