Professional Documents
Culture Documents
TSH-CP-34.0001 - 06 TSH513
TSH-CP-34.0001 - 06 TSH513
TSH-CP-34.0001 - 06 TSH513
Connection Procedure
This document as well as the information or data contained herein are confidential and shall not be copied, recopied,
reproduced, transmitted, disclosed or distributed to others or otherwise used for any purpose without the express, prior
and written permission of Tenaris Connections Limited and/or Hydril Company and/or its affiliated companies ("Tenaris").
This document as well as the information or data contained herein are the exclusive property of Tenaris, and are to be
returned upon request therefore. All rights in proprietary and novel features of the subject matter are expressly reserved
by Tenaris. Recipient?s agreement to the foregoing is indicated by acceptance of this document. Copyrighted 2010 as an
unpublished work. ALL RIGHTS RESERVED.
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 2
1. REVISION HISTORY
Effective
Rev. # Change Referenced Sections Prepared By: Reviewed by: Approved By:
Date
Document Change
Disposition of
Affected Material
Raw Material X
In Process X
Completed X
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 3
2. PURPOSE
2.1 The Purpose of this document is to establish the inspection criteria for the TenarisHydril Wedge
513™ connections.
3. PERSONS AFFECTED
4. REFERENCES
5.1 Definations and abbreviations shall be as defined in the most current revision of TenarisHydril
document TSH-GP-00.0001.
6. RESPONSIBILITIES
6.1 Responsibilities are defined in the most current revision of TenarisHydril document
TSH-GP-00.0002.
7. PERSONNEL QUALIFICATION
7.1 Personnel qualification is defined in the most current revision of TenarisHydril document
TSH-GP-00.0003.
8. PROCEDURES
Page Number 4
8.2.2 Accessories
8.2.2.1 Verify blanking dimensions according to the product drawing and/or Blanking
Dimensions Table. For the recommended blanking dimensions please refer to
the TenarisHydril Web Site.
8.2.2.2 Verify compliance of accessory blank material with the purchase order.
Not Applicable.
8.3.1 TenarisHydril Wedge 513™ Connections require Swaging and Stress Relieving, please
refer to:
8.3.1.1 TSH-PP-00.0022 - Swage, Expanision, and Sizing for Pin and Box Ends.
Page Number 5
8.4.1 TenarisHydril Wedge Series connections shall be threaded on CNC machines. It is not
allowed to thread this connection on manual machines.
8.4.2 For threading Set Up details please refer to TSH-PP-00.0002 latest revision
8.5.1 Inspect and gauge the thread according to the Inspections, Gauges and Frequencies listed
below. Product acceptance shall always be performed in the out of Chuck (Free State)
condition.
8.5.2 For details regarding each Inspection please refer to the applicable Inspection
Specification which are listed in the inspection specification column of the following
TenarisHydril Wedge 513™ Pin and Box inspection.
8.5.3 Tenaris Mills and Tenaris owned facilities may implement Statistical analysis process
capability instead of the below mentioned frequencies.
8.5.4 Lots in excess of 10 connections are considered production runs, frequencies in these
cases can be reduced as specified in Inspection frequency >10 pieces table for
TenarisHydril Wedge 513™ Pin and Box inspection.
8.5.5 First and last article shall be performed in accordance with TSH-IP-00.0081.
8.5.6 The use of any "alternative" gages and/or contact points from those listed below shall
require prior written approval from TenarisHydril Connections at
licensees@oilfield.tenaris.com.
8.5.7 Gauges with lower resolution than the recommended shall not be considered for approval.
8.5.8 For all inspection, measuring and testing equipment calibrated by the licensee or outside
sources, the licensee shall maintain records documenting traceability to nationally or
internationally accepted standards.
8.5.9 A deviation request is required for any product with a turned OD or bored ID which is other
than shown on the Inspection report.
