WIKA

PRESSURE GAUGE
ITEM: PI‐2882‐1,PI‐2882‐2,PI‐2882‐3,PI‐2880‐2A,PI‐2880‐3,PI‐2880‐4,PI‐
2880‐5,PI‐2880‐6,PI‐2880‐7,PI‐2880‐8,PI‐2880‐9, PI‐2881‐1,PI‐2881‐2,PI‐
2881‐3,PI‐2880‐1A,PI‐2880‐10,PI‐2880‐11,PI‐2880‐12, PI‐2880‐13, PI‐
29XX‐6,PI‐29XX‐7,PI‐29XX‐8, PI‐29XX‐9
SWAGELOK
RELIEF VALVE
ITEM: PSV‐2883, PSV‐2885
www.swagelok.com

P ro p o r t i o n a l R e l i e f Va l v e s

R Series
■ Liquid or gas service

■ Set pressures from 10 to 6000 psig (0.68 to 413 bar)

■ 1/4 and 1/2 in. and 6 to 12 mm end connections


2 Proportional Relief Valves

Cap
provides easy external
Spring
set pressure adjustment
adjusts to provide
desired set pressure Label
identifies set
pressure range

Lock nut
maintains cap position, Lock wire capability
ensuring set pressure adjustment secures cap to maintain
set pressure adjustment

Quad seal
eliminates leakage
around stem during
relief mode

O-ring
provides elastomer-to-metal End connections
seal for positive shutoff at seat. include gaugeable Swagelok tube
(Other series use bonded disc. fittings and NPT or ISO pipe threads
See Materials of Construction)

R3A series valve shown.

Features Applications
High-Pressure Valves R series relief valves are proportional relief valves that open
gradually as the pressure increases. Consequently, they do
■ Service up to 6000 psig (413 bar)
not have a capacity rating at a given pressure rise
■ Multiple springs for a selection of set pressure ranges (accumulation), and they are not certified to ASME or any
■ 1/4 in. and 6 and 8 mm end connections—R3A series other codes.
■ 1/2 in. and 12 mm end connections—R4 series  The system designer and user must determine
applicable code requirements and whether R series
Low-Pressure Valves relief valves are acceptable for use.
■ Service up to 300 psig (20.6 bar)
■ One spring for the full set pressure range Operation
■ 1/4 in. and 6 and 8 mm end connections—RL3 series R series relief valves OPEN when system pressure reaches
■ 1/2 in. and 12 mm end connections—RL4 series the set pressure and CLOSE when system pressure falls
below the set pressure.
■ High-pressure R3A and R4 series—select and install the
spring that covers the required set pressure; apply the
matching label to the cap.
■ Low-pressure RL3 and RL4 series—the spring is already
installed.
 For valves not actuated for a period of time, initial
relief pressure may be higher than the set pressure.
Proportional Relief Valves 3

Technical Data
Pressure-Temperature Ratings
Series R3A R4 RL3 and RL4
Working Pressure at 6000 psig (413 bar);
6000 psig (413 bar) 300 psig (20.6 bar)
70°F (20°C) up to 8000 psig (551 bar) during relief
Set Pressure➀ 50 to 6000 psig (3.4 to 413 bar) 50 to 1500 psig (3.4 to 103 bar) 10 to 225 psig (0.68 to 15.5 bar)
Outlet Pressure➁ 1500 psig (103 bar) 2500 psig (172 bar) 225 psig (15.5 bar)
Fluoro- Ethylene Fluoro- Ethylene Fluoro- Ethylene
carbon Neo- pro- carbon Neo- pro- carbon Neo- pro-
Seal Material FKM Buna N prene pylene FKM Buna N prene pylene FKM Buna N prene pylene
Temperature, °F (°C) Maximum Set Pressure, psig (bar)
–40 (–40) —
— —
–30 (–34) —

–10 (–23) — —

0 (–17) — — —
10 (–12) 6000
6000 (413)
25 (–4)
6000 (413)
30 (–1) 6000
(413)
50 (10) (413) 225
225 (15.5)
5580 5580 5580 5580 225 (15.5)
150 (65) 225 (15.5)
(384) (384) (384) (384) (15.5)
1500 1500 1500
5160 5160 5160 5160 (103) (103) (103)
200 (93) 1500
(355) (355) (355) (355)
(103)
4910 4910 4910 4910
250 (121)
(338) (338) (338) (338)
275 (135) 4660
— — — — —
300 (148) (321) —
➀ The pressure-temperature ratings are based upon laboratory testing to ensure that the cracking pressure does not deviate by more than 20 % from the initial room
temperature set pressure.
➁ Outlet pressure should not exceed inlet pressure.

Set Pressure and Resealing Pressure Back Pressure


■ Set pressure is the upstream pressure at which the first High-Pressure Valves (R3A and R4 Series)
indication of flow occurs. Set pressure of each valve after
The effect of system back pressure is minimized by the design
initial relief is repeatable within ± 5 % at room temperature.
of these high-pressure valves.
■ Resealing pressure is the upstream pressure at which there
is no indication of flow. Resealing pressure is always lower Low-Pressure Valves (RL3 and RL4 Series)
than set pressure. System back pressure increases the set pressure of the valve.
To compensate, multiply the back pressure by 0.8 and subtract
Testing the result from the desired set pressure. Use the result to pre-set
Every R series proportional relief valve is tested for set and the valve while back pressure is equal to atmospheric pressure.
resealing performance. Example:
Desired set pressure is 120 psig. System back pressure is
Minimum Resealing 40 psig.
Test Set Pressure Pressure as a Percentage
Series psig (bar) of Set Pressure, % Step 1. Multiply back pressure by 0.8.
10 to 20 (0.68 to 1.3) 50 40 psig  0.8 = 32 psig.
RL3, RL4
175 to 225 (12.0 to 15.5) 91 Step 2. Subtract result from desired set pressure.
100 to 200 (6.8 to 13.7) 50 120 psig – 32 psig = 88 psig.
R3A, R4
850 to 1000 (58.5 to 68.9) 84 Step 3. Pre-set proportional relief valve to 88 psig.

Cleaning and Packaging Oxygen Service


All Swagelok R series relief valves are cleaned and packaged For more information about hazards and risks of oxygen-
in accordance with Swagelok Specification SC-10. enriched systems, see the Swagelok Oxygen System Safety
technical report.
4 Proportional Relief Valves

Materials of Construction
Component Material Grade/ASTM Specification
RL3 and R3A RL4 and R4 RL3, R3A—nickel-plated brass;
1 Plug
RL4, R4—brass
1 1
2 2 Cap 316 SS/A479
2 3 Label Polyester
3 RL3, R3A—316 SS powdered metal;
4 Lock nut
3 RL4, R4—316 SS/A276
4 5 Spring S17700 SS/AMS 5678
6 Sleeve 304 SS/A240
RL3 5
only 4 7 Spring support
RL3, R3A—316 SS powdered metal;
RL4, R4—316 SS/A276
6 8 Bonnet 316 SS/A479
7 5
9 O-ring Fluorocarbon FKM

RL4 10 Quad seal PTFE-coated fluorocarbon FKM


8 only RL3, R3A—316 SS/A666;
11 Retainer
RL4, R4—316 SS/A479
6 12 Stem 316 SS/A479
12a Bonded stem Fluorocarbon FKM-bonded ➀
9 7
13 Bonded disc 316 SS/A479
10 R3A
11 only 14 Seat 316 SS/A479
15 Gasket PTFE-coated 316 SS/A240
12 12 8 16 Seat retainer 316 SS/A479
17 O-ring Fluorocarbon FKM
13 18 Insert 316 SS/A479
16
14 19 Body 316 SS/A182
17
Molybdenum disulfide-based dry film
15 18 9 Lubricants
and paste; silicone-based
10 Wetted components listed in italics.
19 R4
11 ➀ Material Safety Data Sheet for bonding agents available on request.
only
12
12a

13
19

RL3 R3A RL4 R4


Proportional Relief Valves 5

Flow Data at 70°F (20°C)


Air Water
RL3 and RL4 Series RL3 RL3 and RL4 Series RL3
Air Flow, std L/min RL4 Water Flow, L/min RL4
0 100 200 300 400 500 0 1 2 3 4 5 6 7
300 300
Set Pressure 20 20
225 psig (15.5 bar) Set Pressure
250 250 225 psig (15.5 bar)
Inlet Pressure, psig

Pressure drop, bar


Inlet Pressure, bar

Pressure drop, psi


16 16

200 200
150 psig (10.3 bar) 150 psig (10.3 bar) 12
12
150 150
100 psig (6.8 bar) 100 psig (6.8 bar)
8 8
100 100
50 psig (3.4 bar) 50 psig (3.4 bar)
4 4
50 50

0 0 0 0
0 2 4 6 8 10 12 14 16 18 20 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Air Flow, std ft3/min Water Flow, U.S. gal/min

R3A and R4 Series R3A R3A and R4 Series R3A


Air Flow, std L/min Water Flow, L/min
0 100 200 300 400 500 0 0.2 0.4 0.6 0.8 1.0
6000
Set Pressure 6000
5500 psig (378 bar) 400 Set Pressure
Inlet Pressure, psig

5500 psig (378 bar)


5600 Inlet Pressure, bar 400

Pressure drop, bar


Pressure drop, psi
5500
5200 360

5000 350
4500 psig (301 bar)
4800
4500 psig (301 bar)
320
4500
4400 300

4000
4000 280
3500 psig (240 bar)
0 2 4 6 8 10 12 14 16 18 20 250
Air Flow, std ft3/min 3500
0 0.04 0.08 0.12 0.16 0.20 0.24 0.28

Water Flow, U.S. gal/min


R3A R3A
Air Flow, std L/min R4 Water Flow, L/min R4
0 500 1000 1500 2000 2500 0 0.2 0.4 0.6 0.8 1.0
4000
4000 Set Pressure
3500 psig (241 bar)
250
Inlet Pressure, psig

250
Inlet Pressure, bar

3500
3500

Pressure drop, bar


Pressure drop, psi

Set Pressure
3000 2600 psig (179 bar) 200 3000 2600 psig (179 bar)
200

2500 2500
2000 psig (137 bar) 150
2000 psig (137 bar) 150
2000
2000
1500 100
1000 psig (68.9 bar) 1500 100
1000 1000 psig (68.9 bar)
0 10 20 30 40 50 60 70 80 90 100
1000
Air Flow, std ft3/min 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28
Water Flow, U.S. gal/min
R3A R3A
Air Flow, std L/min R4 Water Flow, L/min R4
0 500 1000 1500 2000 2500 0 1 2 3 4 5 6 7
800 800

50 50
700 700
Inlet Pressure, psig

Pressure drop, bar


Pressure drop, psi
Inlet Pressure, bar

Set Pressure
550 psig (37.8 bar) Set Pressure
600 600 550 psig (37.8 bar)
40 40

500 500
350 psig (24.1 bar)
30 30
400 400 350 psig (24.1 bar)

300 200 psig (13.7 bar) 20 300 20


200 psig (13.7 bar)
200 200
0 10 20 30 40 50 60 70 80 90 100 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Air Flow, std ft3/min Water Flow, U.S. gal/min
6 Proportional Relief Valves

Dimensions
Dimensions, in inches (millimeters), are Low-Pressure Valves (RL3 and RL4 Series)
for reference only and are subject to
change. End Connections Dimensions, in. (mm)
Ordering
Inlet/Outlet Size Number A B C D E H
RL3 series: 0.19 in. (4.8 mm) fully open orifice
1/4 in. SS-RL3S4
Swagelok 1.44 4.14
6 mm SS-RL3S6MM
0.06 in. tube fittings (36.6) (105)
(1.5 mm) 8 mm SS-RL3S8MM 1.60
lock wire (40.6)
hole Male NPT/
Swagelok 1/4 in. SS-RL3M4-S4 2.70 0.43 4.09
A (68.6) (10.9) (104)
max tube fitting
0.09 in. Male NPT/ 1.19 3.89
(2.2 mm) 1/4 in. SS-RL3M4-F4 (30.2) (98.8)
lock wire
E female NPT 1.17
max
hole Male ISO/ (29.7)
1/4 in. SS-RL3M4F4-RT
female ISO➀
RL4 series: 0.25 in. (6.4 mm) fully open orifice
1.72 5.81
1/2 in. SS-RL4S8
Swagelok (43.7) (148)
tube fittings 1.83 5.92
Outlet B 12 mm SS-RL4S12MM
(46.5) (150)
4.09 0.50 5.37
Inlet Male NPT/ (104) (12.7) (136)
1.72
Swagelok 1/2 in. SS-RL4M8S8
1.43 (43.7) 5.52
tube fitting
(36.3) (140)
D C Male NPT/ 1.43
1/2 in. SS-RL4M8F8
female NPT (36.3)

