Professional Documents
Culture Documents
SVSW-007002-G09-0001 Rev B Catalogue Data - Code 1
SVSW-007002-G09-0001 Rev B Catalogue Data - Code 1
PRESSURE GAUGE
ITEM: PI‐2882‐1,PI‐2882‐2,PI‐2882‐3,PI‐2880‐2A,PI‐2880‐3,PI‐2880‐4,PI‐
2880‐5,PI‐2880‐6,PI‐2880‐7,PI‐2880‐8,PI‐2880‐9, PI‐2881‐1,PI‐2881‐2,PI‐
2881‐3,PI‐2880‐1A,PI‐2880‐10,PI‐2880‐11,PI‐2880‐12, PI‐2880‐13, PI‐
29XX‐6,PI‐29XX‐7,PI‐29XX‐8, PI‐29XX‐9
SWAGELOK
RELIEF VALVE
ITEM: PSV‐2883, PSV‐2885
www.swagelok.com
P ro p o r t i o n a l R e l i e f Va l v e s
R Series
■ Liquid or gas service
Cap
provides easy external
Spring
set pressure adjustment
adjusts to provide
desired set pressure Label
identifies set
pressure range
Lock nut
maintains cap position, Lock wire capability
ensuring set pressure adjustment secures cap to maintain
set pressure adjustment
Quad seal
eliminates leakage
around stem during
relief mode
O-ring
provides elastomer-to-metal End connections
seal for positive shutoff at seat. include gaugeable Swagelok tube
(Other series use bonded disc. fittings and NPT or ISO pipe threads
See Materials of Construction)
Features Applications
High-Pressure Valves R series relief valves are proportional relief valves that open
gradually as the pressure increases. Consequently, they do
■ Service up to 6000 psig (413 bar)
not have a capacity rating at a given pressure rise
■ Multiple springs for a selection of set pressure ranges (accumulation), and they are not certified to ASME or any
■ 1/4 in. and 6 and 8 mm end connections—R3A series other codes.
■ 1/2 in. and 12 mm end connections—R4 series The system designer and user must determine
applicable code requirements and whether R series
Low-Pressure Valves relief valves are acceptable for use.
■ Service up to 300 psig (20.6 bar)
■ One spring for the full set pressure range Operation
■ 1/4 in. and 6 and 8 mm end connections—RL3 series R series relief valves OPEN when system pressure reaches
■ 1/2 in. and 12 mm end connections—RL4 series the set pressure and CLOSE when system pressure falls
below the set pressure.
■ High-pressure R3A and R4 series—select and install the
spring that covers the required set pressure; apply the
matching label to the cap.
■ Low-pressure RL3 and RL4 series—the spring is already
installed.
For valves not actuated for a period of time, initial
relief pressure may be higher than the set pressure.
Proportional Relief Valves 3
Technical Data
Pressure-Temperature Ratings
Series R3A R4 RL3 and RL4
Working Pressure at 6000 psig (413 bar);
6000 psig (413 bar) 300 psig (20.6 bar)
70°F (20°C) up to 8000 psig (551 bar) during relief
Set Pressure➀ 50 to 6000 psig (3.4 to 413 bar) 50 to 1500 psig (3.4 to 103 bar) 10 to 225 psig (0.68 to 15.5 bar)
Outlet Pressure➁ 1500 psig (103 bar) 2500 psig (172 bar) 225 psig (15.5 bar)
Fluoro- Ethylene Fluoro- Ethylene Fluoro- Ethylene
carbon Neo- pro- carbon Neo- pro- carbon Neo- pro-
Seal Material FKM Buna N prene pylene FKM Buna N prene pylene FKM Buna N prene pylene
Temperature, °F (°C) Maximum Set Pressure, psig (bar)
–40 (–40) —
— —
–30 (–34) —
—
–10 (–23) — —
—
0 (–17) — — —
10 (–12) 6000
6000 (413)
25 (–4)
6000 (413)
30 (–1) 6000
(413)
50 (10) (413) 225
225 (15.5)
5580 5580 5580 5580 225 (15.5)
150 (65) 225 (15.5)
(384) (384) (384) (384) (15.5)
1500 1500 1500
5160 5160 5160 5160 (103) (103) (103)
200 (93) 1500
(355) (355) (355) (355)
(103)
4910 4910 4910 4910
250 (121)
(338) (338) (338) (338)
275 (135) 4660
— — — — —
300 (148) (321) —
➀ The pressure-temperature ratings are based upon laboratory testing to ensure that the cracking pressure does not deviate by more than 20 % from the initial room
temperature set pressure.
➁ Outlet pressure should not exceed inlet pressure.
Materials of Construction
Component Material Grade/ASTM Specification
RL3 and R3A RL4 and R4 RL3, R3A—nickel-plated brass;
1 Plug
RL4, R4—brass
1 1
2 2 Cap 316 SS/A479
2 3 Label Polyester
3 RL3, R3A—316 SS powdered metal;
4 Lock nut
3 RL4, R4—316 SS/A276
4 5 Spring S17700 SS/AMS 5678
6 Sleeve 304 SS/A240
RL3 5
only 4 7 Spring support
RL3, R3A—316 SS powdered metal;
RL4, R4—316 SS/A276
6 8 Bonnet 316 SS/A479
7 5
9 O-ring Fluorocarbon FKM
13
19
200 200
150 psig (10.3 bar) 150 psig (10.3 bar) 12
12
150 150
100 psig (6.8 bar) 100 psig (6.8 bar)
8 8
100 100
50 psig (3.4 bar) 50 psig (3.4 bar)
4 4
50 50
0 0 0 0
0 2 4 6 8 10 12 14 16 18 20 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Air Flow, std ft3/min Water Flow, U.S. gal/min
5000 350
4500 psig (301 bar)
4800
4500 psig (301 bar)
320
4500
4400 300
4000
4000 280
3500 psig (240 bar)
0 2 4 6 8 10 12 14 16 18 20 250
Air Flow, std ft3/min 3500
0 0.04 0.08 0.12 0.16 0.20 0.24 0.28
250
Inlet Pressure, bar
3500
3500
Set Pressure
3000 2600 psig (179 bar) 200 3000 2600 psig (179 bar)
200
2500 2500
2000 psig (137 bar) 150
2000 psig (137 bar) 150
2000
2000
1500 100
1000 psig (68.9 bar) 1500 100
1000 1000 psig (68.9 bar)
0 10 20 30 40 50 60 70 80 90 100
1000
Air Flow, std ft3/min 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28
Water Flow, U.S. gal/min
R3A R3A
Air Flow, std L/min R4 Water Flow, L/min R4
0 500 1000 1500 2000 2500 0 1 2 3 4 5 6 7
800 800
50 50
700 700
Inlet Pressure, psig
Set Pressure
550 psig (37.8 bar) Set Pressure
600 600 550 psig (37.8 bar)
40 40
500 500
350 psig (24.1 bar)
30 30
400 400 350 psig (24.1 bar)
Dimensions
Dimensions, in inches (millimeters), are Low-Pressure Valves (RL3 and RL4 Series)
for reference only and are subject to
change. End Connections Dimensions, in. (mm)
Ordering
Inlet/Outlet Size Number A B C D E H
RL3 series: 0.19 in. (4.8 mm) fully open orifice
1/4 in. SS-RL3S4
Swagelok 1.44 4.14
6 mm SS-RL3S6MM
0.06 in. tube fittings (36.6) (105)
(1.5 mm) 8 mm SS-RL3S8MM 1.60
lock wire (40.6)
hole Male NPT/
Swagelok 1/4 in. SS-RL3M4-S4 2.70 0.43 4.09
A (68.6) (10.9) (104)
max tube fitting
0.09 in. Male NPT/ 1.19 3.89
(2.2 mm) 1/4 in. SS-RL3M4-F4 (30.2) (98.8)
lock wire
E female NPT 1.17
max
hole Male ISO/ (29.7)
1/4 in. SS-RL3M4F4-RT
female ISO➀
RL4 series: 0.25 in. (6.4 mm) fully open orifice
1.72 5.81
1/2 in. SS-RL4S8
Swagelok (43.7) (148)
tube fittings 1.83 5.92
Outlet B 12 mm SS-RL4S12MM
(46.5) (150)
4.09 0.50 5.37
Inlet Male NPT/ (104) (12.7) (136)
1.72
Swagelok 1/2 in. SS-RL4M8S8
1.43 (43.7) 5.52
tube fitting
(36.3) (140)
D C Male NPT/ 1.43
1/2 in. SS-RL4M8F8
female NPT (36.3)
Applications
Special features
Standard Features
Bourdon Tube Pressure Gauge Model 232.50
Design
ASME B40.100 & EN 837-1
Temperature error
Sizes Additional error when temperature changes from reference
2½”, 4”, 4½” & 6” (63, 100, 115 and 160 mm) temperature of 68°F (20°C) ±0.4% for every 18°F (10°C) rising
or falling. Percentage of span.
Accuracy class
2½”: ± 2/1/2% of span (ASME B40.100 Grade A) Weather protection
4”, 4½” & 6”: ± 1.0% of span (ASME B40.100 Grade 1A) Weather tight (NEMA 4X / IP65)
Dimensions
Size
A B C D4 E G H J L M N S T W Weight³
2½” mm 63 54 33 62 9.5 57 Note1 3.6 3 85 75 5 14 0.35 lb. dry
in 2.48 2.13 1.30 2.44 0.37 2.24 0.14 0.12 3.35 2.95 0.20 1/4” 0.55 0.44 lb. filled
4” mm 101 87 49.5 99 15.5 83 30 4.8 3 132 116 5 22 1.32 lb. dry
in 3.98 3.43 1.95 3.90 0.61 3.27 1.18 0.19 0.12 5.20 4.57 0.20 1/2” 0.87 1.98 lb. filled
4½” mm 121 97 49.5 119 15.5 83 30 5 3 148 137 5 22 1.76 lb. dry
in 4.76 3.82 1.95 4.68 0.61 3.27 1.18 0.2 0.12 5.83 5.39 0.20 1/2” 0.87 3.08 lb. filled
6” mm 161 118 49.5² 163.71 15.5 83 50 5.8 3 196 178 5 22 2.42 lb. dry
in 6.34 4.65 1.95² 6.45 0.61 3.27 1.97 0.23 0.12 7.72 7.01 0.20 1/2” 0.87 4.40 lb. filled
¹ Center back mount (CBM)
² Plus 0.63“ ( 16 mm) for pressure ranges > 1,500 psi
³ Weight without optional accessories
4
D (+) 1mm for panel cutout
Ordering information
Pressure gauge model / Nominal size / Scale range / Size of connection / Optional extras required
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
Modifications may take place and materials specified may be replaced by others without prior notice. WIKA Instrument Corporation
1000 Wiegand Boulevard
Lawrenceville, GA 30045
Tel (770) 513-8200 Toll-free 1-888-WIKA-USA
Fax (770) 338-5118
E-Mail info@wika.com
www.wika.com
PARKER VERIFLO
HYDRAULIC REGULATOR
ITEM: HPR‐1,HPR‐2
SS High Pressure
IR4000 Series Regulator Internally
Threadless Design
▼
materials of construction
presents the IR4000 Series internally threadless Wetted
pressure regulator for instrument/analyzer Body . . . . . . . . . . . . . . . . . . . . 316L Stainless Steel,
and semiconductor applications. The internal . . . . . . . . . . . . . . . . . . . . . Hastelloy C-22®, Monel®
Compression Member. . . . . . . . . . . . . . . Inconel®
threadless design minimizes purge times, and
Diaphragm . . . . . . . . . . . . . . . . . . Hastelloy C-22®
reduces carrier and calibration gas usage. The Poppet . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elgiloy®
IR4000's seat materials meet the requirements Poppet Spring . . . . . . . . . . . . . . . . . . . . . Inconel®
Carrier. . . . . . . . . Stainless Steel*, Hastelloy C-22®
for corrosive and/or higher temperature media
Back-up Washer. . . . . . . . . . . . . . Hastelloy C-22®
requirements. Seat. . . . . . . . . . . . . . . . PCTFE, PEEK™ or Vespel®
Back-up O-ring . . . . . . . . Viton®, optional Teflon®
Instrument applications include gas manage- Inlet Screen/Filter. . . . . . . . . . 316L Stainless Steel,
ment systems in petrochemical/refineries and . . . . Hastelloy C-22® (Hastelloy®, Monel® bodies)
process analyzer systems. Semiconductor
Non-Wetted
applications include general purpose gas Cap . . . . . . . . . . . . . . . . . . . . Nickel Plated Brass,
management (Air, Clean Dry Air (CDA), and . . . . . . . . . . . . . . . . . . . . . optional Stainless Steel
Nut . . . . . 316 Stainless Steel, Nickel Plated Brass††
Plant Nitrogen).
Knob (black) . . . . . . . . . . . . . . . . . . . . ABS Plastic
The IR4000 is a high pressure regulator that can
▼
operating conditions
be ordered with a variety of options to meet Maximum inlet . . . . . . . . . . . 4000 psig (276 barg)
a wide range of system design requirements. Outlet. . . 1-10 psig† (.7 barg), 2-30 psig (2 barg),
. . . . . . . . 3-60 psig (4 barg), 4-100 psig (7 barg),
. . . . . 5-250 psig (17 barg), 10-500 psig (35 barg)
Temperature:
PCTFE . . . . . . . . . . . -40°F to 150°F (-40°C to 65°C)
PEEK™ . . . . . . . . . -40°F to 275°F (-40°C to 135°C)
Vespel® . . . . . . . . -40°F to 500°F (-40°C to 260°C)
▼
functional performance
Flow capacity:
Standard. . . . . . . . . . . . . . . . . . . . . . . . . . Cv = .06
Optional . . . . . . . . . . . . . . . . . . . . . . C = .02, .15†
v
............
