Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

50

TOP OF ROOF BEAM

A B
X

L/4
Owner's Discretion
4000

MAIN COLUMN
VERTICAL
1
REINFORCEMENTS

L/2
C1-F1 C1-F1

Footing Bars: 5-16mmØ


4000
(Verify @ Footing Schedule)

Y
10mmØ TIES

L/4
COLUMN SCHEDULE OF TIES
2

C1-F1 C1-F1 SECOND FLR. LEVEL

PLAN

L/4
MAIN COLUMN
1 FOUNDATION PLAN VERTICAL FOR SEISMIC REQM'T
REINFORCEMENTS PROVIDE AT LEAST

2600mm
S 3 SCALE: 1:100 THREE (3) TIES @ COLUMN
BEAM CONFINEMENT

L/2
DIMENSION 10mmØ TIES
REINFORCEMENT
FOOTING

L/4
W L T DEPTH
MARK (mm) ALONG X ALONG Y
MILLIMETER CONC. SLAB

@ elev.
Verify
SCALE: 1:35
GROUND FLR. LN.
F-1 1200 1200 250 1200 5-16mm Ø 5-16mm Ø
NAT. GRADE LN.
REBARS USED GRADE 40

4
1
S

1200mm
10mmØ COLUMN TIES
3 FOOTING SCHEDULES

250mm
S 3 SCALE: NTS

LENGTH x WIDTH
ARCHITECT: CADD BY: DRAWN BY: CHECKED BY: DATE DESCRIPTIONS PROJECT TITLE: SHEET CONTENTS: OWNER: SHEET NO.:

3
JUN JUN P. ANCHETA JUN JUN P. ANCHETA
R.A. 9266 SEC. 33 DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY A3 34
SIGNED, STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY AND
DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT.
IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE
PRC NO. : PTR NO. : DATE DATE LOCATION: JOB NO.:
Year 2021

IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
TIN NO. : PLACE ISSUED : ADDRESS :
Bulanao, Tabuk City, Kalinga 2021