Inspection Procedure
This document as well as the information or data contained herein are confidential and shall not be copied, recopied,
reproduced, transmitted, disclosed or distributed to others or otherwise used for any purpose without the express, prior
and written permission of Tenaris Connections AG and/or Hydril Company and/or its affiliated companies ("Tenaris").
This document as well as the information or data contained herein are the exclusive property of Tenaris, and are to be
returned upon request therefore. All rights in proprietary and novel features of the subject matter are expressly reserved
by Tenaris. Recipient’s agreement to the foregoing is indicated by acceptance of this document. Copyrighted 2009 as an
unpublished work. ALL RIGHTS RESERVED.
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0025
Bore / Counter Bore Diameter Inspection Revision 02
Page Number 2
1. REVISION HISTORY
Effective
Rev. # Change Referenced Sections Prepared By: Reviewed by: Approved By:
Date
Document Change
Disposition of
Affected Material
Raw Material X
In Process X
Completed X
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0025
Bore / Counter Bore Diameter Inspection Revision 02
Page Number 3
2. PURPOSE
2.1 The Purpose of this document is to explain the measurement of the Bore and Counter Bore
Diameter.
3. PERSONS AFFECTED
4. REFERENCES
5.1 Definitons and Abbreviations are defined in the most current revision of TenarisHydril document
TSH-GP-00.0001.
The End Bore ensures that a consistent pin nose thickness is maintained. The pin bore diameter
inspection is only required when the bore diameter is machined. In some cases black areas in the
bore area are allowed; please refer to the appropriate drawing and/or inspection report for details.
6. RESPONSIBILITIES
6.1 Responsibilities are defined in the most current revision of TenarisHydril document
TSH-GP-00.0002.
7. PERSONNEL QUALIFICATION
7.1 Personnel qualification is defined in the most current revision of TenarisHydril document
TSH-GP-00.0003.
8. PROCEDURES
8.1 Inspection
The measurement of the pin end bore / counter bore diameter is made by placing a caliper or ID
micrometer, within the turned surface of the bore, making sure that the two contact anvils touch
the machined surface of the bore. One anvil is held stationary while the other is rotated through a
small arc while slightly expanding the caliper or ID micrometer until the greatest distance is
found. Determine the high and low readings around the circumference of the bore and average
them to obtain a Bore Diameter Value.
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0025
Bore / Counter Bore Diameter Inspection Revision 02
Page Number 4
Page Number 5
Set up MRP or simular gage with swivel pivot shoes or ball points, use calibrated measuring
instrutment set “A” dimension as listed on the inspection report (IR). Set “B” dimension using a
calibrated instrutment to nominal dimension listed on the IR. Insert MRP gage into ID with block wear
pads against face of part and rotate 180 degrees.
8.3 Records
The result of these inspections shall be recorded on the IR.