Ultra-precise
complicated analysis routines and clutter valuable workspace are not welcome.
The Ultrapyc series of gas pycnometers is the solution for you. We have
combined decades of knowledge in producing fast, accurate, and reliable solid
density measurement with groundbreaking innovations and a state-of-the-art
graphical user interface to create the most user-friendly gas pycnometer on the
market today.
Pressure transducer
Reference chamber 1
Gas input
Sample is loaded The system is then When stable, a From the resulting
into a chamber pressurized to a valve opens to pressure drop
of known volume specified value with allow the gas to the volume,
using the TruLock the analysis gas. expand into another and therefore
lid. chamber whose true density, of
volume is also the sample is Sample chamber
known. calculated.
Reference chamber 2
The features that make Ultrapyc
ultra-simple and ultra-precise
Accuracy: 0.02 %
Large cell: 135 cm3
Repeatability: 0.01 %
Accuracy: 0.02 %
Medium cell: 50 cm3
Repeatability: 0.01 %
Accuracy: 0.03 %
Small cell: 10 cm3
Repeatability: 0.015 %
Accuracy: 0.10 %
Micro cell: 4.5 cm3
Repeatability: 0.05 %
Accuracy: 0.30 %
Meso cell: 1.8 cm3
Repeatability: 0.15 %
Cements The true density
Accuracy: 1.00 %
of cement is used for the Nano cell: 0.25 cm3
Repeatability: 0.50 %
Powder coatings and dried accurate calculation of powder
film coatings The crystallinity characteristics. Measured after Preparation modes Flow, pulse, vacuum
of plastics and the true density setup time, the insights gained Transducer accuracy Better than 0.1 %
of dry pigments are monitored are important for formation and
by gas pycnometry to better stability determination. Pressure reading resolution Digital pressure display resolution of 0.0001 psi
understand the mechanical Ceramics and catalysts
Connections 4 USB ports
behavior of these materials. Density values are used in the
In addition, gas pycnometry development, manufacturing, Instrument dimensions
can help determine the volatile and troubleshooting of refractory
organic content within dried materials to confirm that the Weight 10 kg
films in order to assess the level desired crystal phase is present WxDxH 27 cm x 48 cm x 25 cm
of curing. and closed porosity is absent.
Built-in temperature range 15 °C to 50 °C with stability better than ±0.05 °C
Available connectivity to any balance using RS232 communication | Results available on screen, via a printer, or electronically
in text and pdf formats | All units calibrated at the factory using NIST-traceable spheres | A pressurized gas source
up to 20 psi and a standard power outlet are required for operation.
Accessories
Mining and oil exploration
Gas pycnometry is the primary
technique used to quickly
assess the composition of the
solids used in drilling fluids.
www.anton-paar.com