TSH-CP-34.0001 - 06 TSH513

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

For PVD Qualification

Prepared by: Reviewed by: Approved by:

Michael Soptick Ruben Stubelt Daniel Baiz


Premium Connections Premium Connections Premium Connections
Manufacturing Services Specialist Manufacturing Services Coordinator Manufacturing Engineering Manager
Tenaris Tenaris Tenaris

Connection Procedure

TenarisHydril Wedge 513TM

Document Number TSH-CP-34.0001


Revision 06
Revision Date 06-Apr-2010
Effective Date 14-Apr-2010
Page(s) 11

This document as well as the information or data contained herein are confidential and shall not be copied, recopied,
reproduced, transmitted, disclosed or distributed to others or otherwise used for any purpose without the express, prior
and written permission of Tenaris Connections Limited and/or Hydril Company and/or its affiliated companies ("Tenaris").
This document as well as the information or data contained herein are the exclusive property of Tenaris, and are to be
returned upon request therefore. All rights in proprietary and novel features of the subject matter are expressly reserved
by Tenaris. Recipient?s agreement to the foregoing is indicated by acceptance of this document. Copyrighted 2010 as an
unpublished work. ALL RIGHTS RESERVED.
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 2

1. REVISION HISTORY

Effective
Rev. # Change Referenced Sections Prepared By: Reviewed by: Approved By:
Date

01-Oct-2008 01 New Document New Document


Name: M. Soptick Name: R. Stubelt Name: D. Baiz
Section 8.3.1, 8.5, 8.6.2,
01-Apr-2009 02 Amended 8.9.1, 8.10.1, and
8.3.1.2 Name: M. Soptick Name: R. Stubelt Name: D. Baiz
Pin Chamfer
30-Apr.-2009 03 8.5
Dia.
Name: M. Soptick Name: R. Stubelt Name: D. Baiz
Changed
symbol from
15-May-2009 04 to . Added 8.5.4, and 8.6.4
drifting of sized Name: M. Soptick Name: R. Stubelt Name: D. Baiz
Boxes.
Sections 8.5.8, 8.8.1,
18-Mar-2010 05 Amended 8.9, 8.10, 8.15, and 8.3.1
Added 8.1, 8.8.4, Name: M. Soptick Name: R. Stubelt Name: D. Baiz

06-Apr-2010 06 Amended 8.5 End Drift


Name: M. Soptick Name: R. Stubelt Name: D. Baiz

Document Change

Disposition of
Affected Material

Raw Material X
In Process X
Completed X
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 3

2. PURPOSE

2.1 The Purpose of this document is to establish the inspection criteria for the TenarisHydril Wedge
513™ connections.

3. PERSONS AFFECTED

3.1 This document is applicable to all:


3.1.1 All TenarisHydril Premium Connections Manufacturing Services Personnel.
3.1.2 Facilities licensed to thread TenarisHydril Wedge 513™ connections.

4. REFERENCES

4.1 API Specification 5CT (ISO 11960)

5. DEFINITIONS AND ABBREVIATIONS

5.1 Definations and abbreviations shall be as defined in the most current revision of TenarisHydril
document TSH-GP-00.0001.

6. RESPONSIBILITIES

6.1 Responsibilities are defined in the most current revision of TenarisHydril document
TSH-GP-00.0002.

7. PERSONNEL QUALIFICATION

7.1 Personnel qualification is defined in the most current revision of TenarisHydril document
TSH-GP-00.0003.

8. PROCEDURES

8.1 General - TSH W513™ Options:- Dopeless®

Box Connection Overview


For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 4

Pin Connection Overview

8.2 Blanking, Dimensions, and Coupling Stock

8.2.1 Material Grades

8.2.1.1 See Tenaris general procedure TSH-GP-53.0001.

8.2.2 Accessories

8.2.2.1 Verify blanking dimensions according to the product drawing and/or Blanking
Dimensions Table. For the recommended blanking dimensions please refer to
the TenarisHydril Web Site.

8.2.2.2 Verify compliance of accessory blank material with the purchase order.

8.2.2.3 Receiving inspection shall be performed on purchased and customer supplied


material.
8.2.3 Mother Pipe

8.2.3.1 Receiving inspection shall be performed on purchased and customer supplied


material.

8.2.4 Coupling Stock

Not Applicable.