(SEMI Flow Coefficient Test #F-32-0998 )
internal volume
4.0 cc without fittings
▼
approximate weight
1.5 lbs (.7 kg)
P R E S S U R E R E G U L AT O R S • 2
IR4000 Series
▼
▼
loads the seal to the body without requiring increases cycle life by preventing over
a threaded nozzle or additional seals to stroking of the diaphragm.
atmosphere.
Low internal volume reduces cycle and
▼
Selection of seat materials for media purge time.
▼
▼ ▼
applications.
Standard units can be dome loaded
Meets NACE Standard MR0175.
▼ ▼ ▼ ▼
▼
Fully swept design. Elgiloy® provide superior corrosion resistance
and high repeatability.
Internally threadless seat design
promotes long seat life. ▼ Close tolerances and tight alignment of
moving components minimize hysteresis.
Convoluted, Hastelloy C-22® diaphragm
▼
provides high corrosion resistance and Unique carrier design disperses gas
▼
Dimensional Drawing
4.91
(124.7) Ø2.32
(58.9 mm)
1.38 FLATS
2.68 (34.9 mm)
(68.0 mm)
.75
(19.1 mm) .75
(19.1 mm)
Ø2.00
(50.8 mm)
3 • P R E S S U R E R E G U L AT O R S
IR4000 Series
12
LP HP LP HP
0 VERIFLO
CORPORATION VERIFLO
CORPORATION
0 10 20 30 40
N2 Flow (slpm)
LP
IR4002 .06 CV
70 Porting Code 3P
Por Porting Code 5P
Por
2000 Inlet psig LP HP LP HP
Outlet Pressure (psig)
60
1000 Inlet psig
50
LP VERIFLO
HP LP VERIFLO
HP
250 Inlet psig CORPORATION CORPORATION
40
Porting Code 4P
Por Porting Code 6P
Por
20
10
Gauge Index
0
0 50 100 150 200 250 300 350 400
N2 Flow (slpm)
2P No Gauge Ports
IR4003 0.15 CV
3P One gauge Port
120
100
90
1000 Inlet psig
4PB One Gauge Port
80
5P Two Gauge Ports
70
60
150 Inlet psig 500 Inlet psig
6P Two Gauge Ports
50 250 Inlet psig
40
30
20
10
0
0 100 200 300 400 500 600 700
N2 Flow (slpm)
P R E S S U R E R E G U L AT O R S • 4
IR4000 Series
Ordering Information
IR400 S 4 B
BASIC SERIES 2P CGA#*
Range Outlet Gauge
3P Y/X 320
0 = 1 -10 psig 0 - 30 psig 4P Y/X Y/X 330
1 = 2 - 30 psig 0 - 60 psig 4PB Y/X 350
2 = 3 - 60 psig 0 - 100 psig 5P Y/X Y/X 510
3 = 4 - 100 psig 0 - 200 psig
580
4 = 5 - 250 psig 0 - 400 psig
590
5 = 10 - 500 psig 0 - 600 psig Additional Configurations
Available Upon Request
BODY MATERIAL
S = 316L Stainless Steel OPTIONAL FEATURES (See Notes)
(Hastelloy® & Monel® Available L = Teflon® Back-Up O-Ring
Upon Request) (PCTFE & PEEK™ seat only)
R = Relief Valve (4PB and 5P Only)
FLOW CAPACITY V = Outlet Valve NOVAS44MF(STD)(See Notes)
= .06 Cv (Standard)
1 = .02 Cv Please select ONE or NONE of the following:
2 = .15 Cv (See Range Table) D = Dome Loaded
SEAT MATERIALS G = Tamper Proof
K = PCTFE M = Metal Knob(Black)
P = PEEK™ For optional color knobs consult factory
V = Vespel®
Note: PANEL MOUNT OPTION:
PORTING Order Panel Nut Ring P/N 41900363
as separate line item.
OUTLET GAUGE
See Outlet Gauge under PORT MOUNTING
BASIC SERIES (see above) for standards. B = .75 (19.1) port height w/ .75 (19.1) mounting
(Additional ranges available upon request) hole pattern.
(Additional Port Mounting available on request)
INLET GAUGE
3000 psig std.
400 psig with the 10 psig range PORT STYLE
2000 psig with .15 Cv option 4 = 1/4" NPT Female Standard
Other = (Additional sizes available upon request)
NOTE:
Outlet Valve: Compression End Connection On Outlet
(A-Lok, CPI) Can Be Substituted for NPTF Connection Range Table
Upon Request.
Model Basic Max Inlet PSIG
ORDERING REGULATORS WITHOUT GAUGES Series Cv
Example #1 .02 .15
.06
IR4003SK2P4B (No X required for gauges,
inlet & outlet ports only) IR4000 400 400 400
Example #2 IR4001 4000 4000 1250
IR4003SK3PX4B (One X for gauge port)
Example #3 IR4002 4000 4000 1250
IR4003SK4PBX4B (One X for gauge port) IR4003 4000 4000 1250
Example #4
IR4004 4000 4000 1250
IR4003SK4PXX4B (Two X's for gauge ports)
IR4005 4000 4000 1250
* Do not exceed the rated pressure of the CGA connection
Hastelloy C-22® is a registered trademark of Haynes International, Inc.
PEEK™ is a trademark of Victrex plc.
Inconel® and Monel® are registered trademarks of Inco Alloys International.
Elgiloy® is a registered trademark of Elgiloy Company.
Viton® is a registered trademark of DuPont Dow Elastomers.
Teflon® is a registered trademark of DuPont Company.
5 • P R E S S U R E R E G U L AT O R S
SEETHRU
LEVEL GAUGE
ITEM: LG‐2880‐1,LG‐2880‐2
PARKER ‐ FCH OLEAR
BLADDER ACCUMULATOR
ITEM: ACC1, ACC2, ACC3
ASME
Bladder Accumulators
207 bar to 420 bar range
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar
4
Design Features and Benefits 2
2
C 1 D
1 Shell 3
3
Forged seamless chrome molybdenum steel, designed and
5
manufactured to ASME VIII Division 1‘U’ coded.
1
2 Label
With assembly specification and installation details.
3 Material Certification
Available on request for all major pressure loaded parts to EN A
10204 3.1
4 Finish
One coat primer paint as standard. Special paints available. 3
2
5 Bladder
Totally enclosed construction with an extensive range of B
1
elastomers available. See Bladder datasheet for further
6 1
details.
2
7
6 Fluid Port Assembly E
Integral high-flow port and poppet valve assembly with an 4
4
anti-extrusion ring. For options see page 3.
3
5
7 Safety
8 SECTION A-A
All gas-loaded accumulators are pressurised vessels and
SCALE 1 : 5
it is recommended that safety consideration be given to 9
the application in which they are used. A relief valve should
always be fitted to the hydraulic system with the option of a
UNLESS OTHERWISE SPECIFIED:
A
FINISH:
Bladder Kit comprising:
DEBUR AND
TOLERANCES:
Servicing data sheet for information regarding installation of
LINEAR:
ANGULAR:
D1 Bladder
accumulators. NAME SIGNATURE DATE TITLE:
DRAWN D2 Gas valve assembly
CHK'D
2 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
HY10-4009-DS/UK ASME Bladder Accumulators
How to Order Bladder Accumulators 207, 310, 345 & 420 bar
Design Standard/
Code Bladder Stem/Gas Valve Code Authority Approval
OB-OF 01-37L 54L 4 ASME VIII - ‘U’ coded
OA 5/8” UNF/1/4” BSPM 7/8” UNF/1/4” BSPM M50 x 1.5 / 1.4” BSPM CE mark of ASME
9A 5/8” UNF/302-32 7/8” UNF/302-32 7/8” UNF / 302-32 accumulators possible,
SA as OA but corrosive please contact us
service
Example: 5400A-00-204
Litres: 54
Bladder Material: Nitrile Standard
Bladder Stem/ Gas Valve: 5/8” UNF/1/4” BSPM
Shell & Fluid Port: Oil Service
Maximum working pressure: 207 bar
Design Number/Approval: ASME VIII - ‘U’ coded
3 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar
B STEM
C A/F
D
F G
E F
DETAIL A
SCALE 1 : 2 HEAD DETAIL 54/57L
DEBUR AND
D
UNLESS OTHERWISE SPECIFIED: FINISH:
DO NOT SCALE DRAWING REVISION
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP
SURFACE FINISH: EDGES
TOLERANCES:
LINEAR:
ANGULAR:
CHK'D
APPV'D
MFG P (A/F)
E
TYPICAL ACC FOR WEB BROCHURE GAS END N
Q.A MATERIAL:
A4 DWG NO.
(A/F)
F WEIGHT: 48.42 SCALE:1:10 SHEET 1 OF 1
H M
L
J
K
4 Parker Hannifin
DETAIL B Accumulator Cooler Division Europe
SCALE 1 : 2
Sandycroft, UK
UNLESS OTHERWISE SPECIFIED: FINISH: DEBUR AND
DO NOT SCALE DRAWING REVISION
UNLESS OTHERWISE SPECIFIED: FINISH: DEBUR AND
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP
DO NOT SCALE DRAWING
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP REVISION
SURFACE FINISH: EDGES
SURFACE FINISH: EDGES
TOLERANCES: TOLERANCES:
LINEAR:
ANGULAR: LINEAR:
NAME SIGNATURE DATE
ANGULAR:
TITLE:
DRAWN
CHK'D
NAME SIGNATURE DATE TITLE:
APPV'D
DRAWN
MFG
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar
Accessories
A wide range of accessories are available for our accumulator range. Please refer to our accessories catalogue to find the suitable
items for your accumulator.
Accessories include:
• Charging Sets
• Safety Blocks
• Brackets and Clamps
Accumula
Accessorietors
2
s
07 bar to 6
90 bar ran
ge
5 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
Parker Worldwide
Europe, Middle East, Africa HU – Hungary, Budaoers North America
Tel: +36 23 885 470
AE – United Arab Emirates, parker.hungary@parker.com CA – Canada, Milton, Ontario
Dubai Tel: +1 905 693 3000
Tel: +971 4 8127100 IE – Ireland, Dublin
Tel: +353 (0)1 466 6370 US – USA, Cleveland
parker.me@parker.com
parker.ireland@parker.com (industrial)
AT – Austria, Wiener Neustadt Tel: +1 216 896 3000
Tel: +43 (0)2622 23501-0 IT – Italy, Corsico (MI)
Tel: +39 02 45 19 21 US – USA, Elk Grove Village
parker.austria@parker.com
parker.italy@parker.com (mobile)
AT – Eastern Europe, Wiener Tel: +1 847 258 6200
Neustadt KZ – Kazakhstan, Almaty
Tel: +43 (0)2622 23501 900 Tel: +7 7273 561 000 Asia Pacific
parker.easteurope@parker.com parker.easteurope@parker.com
AU – Australia, Castle Hill
AZ – Azerbaijan, Baku NL – The Netherlands, Oldenzaal Tel: +61 (0)2-9634 7777
Tel: +994 50 22 33 458 Tel: +31 (0)541 585 000
parker.azerbaijan@parker.com parker.nl@parker.com CN – China, Shanghai
Tel: +86 21 2899 5000
BE/LU – Belgium, Nivelles NO – Norway, Asker
Tel: +32 (0)67 280 900 Tel: +47 66 75 34 00 HK – Hong Kong
parker.belgium@parker.com parker.norway@parker.com Tel: +852 2428 8008
BG – Bulgaria, Sofia PL – Poland, Warsaw ID – Indonesia, Tangerang
Tel: +359 2 980 1344 Tel: +48 (0)22 573 24 00 Tel: +62 21 7588 1906
parker.bulgaria@parker.com parker.poland@parker.com IN – India, Mumbai
BY – Belarus, Minsk PT – Portugal, Leca da Palmeira Tel: +91 22 6513 7081-85
Tel: +375 17 209 9399 Tel: +351 22 999 7360 JP – Japan, Fujisawa
parker.belarus@parker.com parker.portugal@parker.com Tel: +81 (0)4 6635 3050
CH – Switzerland, Etoy RO – Romania, Bucharest KR – South Korea, Seoul
Tel: +41 (0)21 821 87 00 Tel: +40 21 252 1382 Tel: +82 2 559 0400
parker.switzerland@parker.com parker.romania@parker.com
MY – Malaysia, Shah Alam
CZ – Czech Republic, Klecany RU – Russia, Moscow Tel: +60 3 7849 0800
Tel: +420 284 083 111 Tel: +7 495 645-2156
parker.czechrepublic@parker.com parker.russia@parker.com NZ – New Zealand, Mt Wellington
Tel: +64 9 574 1744
DE – Germany, Kaarst SE – Sweden, Spånga
Tel: +49 (0)2131 4016 0 Tel: +46 (0)8 59 79 50 00 SG – Singapore
parker.germany@parker.com parker.sweden@parker.com Tel: +65 6887 6300
DK – Denmark, Ballerup SK – Slovakia, Banská Bystrica TH – Thailand, Bangkok
Tel: +45 43 56 04 00 Tel: +421 484 162 252 Tel: +662 717 8140
parker.denmark@parker.com parker.slovakia@parker.com TW – Taiwan, New Taipei City
ES – Spain, Madrid SL – Slovenia, Novo Mesto Tel: +886 2 2298 8987
Tel: +34 902 330 001 Tel: +386 7 337 6650 VN – Vietnam, Ho Chi Minh City
parker.spain@parker.com parker.slovenia@parker.com Tel: +84 8 3999 1600
FI – Finland, Vantaa TR – Turkey, Istanbul
Tel: +358 (0)20 753 2500 Tel: +90 216 4997081
parker.turkey@parker.com
South America
parker.finland@parker.com
AR – Argentina, Buenos Aires
FR – France, Contamine s/Arve UA – Ukraine, Kiev
Tel: +54 3327 44 4129
Tel: +33 (0)4 50 25 80 25 Tel +380 44 494 2731
parker.france@parker.com parker.ukraine@parker.com BR – Brazil, Cachoeirinha RS
Tel: +55 51 3470 9144
Ed. 2013-08-01
© 2013 Parker Hannifin Corporation. All rights reserved. HY10-2009-DS/UK, POD, 08/2013, ZZ
www.protectoseal.com
Specifications Series 670 / 6670
End-of-Line Deflagration Flame Arrester
E,N
DIMENSIONS (NOTE: Dimensions shown are for reference only, contact Factory for certified drawings.)