High-Pressure Valves (R3A and R4 Series)


End Connections Dimensions, in. (mm)
Ordering
Inlet/Outlet Size Number A B C D E H
R3A series: 0.14 in. (3.6 mm) fully open orifice
1/4 in. SS-4R3A
Swagelok 1.44 4.14
6 mm SS-6R3A-MM
tube fittings (36.6) (105)
8 mm SS-8R3A-MM 1.60
0.06 in. (40.6)
(1.5 mm) H Male NPT/
lock wire max Swagelok 1/4 in. SS-4R3A1 2.70 0.43 4.09
hole (68.6) (10.9) (104)
tube fitting
Male NPT/ 1.19 3.89
1/4 in. SS-4R3A5 (30.2) (98.8)
female NPT 1.17
0.09 in.
(2.2 mm) Male ISO/ (29.7)
1/4 in. SS-4R3A5-RT
lock wire female ISO➀
hole
R4 series: 0.25 in. (6.4 mm) fully open orifice
1.72 5.81
1/2 in. SS-R4S8
Swagelok (43.7) (148)
tube fittings 1.83 5.92
12 mm SS-R4S12MM
(46.5) (150)
Outlet
4.09 0.50 5.37
Male NPT/ (104) (12.7) (136)
1.72
Swagelok 1/2 in. SS-R4M8S8
Inlet 1.43 (43.7) 5.52
tube fitting
(36.3) (140)
Male NPT/ 1.43
1/2 in. SS-R4M8F8
Valve with Manual female NPT (36.3)
Override Handle Dimensions shown with Swagelok tube fitting nuts finger-tight.
➀ See specifications ISO 7/1, BS21, DIN-2999, and JIS B0203.
Proportional Relief Valves 7

Ordering Information Options and Accessories


Low-Pressure Valves (RL3 and RL4 Series) Seal Materials Seal Material Designator
Valve contains spring; set pressure must be adjusted. Select Fluorocarbon FKM is the Buna N -BU
a valve ordering number. standard seal material.
Ethylene
Optional seal materials are -EP
Spring Kits propylene
available. To order, add a seal
Spring kits include spring and installation instructions. Select Neoprene -NE
material designator to the
a spring kit ordering number. valve ordering number. -VI for seal kits;
Fluorocarbon
no designator
Example: SS-RL3S4-BU FKM
for valves
Spring Kit Set Pressure Range
Series Ordering Number psig (bar) Seal Kits
RL3 177-13K-RL3 Fluorocarbon FKM, Buna N, ethylene propylene, and
10 to 225 (0.68 to 15.5)
RL4 177-13K-RL4 neoprene seal kits are available. To order, insert a seal
material designator as a prefix (R3A series) or suffix (all
others) to the seal kit basic ordering number.
High-Pressure Valves (R3A and R4 Series)
Examples: BU-R3A-K2
Valve does not contain spring. Select a valve ordering number
SS-3K-RL3-BU
and a spring kit ordering number.
Spring Kits RL3 Series R3A Series RL4 Series R4 Series
Spring kits include spring, label, 302 SS lock wire with seal, Seal kit basic ordering number
spring support, and installation instructions. SS-3K-RL3- -R3A-K2 SS-3K-RL4- SS-3K-R4-
Select a spring kit basic ordering number and add the spring Seal kit contents
designator for the desired set pressure range. O-ring, O-ring,
O-rings (2), O-ring,
Examples: 177-R3A-K1-F quad seal, quad seal,
quad seal, quad seal,
bonded disc, bonded disc,
177-13K-R4-C retainer, bonded stem,
retainer, retainer,
instructions instructions
instructions instructions
Set Pressure Range Spring Spring
psig (bar) Designator Color
R3A series spring kit: basic ordering number 177-R3A-K1- Manual Override
50 to 350 (3.5 to 25) A Blue Handles
350 to 750 (25 to 50) B Yellow
Phenolic
A manual override handle handle
750 to 1500 (50 to 100) C Purple opens the valve without
316 SS
1500 to 2250 (100 to 155) D Orange changing the set pressure.
pull rod
2250 to 3000 (155 to 205) E Brown For use with:
3000 to 4000 (205 to 275) F White ■ RL3 and RL4 series—
4000 to 5000 (275 to 340) G Red standard spring
5000 to 6000 (340 to 410) H Green ■ R3A series—A, B, and C
springs only 316 SS spring
R4 series spring kit: basic ordering number 177-13K-R4-
■ R4 series—A spring only.
support
50 to 350 (3.5 to 25) A Blue
350 to 750 (25 to 50) B Yellow Handle diameter is 1.50 in.
(38.1 mm). Maximum overall
750 to 1500 (50 to 100) C Purple
height of valve with handle
in closed position:
Special Cleaning and Packaging (SC-11) ■ 5.16 in. (131 mm) for R3A
To order R series relief valves processed in accordance with and RL3 series
Swagelok Special Cleaning and Packaging (SC-11) to ensure ■ 6.78 in. (172 mm) for R4
compliance with product cleanliness requirements stated in and RL4 series.
ASTM G93 Level C, add -SC11 to the valve ordering number. To order, add -MO to the valve ordering number.
Example: SS-RL3S4-SC11 Example: SS-RL3S4-MO
Manual Override Manual Override Kit
Handle Kits Series Ordering Number
Kits contain handle, pull rod, RL3, R3A SS-R3A-K5
spring support, and RL4, R4 SS-R4-K5
instructions. To order, select
the desired kit ordering number.
 Some system applications require relief valves to
meet specific safety codes. The system designer and
user must determine when such codes apply and
whether these relief valves conform to them.

Safe Product Selection


When selecting a product, the total system design must
be considered to ensure safe, trouble-free performance.
Function, material compatibility, adequate ratings,
proper installation, operation, and maintenance are the
responsibilities of the system designer and user.
Swagelok—TM Swagelok Company
© 2001, 2002, 2003, 2004 Swagelok Company
Caution: Do not mix or interchange parts with those of Printed in U.S.A., MI
other manufacturers. February 2004, R6
MS-01-141
Mechanical
Pressure Measurement
Bourdon Tube Pressure Gauges
Stainless Steel Series
Type 232.50 - Dry Case
Type 233.50 - Liquid-filled Case
WIKA Datasheet 23X.50

Applications

 With liquid filled case for applications with high dynamic


pressure pulsations or vibration
 Suitable for corrosive environments and gaseous or
liquid media that will not obstruct the pressure system
 Process industry: chemical/petrochemical, power
stations, mining, on and offshore, environmental tech-
nology, mechanical engineering and plant construction

Special features

 Excellent load-cycle stability and shock resistance


 All stainless steel construction
 Positive pressure ranges to 20,000 psi

Standard Features
Bourdon Tube Pressure Gauge Model 232.50
Design
ASME B40.100 & EN 837-1
Temperature error
Sizes Additional error when temperature changes from reference
2½”, 4”, 4½” & 6” (63, 100, 115 and 160 mm) temperature of 68°F (20°C) ±0.4% for every 18°F (10°C) rising
or falling. Percentage of span.
Accuracy class
2½”: ± 2/1/2% of span (ASME B40.100 Grade A) Weather protection
4”, 4½” & 6”: ± 1.0% of span (ASME B40.100 Grade 1A) Weather tight (NEMA 4X / IP65)

Ranges Pressure connection


Vacuum / Compound to 200 psi Material: 316L stainless steel
Pressure from 0/15 to 0/15,000 psi - 2½”, 4”, 4½” Lower mount (LM) or lower back mount (LBM)
Pressure from 0/10 to 0/20,000 psi - 6” Center back mount (CBM) for 2½” size
or other equivalent units of pressure or vacuum 1/4” NPT or 1/2” NPT (other connections available)
Working pressure Bourdon tube
2½”: Steady: 3/4 scale value Material: 316L stainless steel
Fluctuating: 2/3 full scale value 1,000 psi: C-type
Short time: full scale value 1,500 psi: helical type
4”, 4½” & 6”: Steady: full scale value Movement
Fluctuating: 0.9 x full scale value Stainless steel
Short time: 1.3 x full scale value
Dial
Operating temperature White aluminum with black lettering, 2½” with stop pin
Ambient: -40°F to +140°F (-40°C to +60°C) - dry
-4°F to +140°F (-20°C to +60°C) - glycerine filled Pointer
-40°F to +140°F (-40°C to +60°C) - silicone filled Black aluminum, adjustable
Medium: +392°F (+200°C) maximum - dry
+212°F (+100°C) maximum - liquid filled

WIKA Datasheet 23X.50 ·01/2009 Page 1 of 2


Case Optional extras
Stainless steel  Other pressure connections
2½”- with pressure relief/fill plug on top of case
4”, 4½” and 6”- with blow out plug on back of case and  Monel wetted parts (Type 26X.50)
fill plug on top of case  Front flange, SS (CBM and LBM only)
For pressure ranges < 160 psi, case has compensating  Rear flange, SS
valve/fill plug to vent case pressure  U-clamp mounting, SS (not available on 4½”)
 Silicone or Halocarbon case filling
Bezel ring
Stainless steel, bayonet-type  Non-adjustable pointer
 Red drag pointer or mark pointer
Window  Safety glass window
Polycarbonate (2½”) and Safety Glass (4”, 4½” & 6”)  Custom dial layout
with Buna-N gasket  Other pressure scales available
bar, kPa, MPa, kg/cm² and dual scales
Case fill
 Integral alarm contacts or transmitters
Glycerine 99.7% - Type 233.50

Dimensions

Size
A B C D4 E G H J L M N S T W Weight³
2½” mm 63 54 33 62 9.5 57 Note1 3.6 3 85 75 5 14 0.35 lb. dry
in 2.48 2.13 1.30 2.44 0.37 2.24 0.14 0.12 3.35 2.95 0.20 1/4” 0.55 0.44 lb. filled
4” mm 101 87 49.5 99 15.5 83 30 4.8 3 132 116 5 22 1.32 lb. dry
in 3.98 3.43 1.95 3.90 0.61 3.27 1.18 0.19 0.12 5.20 4.57 0.20 1/2” 0.87 1.98 lb. filled
4½” mm 121 97 49.5 119 15.5 83 30 5 3 148 137 5 22 1.76 lb. dry
in 4.76 3.82 1.95 4.68 0.61 3.27 1.18 0.2 0.12 5.83 5.39 0.20 1/2” 0.87 3.08 lb. filled
6” mm 161 118 49.5² 163.71 15.5 83 50 5.8 3 196 178 5 22 2.42 lb. dry
in 6.34 4.65 1.95² 6.45 0.61 3.27 1.97 0.23 0.12 7.72 7.01 0.20 1/2” 0.87 4.40 lb. filled
¹ Center back mount (CBM)
² Plus 0.63“ ( 16 mm) for pressure ranges > 1,500 psi
³ Weight without optional accessories
4
D (+) 1mm for panel cutout

Page 2 of 2 WIKA Datasheet 23X.50 · 01/2009

Ordering information
Pressure gauge model / Nominal size / Scale range / Size of connection / Optional extras required
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
Modifications may take place and materials specified may be replaced by others without prior notice. WIKA Instrument Corporation
1000 Wiegand Boulevard
Lawrenceville, GA 30045
Tel (770) 513-8200 Toll-free 1-888-WIKA-USA
Fax (770) 338-5118
E-Mail info@wika.com
www.wika.com
PARKER VERIFLO
HYDRAULIC REGULATOR
ITEM: HPR‐1,HPR‐2
SS High Pressure
IR4000 Series Regulator Internally
Threadless Design

