Galvashield FMA* constructive solutions

Galvanic corrosion protection system for severe exposure


concrete elements

Uses Standards Compliance

Galvashield FMA is designed to reinstate and actively protect Galvashield FMA will, when installed and connected in
reinforced concrete/structural steel elements subject to the accordance with approved instructions, exceed the minimum
most severe exposure conditions in the tidal zone. Typical 15 year life criteria laid down by FHWA and DOT
applications include fender walls, dolphins, jetty walls etc in specifications.The design of Galvashield FMA follows
marine environments. comprehensive criteria established for the patented
‘Lifejacket’™ system developed by the Alltrista Corporation.
Advantages
Specification
! No post installation maintenance required
The galvanic protection jacket shall be Galvashield FMA, a
! Self powered and self regulating
zinc mesh anode system and shall provide a minimum
! ‘All in one’ repair and protection system working life of 15 years.

! Longest life expectancy of any galvanic system


Instructions for use
! Satisfies the 100mV criteria for effective cathodic protection
Preparation
! Proven technology with measured performance
In order for Galvashield FMA to function correctly, steel
! Provides highly cost effective repair vs comparable reinforcing must be continuous, if not, continuity must be
systems established throughout the structure prior to making
connections (see detailed method statement).
! Quick, easy and low cost installation, no costly electrical
work or monthly monitoring Make any repairs to the substrate using Renderoc repair
products as necessary prior to commencing the Galvashield
Description FMA preparation proceedures. Grit or water blast the substrate
to remove all coatings, laitence, grease, marine fouling or
Galvashield FMA is a galvanic protection system based upon
any other deleterious material.
the installation of a zinc mesh anode system conforming to
ASTM A-190. The anode system is connected to the steel Fix cathode connectors in predrilled holes by compression
reinforcement to provide the required protective current to the using a hammer and setting tool. The holes for the cathode
steel. Contact to the surface of the concrete is maintained by connections are to be filled with Nitomortar PE. When cathode
purpose designed compression members. connections are made, continuity cross checks are to be made
(see detailed method statement).
Galvashield FMA can be applied to rectangular, circular or flat
substrate profiles. The cathode connectors are fixed to the mesh by soldering.
After fixing, continuity between the mesh and cathode
A replaceable bulk anode may be incorporated into the system
connections is to be checked. Each mesh sheet fixed is
in order to provide considerable lifetime extension where
connected to the adjacent sheet by soldring (see detailed
required.
method statement).

Design Criteria Mesh fixing procedure

Galvashield FMA is a cathodic protection system utilising the The Galvashield FMA mesh is fixed to the concrete using
long proven principle of galvanic protection to provide long compresion members (see detailed method statement).
term durability to both new and existing structures in
conditions of extreme exposure such as splash and tidal
zones in marine environments.
Galvashield FMA*

In line with other galvanic protection systems, Galvashield FMA


must be designed and the installation supervised by a
specialist in the field of corrosion control.
Galvashield FMA*

Estimating

Supply

Galvashield FMA is supplied in sheet form ready to use, some


cutting may be required on site to suit particular design
features.

Precautions

Health and safety

There are no known health and safety hazards associated


with Galvashield FMA.

* Denotes the trademark of Fosroc International Limited



See separate data sheet

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard
Conditions for the Supply of Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s
responsibility to obtain the recent version. Refer to www.fosroc.com.

Head Office
Al Gurg Fosroc telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
LLC Regional offices
Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Post Box 657, Dubai Bahrain, YBA Kanoo telephone: 17735454 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com

www.fosroc.com
Qatar, Tadmur telephone: 4500607 fax: 4500543 email: qatar@fosroc.com

UAE/0417/01/A

You might also like