Connection Ht Dia B.C Dia. Holes Type
Cat. No.* FNPT ANSI** DIN 16 PN A C D E N Approval
671 1" 1- 1- 12.88" (73mm) 13.38" (86mm) - - - UL
671F - 11" 1- 14.4" (112mm) 13.38" (86mm) 3.13" (80mm) .63" (16mm) 4 UL
See Series 670E - 1- 1DN 25 1- 1- - - - Note 1
6672 2" 1- 1- 14.63" (117mm) 16.13" (156mm) - - - UL
6672F - 12" 1- 17"(178mm) 16.13" (156mm) 4.75" (120mm) .75" (19mm) 4 UL
See Series 670E - -- 1DN 50 1- 1- - - - Note 1
673B 3" 1- 1- 18" (203mm) 17.5" (191mm) - - - -
673BF - 13" 1- 19.88" (251mm) 17.5" (191mm) 6" (152mm) .75" (19mm) 4 -
See Series 670E - 1- 1DN 80 1- 1- - - - Note 1
674 4" 1- 1- 17.38" (187mm) 18.5" (216mm) - - - -
674F - 14" 1- 19.38" (238mm) 18.5" (216mm) 7.5" (190mm) .75" (19mm) 8 -
See Series 670E - 1- 1DN 100 1- 1- - - - Note 1
* Cat. No. designates all Aluminum construction, please refer to chart on reverse for other materials.
** Aluminum flanged to mate with 125# ANSI FF flanges. 316 S,S. models mate with 150# ANSI RF flanges.
Note 1: Type Approved according to ATEX Directive 94/9/EC, Standards EN 12874 and ISO 16852 (Refer to Protectoseal Series 670E)
For larger sizes. . . Refer to Protectoseal Series No. 860 or Series No. 670E
Type Approved according to End-of-Line Deflagration Flame Pipe-Away Pressure Vacuum Combination Pressure / Vacuum
ATEX Directive 94/9/EC, Arrester provides protection of Relief Vent for applications that Relief Vent & Flame Arrester
Standards EN 12874 and ISO the tank’s vapor space if an require hazardous vapors be provides pressure and vacuum
16852. Suitable for use with ignition source is introduced out- processed into manifolded relief as well as protection from
NEC Groups C or D side of the tank. Suitable for piping and not released into the propagation of externally intro-
(IEC Groups IIB3 or IIA). NEC Group D (IEC Group IIA) atmosphere. duced flames. Suitable for NEC
vapors. Group D (IEC Group IIA) vapors.
PROTECTOSEAL
Safety Without Compromise
®
225 Foster Ave., Bensenville, IL 60106-1690
P 630.595.0800 F 630.595.8059
info@protectoseal.com www.protectoseal.com
2 WAYS MANIFOLD
ITEM2: NV1, MNV1
Global Presence for
Peace of Mind
Through 360º
Low Power
316L Stainless Steel Solenoid
Housing and Valve High Flow
Standard Solenoids
Worldwide Approval
Registered
Solenoid Operator is Free to Rotate 360º Solenoid operator and mounting block (patent
pending) are free to rotate 360º allowing for an easy
cable layout and ease of connection wiring. Solenoid
internals rotate with operator and prevent cables
being pulled out of terminal block.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
2 www.bifold.co.uk contact a member of our sales team.
Slimline Solenoids
Registered
Worldwide Approvals.
Solenoid Operator is Free to Rotate 360º Solenoid operator is free to rotate 360º allowing for
an easy cable layout and ease of connection wiring.
Solenoid internals rotate with operator and prevent
cables being pulled out of terminal block.
Compact Enclosure Design No time penalty for heat dissipation before removing
solenoid cover.
Coil Leads
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
State of the Art Testing The standard solenoid operator is a holding magnet
type which ensures the valve will operate in damp
conditions. The risk of corrosion to internal
components is reduced, unlike other valve types that
incorporate a solenoid core tube design with a
'wetted' armature that will only operate in dry air
conditions!
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
4 www.bifold.co.uk contact a member of our sales team.
Selection Table
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Selection Table
SCHEMATIC 3/2 NU
½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Auto Reset.
1
19 FP12P-S1-08-32-NU-V-77A-24D-120 ATEX II 2 GD, Ex d IIC T6
2
3 IECEx Ex d IIC T6
12 Watt, Cv 2.5, 10 bar.
FP12P
SCHEMATIC 3/2 NU
R ½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Manual Reset.
19 FP12P-S1-08-32-NU-V-77A-24D-ML-65
1
2 ATEX II 2 GD, Ex d IIC T6
3 IECEx Ex d IIC T6
6.5 Watt, Cv 2.5, 10 bar.
FP12P
Manual Reset
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
6 www.bifold.co.uk contact a member of our sales team.
Selection Table
20
3
ATEX II 2 GD, Ex d IIC T6
2 SJ06-EI-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1 3.0 Watt, Cv 0.7, 10 bar.
SJ06
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
SJ06-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 0.7, 10 bar.
†
21
3
2
ATEX II 2 GD, Ex d IIC T6
S12-E1-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
3.0 Watt, Cv 1.7, 10 bar.
1
S12
ATEX II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
S12-E1-32-NC-00-78A-370
370 Ohms, Cv 1.7, 10 bar. †
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Selection Table
21
3 ATEX II 2 GD, Ex d IIC T6
2
S12-E5-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 1.7, 10 bar.
S12
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
S12-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 1.7, 10 bar.
22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E1-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E1-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 3.0, 10 bar.
22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E5-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
Manual Reset
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E5-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 3.0, 10 bar. †
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
8 www.bifold.co.uk contact a member of our sales team.
Overview
Materials of Construction
Solenoid housing and valve manufactured from 316L stainless steel as standard.
Valve seals are supplied in Viton as standard. Alternative elastomers available for extreme conditions and to suit media.
Springs are manufactured from 302S26 & 316S42 stainless steel as standard.
Fasteners are metric A4 18/10 grade stainless steel; equivalent to 316L grade stainless steel.
Technical Data
Operating Performance for FP03P, FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR
Duty cycle 100% continuously rated/energised.
Surge suppression diode is fitted on all Ex d dc solenoid coils as standard.
Response times - pull in <100ms, drop out <70ms.
Solenoid Insulation - Class H.
Pull-in volts to 85% of nominal. (Checked at FAT to be within specified limits to guarantee safety factors).
Maximum volts at 110% of nominal.
Drop-out volts typically 10 - 20% of nominal (higher Volt options for line monitoring). (Checked at FAT to be within
specified limits to guarantee safety factors).
Temperature rating -20ºC to upper limit of solenoid classification (standard). Arctic service option to -60ºC.
IP66 & IP67 Ingress Protection to IEC 60529 and NEMA 4X.
Bifold solenoid valves must be installed, operated and maintained in accordance with the relevant Bifold installation, operating
and maintenance instructions, relevant installation rules, regulations and codes of practice.
Product Options
Certification & Approval options available Certification & Approval options available
for standard 7 series solenoid housing for slimline 5 series solenoid housing
SIL 3, Safety Integrity Level, third party certification to IEC 61508 (Valve models FP03P, FP06P & FP10P. Note: FP03P fitted as
the pilot stage operator on SJ06, S06, S09, S12 & SPR).
Valves can be mounted in any orientation. Solenoids can be rotated relative to the pilot stage valve body to suit cable entry.
Working pressure up to 35 bar. Maximum working pressure according to valve model.
Operating media - Filtered lubricated or unlubricated air, inert gas, sweet (natural) and sour gas options, water,
water glycol mixtures and mineral oil. Maximum viscosity 65 cSt (mm²/s).
For operating temperature range, please see solenoid valve type and seal options.
Higher voltage options available for line monitoring.
Manual Reset, Manual Override and Manual Latch operator options.
Arctic Service options to -60ºC.
These products can be incorporated within our 'AXIS' valve actuator control manifold systems.
See catalogue 03: - AXIS Manifold System.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Certification Details
Certification & Approval Details
Type 74 Solenoid
ATEX, Certificate Number Baseefa 09ATEX0040X. IECEx, Certificate Number IECEx Bas 09.0012X.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +40ºC. Ex emb IIC T3 Gb Tamb -25ºC to +40ºC.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +55ºC. Ex emb IIC T3 Gb Tamb -25ºC to +55ºC.
Dual Labelled/Marked
Type 77 Solenoid
ATEX, Certificate Number Baseefa 10ATEX0026. IECEx, Certificate Number IECEx Bas 10.0008.
II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC). Ex d IIC T6 (Tamb -60ºC to +40ºC).
II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC). Ex d IIC T5 (Tamb -60ºC to +55ºC).
II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC). Ex d IIC T4 (Tamb -60ºC to +90ºC).
Dual Labelled/Marked
Type 58 Solenoid
ATEX, Certificate Number Baseefa 08ATEX0292X. IECEx, Certificate Number IECEx Bas 08.0095X.
II 1G Ex ia IIC T6 Ga (-40ºC ≤ Ta ≤ +60ºC). Ex ia IIB T6 Ga (-40ºC ≤ Ta ≤ +60ºC).
Dual Labelled/Marked
Type 78 Solenoid
ATEX, Certificate Number Baseefa 02ATEX0124X. IECEx, Certificate Number IECEx Bas 09.0092X.
II I GD Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC). Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC).
II I GD Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC). Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC).
Dual Labelled/Marked
Type 77 Solenoid Type 77 Solenoid
CSA (US), Certificate Number 1398692 ATEX, Certificate Number Baseefa 10ATEX0026.
Class 1, Division 1, Groups B, C & D for both II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC).
Canada & USA. II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC).
Ex d IIC for Canada, AEx d IIC for USA.
T85ºC -60ºC to +40ºC ambient. II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC).
T100ºC -60ºC to +55ºC ambient.
T135ºC -60ºC to +90ºC ambient.
Dual Labelled/Marked
Type 58 Solenoid Type 58 Solenoid
INMETRO, Certificate Number CEPEL 12.2125X. GOST, Certificate Number B0015, RTN Permit
BR-Ex ia IIB T6 -40ºC to +60ºC ambient. Number PPC 00-048112
0Ex ia IIC T6 -40ºC to +40ºC ambient.
Type 77 Solenoid 0Ex ia IIC T5 -40ºC to +55ºC ambient.
INMETRO, Certificate Number CEPEL-EX-097/2003X. 0Ex ia IIC T4 -40ºC to +60ºC ambient.
BR-Ex d IIC T6 -60ºC to +40ºC ambient. Type 77 Solenoid
BR-Ex d IIC T5 -60ºC to +55ºC ambient. GOST, Certificate Number B00763, RTN.
BR-Ex d IIC T4 -60ºC to +90ºC ambient. Ex d IIC T6 -60ºC to +40ºC ambient.
Ex d IIC T5 -60ºC to +55ºC ambient.
Type 78 Solenoid Ex d IIC T4 -60ºC to +90ºC ambient.
INMETRO, Certificate Number CEPEL-EX-532/05.
Type 78 Solenoid
BR-Ex ia IIC T6 -60ºC to + 40ºC ambient.
GOST, Certificate Number B00015, RTN.
BR-Ex ia IIC T4 -60ºC to + 95ºC ambient.
Permit Number PPC 00-28504.
Ex ia IIC T6 -60ºC to +40ºC ambient.
Type 87 Solenoid Ex ia IIC T5 -60ºC to +55ºC ambient.
NEPSI, Certificate Number GYJ081011. Ex ia IIC T4 -60ºC to +90ºC ambient.
Ex d IIC T6 up to 40ºC ambient. Type 77 & 78 Solenoid
Ex d IIC T5 up to 55ºC ambient.
Ex d IIC T4 up to 95ºC ambient. GOST K, GGTN K Permit, Kazakhstan,
BIF 7727 2.
Label Rationalisation
The temperature details on our solenoid labels have, to date, been These are in the process of being replaced with a single label which
laid out with a single ambient range and 'T' rating, as follows :- covers all potential temperature parameters.Therefore the label
will for example, read as follows :-
{
77A3 - T4 (-60ºC ≤ Tamb ≤ +90ºC) T4 (-60ºC ≤ Tamb ≤ +90ºC) {
or 77A6 - T5 (-60ºC ≤ Tamb ≤ +55ºC) 77A T5 (-60ºC ≤ Tamb ≤ +55ºC)
or 77A9 - T6 (-60ºC ≤ Tamb ≤ +40ºC) T6 (-60ºC ≤ Tamb ≤ +40ºC)
Please note that operation ambients are dependant upon seal types.
For solenoid type 87 please note that the solenoid housing is fixed.
For solenoid type 74 the maximum permissible ambient temperature is subject to the coil wattage. Please see page 12.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
10 www.bifold.co.uk contact a member of our sales team.