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 6
Thread Pull
0.001" TenarisHydril
9 Out (Thread TSH-IP-53.0054 100% 25% TenarisHydril Pull Out Gage ---
(0.02 mm) Proprietary Gage
End)
Page Number 7
24 End Drift TSH-IP-00.0028 100% 100% Cylindrical Mandrel --- --- See Inspection Report
Visual
25 TSH-IP-00.0031 100% 100% --- --- --- ---
Inspection
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 8
0.001"
3 Seal Width TSH-IP-00.0074 100% 25% Dial or Digital Caliper
(0.02 mm)
--- Applicable to OD< 14”
TenarisHydril proprietary
TSH-IP-53.0060 --- ---
End of Part / Gage Pin
1 & 100% 100% ---
Gage Pin 0.001"
TSH-IP-53.0075 Depth Caliper ---
(0.02 mm)
0.001"
Internal Micrometer --- Alternative I
Thread (0.02 mm)
TSH-IP-53.0062 100%
Diameter 100% 0.0005"
5 Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
Ovality/ Free
0.0005"
6 State TSH-IP-53.0066 100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 ---
(0.01 mm)
Variation
0.001"
100% 25% Internal Micrometer --- Alternative I
(0.02 mm)
7 Outer Taper TSH-IP-53.0063
0.0005"
100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
0.001"
100% 25% Internal Micrometer --- Alternative I
(0.02 mm)
8 Inner Taper TSH-IP-53.0063
0.0005"
100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
Start of
9 0.001"
Clipped TSH-IP-53.0079 100% 25% Depth Caliper --- ---
(0.02 mm)
Thread
Thread Pull Licensee shall
11 0.001"
Out (Thread TSH-IP-53.0064 100% 25% TenarisHydril Pull Out Gage --- purchase Pull Out
(0.02 mm)
End) Gage
Page Number 9
Thread Start
15 0.001"
Length (start of TSH-IP-53.0079 100% 25% Depth Caliper --- ---
(0.02 mm)
full form thread)
Relief Diameter 0.001”
19 TSH-IP-00.0080 100% 25% Internal Micrometer --- ---
After Seal (0.02mm)
Thread C-Bore
0.001"
17 Diameter at TSH-IP-00.0080 100% 25% Internal Micrometer --- ---
(0.02 mm)
Shoulder
Thread C-Bore
0.001"
18 Length at TSH-IP-00.0091 100% 25% Depth Caliper --- ---
(0.02 mm)
Shoulder
0.001" At CounterBore at
21 Minimum Wall TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer ---
(0.02 mm) Shoulder Diameter
Minimum 0.001" At CounterBore at
22 TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer ---
Average Wall (0.02 mm) Shoulder Diameter
Distance from
26 Face to 0.001"
TSH-IP-00.0092 100% 25% Depth Caliper --- ---
Shoulder After (0.02 mm)
Relief Diameter
OD Chamfer 0.001"
20 TSH-IP-00.0093 100% 25% Dial or Digital Caliper --- ---
Diameter (0.02 mm)
st st
1 & Last 1 & Last
23 Thread Overlay Part Part and
TSH-IP-00.0002 Visual / Thread Profile --- --- ---
Inspection minimum 1 per
1 per Shift
Shift
Visual
25 TSH-IP-00.0031 100% 100% Visual --- --- ---
Inspection
--- Surface Finish TSH-IP-53.0070 100% 100% Visual --- --- ---
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 10
8.6 Drifting
8.6.1 A deviation request is required for any product with a drift diameter which is other than
shown on the inspection report, or not in accordance with the diameter and length
requirements in API 5CT.
8.6.2 All upset tubing sizes material shall be full length drifted to dimension listed on IR with a
drift length in accordance to API 5CT.
8.6.3 All swaged ends or ends that have been reduced in size shall be end drifted pass the
swaged area.
8.6.4 All sized box ends shall be OD drifted.
8.7 Inspection (NDT)
8.7.1 Upon customer requirement, finished ends shall be inspected with non-destructive
methods according to API 5CT (ISO 11960).
8.8.1 The surface finish requirements for the machined TenarisHydril Wedge 513™ connections
are as follows:
2 2
8.8.2 Phosphate coating shall weight min. 5.4 g/m (min. 500 mg/ft ) seeTSH-PP-00.0006.
8.8.3 For details regarding Abrasive Blasting, also known as Texturizing, please refer to TSH-
PP-00.0007
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06
Page Number 11
8.8.4 Dopeless®
For dopeless® Option, please contact Tenaris Manufacturing Service Department at
licensees@oilfield.tenaris.com
8.8 Thread Compound
8.9.1 If a Buck-on operation is required, a Tenaris approved thread compound shall be applied
contact licensees@oilfield.tenaris.com for approved thread compounds.
8.10 Buck-on
8.11.1 For Thread Lubricant and Protection details refer to TSH-PP-00.0004, latest revision.
8.12 Identification
8.14 Deviation
8.14.1 Any deviation request from the practices established in this Inspection Procedure shall be
submitted, in writing, to Tenaris Manufacturing Services at licensees@oilfield.tenaris.com
for written approval using the Deviation Request Form.