** ON A/C FSN ALL

TASK 33-43-00-710-001-A
Operational Test of the Runway Turnoff Lights
1. Reason for the Job
Make sure that the turnoff lights operate correctly.

2. Job Set-up Information

A. Referenced Information

REFERENCE DESIGNATION
Ref. 24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External P
ower
Ref. 24-41-00-861-002-A01 Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02 Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from t
he External Power
Ref. 24-41-00-862-002-A01 De-energize the Aircraft Electrical Circuits Supplied from t
he APU
Ref. 24-41-00-862-002-A02 De-energize the Aircraft Electrical Circuits Supplied from t
he Engine 1(2)

3. Job Set-up
SUBTASK 33-43-00-861-051-A
A. Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.

SUBTASK 33-43-00-865-050-A
B. Make sure that this (these) circuit breaker(s) is (are) closed:

PANEL DESIGNATION FIN LOCATION


LIGHTING/EXT LT/TAXI AND TAKE
122VU 2LR W09
OFF/CTL
LIGHTING/EXT LT/RWY TURN OF
122VU 1LC1 W06
F/L
LIGHTING/EXT LT/RWY TURN OF
122VU 1LC2 W05
F/R

4. Procedure
SUBTASK 33-43-00-710-050-A
A. Operational Test of Lights

1/2
ACTION RESULT
On the panel 25VU: On the nose landing gear:
- set the RWY TURN OFF switch to O - the runway turnoff lights come on,
N,
- set the RWY TURN OFF switch to OF - the runway turnoff lights go off.
F.

SUBTASK 33-43-00-862-051-A
B. De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.

5. Close-up
SUBTASK 33-43-00-942-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.