Port Connections
Port Connections for
Port Connections (FP03P Only) (FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR)
PORT CONNECTIONS TABLE PORT CONNECTIONS TABLE
Configuration Pressure Service Vent Configuration Pressure Service Vent
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Ex emb Options
Options Table 1 74 (Ex emb)
SOLENOID OPTIONS TABLE 1 74 (Ex emb)
Solenoid Typical Power Cable
Product Standard CV Temperature Ingress
Order Apparatus Consumption Entry Certification Options
Type Voltage Rate Range (ºC) Protection
Code Code (W) Connection
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 -25ºC to +55ºC
24 Vdc IP66 M20 x 1.5
Ex emb II Ambient
74 0.1 -25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
T3 -25ºC to +55ºC (T3) NEMA 4X Option)
48 Vdc Media #
-20ºC to +40ºC
3.6 -25ºC to +40ºC
FP03P Ambient
-25ºC to +40ºC (T3)
3.6 0.4
24 Vdc Media #
-20ºC to +40ºC IP66 M20 x 1.5
4.4 0.5 -25ºC to +40ºC IP67 (½" NPT ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
Ex emb II 6.8 0.75
FP06P
74 T3
3.6 0.4 Media #
24 Vdc -20ºC to +40ºC M20 x 1.5
IP66
-25ºC to +40ºC (½" NPT
4.4 0.5 IP67 ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
6.8 0.75
FP10P
Media #
-20ºC to +40ºC
-25ºC to +40ºC
1.8 -20ºC to +55ºC
0.7 -25ºC to +55ºC
24 Vdc Ambient IP66 M20 x 1.5
-25ºC to +40ºC (T3) IP67 (½" NPT
-25ºC to +55ºC (T3) ATEX IECEx
Media # NEMA 4X Option)
48 Vdc
-20ºC to +40ºC
3.6 0.7 -25ºC to +40ºC
SJ06 Ambient
Ex emb II -25ºC to +40ºC (T3)
74 T3 Media #
-20ºC to +40ºC
1.0 (S06) -25ºC to +40ºC
1.8 -20ºC to +55ºC
1.7 (S09) -25ºC to +55ºC
24 Vdc Ambient M20 x 1.5
1.7 (S12) IP66
-25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
-25ºC to +55ºC (T3)
NEMA 4X Option)
48 Vdc 1.0 (S06) Media #
-20ºC to +40ºC
3.6 1.7 (S09) -25ºC to +40ºC
S06, S09 & S12 Ambient
1.7 (S12) -25ºC to +40ºC (T3)
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 3.0 -25ºC to +55ºC
24 Vdc
Ex emb II Ambient
74 -25ºC to +40ºC (T3) IP66 M20 x 1.5
T3 -25ºC to +55ºC (T3)
IP67 (½" NPT ATEX IECEx
48 Vdc
NEMA 4X Option)
SPR Media #
3.0 -20ºC to +40ºC
3.6 -25ºC to +40ºC
Ambient
-25ºC to +40ºC (T3)
Ex d Options
Options Table 2 77 (Ex d)
SOLENOID OPTIONS TABLE 2 77 (Ex d)
Solenoid Typical Power Temperature Cable
Product Standard CV Ingress
Order Apparatus Consumption Range (ºC) Entry Certification Options
Type Voltage Rate Protection
Code * Code (W) Media Ambient Connection
12 Vdc ATEX IECEx
Media #
24 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ex d IIC 110 Vdc
77 0.1 IP67 (½" NPT GOST K GGTN
T6, T5 Ambient
Option)
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4)
*
FP03P PESO
12 Vdc Media # ATEX IECEx
24 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) GOST
110 Vdc IP66 M20 x 1.5
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5)
Ex d IIC * NEPSI
FP06P 50 or 60 Hz -60ºC to +90ºC (T4)
77 T6, T5 PESO
or T4 ATEX IECEx
24 Vdc Media #
48 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
110Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
FP10P PESO
For detailed information on certification please see page 10. * For China (NEPSI), please note that the solenoid operator is Type 87.
Other wattages available upon request. ~ Non standard low power option.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Ex ia Options
Options Table 3 58 & 78 (Ex ia)
Solenoid
Typical Cable
Product Order CV Temperature Ingress
Apparatus Entry Certification Options
Type Code Rate Range Protection
Code Connection
Media #
-20ºC to +95ºC
-60ºC to +95ºC ATEX IECEx
Ex ia IIC IP66 M20 x 1.5 INMETRO
58 † 0.5
T6 Ambient GOST
-40ºC to +60ºC
FP06P
Media #
-20ºC to +95ºC
IP66 M20 x 1.5 ATEX IECEx
-60ºC to +95ºC
Ex ia IIC IP67 (½" NPT INMETRO
78 † T6 or T4 0.1 Ambient NEMA 4X Option) GOST
-60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
FP03P
Media #
-20ºC to +95ºC ATEX IECEx
-60ºC to +95ºC IP66 M20 x 1.5 INMETRO
78 † Ex ia IIC IP67 (½" NPT
0.7 GOST
T6 or T4 Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
-60ºC to +95ºC (T4)
SJ06
Media #
-20ºC to +95ºC ATEX IECEx
1.0 (S06) -60ºC to +95ºC IP66 M20 x 1.5
Ex ia IIC INMETRO
78 † 1.7 (S09) IP67 (½" NPT
T6 or T4 Ambient GOST
NEMA 4X Option)
1.7 (S12) -60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
S06, S09 & S12
Media #
-20ºC to +95ºC ATEX IECEx
IP66 M20 x 1.5
Ex ia IIC -60ºC to +95ºC INMETRO
3.0 IP67 (½" NPT
78 † T6 or T4 GOST
Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
SPR -60ºC to +95ºC (T4)
FP03P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NC Wiring Diagrams
34 50 74 SOLENOID
(EExemb)
TYPE ‘M’ RED +
OVERRIDE
WINDING
OPTION 1
2
BLACK -
3
WINDING
SCHEMATIC 2/2 NC
M20 x 1.5P SOLENOID
CASE
CABLE ENTRY
180.1
AC VOLTAGE
155.4
EXTERNAL 77 SOLENOID
EARTH STUD (EExd)
1
124.6
2
CONNECTIONS AREBI-POLAR
3 WINDING
SOLENOID
CASE
1
50.5
MOUNTING POSITIONS RED + BLACK -
2 x Ø5.5 THRO' HOLES 2
37.1
26.2
DC VOLTAGE
3
25
78 SOLENOID
= =
Normally Closed (EExia)
28 5 function. (Plugs
RED +
38.1 q available as a line
item). BLACK -
FP06P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NU
34 50
SCHEMATIC 2/2 NC
M20 x 1.5P Valve suitable for
CABLE ENTRY
Universal operation
2/2 & 3/2.
191
1
166.5
3
Plug port 3 for 2/2
1
Normally Closed
SCHEMATIC 2/2 NO function. (Plugs
MOUNTING POSITIONS
61.5
3
item).
33.5
33.5
22
17.5
FP06P
Dimensional Drawing
SCHEMATIC 3/2 NU
NU Normally
Universal offered
187.5
1
2 as standard.
3
MOUNTING HOLES Ø5,5 THRO'
PORT 1
PORT 2
46.5
PORT 3
33.5
33.5
17.5
22
16 25.4
32
58(Ex ia)
A ATEX/IECEx Dual Certified/Labelled
G GOST
I INMETRO
Solenoid Approval
N NEPSI x
U CSA (US) ATEX Dual Certified/Labelled x
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary Options
FP10P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5
34 50
NU Normally
TYPE ‘M’
OVERRIDE
Universal offered
OPTION 1 as standard.
2
3
SCHEMATIC 2/2 NC
Valve suitable for
M20 x 1.05P Universal operation
CABLE ENTRY
2/2 & 3/2.
Normally Open and
191
1
2
166.5
Normally Closed
1 SCHEMATIC 2/2 NO function. (Plugs
2 available as a line
MOUNTING POSITIONS
61.5
2 x M6 x 9.5 DP item).
47.8
46.5
3
Plug port 1 for 2/2
35.9
20.8
17.8
1 Normally Open
2 function. (Plugs
= =
44.45 q
3 available as a line
Body Ported Shown item).
FP12P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5
34 50
SCHEMATIC 2/2 NC
M20 x 1.5P
CONDUIT ENTRY Valve suitable for
universal operation
EXTERNAL
2/2 & 3/2.
225.5
EARTH STUD
1 Normally Open and
200.8
2
MOUNTING POSITIONS
Normally Closed.
170
2 x M6 x 10 DP
3
Plug port 3 for 2/2
1 Normally Closed
SCHEMATIC 2/2 NO function. (Plugs
96
2
available as a line
67
61
3
item).
43.8
26.5
19.5
Plug port 1 for 2/2
1 Normally Open
27.8 8.5
2 function. (Plugs
44.45 q 3 available as a line
102.8
item).
SJ06
Dimensional Drawing
68 86.5
SCHEMATIC 3/2 NC
34 50
TYPE ‘M’ T
OVERRIDE
OPTION
3
2
M20 x 1.5P 1
CABLE ENTRY EXTERNAL
EARTH STUD
19
221.3
MOUNTING POSITIONS
2 x Ø5.5 THRO' HOLES
196.6
SCHEMATIC 3/2 NO
165.8
=
28
=
T
VIEW OF DETAIL 'A'
1/8" NPT 31.4
PILOT VENT
DETAIL A
59.5
1 2 3
3
2
15
38.1 31.4
48 1
93.5
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
32 3-way, 2-position
NC Normally closed Valve Configuration
NO Normally open
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13- Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
68 86.5
50
T
34
TYPE ‘M’
OVERRIDE
OPTION
3
2
MOUNTING POSITIONS
3 x Ø5.2 THRO' HOLES SCHEMATIC 3/2 NO
187.9
157.1
=
38
T
=
52.2
DETAIL A 1 2 3
3
36.3 2
50.8 52.2
67.4
125.3 1
SPR
Dimensional Drawing
86.5 180
50 155.4
124.6
SCHEMATIC 3/2 NU
TYPE ‘M’
OVERRIDE
OPTION
EXTERNAL
M20 x 1.5P
162.2
2 x M5 x 9 DP
84.7
77.7
1
61.2
1
44.7
37.7
= =
24
38.1 96.5
DETAIL A
Options
Product Options
The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Options
Product Options for Type 58
The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.
The solenoid valve switches on and off with the electrical supply. The manual override button can be pressed to operate the
valve when the solenoid is in the electrically de-energised position. The manual override is non-detented, i.e. does not latch
in position. When the button is released, the valve spring returns.
For Type ML, apply the electrical signal and press the reset button. The valve moves to the energised position and will not
de-energise until the electrical supply is removed. The manual reset button also acts as a manual override, when the valve is
in the de-energised position and the electrical supply is off. The manual reset is non-detented, spring return, i.e. does not latch
in position.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
24 www.bifold.co.uk contact a member of our sales team.
Solenoid Valves
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
26 www.bifold.co.uk contact a member of our sales team.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.
Selection Table
INSTRUMENTATION PRODUCTS - NEEDLE VALVES (Up to and including 10,000 psi / 690 bar)
Schematic Page
Product Product Code Product Description
Representation Number
¼”NPT, Single Isolate, Needle configuration,
NV0104F02M5V6K
6,000 psi / 414 bar
8”NPT, Single Isolate, Needle configuration,
3
NV0106F02M5V6K
6,000 psi / 414 bar
½”NPT, Single Isolate, Needle configuration,
NV0108F02M5V6K
10 6,000 psi / 414 bar
¼”NPT, Single Isolate, Needle configuration,
NV0104F02M5V10K
10,000 psi / 690 bar
8”NPT, Single Isolate, Needle configuration,
3
NV01 NV0106F02M5V10K
10,000 psi / 690 bar
Single Isolate
½”NPT, Single Isolate, Needle configuration,
NV0108F02M5V10K
10,000 psi / 690 bar
¼”NPT,Block & Bleed Manifold,Needle -
NV0304F02M5V6K
CaptiveVent Plug configuration,6,000 psi / 414 bar
½”NPT,Block & Bleed Manifold,Needle -
NV0308F02M5V6K
CaptiveVent Plug configuration,6,000 psi / 414 bar
11
¼”NPT,Block & Bleed Manifold,Needle -
NV0304F02M5V10K
CaptiveVent Plug configuration,10,000 psi / 690 bar
NV03
Block & Bleed ½”NPT,Block & Bleed Manifold,Needle -
Manifold NV0308F02M5V10K
CaptiveVent Plug configuration,10,000 psi / 690 bar
¼”NPT, Block & Bleed Manifold, Needle -
NV0404F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
½”NPT, Block & Bleed Manifold, Needle -
NV0408F04F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
12
¼”NPT, Block & Bleed Manifold, Needle -
NV0404F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
NV04 ½”NPT, Block & Bleed Manifold, Needle -
Block & Bleed
NV0408F04F02M5V10K Needle configuration, 10,000 psi / 690 bar,
Manifold
¼” Vent Bleed
THIS PRODUCT DESIGN IS UNIQUE TO BIFOLD AND PATENTED
¼”NPT, DBB Manifold, Needle - Needle -
NV0504F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
½”NPT, DBB Manifold, Needle - Needle -
NV0508F04F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
13
¼”NPT, DBB Manifold, Needle - Needle -
NV0504F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
NV05
½”NPT, DBB Manifold, Needle - Needle -
Double Block &
Bleed Manifold
NV0508F04F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
THIS PRODUCT DESIGN IS UNIQUE TO BIFOLD AND PATENTED
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated Quality Assurance
so to ensure accurate and up-to-date information please All Bifold products are manufactured to a most stringent
refer to the product catalogue issue list on our web site or QA programme. Every care is taken at all stages of
contact a member of our sales team. is a member of the
4
manufacture to ensure that every product will give optimum
www.bifold.co.uk When selecting a product, the applicable operating system
performance and reliability. We are third party certified to
EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing
function, material compatibility, adequate ratings, correct total traceability are available on request, to BSEN 10204.3.1.B
installation, operation, and maintenance are the where available. We reserve the right to make changes of companies
responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
BFD01/5 August '10 C Bifold 2010
Instrument, Process,
Directional Control Valves,
and Pumps
Pneumatic and
Instrumentation Valves
Hydraulic Valves
Subsea Valves
Hydraulic Pumps,
Intensifiers and Valves
Quality Assurance
All Bifold products are manufactured to a most stringent
Accuracy of Information QA programme. Every care is taken at all stages of
We take care to ensure that product information in this manufacture to ensure that every product will give When selecting a product, the applicable operating
catalogue is reasonably accurate and up-to-date. However, optimum performance and reliability. We are third system design must be considered to ensure safe use.
our products are continually developed and updated so to party certified to BS EN ISO 9001:2008. Functional test The products function, material compatibility, adequate
ensure accurate and up-to-date information please refer to certificate, letter of conformity and copies of original mill ratings, correct installation, operation, and maintenance
the product catalogue issue list on our web site or contact certificates, providing total traceability are available on are the responsibilities of the system designer and user.
a member of our sales team. request to BS EN 10204 3.1 where available. We reserve
the right to make changes to the specifications and
design etc., without prior notice.