8.3 Swaging and Stress Relief

8.3.1 TenarisHydril Wedge 513™ Connections require Swaging and Stress Relieving, please
refer to:

8.3.1.1 TSH-PP-00.0022 - Swage, Expanision, and Sizing for Pin and Box Ends.

8.3.1.2 TSH-ML-34.0002 - Swage Tooling Masterlist

8.3.1.3 TSH-SW-34.0001 - Swage Data.

8.3.1.4 TSH-PP-00.0012 - Stress Relieving.

8.3.1.5 TSH-SW-34.0004 – Box Sizing Data.


For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 5

8.4 Threading Process

8.4.1 TenarisHydril Wedge Series connections shall be threaded on CNC machines. It is not
allowed to thread this connection on manual machines.

8.4.2 For threading Set Up details please refer to TSH-PP-00.0002 latest revision

8.4.3 If a modification on any other parameter is required, Tenaris Manufacturing Service


Department shall be contacted for approval at licensees@oilfield.tenaris.com
8.4.4 The licensee shall assure the CNC program revision, the TenarisHydril licensee product
drawings, and inspection report are the most current revision and the same.

8.4.5 Threading Inserts


8.4.5.1 See Inspection Report to determine the correct threading insert.

8.5 Gauging and Inspection Frequency

8.5.1 Inspect and gauge the thread according to the Inspections, Gauges and Frequencies listed
below. Product acceptance shall always be performed in the out of Chuck (Free State)
condition.
8.5.2 For details regarding each Inspection please refer to the applicable Inspection
Specification which are listed in the inspection specification column of the following
TenarisHydril Wedge 513™ Pin and Box inspection.
8.5.3 Tenaris Mills and Tenaris owned facilities may implement Statistical analysis process
capability instead of the below mentioned frequencies.
8.5.4 Lots in excess of 10 connections are considered production runs, frequencies in these
cases can be reduced as specified in Inspection frequency >10 pieces table for
TenarisHydril Wedge 513™ Pin and Box inspection.
8.5.5 First and last article shall be performed in accordance with TSH-IP-00.0081.
8.5.6 The use of any "alternative" gages and/or contact points from those listed below shall
require prior written approval from TenarisHydril Connections at
licensees@oilfield.tenaris.com.
8.5.7 Gauges with lower resolution than the recommended shall not be considered for approval.
8.5.8 For all inspection, measuring and testing equipment calibrated by the licensee or outside
sources, the licensee shall maintain records documenting traceability to nationally or
internationally accepted standards.
8.5.9 A deviation request is required for any product with a turned OD or bored ID which is other
than shown on the Inspection report.
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 6

TenarisHydril Wedge 513™ Pin Inspection


Insp. Freq.
Inspection Inspection Insp. Freq. Contact Point
<10 Gage / Standard Accuracy Notes
Name Procedure >10 pieces Diameter
pieces
TenarisHydril proprietary Applicable to OD< 14”
TSH-IP-53.0052 --- ---
Seal Gauge
& 100%
100% 0.001" Gauge provided by
TSH-GP-00.0007 Dial or Digital Caliper ---
(0.02 mm) Tenaris
2 Primary Seal
0.0001" Applicable to OD > 14”
Gagemaker MRP or Similar TSH-IP-53.0071
(0.001 mm)
TSH-IP-53.0057 100% 100%
TenarisHydril proprietary Set Master provided by
--- ---
Pin Seal Set Master Tenaris
TenarisHydril proprietary
--- --- Applicable to OD< 14”
Seal Bluing Seal Gauge
3 TSH-IP-00.0074 100% 100%
Seal Finish Gauge provided by
Visual of Bluing --- --- Tenaris
0.001" Applicable to
3 Seal Width TSH-IP-00.0074 100% 25% Visual / Dial or Digital Caliper ---
(0.02 mm) OD< 14”
st
1 & Last st
1 & Last
Thread Part,
Part and
21 Overlay TSH-IP-00.0002 minimum Visual / Thread Profile --- --- ---
1 per
Inspection 1 per
Shift
Shift
TenarisHydril proprietary
TSH-IP-53.0051 --- ---
End of Part / Gage Pin
1 & 100% 100% ---
Gage Pin 0.001"
TSH-IP-53.0075 Depth Caliper ---
(0.02 mm)
0.001"
100% 100% Blade Micrometer --- Alternative I
Thread (0.02 mm)
5 TSH-IP-53.0053
Diameter 0.0005"
100% 100% Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
Ovality / Free
0.0005"
6 State TSH-IP-53.0055 100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 ---
(0.01 mm)
Variation
0.001"
100% 25% Blade Micrometer --- Small Quantity Orders
(0.02 mm)
0.0005"
100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 Large Order
(0.01 mm)
7 Taper TSH-IP-53.0050
0.0005" Contact Shoes: Large Orders
2 Gagemaker MRP or Similar
(0.01 mm) Min. 1.000"
100% 25% Applicable only when
TenarisHydril proprietary Std. provided by
--- ---
Standard Tenaris
Thread Start
Length (Start 0.001"
8 TSH-IP-53.0079 100% 25% Depth Caliper --- ---
of Full Form (0.02 mm)
Thd.)