Parker Hannifin Corporation’s Veriflo Division


materials of construction
presents the IR4000 Series internally threadless Wetted
pressure regulator for instrument/analyzer Body . . . . . . . . . . . . . . . . . . . . 316L Stainless Steel,
and semiconductor applications. The internal . . . . . . . . . . . . . . . . . . . . . Hastelloy C-22®, Monel®
Compression Member. . . . . . . . . . . . . . . Inconel®
threadless design minimizes purge times, and
Diaphragm . . . . . . . . . . . . . . . . . . Hastelloy C-22®
reduces carrier and calibration gas usage. The Poppet . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elgiloy®
IR4000's seat materials meet the requirements Poppet Spring . . . . . . . . . . . . . . . . . . . . . Inconel®
Carrier. . . . . . . . . Stainless Steel*, Hastelloy C-22®
for corrosive and/or higher temperature media
Back-up Washer. . . . . . . . . . . . . . Hastelloy C-22®
requirements. Seat. . . . . . . . . . . . . . . . PCTFE, PEEK™ or Vespel®
Back-up O-ring . . . . . . . . Viton®, optional Teflon®
Instrument applications include gas manage- Inlet Screen/Filter. . . . . . . . . . 316L Stainless Steel,
ment systems in petrochemical/refineries and . . . . Hastelloy C-22® (Hastelloy®, Monel® bodies)
process analyzer systems. Semiconductor
Non-Wetted
applications include general purpose gas Cap . . . . . . . . . . . . . . . . . . . . Nickel Plated Brass,
management (Air, Clean Dry Air (CDA), and . . . . . . . . . . . . . . . . . . . . . optional Stainless Steel
Nut . . . . . 316 Stainless Steel, Nickel Plated Brass††
Plant Nitrogen).
Knob (black) . . . . . . . . . . . . . . . . . . . . ABS Plastic
The IR4000 is a high pressure regulator that can


operating conditions
be ordered with a variety of options to meet Maximum inlet . . . . . . . . . . . 4000 psig (276 barg)
a wide range of system design requirements. Outlet. . . 1-10 psig† (.7 barg), 2-30 psig (2 barg),
. . . . . . . . 3-60 psig (4 barg), 4-100 psig (7 barg),
. . . . . 5-250 psig (17 barg), 10-500 psig (35 barg)

Temperature:
PCTFE . . . . . . . . . . . -40°F to 150°F (-40°C to 65°C)
PEEK™ . . . . . . . . . -40°F to 275°F (-40°C to 135°C)
Vespel® . . . . . . . . -40°F to 500°F (-40°C to 260°C)

functional performance
Flow capacity:
Standard. . . . . . . . . . . . . . . . . . . . . . . . . . Cv = .06
Optional . . . . . . . . . . . . . . . . . . . . . . C = .02, .15†
v
............
(SEMI Flow Coefficient Test #F-32-0998 )

Design Proof Pressure . . . . 6000 psig (414 barg)


Design Burst Pressure . . . . 12000 psig (828 barg)

Maximum Inboard Design


Leak Rate . . . . . . . . . . . . . . . < 2 x 10-8 scc/sec HE

Supply Pressure Effect:


.02 Cv . . . . . . . . . . . . . . . . . .23 psig per100 psig
............ (.016 barg per 7 barg)
.06 Cv . . . . . . . . . . . . . . . . . . .6 psig per100 psig
............. (.04 barg per 7 barg)
.15 Cv . . . . . . . . . . . . . . . . . 1.5 psig per100 psig
.............. (.1 barg per 7 barg)

internal volume
4.0 cc without fittings

approximate weight
1.5 lbs (.7 kg)

* Proprietary Carpenter Stainless Steel with corrosion resistance


equal or better than 316 Stainless Steel.
† Refer to Range Table for specific information.
†† Nickel Plated Brass for PCTFE seat.

P R E S S U R E R E G U L AT O R S • 2
IR4000 Series

Product Features and Benefits

Unique patented compression member Positive upward and downward stops


loads the seal to the body without requiring increases cycle life by preventing over
a threaded nozzle or additional seals to stroking of the diaphragm.
atmosphere.
Low internal volume reduces cycle and


Selection of seat materials for media purge time.

compatibility and temperature


Captured bonnet allows for safety venting.

▼ ▼
applications.
Standard units can be dome loaded
Meets NACE Standard MR0175.
▼ ▼ ▼ ▼

(with clean dry air or nitrogen).


O2 Cleaned.
The use of Inconel®, Hastelloy C-22®, and


Fully swept design. Elgiloy® provide superior corrosion resistance
and high repeatability.
Internally threadless seat design
promotes long seat life. ▼ Close tolerances and tight alignment of
moving components minimize hysteresis.
Convoluted, Hastelloy C-22® diaphragm

provides high corrosion resistance and Unique carrier design disperses gas

increases cycle life. uniformly through the regulator to


improve purging.

Dimensional Drawing

Ø1.44 (36.6 MM)


HOLE REQD IN
PANEL FOR
MOUNTING.
10-32 UNF-2B

4.91
(124.7) Ø2.32
(58.9 mm)
1.38 FLATS
2.68 (34.9 mm)
(68.0 mm)

.75
(19.1 mm) .75
(19.1 mm)
Ø2.00
(50.8 mm)

3 • P R E S S U R E R E G U L AT O R S
IR4000 Series

Flow Curves Porting Configurations


IR4000 .06 CV
14
LP
Outlet Pressure (psig)

12

400 Inlet psig


10 LP VERIFLO
HP LP VERIFLO
CORPORATION
HP
CORPORATION

200 Inlet psig LP


6
Porting Code 2P
Por Porting Code 4PB
Por
100 Inlet psig
4 LP
LP HP

20 Inlet psig 50 Inlet psig


2

LP HP LP HP
0 VERIFLO
CORPORATION VERIFLO
CORPORATION

0 10 20 30 40
N2 Flow (slpm)

LP
IR4002 .06 CV
70 Porting Code 3P
Por Porting Code 5P
Por
2000 Inlet psig LP HP LP HP
Outlet Pressure (psig)

60
1000 Inlet psig

50
LP VERIFLO
HP LP VERIFLO
HP
250 Inlet psig CORPORATION CORPORATION

40

30 150 Inlet psig LP HP

Porting Code 4P
Por Porting Code 6P
Por
20

10
Gauge Index
0
0 50 100 150 200 250 300 350 400

N2 Flow (slpm)
2P No Gauge Ports
IR4003 0.15 CV
3P One gauge Port
120

110 4P Two gauge Ports


Outlet Pressure (psig)

100
90
1000 Inlet psig
4PB One Gauge Port
80
5P Two Gauge Ports
70

60
150 Inlet psig 500 Inlet psig
6P Two Gauge Ports
50 250 Inlet psig
40

30

20
10

0
0 100 200 300 400 500 600 700

N2 Flow (slpm)

P R E S S U R E R E G U L AT O R S • 4
IR4000 Series

Ordering Information
IR400 S 4 B
BASIC SERIES 2P CGA#*
Range Outlet Gauge
3P Y/X 320
0 = 1 -10 psig 0 - 30 psig 4P Y/X Y/X 330
1 = 2 - 30 psig 0 - 60 psig 4PB Y/X 350
2 = 3 - 60 psig 0 - 100 psig 5P Y/X Y/X 510
3 = 4 - 100 psig 0 - 200 psig
580
4 = 5 - 250 psig 0 - 400 psig
590
5 = 10 - 500 psig 0 - 600 psig Additional Configurations
Available Upon Request
BODY MATERIAL
S = 316L Stainless Steel OPTIONAL FEATURES (See Notes)
(Hastelloy® & Monel® Available L = Teflon® Back-Up O-Ring
Upon Request) (PCTFE & PEEK™ seat only)
R = Relief Valve (4PB and 5P Only)
FLOW CAPACITY V = Outlet Valve NOVAS44MF(STD)(See Notes)
= .06 Cv (Standard)
1 = .02 Cv Please select ONE or NONE of the following:
2 = .15 Cv (See Range Table) D = Dome Loaded
SEAT MATERIALS G = Tamper Proof
K = PCTFE M = Metal Knob(Black)
P = PEEK™ For optional color knobs consult factory
V = Vespel®
Note: PANEL MOUNT OPTION:
PORTING Order Panel Nut Ring P/N 41900363
as separate line item.
OUTLET GAUGE
See Outlet Gauge under PORT MOUNTING
BASIC SERIES (see above) for standards. B = .75 (19.1) port height w/ .75 (19.1) mounting
(Additional ranges available upon request) hole pattern.
(Additional Port Mounting available on request)
INLET GAUGE
3000 psig std.
400 psig with the 10 psig range PORT STYLE
2000 psig with .15 Cv option 4 = 1/4" NPT Female Standard
Other = (Additional sizes available upon request)
NOTE:
Outlet Valve: Compression End Connection On Outlet
(A-Lok, CPI) Can Be Substituted for NPTF Connection Range Table
Upon Request.
Model Basic Max Inlet PSIG
ORDERING REGULATORS WITHOUT GAUGES Series Cv
Example #1 .02 .15
.06
IR4003SK2P4B (No X required for gauges,
inlet & outlet ports only) IR4000 400 400 400
Example #2 IR4001 4000 4000 1250
IR4003SK3PX4B (One X for gauge port)
Example #3 IR4002 4000 4000 1250
IR4003SK4PBX4B (One X for gauge port) IR4003 4000 4000 1250
Example #4
IR4004 4000 4000 1250
IR4003SK4PXX4B (Two X's for gauge ports)
IR4005 4000 4000 1250
* Do not exceed the rated pressure of the CGA connection
Hastelloy C-22® is a registered trademark of Haynes International, Inc.
PEEK™ is a trademark of Victrex plc.
Inconel® and Monel® are registered trademarks of Inco Alloys International.
Elgiloy® is a registered trademark of Elgiloy Company.
Viton® is a registered trademark of DuPont Dow Elastomers.
Teflon® is a registered trademark of DuPont Company.

5 • P R E S S U R E R E G U L AT O R S
SEETHRU
LEVEL GAUGE
ITEM: LG‐2880‐1,LG‐2880‐2
PARKER ‐ FCH OLEAR
BLADDER ACCUMULATOR
ITEM: ACC1, ACC2, ACC3
ASME
Bladder Accumulators
207 bar to 420 bar range
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar
4
Design Features and Benefits 2
2
C 1 D
1 Shell 3
3
Forged seamless chrome molybdenum steel, designed and
5
manufactured to ASME VIII Division 1‘U’ coded.
1
2 Label
With assembly specification and installation details.

3 Material Certification
Available on request for all major pressure loaded parts to EN A
10204 3.1

4 Finish
One coat primer paint as standard. Special paints available. 3

2
5 Bladder
Totally enclosed construction with an extensive range of B
1
elastomers available. See Bladder datasheet for further
6 1
details.
2
7
6 Fluid Port Assembly E
Integral high-flow port and poppet valve assembly with an 4
4
anti-extrusion ring. For options see page 3.
3
5
7 Safety
8 SECTION A-A
All gas-loaded accumulators are pressurised vessels and
SCALE 1 : 5
it is recommended that safety consideration be given to 9
the application in which they are used. A relief valve should
always be fitted to the hydraulic system with the option of a
UNLESS OTHERWISE SPECIFIED:
A
FINISH:
Bladder Kit comprising:
DEBUR AND

burst disc to protect the accumulator. See Installation and


DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
D
BREAK SHARP
Bladder assembly
EDGES
DO NOT SCALE DRAWING REVISION

TOLERANCES:
Servicing data sheet for information regarding installation of
LINEAR:
ANGULAR:
D1 Bladder
accumulators. NAME SIGNATURE DATE TITLE:
DRAWN D2 Gas valve assembly
CHK'D

8 Pressure Testing APPV'D D3 Locknut


D4 Protective cap
MFG
A hydro static pressure test is carried out on all our
TYPICAL ACC FOR WEB BROCHURE IN C
Q.A MATERIAL:
DWG NO.
A4
accumulator shells during the manufacturing process. We can D5 'O' ring stem
carry out additional pressure testing witnessed by a specified E Anti extrusion ring assembly
WEIGHT: 48.42 SCALE:1:10 SHEET 1 OF 1

Inspection Authority and/or customer as an optional extra if E1 Anti extrusion ring


required.
E2 'O' ring fluid port*
We can also carry out a hydro-pneumatic pressure test on the E3 Bonded seal
complete assembly as an optional extra if required. Again this E4 Back-up ring
can be witnessed by a specified inspection authority and/or
B Fluid port assembly comprising
customer.
B1 Fluid port body
9 Accessories B2 Spring
A complete range of accumulator accessories are available B3 Poppet valve
from Parker Olaer. B4 Collett
B5 Piston
10 Spare Parts
B6 Flanged washer
Available on request.
B7 Locking ring
B8 Bleed adaptor*
B9 Bleed valve*
C Shell assembly comprising:
C1 Shell
C2 Label
C3 Label warning
Note: Models 4/54 litres detailed above.