CHECK VALVE
ITEM2: CV1, CV2, MCV1, MCV3
NEEDLE VALVE
ITEM3: NV2, MNV2, MNV3
DBB VALVE
ITEM4: DBB
Product Data Sheet LP Type Ball Valve
Standard Specification
Pressure: 1000psi Seals: PTFE Seats: PTFE/PVDF
Temp: 120 deg C (PTFE/PVDF) Thread form: NPT Handle: Lever
Ordering Code
(Typical example) → LPB1F 50 S
Type
LPB – low pressure ball valve
1 – 1000PSI
3 – 3000PSI
F - female
25 - 1/4"
38 - 3/8”
50 - 1/2"
75 - 3/4”
10 - 1”
Material
Oliver Valves Ltd, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX. United Kingdom.
T: +44 (0)1565 632636 E: sales@valves.co.uk. W: www.valves.co.uk
© Oliver Valves Ltd 2010
Oliver Valves Limited, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX, England
Telephone: 01565 632636 Fax: 01565 654089 Email: sales@valves.co.uk www.valves.co.uk
Standard Specification
Pressure: 10,000psi Seals: PTFE Seats: PTFE/KEL-F
Temp: 200 deg C Thread form: NPT Handle: Lever
Ordering Code
(Typical example) → B10FX 50 S / BT / FS
Type
B10 = Ball valve 10,000 psi
F = Female x Female
X = 10mm bore
25 - 1/4"
38 - 3/8”
50 - 1/2”
Material
BT - BSP Taper
BP - BSP Parallel (top sealing)
SW - Socket Weld
Options
Copyright 2005 Oliver Valves Ltd. All rights reserved. E&OE. Rev. 1.0
Product Data Sheet Check Valve
Key features
Rev 1.1
Oliver Valves Ltd, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX. United Kingdom.
T: +44 (0)1565 632636 E: sales@valves.co.uk. W: www.valves.co.uk
© Oliver Valves Ltd 2009
Oliver Valves Limited, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX, England
Telephone: 01565 632636 Fax: 01565 654089 Email: sales@valves.co.uk www.valves.co.uk
Standard Specification
Pressure: 6000psi Packing: PTFE Handle: T-Bar Bore: 0.21” (5.4mm)
Temp: 240 deg C Thread form: NPT Seat: Metal to metal CV: 0.46
Ordering Code
(Typical example) → F 50 S / BT / AT
Type
Female x Female
Size
25 - 1/4" 75 - 3/4"
38 - 3/8” 10 - 1”
50 - 1/2"
Material
BT - BSP Taper
BP - BSP Parallel (top sealing)
SW - Socket Weld
Options
Copyright 2005 Oliver Valves Ltd. All rights reserved. E&OE. Rev. 1.0
BIS
RELIEF VALVE
ITEM1: PSV‐2880A, PSV‐2880B, PSV‐2880AB, PSV‐2880C, PSV‐2880D,
PSV‐2880CD
RELIEF VALVE (H.P.) TYPES: RL25, RL37
PRESSURE EQUIPMENT DIRECTIVE (PED) 97/23/EC APPROVED.
STAINLESS STEEL (316 / 1.4404) Valves Ltd
SUITABLE FOR LIQUID USE.
ALL DIMENSIONS IN INCHES.
OUTLET
Circuit Symbol
1.35
INLET
1.48
(Across Flats)
ORDERING
TECHNICAL SPECIFICATION EXAMPLE
Valve Type: RL25 RL37 RL25
6.70 Adjustable
pressure 1,000 psi. (70 Bar).
(threaded) for M6 bolts 1.54"
SQ. Fixing Centres
(Ø1.80" recommended
Locking Screw and Washer clearance hole for panel
(can be removed when mounting)
5.45
mounting valve to a panel)
2.00
Circuit Symbol
1.20
INLET
ORDERING
TECHNICAL SPECIFICATION EXAMPLE
Valve Type: RL50 RL50
WATER PUMPS
The picture indicates the
Type TW
small size of a typical motor
Type SW
pump unit based on the SW
pump. One assembly offers
1.5 lpm at 207 bars with 1,500
rpm. The other offers 0.3 lpm
at 690 bars with 500 rpm.
Pipes should be of sufficient size to give not more than Both assemblies are driven by
3.70 m/sec velocity in the delivery line and 1.20 m/sec in a 0.75 Kw 24v DC powered
the suction line. The suction line should be kept under flameproof rated motor.
positive pressure when the pump is stationary to allow
priming.
We recommend that the fluid reservoir should be between Material and weight
50 mm and 3 m above the suction port. 316 stainless steel, 19Kg
Drawing
Dimensions in mm
http://www.marshalsea.co.uk/typesw.html 03/04/2013
Type XW water glycol pump . . . Marshalsea Hydraulics Page 1 of 2
Drawing
http://www.marshalsea.co.uk/typexw.html 03/04/2013
Type XW water glycol pump . . . Marshalsea Hydraulics Page 2 of 2
http://www.marshalsea.co.uk/typexw.html 03/04/2013
COMMERCIAL
MOTOR DRIVEN PUMP
ITEM1: PBE‐2883
LARZEP
MANUAL HAND PUMP
ITEM1: PBE‐2881, PBE‐2882
LARZEP
MANUAL HAND PUMP
ITEM1: DPI‐2882‐1, DPI‐2881‐1, DPI‐2883‐1, DPI‐2884‐1
BULLETIN NO. 120/02
(Supersedes 120/01)
Mid-West
Instrument
®
*Product of the Switching Voltage & Current shall not exceed power rating of the device.
**Except where otherwise noted.
***B, C, & D options are available, however they are not identified in Electrical
Specifications. (Recommend using E, F, or G)
➁ MATERIAL
A. Aluminum Body, S.S. Piston (Standard)
D.
F.
Mounting Holes in Gauge Body for Field Mounting of Electrical Configurations Options L & M
Pipe Mounting Kit (Carbon Steel) (Not available w/C or D Electrical Switch Options)
L. Liquid Fill (Not available w/follower pointer) (Not available with 3-1/2" dial)
M. Monel Body (See 120 ABM) (5000 P.S.I.G. working pressure)
M. Maximum Indicator Follower Pointer
N. Aluminum Bronze Body (See 120 ABM) (5000 P.S.I.G. working pressure)
T. Oxygen Cleaning
S. 316 S.S. Body & S.S. Piston (Standard)
U. S.S. Tag Mounted w/S.S. Wire
Z. SPECIAL (Uncoded Options)
V. S.S. Tag Mounted w/S.S. Screws
➂ DIAL TYPE
A. 2-1/2” Round Uni-Directional Engrd. Plastic Housing Assy. (Standard)
W.
X.
Wall Mounting Kit
Individual Gauge Packaging
Z. Special (Uncoded Options)
B. 2-1/2” Round Bi-Directional Engrd. Plastic Housing Assy.
C. 4-1/2” Round Uni-Directional Engrd. Plastic Housing Assy.
D. 4-1/2” Round Bi-Directional Engrd. Plastic Housing Assy.
E. 3-1/2” Round Uni-Directional Anod. Aluminum Housing Assy.
F. 3-1/2” Round Bi-Directional Anod. Aluminum Housing Assy.
G. 4-1/2” Round Uni-Directional Anod. Aluminum Housing Assy.
5. Ethylene Propylene
6. Perfluoroelastomer K. Two (2) Switches in Explosion Proof Enclosure with Glass Window Cover and C.S.A. & U.L. Listing (2)
9. Special (Uncoded Options) L. One (1) Switch in STD. Enclosure with Plug-In Connector (DIN 43650/IP65-PG11)
*Viton® is a Registered Trademark of DuPont Dow Elastomers. M. Two (2) Switches in STD. Enclosure with Plug-In Connector (DIN 43650/IP65-PG11)
**Teflon® is a Registered Trademark of DuPont. Z. Special (Uncoded Options)
(1)
Complete Assembly Rated Class I, Div. II, Groups A, B, C, & D; Class II, Div. II, Groups F and G.
(2)
Complete Assembly Rated Class I, Div. I, Groups C & D; Class II, Div. I, Groups E, F, & G.
(3)
5000 PSIG Working Pressure.
➄ CONNECTIONS
(NOTE: Models 120M and 120N available only with end connections)
0.
2.
1/4" FNPT Back Connections (Standard)
1/4" FNPT End Connections
➇ ELECTRICAL SPECIFICATIONS (For Resistive Loads)
A. S.P.D.T., 3W, 0.25 Amp., 125 VAC/VDC (Standard) (Switch adjustable range of 10-90%)
6. 7/16" - 20 Str. Thd. O-Ring Port (Back Connections) E. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC (Normally Open) (Switch adjustable range of 25-95%)
7. 1/2" FNPT Stainless Steel Adaptors F. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC (Normally Closed)
8. 1/2" FNPT Monel Adaptors (Switch adjustable range of 25-95%)
9. Special (Uncoded Options) G. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC One (1) Normally Open, One (1) Normally Closed (4)
H. S.P.D.T., 60W, 1.0 Amp., 240 VAC/VDC (Switch adjustable range of 25-100%)
Z. Special (Uncoded Options)
(4)
Available with Electrical Configurations B, D, F, H, K and M only.
NOTE: NOT ALL OPTIONS AVAILABLE IN COMBINATION WITH OTHER OPTIONS.
NOTE: FACTORY PRESET SWITCHES AT NO CHARGE (SPECIFY SETTING)
NOTE: THE USE OF DIAPHRAGM SEALS IS NOT RECOMMENDED FOR MODEL 120 SERIES GAUGE.
ATTEMPTS TO INSTALL SUCH SEALS ON THIS GAUGE WILL VOID THE WARRANTY.
MOUNTING INFORMATION & DIMENSIONAL DATA
MODEL 120: 2-1/2" INCH PLASTIC DIAL ASSY.
Mid-West
Instrument
®
R E P R E S E N T E D B Y:
Printed in U.S.A.
PARKER
SPIN‐ON FILTER
ITEM1: HF1, HF2
HYDRAULIC FILTER
ITEM2: HF3
12AT/50AT Series
Spin-On Filters
1
Spin-On Filters
12AT/50AT Series
Applications for
Spin-On Filters
Mounting Ports
n 6 hole pattern n Both NPT and
n Mobile Equipment
for flexibility SAE straight
n Hydrostatic Drives thread available
TYPICAL
RETURN
LOCATIONS
RETURN
SUCTION
BREATHER
OFFLINE
20B 25C
.70 12AT ASSEMBLY 03C 10C 25C
.70 50AT-1 ASSEMBLY 03C 10B 10C
10 10
(BAR)
8 8
.50 .50
PRESSURE DROP
PRESSURE DROP
.40 6 .40 6
.30 .30
4 4
.20 .20
(PSI)
(PSI)
2 2
.10 .10
0 0
.0 0 2 4 6 8 10 12 14 16 18 .0 0 5 10 15 20 25 30 35 40 45 50
(BAR)
8 8
.50 .50
PRESSURE DROP
PRESSURE DROP
.40 6 .40 6
.30 .30
4 4
.20 .20
(PSI)
(PSI)
2 2
.10 .10
0 0
.0 0 2 4 6 8 10 12 14 16 18 .0 0 5 10 15 20 25 30 35 40 45 50
LI LO
67.82
MAX
2.67
95.00
3.74
38.10
1.50
RI RO
INLET OUTLET
12.19
.48
172.97MAX
6.81
148.84
5.68
15.7 MINIMUM
.62 REMOVAL
CLEARANCE
10 .4
12AT
DIFFERENTIAL PRESSURE (IN H20)
8
DIFFERENTIAL PRESSURE (PSI)
.3
7
6
12AT
5
.2
4
50AT
3
50AT
.1
2
0
0 10 20 30 40 50 60 70 80 90 100 0 100 200 300 400 500 600
A. Shut down the main system and 25C 925023 926170 N/A
release pressure in the filter line. 10C 921999 926169 927736
B. Unthread the canister and discard 03C 926543 926541 N/A
it along with the accompanying 20B 928764 928767 929446
seal. A strap wrench may be
10B 928763 928766 929445
required.
C. Apply a small amount of lubricant 03B N/A 934200 932073
to the new canister seal.
D. Install the new canister and hand
tighten.
