ADNOC Classification: Internal

Emergency rescue plan


Work details
Job Description
KITCHEN & CLUSTER REFURBISHMENT PROJECT
Facility AUP Location Data cable building near
harbor area (PIT) / N9
cluster back side near to
masjid (PIT)
Plan developed by (PH) Date
Reference Permit /
GW # _ _ HW#_____ ___ CW #__ ____ CSE #____ ____
Certificates #
Emergency communication
Emergency phone number 026059444/659444 Emergency radio channel Channel 8 TRT
Control Room hotline 026059444/659444 Emergency assembly Harbor Area
location
Potential rescue situation
Confined Space Height Fire Electrical
Hazardous Atmosphere
Hazardous Chemical – (Ref. Others – Oxygen
Water
MSDS ) deficiency /Enrichment
___________________________
Does access / egress affect response operation?
Yes No (if YES, must be addressed in rescue plan notes)
Rescue level
Level 1 (guide note) Level 2 (guide note) Level 3 (guide note)
 Simple and quick rescue  Rescue may take time to  Complex rescue with extended time
 No hazards in immediate area perform frame
 Minor injuries  No Hazards / Low level of Risk  High hazard and risk potential in
 No specialized rescue  Minor injuries area
equipment required  Trained work team to use basic  Major injuries
rescue equipment  Trained personnel and specialized
rescue equipment required
Note:
Rescue level 1&2 – designated equipment available and rescue may be performed by trained work team members
Rescue level 3 – designated equipment staged directly at work location and requires specialist team support (TRT,
Medical).
Emergency equipment requirement
Harness with life line First aid kit Oxygen resuscitation equipment
(Island Medic Team)
Tri Pod with winch Rescue stretcher Hard hat light
Tyvek coveralls (NA) Breathing apparatus Firefighting equipment
Automated external defibrillator Personal gas monitor Other: Mechanical Rope system
(AED) Accessories ( Rescue pulley available)
( Island Medic Team)
Rescue plan includes (attach photo/drawing if required)
Entry and exit points Location of rescue Members of rescue team
Evacuation points equipment Location of rescue team (Onsite or
Location of identified hazards Offsite)
Rescue plan notes:
Rescue preparation (shall be completed prior to start the activity):
 Safety perimeter must be designated and clearly indicated to identify a safe zone of the work.
 Entry observer will complete required confine space entry documents.
 Full body harness: All personnel entering the wall pit must wear full body harness.
 Gas tester must be onsite at all time to determine safe LEL & Oxygen level prior to entry and after long breaks.
 All entry- personnel and rescue personnel should have valid training to entry and rescue.
 Identify- one rescue back up team member who shall notify via radio/PAGA to IFCC to activate emergency alarm and

5th Nov 2021. Version 1.0


ADNOC Classification: Internal

Emergency rescue plan


announcement, subsequently Contractor rescue team will execute rescue operations.

Rescue execution (In event of emergency requiring rescue assistance).


 Contractor rescue team will function as rescuer
 PA will identify safety perimeters to control personnel movement and hazard control under the direction of the
OSC.
 Gas Tester must confirm safe LEL & Oxygen Level prior to entry.
 Rescue Team will operate under a “Buddy System”.
 Backup Team must ready themselves to support once needed.
 Rescue Team makes entry into the Wall pit – immediately evaluates the situations and determines the
extrication/rescue methods to be utilized. Extrication/Rescue methods include:
o Contractor rescue team will utilize SCBA to enter the wall pit during rescue operations.
o Utilize the rope connected to the body harness to extricate the victim to the Medical Team. (If Needed)
o Rescuers will bring the victim near man way entry and Two (2) Rescuers extricate the victim from outside
wall pit man way.
 Following extraction from the wall pit by the Rescue Team, TRT will assist Medical with transport of the casualty to
a designated triage point.
Rescue team member
Medical Field Medical Sup. Safety Entry
responder standby watch
( Island Medic
Team)
Entry Trained First Aider Authorized Other
supervisor Gas Tester members:
(ADNOC AGT)
TRT Specialist Support ( Only for Level-3):
Drawing for
reference.

5th Nov 2021. Version 1.0


ADNOC Classification: Internal

Emergency rescue plan

MAN HOLE PIT CONFINED SPACE ENTRY/EXIT POINT AND LOCATION OF RESCUE EQUIPMENTS

Briefing requirement (Performing Authority to complete):


Participants in the rescue team have been briefed on the Yes Rescue equipment Yes
rescue plan and work briefing done prior to the work checked
commencing

PA Name PA Signature

5th Nov 2021. Version 1.0


ADNOC Classification: Internal

Emergency rescue plan


Date Time

Rescue level 1&2 – Fire & Rescue / HSE team notified about activity and location (Verbal Communication) Yes
Rescue Level 3, TRT-Fire & Safety Ops. Supervisor
Participants in the rescue team have been Yes Rescue equipment checked Yes
briefed on the rescue plan and work briefing
done prior to the work commencing
Name TRT signature

Date Time

WORK LOCATION

5th Nov 2021. Version 1.0


ADNOC Classification: Internal

Emergency rescue plan

GRID WORK LOCATION

Work
Location

Evacuation Point
Location

5th Nov 2021. Version 1.0