EC-401

Microbiocide
Product Data Sheet

Description & Use Handling Precautions

EC-401 is a combination of organic compounds EC-401 is a corrosive material that causes eye
formulated in an aqueous solution. and skin burns. In addition EC-401 may cause allergic
skin reactions in susceptible individuals. The product may
EC-401 is a broad spectrum non oxidizing microbiocide be harmful if inhaled. Do not get in eyes, on clothing,
for closed and open re-circulating systems. It is designed or on skin.
to provide excellent control of microbiological growth
and associated Bio-deposits. NOTE: Don’t mix with other chemicals in a concentrated
form.
General Specifications
Wear rubber gloves, an impervious rubber apron, and
Form: Liquid goggles or a face shield when handling EC-401. In case
Appearance: Yellow/Greenish of eye or skin contact, immediately flush eye or skin with
Specific gravity: 0.98-1.1 plenty of water for at least 15 minutes and get medical
attention. Remove and wash contaminated clothing before
Flash point: None
use.
pH: <5.5
Solubility in water: Complete
Storage
Features & Benefits
Store the containers tightly closed and in well ventilated
place.
•  elps minimizes Bio-Films & restore system efficiency
H
• Helps minimize slime problems which can cause Shelf Life: 2 Years
costly reduction in heat transfer
• Minimum discharge problem, active molecules are
environmentally degradable
Packing
• Simple control, effective against a broad spectrum of
micro-organisms EC-401 is available in 25 Kg and 200 Kg PE drums.
• Easy application, active at low dosages
• Provides a long lasting killing effect., which enables
less frequent biocide addition
• Easily detoxified so it can be applied even in
environmentally sensitive areas

Feeding & Dosage

The dosage of EC-401 will vary depending upon the


operating characteristics of the system, the water chemistry
and the severity of the problems encountered.

Optimum dosage is necessary to ensure maximum


program performance for Cooling systems.

Typical dosage is 30-150 ppm every 1-2 weeks for open


systems & Once every 2-3 months for closed systems.

The content of this document as presented herein are believed to be accurate and reliable to the extent known to us. However we do not assume any responsibility for whatsoever consequences resulting from
the content and/or product. They are offered solely for your consideration, investigation and verification, accordingly we shall be fully indemnified from all liabilities and legal responsibilities in all cases.

EC-401.02.051705.10.17

You might also like