8 Higbee TSH-IP-53.0069 100% 100% Visual --- --- ---

Thread Pull
0.001" TenarisHydril
9 Out (Thread TSH-IP-53.0054 100% 25% TenarisHydril Pull Out Gage ---
(0.02 mm) Proprietary Gage
End)

20 Roller Marker TSH-PP-00.0005 100% 100% Visual --- --- ---


For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 7

TenarisHydril Wedge 513™ Pin Inspection


Insp. Freq.
Inspection Inspection Insp. Freq. Contact Point
<10 Gage / Standard Accuracy Notes
Name Procedure >10 pieces Diameter
pieces
TenarisHydril proprietary 0.0005" Licensee shall
TSH-IP-53.0071
Load Flank Lead Gage (0.01 mm) purchase Lead Gage
10 TSH-IP-53.0056 100% 25%
Lead
TenarisHydril proprietary
--- --- Provided by Tenaris
Lead Standard

TenarisHydril proprietary 0.0005" Licensee shall


TSH-IP-53.0071
Stab Flank Lead Gage (0.01 mm) purchase Lead Gage
11 TSH-IP-53.0056 100% 25%
Lead
TenarisHydril proprietary
--- --- Provided by Tenaris
Lead Standard

Min. Full 0.001"


22 TSH-IP-00.0021 100% 100% Dial or Digital Caliper --- ---
Form Thread (0.02 mm)
Connection Dial or Digital Caliper or 0.001"
16 TSH-IP-00.0040 100% 50% --- ---
Length Depth Micrometer (0.02 mm)
Turned Dia. 0.001"
12 TSH-IP-00.0045 100% 25% Blade or External Micrometer --- ---
Behind Thrd (0.02 mm)
Counter bore 0.001"
19 TSH-IP-00.0026 100% 100% Dial or Digital Caliper --- Check only if applicable
Length (0.02 mm)
Bored ID 0.001"
13 TSH-IP-00.0025 100% 50% Internal Micrometer --- ---
Diameter (0.02 mm)
Surface
Turning Profiling
--- Finish TSH-IP-53.0070 100% 100% --- --- ---
Visual Standards
Inspection
Counter bore 0.001"
18 TSH-IP-00.0025 100% 25% Internal Micrometer --- Check only if applicable
Diameter (0.02 mm)
Chamfer 0.001"
17 TSH-IP-00.0025 100% 25% MRP --- Check only if applicable
Diameter (0.02 mm)
Minimum 0.001"
14 TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer --- Back of Pin
Wall (0.02 mm)
Minimum 0.001"
15 TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer --- Back of Pin
Average Wall (0.02 mm)

24 End Drift TSH-IP-00.0028 100% 100% Cylindrical Mandrel --- --- See Inspection Report

Visual
25 TSH-IP-00.0031 100% 100% --- --- --- ---
Inspection
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 8

TenarisHydril Wedge 513™ Box Inspection


Insp. Freq.
Inspection Inspection Insp. Freq. Contact Point
<10 Gage / Standard Accuracy Notes
Name Procedure >10 pieces Diameter
pieces
TenarisHydril proprietary Applicable to OD< 14”
TSH-IP-53.0061 --- ---
Seal Gauge
& 100% 100%
TSH-GS-00.0007 Dial or Digital Caliper / Filler 0.001" Gauge provided by
2 --- Tenaris
Primary Seal Gauge (0.02 mm)
0.0001" Applicable to OD > 14”
Gagemaker MRP or Similar TSH-IP-53.0071
(0.001 mm)
TSH-IP-53.0057 100% 100%
TenarisHydril proprietary Set Master provided by
--- ---
Pin Seal Set Master Tenaris
TenarisHydril proprietary
--- --- Applicable to OD< 14”
Seal Bluing Seal Gauge
3 TSH-IP-00.0074 100% 100%
Seal Finish Gauge provided by
Bluing --- --- Tenaris