2 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
HY10-4009-DS/UK ASME Bladder Accumulators
How to Order Bladder Accumulators 207, 310, 345 & 420 bar

Litres Bladder Bladder Shell and Maximum Design


material stem/ gas fluid port working Number/
valve pressure Approval

Code Bladder Material


0 Nitrile standard
1 Butyl
2 Low temperature nitrile
Maximum Working
3 Low permeability nitrile
Code Pressure
6 Viton
20 207 bar
8 High temperature nitrile
27 276 bar
34 345 bar
42 420 bar

Code Volume Code


Shell and Fluid Port
04 4 207/276 345/420
bar bar
10 10
00 FJ Oil service
20 20
02 FH Low/medium corrosive service (lined shell)
37 37
13 FR Oil service (NPT connection)
54 54 (207 & 276 bar only)
14 FQ Low/medium corrosive service (lined shell, NPT connection)
57 57 (345 & 420 bar only)
W6 FS Stainless steel externals, unlined shell
CZ FD Stainless steel externals, unlined shell 1/2" NPT connection
(10-57 litre only)
DL FT Stainless steel externals, unlined shell 1/2” BSP connection
(10-57 litre only)

Design Standard/
Code Bladder Stem/Gas Valve Code Authority Approval
OB-OF 01-37L 54L 4 ASME VIII - ‘U’ coded
OA 5/8” UNF/1/4” BSPM 7/8” UNF/1/4” BSPM M50 x 1.5 / 1.4” BSPM CE mark of ASME
9A 5/8” UNF/302-32 7/8” UNF/302-32 7/8” UNF / 302-32 accumulators possible,
SA as OA but corrosive please contact us
service

Example: 5400A-00-204
Litres: 54
Bladder Material: Nitrile Standard
Bladder Stem/ Gas Valve: 5/8” UNF/1/4” BSPM
Shell & Fluid Port: Oil Service
Maximum working pressure: 207 bar
Design Number/Approval: ASME VIII - ‘U’ coded

3 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar

Capacities and Dimensions


Nominal Effective Work Max Weight Dimensions in mm unless stated otherwise and subject to manufacturer's tolerances
Capacity Gas vol. press. Flow Dry A B C D E F G H J K L M N P
Litres Litres bar Rate Kilo Inches Inches Inches
lt/min
04 3.8 207 477 15.00 ¼ BSP 7/8 UNF 34 78 455 289 171 74 1 ¼ BSPF 60 36 39 9 55
04 3.8 345 477 16.00 ¼ BSP 7/8 UNF 34 78 455 289 173 74 1 ¼ BSPF 60 36 39 9 55
04 3.8 420 477 16.00 ¼ BSP 7/8 UNF 34 78 455 289 173 74 1 ¼ BSPF 60 36 39 9 55
10 9.4 207 749 36.00 ¼ BSP 7/8 UNF 34 78 575 407 230 70 2 BSPF 76 36 46 9 69
10 9.4 276 749 36.00 ¼ BSP 7/8 UNF 34 78 575 407 230 70 2 BSPF 76 36 46 9 69
10 9.4 345 749 54.00 ¼ BSP 7/8 UNF 34 78 575 407 243 70 2 BSPF 76 36 46 9 69
10 9.4 420 749 54.00 ¼ BSP 7/8 UNF 34 78 575 407 243 70 2 BSPF 76 36 46 9 69
20 18.8 207 749 54.00 ¼ BSP 7/8 UNF 34 78 886 718 230 70 2 BSPF 76 36 46 9 69
20 18.8 276 749 54.00 ¼ BSP 7/8 UNF 34 78 886 718 230 70 2 BSPF 76 36 46 9 69
20 18.8 345 749 100.00 ¼ BSP 7/8 UNF 34 78 886 718 243 70 2 BSPF 76 36 46 9 69
20 18.8 420 749 100.00 ¼ BSP 7/8 UNF 34 78 886 718 243 70 2 BSPF 76 36 46 9 69
37 35.2 207 749 100.00 ¼ BSP 7/8 UNF 34 78 1407 1239 230 70 2 BSPF 76 36 46 9 69
37 35.2 276 749 100.00 ¼ BSP 7/8 UNF 34 78 1407 1239 230 70 2 BSPF 76 36 46 9 69
37 35.2 345 749 152.00 ¼ BSP 7/8 UNF 34 78 1407 1239 243 70 2 BSPF 76 36 46 9 69
37 35.2 420 749 152.00 ¼ BSP 7/8 UNF 34 78 1407 1239 243 70 2 BSPF 76 36 46 9 69
54 49.2 207 749 138.00 ¼ BSP M50x 1.5 70 66 1922 1766 230 70 2 BSPF 76 36 46 9 69
54 49.2 276 749 138.00 ¼ BSP M50x 1.5 70 66 1922 1766 230 70 2 BSPF 76 36 46 9 69
57 54.5 345 749 220.00 ¼ BSP M50x 1.5 70 66 1980 1824 243 70 2 BSPF 76 36 46 9 69
57 54.5 420 749 220.00 ¼ BSP M50x 1.5 70 66 1980 1824 243 70 2 BSPF 76 36 46 9 69

Note: Dimensions are based on current stock and are subject


to change without prior notice. A GAS VALVE

B STEM

C A/F
D

PROTECTIVE CAP ON 04L


AND ABOVE

D HEAD DETAIL 10/37L

F G

E F

DETAIL A
SCALE 1 : 2 HEAD DETAIL 54/57L
DEBUR AND
D
UNLESS OTHERWISE SPECIFIED: FINISH:
DO NOT SCALE DRAWING REVISION
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP
SURFACE FINISH: EDGES
TOLERANCES:
LINEAR:
ANGULAR:

NAME SIGNATURE DATE TITLE:


DRAWN

CHK'D

APPV'D

MFG P (A/F)
E
TYPICAL ACC FOR WEB BROCHURE GAS END N
Q.A MATERIAL:
A4 DWG NO.

(A/F)
F WEIGHT: 48.42 SCALE:1:10 SHEET 1 OF 1

H M

L
J
K

4 Parker Hannifin
DETAIL B Accumulator Cooler Division Europe
SCALE 1 : 2
Sandycroft, UK
UNLESS OTHERWISE SPECIFIED: FINISH: DEBUR AND
DO NOT SCALE DRAWING REVISION
UNLESS OTHERWISE SPECIFIED: FINISH: DEBUR AND
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP
DO NOT SCALE DRAWING
DIMENSIONS ARE IN MILLIMETERS BREAK SHARP REVISION
SURFACE FINISH: EDGES
SURFACE FINISH: EDGES
TOLERANCES: TOLERANCES:
LINEAR:
ANGULAR: LINEAR:
NAME SIGNATURE DATE
ANGULAR:
TITLE:
DRAWN

CHK'D
NAME SIGNATURE DATE TITLE:
APPV'D
DRAWN
MFG
HY10-4009-DS/UK ASME Bladder Accumulators
Features and Dimensions 207, 310, 345 & 420 bar

Accessories
A wide range of accessories are available for our accumulator range. Please refer to our accessories catalogue to find the suitable
items for your accumulator.

Accessories include:
• Charging Sets
• Safety Blocks
• Brackets and Clamps

Accumula
Accessorietors
2
s
07 bar to 6
90 bar ran
ge

5 Parker Hannifin
Accumulator Cooler Division Europe
Sandycroft, UK
Parker Worldwide
Europe, Middle East, Africa HU – Hungary, Budaoers North America
Tel: +36 23 885 470
AE – United Arab Emirates, parker.hungary@parker.com CA – Canada, Milton, Ontario
Dubai Tel: +1 905 693 3000
Tel: +971 4 8127100 IE – Ireland, Dublin
Tel: +353 (0)1 466 6370 US – USA, Cleveland
parker.me@parker.com
parker.ireland@parker.com (industrial)
AT – Austria, Wiener Neustadt Tel: +1 216 896 3000
Tel: +43 (0)2622 23501-0 IT – Italy, Corsico (MI)
Tel: +39 02 45 19 21 US – USA, Elk Grove Village
parker.austria@parker.com
parker.italy@parker.com (mobile)
AT – Eastern Europe, Wiener Tel: +1 847 258 6200
Neustadt KZ – Kazakhstan, Almaty
Tel: +43 (0)2622 23501 900 Tel: +7 7273 561 000 Asia Pacific
parker.easteurope@parker.com parker.easteurope@parker.com
AU – Australia, Castle Hill
AZ – Azerbaijan, Baku NL – The Netherlands, Oldenzaal Tel: +61 (0)2-9634 7777
Tel: +994 50 22 33 458 Tel: +31 (0)541 585 000
parker.azerbaijan@parker.com parker.nl@parker.com CN – China, Shanghai
Tel: +86 21 2899 5000
BE/LU – Belgium, Nivelles NO – Norway, Asker
Tel: +32 (0)67 280 900 Tel: +47 66 75 34 00 HK – Hong Kong
parker.belgium@parker.com parker.norway@parker.com Tel: +852 2428 8008
BG – Bulgaria, Sofia PL – Poland, Warsaw ID – Indonesia, Tangerang
Tel: +359 2 980 1344 Tel: +48 (0)22 573 24 00 Tel: +62 21 7588 1906
parker.bulgaria@parker.com parker.poland@parker.com IN – India, Mumbai
BY – Belarus, Minsk PT – Portugal, Leca da Palmeira Tel: +91 22 6513 7081-85
Tel: +375 17 209 9399 Tel: +351 22 999 7360 JP – Japan, Fujisawa
parker.belarus@parker.com parker.portugal@parker.com Tel: +81 (0)4 6635 3050
CH – Switzerland, Etoy RO – Romania, Bucharest KR – South Korea, Seoul
Tel: +41 (0)21 821 87 00 Tel: +40 21 252 1382 Tel: +82 2 559 0400
parker.switzerland@parker.com parker.romania@parker.com
MY – Malaysia, Shah Alam
CZ – Czech Republic, Klecany RU – Russia, Moscow Tel: +60 3 7849 0800
Tel: +420 284 083 111 Tel: +7 495 645-2156
parker.czechrepublic@parker.com parker.russia@parker.com NZ – New Zealand, Mt Wellington
Tel: +64 9 574 1744
DE – Germany, Kaarst SE – Sweden, Spånga
Tel: +49 (0)2131 4016 0 Tel: +46 (0)8 59 79 50 00 SG – Singapore
parker.germany@parker.com parker.sweden@parker.com Tel: +65 6887 6300
DK – Denmark, Ballerup SK – Slovakia, Banská Bystrica TH – Thailand, Bangkok
Tel: +45 43 56 04 00 Tel: +421 484 162 252 Tel: +662 717 8140
parker.denmark@parker.com parker.slovakia@parker.com TW – Taiwan, New Taipei City
ES – Spain, Madrid SL – Slovenia, Novo Mesto Tel: +886 2 2298 8987
Tel: +34 902 330 001 Tel: +386 7 337 6650 VN – Vietnam, Ho Chi Minh City
parker.spain@parker.com parker.slovenia@parker.com Tel: +84 8 3999 1600
FI – Finland, Vantaa TR – Turkey, Istanbul
Tel: +358 (0)20 753 2500 Tel: +90 216 4997081
parker.turkey@parker.com
South America
parker.finland@parker.com
AR – Argentina, Buenos Aires
FR – France, Contamine s/Arve UA – Ukraine, Kiev
Tel: +54 3327 44 4129
Tel: +33 (0)4 50 25 80 25 Tel +380 44 494 2731
parker.france@parker.com parker.ukraine@parker.com BR – Brazil, Cachoeirinha RS
Tel: +55 51 3470 9144
Ed. 2013-08-01

GR – Greece, Athens UK – United Kingdom, Warwick


Tel: +30 210 933 6450 Tel: +44 (0)1926 317 878 CL – Chile, Santiago
parker.greece@parker.com parker.uk@parker.com Tel: +56 2 623 1216
ZA – South Africa, Kempton Park MX – Mexico, Toluca
Tel: +27 (0)11 961 0700 Tel: +52 72 2275 4200
parker.southafrica@parker.com