15 15
10
20
10
1.0
20
1.0
12-30 PSI
COLOR BAND (RED) 20-30 PSI
1.5 0.5 1.5 COLOR BAND (RED)
0.5
25
25
5
5
2.0 2.0
bar bar
psi psi
30
30
How To Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
50AT 2 10C N 25 DD N
155
High Pressure Filters
12S Series
Features/Applications
■ Offshore – High pressure and aggressive environment
■ DI Water – Water fogging
■ Food Processing – Caustic washdown (poultry, etc.)
■ Test Stands – High pressure
Dimensions
BURST TEST
PROOF TEST ON FILTER HOUSING
30000
20000
SINGLE LENGTH:
15000 8.09 (205.49) LUBRICATE O-RING
TORQUE BOWL TO
DOUBLE LENGTH: 75 ± 10 FT-LBS
11.80 (299.72)
10000
5000
0
OPTIONAL DRAIN PLUG
TORQUE SPECIFICATIONS:
TIME 1.00 SAE-4: 18-20 FT-LB
(25.4) 1/4 M/P: 20-25 FT-LB
INLET
.75 INLET
(19.05)
4.25 DIA. REF
I
I
.75
(19.05)
1.50
(38.1)
OPTIONAL
VISUAL/
ELECTRICAL
INDICATOR
(2 PLACES)
O
OUTLET OUTLET
10Q
05Q
2Q 5Q
6
80
1000 99.9 5
10Q
60
4
200 99.5
20Q
100 99.0 3
20Q
40
2
20 95.0 02Q
20
1
2 50.0 0 0
0 1 2 3 4 5 6
Grams
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 10 gpm to 100 psid terminal - 5mg/L BUGL
25 25
150SUS HOUSINGS SAE-10
1.5 3/4 M/P
1.5
20 20
SAE-8
15 1.0
15 1.0
BAR
02Q
PSID
PSID
BAR
05Q 10Q
10 10
20Q
0.5 SAE-12 0.5
5 5
1 NPTF
0 0.0 0 0.0
0 5 10 15 20 0 5 10 15 20 25
GPM GPM
Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10000 100
05Q
2Q 6
5Q 80
20Q
99.9
02Q
5
10Q
1000
10Q
60
4
200 99.5
100 99.0 3
40
20Q
2
20 95.0
20
1
2 50.0 0 0
0 5 10 15 20
Grams
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 15 gpm to 100 psid terminal - 5mg/L BUGL
SAE-8
15 1.0 15 1.0
PSID
PSID
BAR
BAR
02Q
10 10
05Q
10Q 0.5 SAE-12 0.5
20Q
5 5
1 NPTF
0 0.0 0 0.0
0 5 10 15 20 25 0 5 10 15 20 25
GPM GPM
HOW TO ORDER:
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
12SMP 1 10QH SP MP 6 11
Replacement Elements
Microglass III (Fluorocarbon) Microglass III (Ethylene Propylene -EPR)
Media Single Double 12SMP-1 / 12SHP-1 12SMP-2 / 12SHP-2
20QH 403400 403404 403485 403488
No-Bypass 10QH 403399 403403 403484 403487
05QH 403398 403402 403483 403486
02QH 403397 403401 403482 403417
20QH 937442 937446 937474 937478
Bypass 10QH 937441 937445 937473 937477
05QH 937440 937444 937472 937476
02QH 937439 937443 937471 937475
PRESSURE TRANSMITTER
ITEM2: PT‐2880A‐1, PT‐2880C‐1, PZT‐2880‐1, PZT‐2880‐2, PT‐29XX‐4
<<Contents>> <<Index>>
GS 01C25B01-01E
STANDARD SPECIFICATIONS
SPAN AND RANGE LIMITS
Measurement
Span/Range kPa inH2O(/D1) mbar(/D3) mmH2O(/D4) Square Root Output Accuracy
L
Span 0.1 to 10 0.4 to 40 1 to 100 10 to 1000 The square root accuracy is a percent of flow span.
Range -10 to 10 -40 to 40 -100 to 100 -1000 to 1000
Span 0.5 to 100 2 to 400 5 to 1000 50 to 10000 Output Accuracy
M
Range -100 to 100 -400 to 400 -1000 to 1000 -10000 to 10000
50% or Greater Same as reference accuracy
Span 3.5 to 700 14 to 2800 35 to 7000 0.035 to 7 kgf/cm2
H Reference accuracy50
Range -700 to 700 -2800 to 2800 -7000 to 7000 -7 to 7 kgf/cm2 50% to Dropout point
T01E.EPS Square root output (%)
T00E.EPS
PERFORMANCE SPECIFICATIONS
Ambient Temperature Effects per 28˚C (50˚F)
Zero-based calibrated span, linear output, wetted
Change
parts material code S and silicone oil, unless other-
wise mentioned. Capsule Effect
Specification Conformance M and H (0.04% Span0.009% URL)
EJX series ensures specification conformance to at L (0.1% Span0.05% URL)
least 3.
Reference Accuracy of Calibrated Span Static Pressure Effects per 6.9 MPa (1000 psi)
(includes terminal-based linearity, hysteresis, and Change
repeatability) Span Effects
Measurement span M H
L, M, and H capsules
0.075% of span
Reference X Pressure 0.04% of Span Effect on Zero
accuracy M and H capsules
X Pressure (0.0050.0035 URL/span)% of Span 0.02% of URL
10 kPa 70 kPa L capsule
X (40 inH2O) (10 psi) 0.05% of URL
URL 100 kPa 700 kPa Overpressure Effects
(the upper range limit) (400 inH2O) (100 psi)
Overpressure condition: up to maximum working
T02E.EPS
pressure
Measurement span L M and H capsules
0.03% of URL
Reference X Pressure 0.04% of span
Stability (All normal operating condition, including
accuracy
X Pressure (0.020.04 URL/span)% of span overpressure effects)
M and H capsules
2 kPa
X (8 inH2O) 0.1% of URL per 10 years
URL 10 kPa Power Supply Effects
(the upper range limit) (40 inH2O) 0.005 % per Volt (from 21.6 to 32 V DC, 350 )
T03E.EPS
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec.1, 2003-00
<<Contents>> <<Index>> 3
Working Pressure Limits (Silicone oil) Communication Requirements
Maximum Pressure Limits (Safety approvals may affect electrical require-
ments.)
L Capsule 16 MPa (2300 psi)
BRAIN
M and H Capsule 25 MPa (3600 psi)
Communication Distance
Minimum Pressure Limit Up to 2 km (1.25 miles) when using CEV polyethyl-
See graph below ene-insulated PVC-sheathed cables. Communication
distance varies depending on type of cable used.
100{14.5} Atmospheric
Load Capacitance
pressure 0.22 F or less
Working
pressure Load Inductance
kPa abs
{psi abs} 3.3 mH or less
Applicable range Input Impedance of communicating device
10{1.4}
10 k or more at 2.4 kHz.
2.7{0.38}
HART
Communication Distance
1{0.14} Up to 1.5 km {1 mile} when using multiple twisted pair
-40 0 40 80 120
(-40) (32) (104) (176) (248) cables. Communication distance varies depending on
Process temperature C ( F) type of cable used.
F01E.EPS
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 4
Fill Fluid
Silicone, Fluorinated oil (option)
Weight
[Installation code 7, 8 and 9]
2.7 kg (6.0 lbs) without integral indicator, mounting
bracket, and process connector.
Connections
Refer to “MODEL AND SUFFIX CODE.”
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 5
MODEL AND SUFFIX CODES
Model Suffix Codes Description
EJX110A ························· Differential pressure transmitter
Output Signal -D · · · · · · · · · · · · · · · · · · · · · · · 4 to 20 mA DC with digital communication (BRAIN protocol)
-E · · · · · · · · · · · · · · · · · · · · · · · 4 to 20 mA DC with digital communication (HART protocol)
Measurement L ····················· 0.1 to 10 kPa (0.4 to 40 inH2O)
span (capsule) M····················· 0.5 to 100 kPa (2 to 400 inH2O)
H····················· 3.5 to 700 kPa (14 to 2800 inH2O)
Process connections 0·················· without process connector (Rc1/4 female on the cover flanges)
1·················· with Rc1/4 female process connector
2·················· with Rc1/2 female process connector
3· · · · · · · · · · · · · · · · · · with 1/4 NPT female process connector
4· · · · · · · · · · · · · · · · · · with 1/2 NPT female process connector
5· · · · · · · · · · · · · · · · · · without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material J · · · · · · · · · · · · · · · · ASTM-B7M carbon steel
G················ 316 SST (ISO A4-70) stainless steel
C················ ASTM grade 660 stainless steel
Installation -7 · · · · · · · · · · · · · · Vertical piping, left side high pressure, and process connection downside
-8 · · · · · · · · · · · · · · Horizontal piping and right side high pressure
-9 · · · · · · · · · · · · · · Horizontal piping and left side high pressure
Amplifier housing 1············ Cast alluminum alloy
Electrical connection 0··········· G1/2 female, one electrical connection without blind plugs
2··········· 1/2 NPT female, one electrical connection without blind plugs
4··········· M20 female, one electrical connection without blind plugs
5··········· G1/2 female, two electrical connections and a blind plug
7··········· 1/2 NPT female, two electrical connections and a blind plug
9··········· M20 female, two electrical connections and a blind plug
Integral indicator D········ Digital indicator
E········ Digital indicator with the range setting switch
N········ None
Mounting bracket B ····· 304 SST 2-inch pipe mounting (flat type)
D ····· 304 SST 2-inch pipe mounting (L type)
N ····· None
T04E.EPS
Contact Yokogawa representative for the suffix codes indicated as ‘-’.
The “” marks indicate the most typical selection for each specification.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
316 SST material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 6
OPTIONAL SPECIFICATIONS (For Explosion Protected type)
Item Description Code
FM Explosionproof Approval *1
Explosionproof for Class I, Division 1, Groups B, C and D
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G –
Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
Factory Mutual (FM)
FM Intrinsically safe Approval *1
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1 Hazardous Locations. –
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups E, F & G, and Class III, Division 1 Hazardous Locations.
Combined FF1 and FS1 *1 –
ATEX (KEMA) Flameproof Approval *1
–
II 2G EExd IIC T4, T5, T6
ATEX ATEX (KEMA) Intrinsically safe Approval *1
II 1G EEx ia IIC T4 –
Combined KF2, KS2 and Type n *1
Type n: II 3G EEx nL IIC T4 –
CSA Explosionproof Approval *1
Explosionproof for Class I, Division 1, Groups B, C and D –
Canadian Standards Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Association (CSA)
CSA Intrinsically safe Approval *1
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x –
Combined CF1 and CS1 *1 –
T05E.EPS
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 3, 7, and 9.
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 7
OPTIONAL SPECIFICATION
Item Description Code
Terminal cover only P
Color change
Painting Both sides of amplifier covers, Munsell 7.5 R4/14 PR
Coating change Anti-corrosion coating X2
Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically
Lightning protector safe type.) A
Allowable current: Max. 6000 A ( 140 s ), Repeating 1000 A ( 140 s ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Degrease cleansing treatment K1
Oil-prohibited use*1 Degrease cleansing treatment and with fluorinated oilfilled capsule.
Operating temperature 20 to 80 C( -4 to 176 F) K2
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 8
DIMENSIONS
Model EJX110A
Vertical Impulse Piping Type
Process connector upside (INSTALLATION CODE '7')
Unit : mm (approx.inch)
(0.23)
240(9.45)
6
177(6.97) 110(4.33)
(2.13)
97 129 12
54
(3.82) (5.08) (0.47) 39
(1.54) 2-inch pipe
(O.D. 60.5 mm)
Electrical connection
Mounting bracket for code 5 and 9. Vent/drain
(2.05)
(L-type, Optional)
52
plugs
Vent/drain plugs Conduit
connection
223(9.17)
97(3.82)
ø69(2.72)
ø77(3.03)
95(3.74)
138(5.43)
(1.61)
(2.64)
41
67
Internal
Zero indicator
adjustment (Optional)
Ground High 54
Low
Process connector terminal pressure (2.13) pressure
(Optional) side side
F03E.EPS
Horizontal Impulse Piping Type (INSTALLATION CODE '9') (For CODE '8', refer to the notes below.)
54 89(3.50) 67(2.64) Conduit 110 (4.33)
6 connection Zero
adjustment 12
95(3.74) (0.47) 39
Integral (1.54)
Indicator
ø77(3.03)
(optional)
(2.72)
ø69
(5.75)
Electrical connection
146
177(6.97)
(5.08)
129
Ground
terminal
Vent plug
Drain plug
Process
(4.88)
Low
124
connection
41 High pressure
(1.61) pressure side
side
115
(4.53)
(1.85)
47
Mounting bracket
2-inch pipe
(Flat-type, optional) (O.D. 60.5mm)
54
(2.13)
117
(4.61)
* 1: When Installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 9
+
CHECK – External indicator(ammeter) terminal*1
Ground terminal
E
PULS
SUP
PLY
K
CHEC M
ALAR
*1: When using an external indicator or a check meter,
the internal resistance must be 10 or less.