0.001"
3 Seal Width TSH-IP-00.0074 100% 25% Dial or Digital Caliper
(0.02 mm)
--- Applicable to OD< 14”

TenarisHydril proprietary
TSH-IP-53.0060 --- ---
End of Part / Gage Pin
1 & 100% 100% ---
Gage Pin 0.001"
TSH-IP-53.0075 Depth Caliper ---
(0.02 mm)
0.001"
Internal Micrometer --- Alternative I
Thread (0.02 mm)
TSH-IP-53.0062 100%
Diameter 100% 0.0005"
5 Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
Ovality/ Free
0.0005"
6 State TSH-IP-53.0066 100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 ---
(0.01 mm)
Variation
0.001"
100% 25% Internal Micrometer --- Alternative I
(0.02 mm)
7 Outer Taper TSH-IP-53.0063
0.0005"
100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
0.001"
100% 25% Internal Micrometer --- Alternative I
(0.02 mm)
8 Inner Taper TSH-IP-53.0063
0.0005"
100% 25% Gagemaker MRP or Similar TSH-IP-53.0071 Alternative II
(0.01 mm)
Start of
9 0.001"
Clipped TSH-IP-53.0079 100% 25% Depth Caliper --- ---
(0.02 mm)
Thread
Thread Pull Licensee shall
11 0.001"
Out (Thread TSH-IP-53.0064 100% 25% TenarisHydril Pull Out Gage --- purchase Pull Out
(0.02 mm)
End) Gage

33 Applicable Drift techniques


End Drift TSH-IP-00.0028 100% 100% --------- ------------ See Inspection Report
detailed in TSH-IP-00.0028
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 9

TenarisHydril Wedge 513™ Box Inspection


Insp. Freq.
Inspection Inspection Insp. Freq. Contact Point
<10 Gage / Standard Accuracy Notes
Name Procedure >10 pieces Diameter
pieces
TenarisHydril proprietary 0.0005" Licensee shall
TSH-IS-53.0071
Load Flank Lead Gage (0.01 mm) purchase Lead Gage
12 TSH-IP-53.0056 100% 25%
Lead
TenarisHydril proprietary
--- --- Provided by Tenaris
Lead Standard
TenarisHydril proprietary 0.0005" Licensee shall
TSH-IS-53.0071
Stab Flank Lead Gage (0.01 mm) purchase Lead Gage
13 TSH-IP-53.0056 100% 25%
Lead
TenarisHydril proprietary
--- --- Provided by Tenaris
Lead Standard
Counter-Bore
Internal Micrometer 0.001"
14 Diameter at TSH-IP-00.0080 100% 25% --- ---
Dial or Digital Caliper (0.02 mm)
Box Face
Counter-Bore
0.001"
16 Length at Box TSH-IP-00.0087 100% 25% Dial or Digital Caliper --- ---
(0.02 mm)
Face
Clipped Thread 0.001"
10 TSH-IP-53-0067 100% 25% Internal Micrometer --- ---
Diameter (0.02 mm)

15 Higbee TSH-IP-53.0069 100% 100% Visual --- --- ---

Thread Start
15 0.001"
Length (start of TSH-IP-53.0079 100% 25% Depth Caliper --- ---
(0.02 mm)
full form thread)
Relief Diameter 0.001”
19 TSH-IP-00.0080 100% 25% Internal Micrometer --- ---
After Seal (0.02mm)
Thread C-Bore
0.001"
17 Diameter at TSH-IP-00.0080 100% 25% Internal Micrometer --- ---
(0.02 mm)
Shoulder
Thread C-Bore
0.001"
18 Length at TSH-IP-00.0091 100% 25% Depth Caliper --- ---
(0.02 mm)
Shoulder
0.001" At CounterBore at
21 Minimum Wall TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer ---
(0.02 mm) Shoulder Diameter
Minimum 0.001" At CounterBore at
22 TSH-IP-00.0073 100% 100% Deep Throat Wall Micrometer ---
Average Wall (0.02 mm) Shoulder Diameter
Distance from
26 Face to 0.001"
TSH-IP-00.0092 100% 25% Depth Caliper --- ---
Shoulder After (0.02 mm)
Relief Diameter
OD Chamfer 0.001"
20 TSH-IP-00.0093 100% 25% Dial or Digital Caliper --- ---
Diameter (0.02 mm)

st st
1 & Last 1 & Last
23 Thread Overlay Part Part and
TSH-IP-00.0002 Visual / Thread Profile --- --- ---
Inspection minimum 1 per
1 per Shift
Shift