© 2013 Parker Hannifin Corporation. All rights reserved. HY10-2009-DS/UK, POD, 08/2013, ZZ

EMEA Product Information Centre


Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL,
IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)
US Product Information Centre
Toll-free number: 1-800-27 27 537
www.parker.com Your local authorized Parker distributor
PROTECTOSEAL
FLAME ARRESTOR
ITEM1: FA
SERIES 670 / 6670
End-of-Line Deflagration Flame Arrester
Suitable for use with NEC Group D (IEC Explosion Group IIA) Vapors PROTECTOSEAL ®

G Sizes 1" through 4"


G Listed by Underwriters Laboratories in 1" and 2” sizes
G Suitable for use with vapors equivalent to NEC 500
Group D, IEC Group IIA
G Vertically mounted, parallel plate-type flame arrester
G Protects against fire
G Minimizes pressure drop under normal operating
conditions
G Easy inspection and maintenance
G Factory inspected prior to shipment
G Available in Aluminum and Stainless Steel

OBJECTIVE Automatic Condensate Drainage. Vertically mounted, circular


The Series 670/6670 Flame Arresters are designed to plate-type flame arrester is employed for self-drainage of
provide flame stopping protection for a tank’s vapor space condensate. This prevents accumulation of condensate
when mounted to the end of a tank nozzle leading directly to subject to freezing and consequent clogging of the arrester
atmosphere. The arresters prevent a flame front generated under low temperature conditions.
by an unconfined deflagration occurring outside the tank from Positive Flame Arresting. The Series 670/6670 employs a
propagating into the vapor space. circular-plate, precisely-spaced, type flame arrester to protect
tank contents by preventing the propagation of fire into the
tank. Precision embossings on alternate plates provide
correct air-spacing for flame arresting function. Plates are
fabricated from 1⁄ 16" to 3⁄ 32" heavy gauge metal, depending on
material of construction, to resist distortion and bending
during cleaning.
Sizes Available. 1", 2", 3" and 4" have standard NPT female
threaded connections. Adapter flanges are available in these
sizes. Refer to dimension chart on reverse for flange connec-
tion details. Refer to Series 670E for 6” size.
Test Lab Listings. Listed by Underwriters Laboratories (UL) in
1" and 2” sizes. For arresters that meet ATEX Directive
94/9/EC Standards EN 12874 & ISO 16852, please refer to
VAPOR GROUPS Series 670E.
The arresters are intended for use with vapors equivalent to PRO-FLOW III® Sizing and Selection Software. Use
Group D of the National Electric Code (NEC 500), IEC Group PRO-FLOW III® to calculate flame arrester flow requirements
IIA. For arresters suitable for use with NEC Group C, IEC in accordance with API 2000, ISO 28300, NFPA 30 and
Group IIB3, please refer to Protectoseal Series 670E. OSHA 1910.106.
TECHNIQUE Quality Assurance. Each unit is inspected to meet
The arrester is mounted on the end of a vent pipe from the Protectoseal’s high standards prior to shipment.
tank. Vapors are allowed to escape into the atmosphere and
air can be drawn into the tank through the specially designed CONSTRUCTION
flame arrester grid assembly. If an ignition source outside the A comprehensive range of materials is offered as shown in
tank is encountered, the flame arrester provides protection for the chart below. Other materials and features can be furnished
the tank contents. upon request.
Available Options.
® Material certifications for castings
SPECIAL FEATURES
Easy Inspection, Installation and Maintenance. Design and
light weight of unit permit easy, convenient handling for Nipple Flame Arrester
inspection, installation and maintenance. The weatherhood is Series Body Hood Flange Grid Assembly
readily removable by loosening just a few extra large wing
nuts. 670 Aluminum Aluminum Aluminum Aluminum
6670 Aluminum Aluminum Aluminum Aluminum
F670 316 S.S. 316 S.S. 316 S.S. 316 S.S.
FF6670 316 S.S. 316 S.S. 316 S.S. 316 S.S.
NOTE: Aluminum flanged to mate with 125# ANSI FF flanges. 316 S,S. models mate with 150#
ANSI RF flanges.

www.protectoseal.com
Specifications Series 670 / 6670
End-of-Line Deflagration Flame Arrester

Suitable for use with For arresters


NEC Group D suitable for use with
chemical vapors, NEC Group C,
generally equivalent IEC Group IIB3,
to Electrotechnical please refer to
Commission (IEC) Protectoseal
Group IIA Series 670E

E,N

DIMENSIONS (NOTE: Dimensions shown are for reference only, contact Factory for certified drawings.)
Connection Ht Dia B.C Dia. Holes Type
Cat. No.* FNPT ANSI** DIN 16 PN A C D E N Approval
671 1" 1- 1- 12.88" (73mm) 13.38" (86mm) - - - UL
671F - 11" 1- 14.4" (112mm) 13.38" (86mm) 3.13" (80mm) .63" (16mm) 4 UL
See Series 670E - 1- 1DN 25 1- 1- - - - Note 1
6672 2" 1- 1- 14.63" (117mm) 16.13" (156mm) - - - UL
6672F - 12" 1- 17"(178mm) 16.13" (156mm) 4.75" (120mm) .75" (19mm) 4 UL
See Series 670E - -- 1DN 50 1- 1- - - - Note 1
673B 3" 1- 1- 18" (203mm) 17.5" (191mm) - - - -
673BF - 13" 1- 19.88" (251mm) 17.5" (191mm) 6" (152mm) .75" (19mm) 4 -
See Series 670E - 1- 1DN 80 1- 1- - - - Note 1
674 4" 1- 1- 17.38" (187mm) 18.5" (216mm) - - - -
674F - 14" 1- 19.38" (238mm) 18.5" (216mm) 7.5" (190mm) .75" (19mm) 8 -
See Series 670E - 1- 1DN 100 1- 1- - - - Note 1
* Cat. No. designates all Aluminum construction, please refer to chart on reverse for other materials.
** Aluminum flanged to mate with 125# ANSI FF flanges. 316 S,S. models mate with 150# ANSI RF flanges.
Note 1: Type Approved according to ATEX Directive 94/9/EC, Standards EN 12874 and ISO 16852 (Refer to Protectoseal Series 670E)

For larger sizes. . . Refer to Protectoseal Series No. 860 or Series No. 670E

ADDITIONAL PRODUCTS FROM PROTECTOSEAL


Series 670E (Group C, IIB3) Series 860 (Group D, IIA) Series 18540 Series 830

Type Approved according to End-of-Line Deflagration Flame Pipe-Away Pressure Vacuum Combination Pressure / Vacuum
ATEX Directive 94/9/EC, Arrester provides protection of Relief Vent for applications that Relief Vent & Flame Arrester
Standards EN 12874 and ISO the tank’s vapor space if an require hazardous vapors be provides pressure and vacuum
16852. Suitable for use with ignition source is introduced out- processed into manifolded relief as well as protection from
NEC Groups C or D side of the tank. Suitable for piping and not released into the propagation of externally intro-
(IEC Groups IIB3 or IIA). NEC Group D (IEC Group IIA) atmosphere. duced flames. Suitable for NEC
vapors. Group D (IEC Group IIA) vapors.

PROTECTOSEAL
Safety Without Compromise
®
225 Foster Ave., Bensenville, IL 60106-1690
P 630.595.0800 F 630.595.8059
info@protectoseal.com www.protectoseal.com

©2012 The Protectoseal Company V-670/6670/4


BIFOLD FLUIDPOWER
SOLENOID VALVE
ITEM1: SV‐2880‐2, SV‐2880‐3, SV‐29XX‐1, SV‐29XX‐2, SV‐29XX‐3, SV‐30XX‐1

2 WAYS MANIFOLD
ITEM2: NV1, MNV1
Global Presence for
Peace of Mind

Direct and Indirect Acting Solenoid Valves


Models FP03P, FP06P, FP10P, FP12P,
SJ06, S06, S09, S12 & SPR

Superior Performance Throughout the Full Operational Range

Solenoid Valve Worldwide Solenoid Approvals


SIL 3 Third Party Certified Ex d, Ex ia, Ex emb, explosion proof
Solenoid Free to Rotate ATEX Registered

Through 360º
Low Power
316L Stainless Steel Solenoid
Housing and Valve High Flow

Arctic Service Options to -60ºC Up to 35 bar Working Pressure

Innovative and Reliable


www.bifold.co.uk
Valve Solutions
Solenoid Valve Range

Features & Benefits


Worldwide Approvals

Standard Solenoids

ATEX Equipment Design & Build

Worldwide Approval
Registered

Solenoid Operator is Free to Rotate 360º Solenoid operator and mounting block (patent
pending) are free to rotate 360º allowing for an easy
cable layout and ease of connection wiring. Solenoid
internals rotate with operator and prevent cables
being pulled out of terminal block.

Widest range of override options (Auto Reset,


Spring Return Manual Override, Stayput Manual
Override, Manual Reset, Tamperproof Manual Latch,
Latch Energised).
Widest Range of Override Options

Worldwide technical and field support.

Standard solenoid valve can be mounted in any


orientation to simplify installation due to all the
components having enhanced rotational capabilities.
Valve can be Mounted in any Orientation
Commissioning and Maintenance Benefits for
the Standard Solenoid

Tropicalised solenoid design - all 316L stainless steel


construction including magnetic parts. Fully
encapsulated coil.
Spacious Enclosure for Ease of Wiring

Spacious solenoid enclosure for ease of wiring.

No time penalty for heat dissipation before


removing solenoid cover.

No special high temperature cable requirements.

Internal Earth Surge Suppression Terminal Block


Connection Diode Ex d (dc)

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
2 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Features & Benefits


Worldwide Approvals

Slimline Solenoids

ATEX Equipment Design & Build

Registered
Worldwide Approvals.

Solenoid Operator is Free to Rotate 360º Solenoid operator is free to rotate 360º allowing for
an easy cable layout and ease of connection wiring.
Solenoid internals rotate with operator and prevent
cables being pulled out of terminal block.

Carbon steel solenoid operator, coated for offshore


applications as well as a 316L stainless steel solenoid
housing option.

Override Options Override Options - Auto Reset, Manual Override and


Manual Reset.

Worldwide technical and field support.

Solenoid valve can be mounted in any orientation to


simplify installation.
Valve Assembly can be Mounted in any
Orientation
Commissioning and Maintenance Benefits for the
Slimline Solenoids

Tropicalised solenoid design - Fully encapsulated coil.

Compact Enclosure Design No time penalty for heat dissipation before removing
solenoid cover.

No special high temperature cable requirements.

Compact design and space envelope.

Coil Leads

Incoming Supply Leads Terminal Block


Connect +Ve To Red Coil Lead Surge Suppression
Connect –Ve To Black Coil Diode Ex d (dc)

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
3
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Features & Benefits


SIL certified, FMEA, extensive qualification testing coupled with 100% Computerised Diagnostic Test
Procedures.

Safety and Environmental Benefits

Standard solenoid operator has SIL third party certification to


IEC 61508, FMEA, extensive qualification testing.

Balanced valve with high safety factors to de-energise


at all pressures in Normally Open and Normally
Closed configurations.

100% computerised diagnostic testing to ensure each


solenoid valve is proven along with confirmed safety
factors.

Bifold has state of the art testing and qualification


equipment including endurance, environment, climatic,
performance, function and leakage testing.

State of the Art Testing The standard solenoid operator is a holding magnet
type which ensures the valve will operate in damp
conditions. The risk of corrosion to internal
components is reduced, unlike other valve types that
incorporate a solenoid core tube design with a
'wetted' armature that will only operate in dry air
conditions!

Tolerant to moist air in control lines.

The standard solenoid operator has proven arctic


services and low temperature performance.

Products are manufactured, inspected, assembled and


tested in our state of the art production facilities.

Large clearances, metal back up to seals and no knife


edge sealing to prevent long term valve sticking.

Dry armature to prevent armature corrosion affecting


Simple Maintenance safe shut down.

Simple maintenance - Removable transient


suppression diode and solenoid coil without removing
valve from the tubing.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
4 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Selection Table

DIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number
1⁄8" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Closed, 24Vdc, Auto Reset.
FP03P-02-32-NC-V-74A-24D-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NC IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.1, 10 bar.
15
1
ATEX II 2 GD, Ex d IIC T6
2
FP03P-02-32-NC-V-77A-24D-30 IECEx Ex d IIC T6
3
3.0 Watt, Cv 0.1, 10 bar.