CHECK +
SUPPLY +
F05E.EPS
SUPPLY - CHECK -
All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 10
MACIS
FLOW CONTROL VALVE
ITEM1: MFCV
VOLUME BOTTLE
ITEM2: MVB
PRESSURE RELIEF
ITEM5: MPRV
70
,62
&HUW1R&,,(
2+6$6
&HUW1R&,6
0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
)/2:&21752/9$/9(6 36,
7<3(0$&,69$/9(
,1
287
7:2:$<
)/2:&21752/9$/9(6
,1 287
137
137
00
25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(
2ULILFH6L]H
%RG\6KDSH +H[DJRQ $)00
9DOYH6HDW0DW O 6WDQGDUG 6WDLQOHVV6WHHO±686
9DOYH6HDW0DW O 2SWLRQV 2WKHUPDWHULDOVZLOOEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW
6HDO0DWHULDO 6WDQGDUG2ULQJ
'U\:HLJKW NJ
:RUNLQJ7HPSHUDWXUH5DQJH &WR&
)ORZ5DWH &Y
0$&,63WH/WG %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO )D[ (PDLOVDOHV#PDFLVFRPVJ :HEVLWHZZZPDFLVFRPVJ
70
,62
&HUW1R&,,(
2+6$6
&HUW1R&,6
0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
$,56725$*(7$1. 36, 7:2:$< 12
7<3(0$&,69$/9($67
200
137
,1
,1 287
00
7:2:$<
1250$//<23(1
$,56725$*(7$1.
287
25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(
2ULILFH6L]H
,QWHUQDO6WRUDJH&DSDFLW\ OLWHU
9DOYH6HDW0DW O 6WDQGDUG 6WDLQOHVV6WHHO686
9DOYH6HDW0DW O 2SWLRQV 2WKHUPDWHULDOVFDQEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW
6HDO0DWHULDO 6WDQGDUG2ULQJ
'U\:HLJKW NJ
:RUNLQJ7HPSHUDWXUH5DQJH &WR&
0$&,63WH/WG %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO )D[ (PDLOVDOHV#PDFLVFRPVJ :HEVLWHZZZPDFLVFRPVJ
TM
/
MOUNTING HOLE (O7.0MM)
EX
1/4-18NPT
PILOT
OUT
87MM
1/4-18NPT
11MM OUT
EX
IN
IN
55.5MM
51.9MM
NORMALLY CLOSED
PILOT OPERATER VALVES
39MM
39MM
26.3MM
22.6MM
ORDERING
TECHNICAL SPECIFICATION EXAMPLE
MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
TM
PANEL NUT
/
Panel Hole Size Required:O22.5mm
1/8NPT
PIOLT
PILOT
OUT
(132.5MM)
SUPPLY
EX
(126.5MM)
(NC)
(118MM)
EX
3/8NPT
OUT
3-WAY 2-POSITION
(38.5MM) 3/8NPT
NORMALLY CLOSED
(57.5MM)
IN
3/8NPT
(20MM)
ORDERING
TECHNICAL SPECIFICATION EXAMPLE
MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
TM
PANEL NUT
/
Panel Hole Size Required:O22.5mm
1/8NPT
PIOLT
PILOT
SUPPLY OUT
(132.5MM)
(126.5MM)
EX (NC)
EX
(118MM)
1/4NPT
IN
1/4NPT
(20MM)
ORDERING
TECHNICAL SPECIFICATION EXAMPLE
MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
70
,62
&HUW1R&,,(
2+6$6
&HUW1R&,6
0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
5(/,()9$/9(6 36, 7:2:$< 1&
7<3(0$&,69$/9(...
35(6685(6(77,1*187
287
00
137
00
287 ,1
00 7:2:$<
1250$//<&/26('
5(/,()9$/9(6
,1
137
25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(
2ULILFH6L]H PP
9DOYH6HDW0DW O 6WDQGDUG 6WDLQOHVV6WHHO±686
9DOYH6HDW0DW O 2SWLRQV 2WKHUPDWHULDOVZLOOEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW
6HDO0DWHULDO 6WDQGDUG2ULQJDQG&HUDPLF%DOO
'U\:HLJKW NJ
:RUNLQJ7HPSHUDWXUH5DQJH &WR&
g/HDNWLJKWZKHQRI³VHWSUHVVXUH´LVDSSOLHG
g5HSHDWDELOLW\ fRI³VHWSUHVVXUH´
g5HVHDWLQJZLWKLQRI³FUDFNLQJSUHVVXUH´6WDWHGHWDLOVZKHQRUGHULQJ
0$&,63WH/WG %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO )D[ (PDLOVDOHV#PDFLVFRPVJ :HEVLWHZZZPDFLVFRPVJ
RSTAHL
START PUSHBUTTON
ITEM1: HS‐2880A‐1A, HS‐2880B‐1A, HS‐2880C‐1A, HS‐2880D‐1A, HS‐
2883‐1A, HS‐SCSSV‐0, HS‐SCSSV‐C, HS‐SSV‐O, HS‐SSV‐C, HS‐WV‐O, HS‐
WV‐C, HS‐LGV‐O, HS‐LGV‐C
STOP PUSHBUTTON
ITEM2: HS‐2880A‐1B/G, HS‐2880B‐1B/G, HS‐2880C‐1B/G, HS‐2880D‐
1B/G, HS‐2883‐1B/G
LAMP INDICATOR
ITEM3: XA‐2880A‐1, XA‐2880B‐1, XA‐2880C‐1, XA‐2880D‐1, XA‐2883‐1,
XA‐2800‐1
corrosive locations.
• Installation is easy and
precise.
• Devices fit into a standard
30.5mm, 1.2" knock-out.
• Tightening the retainer nut
makes installation complete.
• Available with cage clamp
terminals or leads
for easy connection.
E
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
8003 PUSHBUTTONS AND CONTROL SWITCHES
Technical Data
Enclosure Material Polyamide
8003/1••
II 2 D IP66 T80°C
Class III Enclosure Type 3 ,4, 4X, 12, 13
FEATURES
The 8003 pushbutton and control switch series
are typically mounted in an electrical panel or
enclosure, for custom control applications.
They come with different actuators, contact
arrangements and connection options as
indicated on pages E2, E3 and E4.
E1
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
1123
Ordering Information
PUSHBUTTONS
1224
Connection
Options
11 21
12 22
13 23
Actuator
Options
With Cage Clamps & Cap With Cage Clamps With Cap & 20' Lead 14 24
Descriptions C A T A L O G N U M B E R Contacts
Mushroom
Pushbutton 8003/111-012 8003/112-012 8003/113-012-6 NC/NO
Maintained Black
with Red Legend 8003/121-012 8003/122-012 8003/123-012-6 NC/NC
Disk
1.5" (38mm) O.D. 8003/131-012 8003/132-012 8003/133-012-6 NO/NO
Maintained action.
Turn-to-Release.➁
Mushroom
Pushbutton Black
8003/111-003 8003/112-003 8003/113-003-6 NC/NO
1 .5" (38mm) O.D.
Momentary action.
8003/121-003 8003/122-003 8003/123-003-6 NC/NC
With black snap-in
legend disk.➁
8003/131-003 8003/132-003 8003/133-003-6 NO/NO
E2
➁Other legend disks must be ordered separately. See Page E7.
CATALOG CATALOG
CONTACT ARRANGEMENTS CONTACT ARRANGEMENTS
maintained maintained
maintained maintained
maintained maintained
spring return spring return
maintained maintained
maintained maintained
maintained
1 2
1 3
With Cage Clamps & Cap With Cage Clamps With Cap & 20' Lead
E3
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
CATALOG CATALOG
CONTACT ARRANGEMENTS CONTACT ARRANGEMENTS
Special:
Non-removable key positions need to be specified.
Non-lockable Pad-lockable Key Operated Other key types than MS 1 available.
E4
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
Technical Data
8013/3 LED PILOT LIGHTS
I max 150 mA
8013/312 PTB 02 ATEX 2130U
P max 1W
Li 0
Ci 0
For I. S. version 8013/32•
CLASSIFICATIONS
* UL applied for
of Use with Cap & Lead 8013/1•3 (without Cap)
Class I, Zone 1 Enclosure Type➀ 1, 2, 3, 3R, 4, 4X, 12, 13 Enclosure AEx e, Ex e
II 2G EEx md ia IIC (T6)
8013/321 & 8013/323 PTB 02 ATEX 2131X
Class I, Div. 1, I.S. Type 1, 2, 3, 3R, 4, 4X, 12, 13
FEATURES:
The 8013/3 Series of Pilot Lights are avail-
➀Terminate in “Increased Safety” Enclosure.
Ordering Information
ages between 12V up to 254V AC/DC.
The types 8013/32•-al are for connection
with intrinsically safe circuits only and oper-
ate safely within the values stated in the
above table “Intrinsic Safety Ratings Entity
Connection
Parameters”.
Options
E5
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
Technical Data
ENCLOSURE
Material - Enclosure Polyamide
Material - Bezel Polyamide
Colors red, amber, green, blue and white
* Class III
Contact Switching Capacity AC – A600 (600V AC, 10A) Knockout for 8018
* UL applied for
DC – 110V Max. 1 Amp Max.
LED PILOT LIGHT
II 2 G EEx dm IIC T6
*For lower energy use gold plated contacts, available on request.
II 2 D IP66 T80°C
Enclosure Type Rating For Installation PTB 02 ATEX 2129X
IP66 depending on enclosure
Ordering Information
Description Wire Connections CATALOG NUMBER
8018/3113-al-6 FEATURES:
Illuminated
Pushbutton
E6
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
ACCESSORIES AND SPARE PARTS
Ordering Information
DESIGNATION ILLUSTRATION DESCRIPTION CATALOG NUMBER
Spare For all key-operated buttons/
Keys key-operated switches
Standard version MS 1 3746050
Special key, specify number 3746060
E7
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
DIMENSIONS
Standard Knock-out Distance for Standard Knock-out Distance Knock-out Distance for Aligning Several
Jumbo E-STOP Button with / without Legend Frame devices with O.D. 1.49"(38mm) in a Panel
(8003/1••-015 Mushroom Maintained)
E8
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
8415 LED PILOT LIGHT ASSEMBLY
Technical Data
Mechanical/Electrical Life 105 Output Hours
Ci 0
II 2G EEx de IIC
Enclosure/Lens Material Polyamide
drawing 80 106 01 31 3.
Recommended Barrier:
9002/13-252-121-041.
E9
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
Single contact
block, 1 NC
CLASSIFICATIONS for Contact
Class III
II 2 G EEx de IIC
Enclosure Type Rating For Installation PTB 00 ATEX 1031 U
PTB 01 ATEX 1129 U
FEATURES:
Area Classification
Pushbutton 8703
Ordering Information
PUSHBUTTON
CATALOG NUMBER
CONTACTS
1 NC 8703/01 - ❐❐ -9
1 NO 8703/02 - ❐❐ -9
1 NC / 1 NO 8703/12 - ❐❐ -9
2 NC 8703/11 - ❐❐ -9
2 NO
Knockout for 8703
8703/22 - ❐❐ -9
Fill out the blanks in the Catalog Number with the information found on
pages F7 or F8 in the column “ACTUATOR CODE” (actuator code 23 not
possible).
E10
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
NOTES Notes
E11
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
> As pendant light fitting or side
entry lamp
> Version with 1 or 2 lamps:
18 W, 36 W and 58 W E2
> Central locking
> All-pole disconnection by means
of an N/C switch when the lamp
is opened E2
> End of life switch 1 and 2
(only 6000)
E2
E2
www.stahl.de
E2
Series EXLUX 6000 / 6400 E2
00280E00
E2
The lights of the Series EXLUX 6000 and EXLUX 6400 can be used
for normal lighting but also for an emergency light which is supplied
with current via a group or a central system.
E2
ATEX / IECEx / GOST NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
E2
EXLUX 6000 x x x x EXLUX 6000 x x EXLUX 6000 x x x x x
For use in: For use in: For use in:
EXLUX 6400 x*) x*) x*) EXLUX 6400 x EXLUX 6400 x x x x x
For use in: For use in: For use in:
*) ATEX E2
E2
E2
E2
WebCode 6000A
E2
2012-06-19·EK00·III·en Lighting E2/1
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
Selection Table
Version Lamp wattage Number of lamps Electronic ballast Order number Weight
W kg
Light Fittings for Fluo- 18 1 1 channel EB 6000/521-8..1-013. 4.500
rescent Lamps (Zone
2 2 channel EB 6000/522-9..1-013. 6.800
1) Series 6000
36 1 1 channel EB 6000/541-8..1-013. 7.300
2 2 channel EB 6000/542-9..1-013. 9.100
01968E00
58 1 1 channel EB 6000/561-8..1-013. 10.200
2 2 channel EB 6000/562-9..1-013. 10.800
Side entry lamp (Zone 18 1 1 channel EB 6000/821-8081-0130 6.200
1) Series 6000
2 2 channel EB 6000/822-9081-6130 8.000
36 1 1 channel EB 6000/841-8081-0130 9.600
2 2 channel EB 6000/842-9081-0130 9.600
01962E00
01968E00
58 1 1 channel EB 6400/561-8..0-213. 8.700
2 2x 1 channel EB 6400/562-9..0-213. 8.800
Side entry lamp (Zo- 18 2 2 channel EB 6400/822-9080-6130 6.300
nes 2, 21, 22) Series
36 2 1 channel EB 6400/841-8080-0130 9.100
6400
01962E00
Technical Data
Electrical data
E2
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Rated voltage
Electronic ballast AC: 220 (- 10%) ... 240 (+ 10%) V, 50 / 60 Hz
EB with extended
DC: 198 ... 254 V/ 1 lamp: 176 ... 264 V
6000/...-....-4... (18 and 36 W lamps) E2
voltage range AC: 110 (- 10%) ... 240 (+ 10%) V, 50 / 60 Hz
DC: 104 ... 264 V
6000/...-....-8... (17, 32 and 40 W NEC lamps)
AC: 120 (- 10%) ... 277 (+ 10%) V, 50 / 60 Hz
DC: 113 ... 294 V
Nominal operational for lights of the versions for lights of the versions E2
current IEC 60081 18 W 36 W 58 W
18 W 36 W 58 W with 2 0.18 A 0.33 A 0.49 A
with 1 lamps 0.08 A 0.16 A 0.25 A lamps
with 2 lamps 0.17 A 0.32 A 0.50 A
ANSI C78.1 E2
17 W 32 W 40 W
with 1 lamps 0.15 A 0.28 A 0.36 A
with 2 lamps 0.30 A 0.56 A 0.72 A
Power factor cos p cos p ) 0.97 capacitive; no additional cos p ) 0.97 capacitive; no additional
compensation required compensation required E2
Disconnection of the light When opening the light In case of a lamp fault, the electronic ballast
Switch with safety lock; when opening the disconnects the defective lamp from the power
central lock, all poles of the voltage supply to supply.
the ballast are disconnected; contacts of the
switching element are NC contacts, they can
only be switched on again when the lamp cover
and the central locking system are closed.