24 Roller Marker TSH-PP-00.0005 100% 100% Visual --- --- ---

Visual
25 TSH-IP-00.0031 100% 100% Visual --- --- ---
Inspection

--- Surface Finish TSH-IP-53.0070 100% 100% Visual --- --- ---
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 10

8.6 Drifting
8.6.1 A deviation request is required for any product with a drift diameter which is other than
shown on the inspection report, or not in accordance with the diameter and length
requirements in API 5CT.
8.6.2 All upset tubing sizes material shall be full length drifted to dimension listed on IR with a
drift length in accordance to API 5CT.
8.6.3 All swaged ends or ends that have been reduced in size shall be end drifted pass the
swaged area.
8.6.4 All sized box ends shall be OD drifted.
8.7 Inspection (NDT)
8.7.1 Upon customer requirement, finished ends shall be inspected with non-destructive
methods according to API 5CT (ISO 11960).

8.7.2 Acceptance / Rejection criteria shall be in accordance to TSH-IP-00.0077. Disposition shall


be in accordance with Customer or API requirements.

8.8 Surface Finish Treatment

8.8.1 The surface finish requirements for the machined TenarisHydril Wedge 513™ connections
are as follows:

Materials Pin End Box End


Carbon/ Low Alloy Steel
Mn. Or Zn. Phosphate Mn. Or Zn. Phosphate
Grade Descriptions
Alloy with Grade Mn or Zn Phosphate Mn or Zn Phosphate
Descriptions ( Abrasive Blast if needed ( Abrasive Blast if needed
Less than 4.5% and Greater for activation prior to for activation prior to
than 1.2% Cr phoshating) phoshating)
Alloy Grades Descriptions
Abrasive Blasting Abrasive Blasting
Greater than 4.5 Cr

CRA Material Grades


Abrasive Blasting Abrasive Blasting
Descriptions

Nickel Base Alloys Grades Abrasive Blasting Abrasive Blasting

Aluminum Abrasive Blasting Abrasive Blasting

2 2
8.8.2 Phosphate coating shall weight min. 5.4 g/m (min. 500 mg/ft ) seeTSH-PP-00.0006.
8.8.3 For details regarding Abrasive Blasting, also known as Texturizing, please refer to TSH-
PP-00.0007
For PVD Qualification Document Type Connection Procedure
Document Number TSH-CP-34.0001
TM
TenarisHydril Wedge 513 Revision 06

Page Number 11

Anchor Pattern Almen


Min. Max. Min. Max.

1.0 mil 2.0 mil See TSH-PP-00.0007

8.8.4 Dopeless®
For dopeless® Option, please contact Tenaris Manufacturing Service Department at
licensees@oilfield.tenaris.com
8.8 Thread Compound

8.9.1 If a Buck-on operation is required, a Tenaris approved thread compound shall be applied
contact licensees@oilfield.tenaris.com for approved thread compounds.

8.10 Buck-on

8.10.1 If a Buck-on operation is required, refer to TSH-PP-00.0003 for details.

8.11 Storage Compound application and Protection

8.11.1 For Thread Lubricant and Protection details refer to TSH-PP-00.0004, latest revision.

8.12 Identification

8.12.1 For identification details refer to TSH-PP-00.0005. latest revision.

8.13 Additional and Special Customer Requirements

8.13.1 See customer Puchasing documents or Quality Control Plan.

8.14 Deviation

8.14.1 Any deviation request from the practices established in this Inspection Procedure shall be
submitted, in writing, to Tenaris Manufacturing Services at licensees@oilfield.tenaris.com
for written approval using the Deviation Request Form.

8.15 Repair or Conversion of Threaded Connections


See TSH-IP-53.0080 for TSH Wedge connections.

9. ANNEX

9.1 Not Applicable.

You might also like