FP03P ATEX II I GD, Ex ia IIC T6 Ga


FP03P-02-32-NC-V-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.1, 10 bar.
1⁄8" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Closed, 24Vdc, Manual Reset.
FP03P-02-32-NC-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NC
IECEx Ex emb IIC T3 Gb
R 3.6 Watt, Cv 0.1, 10 bar.
15
1
ATEX II 2 GD, Ex d IIC T6
2
3
FP03P-02-32-NC-V-77A-24D-ML-30 IECEx Ex d IIC T6
3.0 Watt, Cv 0.1, 10 bar.
FP03P ATEX II I GD, Ex ia IIC T6 Ga
Manual Reset
FP03P-02-32-NC-V-78A-ML-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.1, 10 bar.
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
FP06P-S1-04-32-NU-V-74A-24D-36 Normally Universal, 24Vdc, Auto Reset.
ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NU FP06P-S1-04-32-NU-V-74A-24D-44 IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.4, 10 bar.
FP06P-S1-04-32-NU-V-74A-24D-68 4.4 Watt, Cv 0.5, 10 bar.
16
1
2 6.8 Watt, Cv 0.75, 10 bar.
3
ATEX II 2 GD, Ex d IIC T6
FP06P-S1-04-32-NU-V-77A-24D-35
IECEx Ex d IIC T6
FP06P FP06P-S1-04-32-NU-V-77A-24D-57
3.5 Watt, Cv 0.5, 10 bar.
5.7 Watt, Cv 0.75, 10 bar.

¼" NPT Ports, 3 Way 2 Position, Direct Acting,


Normally Universal, 24Vdc, Manual Reset.

SCHEMATIC 3/2 NU FP06P-S1-04-32-NU-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb


R IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.75, 10 bar.
16
1
2
3

ATEX II 2 GD, Ex d IIC T6


FP06P FP06P-S1-04-32-NU-V-77A-24D-ML-30 IECEx Ex d IIC T6
Manual Reset 3.0 Watt, Cv 0.75, 10 bar.

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
5
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Selection Table

DIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

SCHEMATIC 3/2 NU ¼" NPT Ports, 3 Way 2 Position, Direct Acting,


Normally Universal, 24Vdc, Auto Reset.
17 FP06P-SI-04-32-NU-V-58A-135 ATEX II 1G Ex ia, IIC T6 Ga
1
2
IECEx Ex ia IIC T6 Ga
3
135 Ohms, Cv 0.5, 10 bar. †
FP06P
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
FP10P-SI-04-32-NU-V-74A-24D-36 Normally Universal, 24Vdc, Auto Reset.
ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NU
FP10P-SI-04-32-NU-V-74A-24D-44 IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.4, 10 bar.
18 FP10P-SI-04-32-NU-V-74A-24D-68 4.4 Watt, Cv 0.5, 10 bar.
1
2 6.8 Watt, Cv 0.75, 10 bar.
3
ATEX II 2 GD, Ex d IIC T6
FP10P-SI-04-32-NU-V-77A-24D-35 IECEx Ex d IIC T6
FP10P 3.5 Watt, Cv 0.5, 10 bar.
FP10P-SI-04-32-NU-V-77A-24D-57
5.7 Watt, Cv 0.75, 10 bar.
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
SCHEMATIC 3/2 NU
Normally Universal, 24Vdc, Manual Reset.
FP10P-SI-04-32-NU-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
R
IECEx Ex emb IIC T3 Gb
18 3.6 Watt, Cv 0.75, 10 bar.
1
2
3
ATEX II 2 GD, Ex d IIC T6
FP10P FP10P-SI-04-32-NU-V-77A-24D-ML-30 IECEx Ex d IIC T6
Manual Reset 3.0 Watt, Cv 0.75, 10 bar.

SCHEMATIC 3/2 NU
½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Auto Reset.
1
19 FP12P-S1-08-32-NU-V-77A-24D-120 ATEX II 2 GD, Ex d IIC T6
2
3 IECEx Ex d IIC T6
12 Watt, Cv 2.5, 10 bar.

FP12P

SCHEMATIC 3/2 NU
R ½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Manual Reset.
19 FP12P-S1-08-32-NU-V-77A-24D-ML-65
1
2 ATEX II 2 GD, Ex d IIC T6
3 IECEx Ex d IIC T6
6.5 Watt, Cv 2.5, 10 bar.
FP12P
Manual Reset

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
6 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Selection Table

INDIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

¼" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Auto Reset.
SJ06-EI-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC
ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T 3.6 Watt, Cv 0.7, 10 bar.

20
3
ATEX II 2 GD, Ex d IIC T6
2 SJ06-EI-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1 3.0 Watt, Cv 0.7, 10 bar.

SJ06 ATEX II I GD, Ex ia IIC T6 Ga


SJ06-EI-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.7, 10 bar.

¼" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed 24Vdc, Manual Reset.
SJ06-E5-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
R
IECEx Ex emb IIC T3 Gb
T
3.6 Watt, Cv 0.7, 10 bar.
20
3 ATEX II 2 GD, Ex d IIC T6
2
SJ06-E5-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 0.7, 10 bar.

SJ06
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
SJ06-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 0.7, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Auto Reset.
S12-E1-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T 3.6 Watt, Cv 1.7, 10 bar.

21
3
2
ATEX II 2 GD, Ex d IIC T6
S12-E1-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
3.0 Watt, Cv 1.7, 10 bar.
1

S12
ATEX II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
S12-E1-32-NC-00-78A-370
370 Ohms, Cv 1.7, 10 bar. †

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
7
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Selection Table

INDIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Manual Reset.
S12-E5-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T R 3.6 Watt, Cv 1.7, 10 bar.

21
3 ATEX II 2 GD, Ex d IIC T6
2
S12-E5-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 1.7, 10 bar.
S12
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
S12-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 1.7, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Universal, 24Vdc, Auto Reset.
SPR12-E1-32-NU-00-74A-24D-36
SCHEMATIC 3/2 NU ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 3.0, 10 bar.
T

22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E1-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E1-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 3.0, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Universal, 24Vdc, Manual Reset.
SPR12-E5-32-NU-00-74A-24D-36
SCHEMATIC 3/2 NU
ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T R 3.6 Watt, Cv 3.0, 10 bar.

22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E5-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
Manual Reset
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E5-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 3.0, 10 bar. †
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
8 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Overview
Materials of Construction

Solenoid housing and valve manufactured from 316L stainless steel as standard.
Valve seals are supplied in Viton as standard. Alternative elastomers available for extreme conditions and to suit media.
Springs are manufactured from 302S26 & 316S42 stainless steel as standard.
Fasteners are metric A4 18/10 grade stainless steel; equivalent to 316L grade stainless steel.

Technical Data

Operating Performance for FP03P, FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR
Duty cycle 100% continuously rated/energised.
Surge suppression diode is fitted on all Ex d dc solenoid coils as standard.
Response times - pull in <100ms, drop out <70ms.
Solenoid Insulation - Class H.
Pull-in volts to 85% of nominal. (Checked at FAT to be within specified limits to guarantee safety factors).
Maximum volts at 110% of nominal.
Drop-out volts typically 10 - 20% of nominal (higher Volt options for line monitoring). (Checked at FAT to be within
specified limits to guarantee safety factors).
Temperature rating -20ºC to upper limit of solenoid classification (standard). Arctic service option to -60ºC.
IP66 & IP67 Ingress Protection to IEC 60529 and NEMA 4X.
Bifold solenoid valves must be installed, operated and maintained in accordance with the relevant Bifold installation, operating
and maintenance instructions, relevant installation rules, regulations and codes of practice.

Product Options
Certification & Approval options available Certification & Approval options available
for standard 7 series solenoid housing for slimline 5 series solenoid housing

ATEX Registered ATEX Registered

SIL 3, Safety Integrity Level, third party certification to IEC 61508 (Valve models FP03P, FP06P & FP10P. Note: FP03P fitted as
the pilot stage operator on SJ06, S06, S09, S12 & SPR).
Valves can be mounted in any orientation. Solenoids can be rotated relative to the pilot stage valve body to suit cable entry.
Working pressure up to 35 bar. Maximum working pressure according to valve model.
Operating media - Filtered lubricated or unlubricated air, inert gas, sweet (natural) and sour gas options, water,
water glycol mixtures and mineral oil. Maximum viscosity 65 cSt (mm²/s).
For operating temperature range, please see solenoid valve type and seal options.
Higher voltage options available for line monitoring.
Manual Reset, Manual Override and Manual Latch operator options.
Arctic Service options to -60ºC.
These products can be incorporated within our 'AXIS' valve actuator control manifold systems.
See catalogue 03: - AXIS Manifold System.

Typical 'AXIS' valve actuator control manifold assembly

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
9
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Certification & Approvals

Certification Details
Certification & Approval Details
Type 74 Solenoid
ATEX, Certificate Number Baseefa 09ATEX0040X. IECEx, Certificate Number IECEx Bas 09.0012X.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +40ºC. Ex emb IIC T3 Gb Tamb -25ºC to +40ºC.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +55ºC. Ex emb IIC T3 Gb Tamb -25ºC to +55ºC.
Dual Labelled/Marked
Type 77 Solenoid
ATEX, Certificate Number Baseefa 10ATEX0026. IECEx, Certificate Number IECEx Bas 10.0008.
II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC). Ex d IIC T6 (Tamb -60ºC to +40ºC).
II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC). Ex d IIC T5 (Tamb -60ºC to +55ºC).
II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC). Ex d IIC T4 (Tamb -60ºC to +90ºC).
Dual Labelled/Marked
Type 58 Solenoid
ATEX, Certificate Number Baseefa 08ATEX0292X. IECEx, Certificate Number IECEx Bas 08.0095X.
II 1G Ex ia IIC T6 Ga (-40ºC ≤ Ta ≤ +60ºC). Ex ia IIB T6 Ga (-40ºC ≤ Ta ≤ +60ºC).
Dual Labelled/Marked
Type 78 Solenoid
ATEX, Certificate Number Baseefa 02ATEX0124X. IECEx, Certificate Number IECEx Bas 09.0092X.
II I GD Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC). Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC).
II I GD Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC). Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC).
Dual Labelled/Marked
Type 77 Solenoid Type 77 Solenoid
CSA (US), Certificate Number 1398692 ATEX, Certificate Number Baseefa 10ATEX0026.
Class 1, Division 1, Groups B, C & D for both II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC).
Canada & USA. II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC).
Ex d IIC for Canada, AEx d IIC for USA.
T85ºC -60ºC to +40ºC ambient. II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC).
T100ºC -60ºC to +55ºC ambient.
T135ºC -60ºC to +90ºC ambient.
Dual Labelled/Marked
Type 58 Solenoid Type 58 Solenoid
INMETRO, Certificate Number CEPEL 12.2125X. GOST, Certificate Number B0015, RTN Permit
BR-Ex ia IIB T6 -40ºC to +60ºC ambient. Number PPC 00-048112
0Ex ia IIC T6 -40ºC to +40ºC ambient.
Type 77 Solenoid 0Ex ia IIC T5 -40ºC to +55ºC ambient.
INMETRO, Certificate Number CEPEL-EX-097/2003X. 0Ex ia IIC T4 -40ºC to +60ºC ambient.
BR-Ex d IIC T6 -60ºC to +40ºC ambient. Type 77 Solenoid
BR-Ex d IIC T5 -60ºC to +55ºC ambient. GOST, Certificate Number B00763, RTN.
BR-Ex d IIC T4 -60ºC to +90ºC ambient. Ex d IIC T6 -60ºC to +40ºC ambient.
Ex d IIC T5 -60ºC to +55ºC ambient.
Type 78 Solenoid Ex d IIC T4 -60ºC to +90ºC ambient.
INMETRO, Certificate Number CEPEL-EX-532/05.
Type 78 Solenoid
BR-Ex ia IIC T6 -60ºC to + 40ºC ambient.
GOST, Certificate Number B00015, RTN.
BR-Ex ia IIC T4 -60ºC to + 95ºC ambient.
Permit Number PPC 00-28504.
Ex ia IIC T6 -60ºC to +40ºC ambient.
Type 87 Solenoid Ex ia IIC T5 -60ºC to +55ºC ambient.
NEPSI, Certificate Number GYJ081011. Ex ia IIC T4 -60ºC to +90ºC ambient.
Ex d IIC T6 up to 40ºC ambient. Type 77 & 78 Solenoid
Ex d IIC T5 up to 55ºC ambient.
Ex d IIC T4 up to 95ºC ambient. GOST K, GGTN K Permit, Kazakhstan,
BIF 7727 2.
Label Rationalisation
The temperature details on our solenoid labels have, to date, been These are in the process of being replaced with a single label which
laid out with a single ambient range and 'T' rating, as follows :- covers all potential temperature parameters.Therefore the label
will for example, read as follows :-