E2
In case of a lamp fault, the electronic ballast
disconnects the defective lamp from the power
supply.
End of life switch The electronic ballast, type 6042/9..-. fulfills the
requirements according to IEC 61347-2-3
(simulation of the "end of life effect" of
E2
fluorescent lamps, "asymmetric pulse test 1"
and "asymmetric power test 2" correspond to
the test conditions in the draft IEC 60079-7 ed.4
appendix H).
E2
E2
2012-06-19·EK00·III·en Lighting E2/3
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
Technical Data
Luminous Characteristics
Lamps Fluorescent lamps with two-pin cap; Fluorescent lamps with two-pin cap;
T8;cap G13, according to IEC 60081 T8; cap G13, according to IEC 60081
Standard light: 1 x 18 W 2 x 18 W Standard light: 1 x 18 W 2 x 18 W
1 x 36 W 2 x 36 W 1 x 36 W 2 x 36 W
1 x 58 W 2 x 58 W 1 x 58 W 2 x 58 W
Side entry lamp: 1 x 18 W 2 x 18 W Side entry lamp: 1 x 18 W 2 x 18 W
1 x 36 W 2 x 36 W 1 x 36 W 2 x 36 W
Fluorescent lamps with two-pin cap; T8;
cap G13, according to ANSI C78.1
Standard light: 1 x 17 W 2 x 17 W
1 x 32 W 2 x 32 W
1 x 40 W 2 x 40 W
Side entry lamp: 1 x 17 W 2 x 17 W
1 x 32 W 2 x 32 W
Measures for light Standard: Deep bowl, reflector of the lamp is white
guidance Lateral dazzle limitation in the lamp cover
Special Additional reflector (can be easily mounted), deep broad bowl, polished aluminium
Operational efficiency broad beam
18 W / 36 W / 58 W with 1 lamps 83 %
with 2 lamps 76 %
Ambient conditions
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Operating temperature 18 (17) W: - 25 ... + 55 °C - 30 ... + 55 °C
range 36 (32) W: - 25 ... + 55 °C
58 (40) W: - 25 ... + 50 °C
Mechanical data
Degree of protection IP66 IP66
IP64 when using the breather 8162 IP64 when using the breathing gland 8162
(according to EN 60529) (according to EN 60529)
Protection class I(with internal PE connection)
Material
Enclosure Polyester resin, glass fibre-reinforcedColour white, similar to RAL 9010colour white, similar to
RAL 9010
Gasket Polyurethane foam gasket in the lamp cover
Lamp cover Polycarbonate
Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13,
hinged lamp cover
Assembly / Installation
Cable glands Standard light
Plastic 1 x M25 x 1.5 cable gland 8161 and
2 x M25 x 1.5 stopping plugs 8290 (enclosed)
Metal: 2 x metal plates M20 connected by means of PE for metal cable glands
Attention: cable glands must be ordered separately
Special: max. 4 holes M20, M25, NPT ½’’
max. 2 holes NPT ¾’’
Metal cable glands: M20, M25; earthing of the metal gland parts by means
of metal plates
Side entry lamp
In case of a pole mount adapter mounted in factory: 1 x M32 x 1.5 cable gland 8161
1 x M25 x 1.5 stopping plugs 8290 (enclosed in the delivery)
1 x M25 x 1.5 breathing gland (enclosed in the delivery)
Connection Standard: Terminal block with cover
Designation: L1 + N + PE (3-pin) or L1 + L2 + L3 + N + PE (5-pin)
Terminal capacity: max 2 x 6 mm2 (single-wire); 2 x 4 mm2 (finely stranded)
Special Cage clamp terminals
Terminal capacity: max 2 x 2,5 mm2 (single-wire); 2 x 2,5 mm2 (finely stranded)
(3 free terminals available)
E2
E2
E2
2012-06-19·EK00·III·en Lighting E2/5
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
Bracket for wall for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480
mounting with tube
05460E00
05500E00
05696E00
10809E00
Mounting kit for for the subsequent installation in standard lamps 0.000
through wiring DV 5 with 5 conductors,
2,5 mm2 for max. 16 A; L1, L2, L3, N, PE
for lights 18 W 115806 0.400
05503E00
for lights 36 W 115813 0.400
for lights 58 W 115819 0.440
DV3; screwed terminals 3 x 2.5 mm2, max. 16 A 0.000
L1 + N + PE
for lights 18 W 115802 0.200
for lights 36 W 115810 0.240
for lights 58 W 115816 0.260
Reflectors for later installation; broad deep bowl 0.000
for lights with one lamp 18 W 115694 1.103
05324E00 for lights with one lamp 36 W 115731 2.079
for lights with one lamp 58 W 115757 2.079
for lights with two lamps 18 W 115716 1.105
for lights with two lamps 36 W 115745 2.070
for lights with one lamp 58 W 115767 1.985
Socket key M8 / wrench size 13; 140486 0.126
to open/close the central locking
05321E00
05490E00
E2
Mounting bracket Mounting clamp mounted on a mounting rail for a variable 115777 0.400
mounting distance; 1 pair
05496E00
E2
Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120
05378E00
05555E00
Pipe clamp with mounting rail for a variable mounting distance; 0.000
Material: stainless steel
1 pair E2
R 11/2“ 115690 1.250
09402E00
R 2“ 115711 1.370
R 11/4“ 115728 1.250
Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020 E2
05703E00
E2
2012-06-19·EK00·III·en Lighting E2/7
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
04770E00 04771E00
EXLUX 6000 und EXLUX 6400 Standard Light EXLUX 6000 und EXLUX 6400 Side Entry Lamp
Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm) - Subject to Alterations
148
Mounting rail Wall mounting bracket 50° Wall mounting bracket 90°
E2
E2
for lights with one lamp for lights with two lamps
Reflectors
E2
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.
E2
E2
E2
E2
E2
E2
E2
2012-06-19·EK00·III·en Lighting E2/9
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
E2
> As pendant light fitting or
side entry lamp
> Version with 2 lamps:
18 W and 36 W E2
> Central locking
> Weekly functional test
> Light duration test of the
emergency lighting once a year E2
E2
E2
www.stahl.de
E2
Series EXLUX 6008 / 6408 E2
10068E00
E2
The lights of the Series EXLUX 6008 and EXLUX 6408 can be used
as emergency lighting
Class I
E2
ATEX / IECEx (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
EXLUX 6008 x x x EXLUX 6008 x x EXLUX 6008 x x x x x
For use in: For use in: For use in: E2
EXLUX 6408 x*) x*) x*) EXLUX 6408 x EXLUX 6408 x x x x x
For use in: For use in: For use in:
*) only ATEX
E2
E2
E2
E2
WebCode 6008A
E2
2013-06-11·EK00·III·en Lighting E2/1
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
Selection Table
Version Lamps Battery Lighting hours Order number Weight
kg
6008 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6008/522-9011-7147 8.200
Standard light
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6008/542-9011-7147 10.400
6008 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6008/922-9071-7147 10.800
Side entry lamp
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6008/842-9081-7147 13.000
6408 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6408/522-9011-7147 8.000
Standard light
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6408/542-9011-7147 10.200
(Zone 2, 21, 22)
6408 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6408/922-9071-7147 10.600
Side entry lamp
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6408/842-9081-7147 12.800
(Zone 2, 21, 22)
Order Number Supplement
Through wiring without 6.08/...-.0..-....
with 6 conductors (18 W only with spring-cage terminal) 6.08/...-.6..-....
Cable glands Standard 1 cable gland M25 x 1.5 and 6.08/...-..1.-....
2 stopping plugs M25 x 1.5
Explosion Protection
Global (IECEx)
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Gas and dust IECEx PTB 07.0053 --
Ex d e mb IIC T4 --
Ex tD A21 IP66 T80°C --
Europe (ATEX)
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Gas PTB 97 ATEX 2032 SNCH 03 ATEX 3519 (Zone 2)
E II 2 G Ex d e mb IIC T4 E II 3 G EEx nA II T4 (Zone 2)
Dust PTB 97 ATEX 2032 SNCH 03 ATEX 3518 (Zone 21)
SNCH 03 ATEX 3519 (Zone 22)
E II 2 D Ex tD A21 IP6. T80°C E II 2 D IP66 T80°C, T90°C (Zones 21, 22)
T80 °C at Ta = + 40 °C
T90 °C at Ta = + 50 °C
Certificates and approvals
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Certificates IECEx, ATEX, Brazil (UL do Brasil), ATEX, Belarus (GOST-B)
India (PESO), Canada (CSA),
Kazakhstan (GOST-K), Russia (GOST-R),
Ukraine (GOST-U), USA (FM),
Belarus (GOST-B), Serbia (IZP), Corea KGS),
China (CQST)
Other approvals ship approval (GL) --
Further parameters
Marking (CE) C 0158 C 0158
E2
E2
E2
E2
2013-06-11·EK00·III·en Lighting E2/3
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
Technical Data
Assembly Looping of the Standard light
cables On the connection side, there are two possibilities M25 x 1.5 for the
looping of the connecting line
(entry and exit on one side), also possible with lights subsequently
fitted with pole mount adapter.
Through wiring Standard light Lights are available with internal through wiring.
Entry and exit holes for connecting cables are positioned on the
opposite sides. Terminals: see Technical data.
Wiring cross-section 2.5 mm2 for max. 16 A
Assembly Standard light
Standard: 2 x M8 insert nuts in the enclosure
Special: Mounting grooves in the enclosure for the use of fastening
and ceiling rails for variable light installation
(variable mounting distances for lights 18 W: 312 ... 465 mm;
36 W: 670 ... 865 mm)
The pole mount adapter is mounted in factory and can be retrofitted
on the standard light
Side entry lamp
The light is mounted on a tube adapter with the diameter 42 mm
and fixed by means of a clamp.
The pole mount adapter is mounted in factory; it is also possible to
install it later on the standard light.
Insertion of the connecting cable:
If a factory-mounted pole mount adapter is used:
The cable is lead through the pole mount adapter into the light.
The cable is sealed by means of a gland M32 x 1.5.
(only possible for 36 W lights)
If a retrofitted pole mount adapter is used:
use the gland of the standard light
Flashing
1 s OFF
0.25 s ON E2
1.75 s OFF
Operating modes On delivery, the light is wired for a continuous operation;
if the jumper between the terminals 9 and 10 of the emergency light electronics is removed and an
external switch F is connected, the continuous mode with switchable emergency light is activated.
Terminals emergency E2
Terminals emergency lighting electronics
lighting electronics
Jumper
External Maintained operation with E2
Maintained operation switch F switchable emergency lighting
08711E01 08712E01
Function description
Continuous operation
In case of a power failure of the general lighting system, the battery will supply the light with power
independently of the light switch position. E2
Continuous operation with switchable emergency light blocking
in case of a power failure for the general lighting system, the light is only switched to the emergency
light mode if the external switch F is closed. The external switch switches the emergency light
automatically to "Ready" or "Not ready" depending, for example, on the operating times of the
system; the external switch is equipped with a potential-free contact.
E2
A maximum number of 30 lights can be connected to each external switch with series connection
or 50 lights in a star-like arrangement. The cable length must not exceed 500 m.
Cross section of the cable: at least 1.5 mm
Battery set
Version
Operating voltage
Gas-tight NiCd battery
6V
E2
Capacity 7 Ah
Replacing the battery set When the battery enclosure is opened, the battery set is de-energised;
the battery set can be removed from the enclosure after disconnection of the plug-in contacts
E2
E2
E2
E2
E2
2013-06-11·EK00·III·en Lighting E2/5
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
04936E00
36 W 3350 Im 108951 0.200
Bracket for wall for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480
mounting with tube
05460E00
Pole mount adapter for the subsequent mounting on lights 18 W and 36 W, 115698 2.100
completely with assembly parts
05500E00
10809E00
13556E00
05321E00
05567E00
05555E00
Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120
E2
05378E00
E2
05490E00
Mounting bracket Mounting clamp mounted on a mounting rail for a variable 115777 0.400
mounting distance; 1 pair
05496E00
E2
Top rail for ceiling suspension of the lamp 115733 0.280
1 pair
05493E00 E2
Pipe clamp R 11/2“ 115690 1.250
R 2“ 115711 1.370
R 11/4“ 115728 1.250
09402E00 with mounting rail for a variable mounting distance;
Material: stainless steel
E2
1 pair
Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020
05703E00 E2
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations
E2
04772E00 04773E00
E2
Dimensions Light Dimensions Light
in mm 18 W 36 W in mm 18 W 36 W
L1 782 1392 L 806 1416
L2 1) 400 800 E2
L3 2) 312 ... 465 670 ... 865
1) fixed mounting distance
2) variable mounting distance
EXLUX 6008 und EXLUX 6408 Standard Light EXLUX 6008 und EXLUX 6408 Side Entry Lamp E2
We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without
notice.The illustrations cannot be considered binding.
E2
E2
2013-06-11·EK00·III·en Lighting E2/7