{
77A3 - T4 (-60ºC ≤ Tamb ≤ +90ºC) T4 (-60ºC ≤ Tamb ≤ +90ºC) {
or 77A6 - T5 (-60ºC ≤ Tamb ≤ +55ºC) 77A T5 (-60ºC ≤ Tamb ≤ +55ºC)
or 77A9 - T6 (-60ºC ≤ Tamb ≤ +40ºC) T6 (-60ºC ≤ Tamb ≤ +40ºC)
Please note that operation ambients are dependant upon seal types.
For solenoid type 87 please note that the solenoid housing is fixed.
For solenoid type 74 the maximum permissible ambient temperature is subject to the coil wattage. Please see page 12.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
10 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Product Options

Port Connections
Port Connections for
Port Connections (FP03P Only) (FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR)
PORT CONNECTIONS TABLE PORT CONNECTIONS TABLE
Configuration Pressure Service Vent Configuration Pressure Service Vent

Normally Closed 1 2 3 Normally Closed 1 2 3


For port connections please refer to selection chart ordering Normally Open 3 2 1
example. Page 15 Selector 1&3 2 N/A
Diverter 2 1&3 N/A
Product Weights For port connections please refer to selection chart ordering
example. Pages 16, 17, 18, 19, 20, 21 & 22
Approximate Standard Product Weights
PRODUCT WEIGHTS Seal Repair Kit
Product Approximate Weight (Kg) Seal Repair Kit Selection Chart - Ordering Example
(FP03P, FP06P, FP10P & FP12P)
FP03P 1.75 Seal Repair Kit
SRK
FP06P 2.1 FP03P
FP10P 2.5 FP06P
FP10P Model Code
FP12P 3.0 FP12P
SJ06 2.7 S Nitrile (-20ºC to +130ºC)
S06/S09/S12 3.4 V Viton (Standard) (-20ºC to +180ºC)
AG Silicone (-60ºC to +180ºC) O-ring Material
SPR 3.2 AL Fluorosilicone (-60ºC to +180ºC)

Solenoid Coil Spare Ordering Example


SRK FP06P V
Solenoid Coil Spare Selection Chart For SJ06, S06/S09/S12 & SPR, please contact Bifold Sales Department.
Ordering Example Type 74 & 77
109
XXX Voltage 74 (Ex emb) 24 & 48 Vdc
Coil Type Solenoid Coil Spare
77 (Ex d) 12,24,48 &110 Vdc Voltage
77 (Ex d) 110 & 240Vac Solenoid Coil Spare Selection Chart
XX Power (W) 74 (Ex emb) 1.8,3.6,4.4 & 6.8Watts
Power Ordering Example Type 58
77 (Ex d) 3.0,3.5,5.7 & 12Watts
58 Coil Type
XX Resistance (Ω) 58 (Ex ia) 370 Ohms Resistance

109 24DC 30 Ordering Example


For solenoid operator Type 77 (Ex d) Vac, the coil
spare ordering example is shown below:- 58 370 Ordering Example
109 110AC 57
For more information, please contact Bifold Sales Department.

Solenoid Coil Spare


Solenoid Coil Spare Selection Chart
Ordering Example Type 78
109 Coil Type
XXX Nominal Voltage 78 (Ex ia) 12 Nominal Voltage
XX Resistance (Ω) 78 (Ex ia) 370 Ohms Resistance

109 12 370 Ordering Example

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
11
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Options

Ex emb Options
Options Table 1 74 (Ex emb)
SOLENOID OPTIONS TABLE 1 74 (Ex emb)
Solenoid Typical Power Cable
Product Standard CV Temperature Ingress
Order Apparatus Consumption Entry Certification Options
Type Voltage Rate Range (ºC) Protection
Code Code (W) Connection
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 -25ºC to +55ºC
24 Vdc IP66 M20 x 1.5
Ex emb II Ambient
74 0.1 -25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
T3 -25ºC to +55ºC (T3) NEMA 4X Option)
48 Vdc Media #
-20ºC to +40ºC
3.6 -25ºC to +40ºC
FP03P Ambient
-25ºC to +40ºC (T3)

3.6 0.4
24 Vdc Media #
-20ºC to +40ºC IP66 M20 x 1.5
4.4 0.5 -25ºC to +40ºC IP67 (½" NPT ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
Ex emb II 6.8 0.75
FP06P
74 T3
3.6 0.4 Media #
24 Vdc -20ºC to +40ºC M20 x 1.5
IP66
-25ºC to +40ºC (½" NPT
4.4 0.5 IP67 ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
6.8 0.75
FP10P
Media #
-20ºC to +40ºC
-25ºC to +40ºC
1.8 -20ºC to +55ºC
0.7 -25ºC to +55ºC
24 Vdc Ambient IP66 M20 x 1.5
-25ºC to +40ºC (T3) IP67 (½" NPT
-25ºC to +55ºC (T3) ATEX IECEx
Media # NEMA 4X Option)
48 Vdc
-20ºC to +40ºC
3.6 0.7 -25ºC to +40ºC
SJ06 Ambient
Ex emb II -25ºC to +40ºC (T3)
74 T3 Media #
-20ºC to +40ºC
1.0 (S06) -25ºC to +40ºC
1.8 -20ºC to +55ºC
1.7 (S09) -25ºC to +55ºC
24 Vdc Ambient M20 x 1.5
1.7 (S12) IP66
-25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
-25ºC to +55ºC (T3)
NEMA 4X Option)
48 Vdc 1.0 (S06) Media #
-20ºC to +40ºC
3.6 1.7 (S09) -25ºC to +40ºC
S06, S09 & S12 Ambient
1.7 (S12) -25ºC to +40ºC (T3)
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 3.0 -25ºC to +55ºC
24 Vdc
Ex emb II Ambient
74 -25ºC to +40ºC (T3) IP66 M20 x 1.5
T3 -25ºC to +55ºC (T3)
IP67 (½" NPT ATEX IECEx
48 Vdc
NEMA 4X Option)
SPR Media #
3.0 -20ºC to +40ºC
3.6 -25ºC to +40ºC
Ambient
-25ºC to +40ºC (T3)

For detailed information on certification please see page 10.


Other Wattages available upon request.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
12 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Options

Ex d Options
Options Table 2 77 (Ex d)
SOLENOID OPTIONS TABLE 2 77 (Ex d)
Solenoid Typical Power Temperature Cable
Product Standard CV Ingress
Order Apparatus Consumption Range (ºC) Entry Certification Options
Type Voltage Rate Protection
Code * Code (W) Media Ambient Connection
12 Vdc ATEX IECEx
Media #
24 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ex d IIC 110 Vdc
77 0.1 IP67 (½" NPT GOST K GGTN
T6, T5 Ambient
Option)
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4)
*
FP03P PESO
12 Vdc Media # ATEX IECEx
24 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) GOST
110 Vdc IP66 M20 x 1.5
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5)
Ex d IIC * NEPSI
FP06P 50 or 60 Hz -60ºC to +90ºC (T4)
77 T6, T5 PESO
or T4 ATEX IECEx
24 Vdc Media #
48 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
110Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
FP10P PESO

24 Vdc Media # ATEX IECEx


48 Vdc -20ºC to +90ºC (T4) INMETRO
Ex d IIC 110Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
77 T6, T5 12 2.5 Ambient IP67 (½" NPT GOST K GGTN
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
FP12P PESO

24 Vdc Media # ATEX IECEx


48 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
110 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
0.7 Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5)
* NEPSI
Ex d IIC 50 or 60 Hz -60ºC to +90ºC (T4)
SJ06 PESO
77 T6, T5
or T4 1.0 (S06) Media ATEX IECEx
24 Vdc #
48 Vdc 1.5 ~ 1.7 (S09) -20ºC to +90ºC (T4) INMETRO
110 Vdc 1.7 (S12) -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ambient IP67 (½" NPT GOST K GGTN
110 Vac 1.0 (S06) -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 1.7 (S09) -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
S06, S09 & S12 1.7 (S12) PESO

24 Vdc Media # ATEX IECEx


48 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
Ex d IIC 110 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
77 T6, T5 3.0 Ambient IP67 (½" NPT GOST K GGTN
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5)
SPR 50 or 60 Hz -60ºC to +90ºC (T4) * NEPSI
PESO

For detailed information on certification please see page 10. * For China (NEPSI), please note that the solenoid operator is Type 87.
Other wattages available upon request. ~ Non standard low power option.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
13
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Options

Ex ia Options
Options Table 3 58 & 78 (Ex ia)

SOLENOID OPTIONS TABLE 3 58 & 78 (Ex ia)

Solenoid
Typical Cable
Product Order CV Temperature Ingress
Apparatus Entry Certification Options
Type Code Rate Range Protection
Code Connection

Media #
-20ºC to +95ºC
-60ºC to +95ºC ATEX IECEx
Ex ia IIC IP66 M20 x 1.5 INMETRO
58 † 0.5
T6 Ambient GOST
-40ºC to +60ºC
FP06P

Media #
-20ºC to +95ºC
IP66 M20 x 1.5 ATEX IECEx
-60ºC to +95ºC
Ex ia IIC IP67 (½" NPT INMETRO
78 † T6 or T4 0.1 Ambient NEMA 4X Option) GOST
-60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
FP03P

Media #
-20ºC to +95ºC ATEX IECEx
-60ºC to +95ºC IP66 M20 x 1.5 INMETRO
78 † Ex ia IIC IP67 (½" NPT
0.7 GOST
T6 or T4 Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
-60ºC to +95ºC (T4)
SJ06

Media #
-20ºC to +95ºC ATEX IECEx
1.0 (S06) -60ºC to +95ºC IP66 M20 x 1.5
Ex ia IIC INMETRO
78 † 1.7 (S09) IP67 (½" NPT
T6 or T4 Ambient GOST
NEMA 4X Option)
1.7 (S12) -60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
S06, S09 & S12

Media #
-20ºC to +95ºC ATEX IECEx
IP66 M20 x 1.5
Ex ia IIC -60ºC to +95ºC INMETRO
3.0 IP67 (½" NPT
78 † T6 or T4 GOST
Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
SPR -60ºC to +95ºC (T4)

For detailed information on certification please see page 10.


† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.

Safety Parameters:Type 58 Safety Parameters:Type 78


Ui = 35V dc, Ii = 600 mA, Pi = 3 W, Ci = 0 μF, Li = 0 mH Ui = 31 V, Ii = 210 mA, Pi = 1.5 W, Ci = 0 μF, Li = 0 mH
Coil Resistance : 135 Ohm ± 5% Coil Resistance : 370 Ohm ± 5%
Minimum Current @ solenoid coil = 80 mA Minimum Current @ solenoid coil = 32 mA
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
14 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP03P Selection Chart

FP03P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NC Wiring Diagrams
34 50 74 SOLENOID
(EExemb)
TYPE ‘M’ RED +
OVERRIDE

WINDING
OPTION 1
2
BLACK -
3

WINDING

SCHEMATIC 2/2 NC
M20 x 1.5P SOLENOID
CASE
CABLE ENTRY
180.1

AC VOLTAGE
155.4

EXTERNAL 77 SOLENOID
EARTH STUD (EExd)
1
124.6

2
CONNECTIONS AREBI-POLAR

3 WINDING
SOLENOID
CASE
1

50.5
MOUNTING POSITIONS RED + BLACK -
2 x Ø5.5 THRO' HOLES 2
37.1

26.2
DC VOLTAGE
3
25

13.8 Plug port 3 for 2/2


14

78 SOLENOID
= =
Normally Closed (EExia)
28 5 function. (Plugs
RED +
38.1 q available as a line
item). BLACK -

FP03P Selection Chart - Ordering Example


FP03P Model Code
M1 Manifold mount - For use with Axis Manifold System Only
M7 Manifold mount stacker - For use with Axis Manifold System Only Connections
02 1⁄8" NPT body ported - Shown above
32 3-way, 2-position
Valve Configuration
NC Normally Closed
V Viton (Standard) (-20ºC to +180ºC) For maximum operating temperatures
see 'T' Rating Limitations for Ex emb, O-ring Material
AL Flurosilicone (-60ºC to +180ºC) Ex d & Ex ia on pages 12, 13 & 14.
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **

74(Ex emb) 77(Ex d) 78(Ex ia)


A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer to 74 (Ex emb) Page 12 - Table 1
Solenoid option 77 (Ex d) Page 13 - Table 2 Voltage
tables. 78 (Ex ia) Page 14 - Table 3
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary Options
manual override (3.0 Watts Ex d Only)
MLT Electrical and manual required to latch - tamperproof
XX Power (W) 74 (Ex emb)- 1.8 & 3.6 Watts Page 12 - Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP03P 02 32 NC V 77 A 24D ML 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
15
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
FP06P Selection Chart

FP06P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NU
34 50

TYPE ‘M’ NU Normally


OVERRIDE
OPTION
1
Universal offered
2 as standard.
3

SCHEMATIC 2/2 NC
M20 x 1.5P Valve suitable for
CABLE ENTRY
Universal operation
2/2 & 3/2.
191

1
166.5

EXTERNAL 2 Normally Open and


EARTH STUD
Normally Closed.
135.6

3
Plug port 3 for 2/2
1
Normally Closed
SCHEMATIC 2/2 NO function. (Plugs
MOUNTING POSITIONS
61.5

2 x Ø5.5 THRO' HOLES 2 available as a line


46.5

3
item).
33.5

33.5
22

17.5

Plug port 1 for 2/2


= =
1 Normally Open
2
25.4 32 6.2
function. (Plugs
3
44.45
available as a line
item).

FP06P Selection Chart - Ordering Example


FP06P Model Code
S1 10 bar maximum valve pressure
Operator
S2 16 bar maximum valve pressure (For AC Coils = 6.5 Watts)
04 ¼" NPT body ported Connections
32 3-way, 2-position
NU Normally Universal Valve Configuration
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC)
see 'T' Rating Limitations for Ex emb O-ring Material
AG Silicone (-60ºC to +180ºC)
& Ex d on pages 12 & 13.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
Solenoid *
77 (Ex d) Page 13 - Table 2 **
74(Ex emb) 77(Ex d)
A ATEX/IECEx Dual Certified/Labelled  
G GOST x  Solenoid Approval
I INMETRO x 
N NEPSI* x 
U CSA (US) ATEX Dual Certified/Labelled x 
XXX Voltage, refer
74 (Ex emb) Page 12 - Table 1
to Solenoid Voltage
77 (Ex d) Page 13 - Table 2
option tables.
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof
LE Latched Energised (NO/NC Only) (6.5 Watts Ex d Only)
XX Power (W) 74 (Ex emb) - 3.6, 4.4 & 6.8 Watts Page 12 - Table 1
Power
77 (Ex d) - 3.5 & 5.7 Watts Page 13 - Table 2
K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP06P S2 04 32 NU V 77 A 24D ML 35 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12 or 13.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
16 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP06P Selection Chart

FP06P
Dimensional Drawing

FULLY ROTATIONAL SOLENOID HOUSING 72.5 50


M20 x 1.5p CONDUIT ENTRY STD.
1/2” NPT OPTION (K85)

SCHEMATIC 3/2 NU

NU Normally
Universal offered

187.5
1
2 as standard.
3
MOUNTING HOLES Ø5,5 THRO'
PORT 1
PORT 2
46.5

PORT 3
33.5

33.5
17.5
22

16 25.4
32

FP06P Selection Chart - Ordering Example


FP06P Model Code
S1 10 bar maximum valve pressure Operator
04 ¼" NPT body ported Connections
32 3-way, 2-position
NU Normally Universal Valve Configuration
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC)
see 'T' Rating Limitations for Ex ia on O-ring Material
AG Silicone (-60ºC to +180ºC)
page 14.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 58 (Ex ia) Page 14 - Table 3 Solenoid

58(Ex ia)
A ATEX/IECEx Dual Certified/Labelled
G GOST

I INMETRO
 Solenoid Approval

N NEPSI x
U CSA (US) ATEX Dual Certified/Labelled x
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary Options

XX Resistance (Ω) 135 Ohms - 58 (Ex ia) Page 14 - Table 3 Resistance


K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP06P S1 04 32 NU V 58 A M 135 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on page 14.
The solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
17
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
FP10P Selection Chart

FP10P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5
34 50
NU Normally
TYPE ‘M’
OVERRIDE
Universal offered
OPTION 1 as standard.
2
3

SCHEMATIC 2/2 NC
Valve suitable for
M20 x 1.05P Universal operation
CABLE ENTRY
2/2 & 3/2.
Normally Open and
191

1
2
166.5

EXTERNAL Normally Closed.


EARTH STUD
3 Plug port 3 for 2/2
135.6

Normally Closed
1 SCHEMATIC 2/2 NO function. (Plugs
2 available as a line
MOUNTING POSITIONS
61.5

2 x M6 x 9.5 DP item).
47.8
46.5

3
Plug port 1 for 2/2
35.9
20.8

17.8

1 Normally Open
2 function. (Plugs
= =

44.45 q
3 available as a line
Body Ported Shown item).

FP10P Selection Chart - Ordering Example


FP10P Model Code
S1 10 bar maximum valve pressure
S2 16 bar maximum valve pressure (For AC Coils = 6.5 Watts) Operator
S3 35 bar maximum valve pressure - ¼" only standard temperature (Typically 0.4 CV)
04 ¼" NPT body ported
06 3⁄8" NPT port blocks Connections
08 ½" NPT port blocks
32 3-way, 2-position
Valve Configuration
NU Normally Universal
S Nitrile (-20ºC to +130ºC) For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC) see 'T' Rating Limitations for Ex emb
AG Silicone (-60ºC to +180ºC) O-ring Material
AL Fluorosilicone (-60ºC to +180ºC) & Ex d on pages 12 & 13.
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
Solenoid *
77 (Ex d) Page 13 - Table 2 **
74(Ex emb) 77(Ex d)
A ATEX/IECEx Dual Certified/Labelled  
G GOST x  Solenoid Approval
I INMETRO x 
N NEPSI* x 
U CSA (US) ATEX Dual Certified/Labelled x 
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid Voltage
option tables. 77 (Ex d) Page 13 - Table 2
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof
LE Latched Energised (NO/NC Only) (6.5 Watts Ex d Only)
XX Power (W) 74 (Ex emb) - 3.6 & 4.4 & 6.8 Watts Page 12 - Table 1
Power
77 (Ex d) - 3.5 & 5.7 Watts Page 13 -Table 2
K6 BSPP Ports Option
K85 ½" NPT conduit entry Option

FP10P S2 08 32 NU V 77 A 24D ML 35 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
18 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP12P Selection Chart

FP12P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5

34 50

TYPE ‘M’ NU Normally


OVERRIDE
OPTION Universal offered
1
2 as standard.
3

SCHEMATIC 2/2 NC
M20 x 1.5P
CONDUIT ENTRY Valve suitable for
universal operation
EXTERNAL
2/2 & 3/2.
225.5

EARTH STUD
1 Normally Open and
200.8

2
MOUNTING POSITIONS
Normally Closed.
170

2 x M6 x 10 DP
3
Plug port 3 for 2/2
1 Normally Closed
SCHEMATIC 2/2 NO function. (Plugs

96
2
available as a line

67
61

3
item).
43.8
26.5

19.5
Plug port 1 for 2/2
1 Normally Open
27.8 8.5
2 function. (Plugs
44.45 q 3 available as a line
102.8
item).

FP12P Selection Chart - Ordering Example


FP12P Model Code
S1 10 bar maximum valve pressure - standard Operator
08 ½" NPT port blocks Connections
32 3-way, 2-position
Valve Configuration
NU Normally Universal
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (standard) (-20ºC to +180ºC) O-ring Material
see 'T' Rating Limitations for Ex d
AG Silicone (-60ºC to +180ºC)
on page 13.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 77 (Ex d) Page 13 - Table 2 Solenoid *
77(Ex d)
A ATEX/IECEx Dual Certified/Labelled 
G GOST  Solenoid Approval
I INMETRO 
N NEPSI* 
U CSA (US) ATEX Dual Certified/Labelled 
XXX Voltage, refer
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables

M Electrical to switch or temporary manual override


ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof

120 12 Watts - auto reset


65 6.5 Watts - manual reset only (ML) Power

K6 BSPP ports Option


K85 ½" NPT conduit entry Option

FP12P S1 08 32 NU V 77 A 24D ML 65 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on page 13.
* For China (NEPSI), please note that the solenoid operator is Type 87.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
19
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
SJ06 Selection Chart

SJ06
Dimensional Drawing
68 86.5
SCHEMATIC 3/2 NC
34 50

TYPE ‘M’ T
OVERRIDE
OPTION

3
2

M20 x 1.5P 1
CABLE ENTRY EXTERNAL
EARTH STUD
19
221.3

MOUNTING POSITIONS
2 x Ø5.5 THRO' HOLES
196.6

SCHEMATIC 3/2 NO
165.8

=
28
=

T
VIEW OF DETAIL 'A'
1/8" NPT 31.4
PILOT VENT
DETAIL A
59.5

1 2 3
3
2
15
38.1 31.4
48 1
93.5

SJ06 Selection Chart - Ordering Example


SJ06 ¼" NPT
ASJ06 ¼" NPT Low Temperature Model Code

E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
32 3-way, 2-position
NC Normally closed Valve Configuration
NO Normally open
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13- Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **

74(Ex emb) 77(Ex d) 78(Ex ia)


A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables 78 (Ex ia) Page 14 - Table 3
XX Power (W) 74 (Ex emb) -1.8 & 3.6 Watts Page 12- Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13- Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP Ports Option
K85 ½" NPT conduit entry Option

SJ06 E1 32 NC 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
20 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
S06,S09 & S12 Selection Chart

S06, S09 & S12


Dimensional Drawing
SCHEMATIC 3/2 NC

68 86.5

50
T
34

TYPE ‘M’
OVERRIDE
OPTION

3
2

M20 x 1.5P EXTERNAL


CABLE ENTRY EARTH STUD
36.4
212.5

MOUNTING POSITIONS
3 x Ø5.2 THRO' HOLES SCHEMATIC 3/2 NO
187.9
157.1

=
38

T
=

VIEW OF DETAIL 'A'


1/8" NPT
PILOT VENT 20.7
50.8

52.2

DETAIL A 1 2 3
3
36.3 2
50.8 52.2
67.4
125.3 1

S06/S09/S12 Selection Chart - Ordering Example


S06 ¼" NPT
S09 3⁄8" NPT Model Code
S12 ½" NPT
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
22 2 - way, 2 - position
52 5 - way, 2 - position Valve Configuration
32 3 - way, 2 - position
NC Normally Closed NO Normally Open Valve Configuration
XX 52 Valves Only
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
74(Ex emb) 77(Ex d) 78(Ex ia)
A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables.
XX Power (W) 74 (Ex emb) - 1.8 & 3.6 Watts Page 12 - Table 1 Power
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP ports Option
K85 ½" NPT conduit entry Option

S06 E1 32 NC 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
21
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
SPR Selection Chart

SPR
Dimensional Drawing

86.5 180

50 155.4

124.6
SCHEMATIC 3/2 NU
TYPE ‘M’
OVERRIDE
OPTION

EXTERNAL
M20 x 1.5P
162.2

CABLE ENTRY EARTH STUD


MOUNTING POSITIONS
3
128.2

2 x M5 x 9 DP

VIEW OF DETAIL 'A' 2 3


2

84.7
77.7

1
61.2
1
44.7

37.7

= =
24
38.1 96.5
DETAIL A

SPR Selection Chart - Ordering Example


SPR 12 ½" NPT
SPR 19 ¾" NPT - (External Pilot Only)
SPR 25 1" NPT - (External Pilot Only)
ASPR 12 ½" NPT - Low Temperature Service Model Code
ASPR 19 ¾" NPT - Low Temperature Service (External Pilot Only)
ASPR 25 1" NPT - Low Temperature Service (External Pilot Only)
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
32 3 - way, 2 - position Valve Configuration
52 5 - way, 2 - position
NU Normally Universal Valve Configuration
XX 52 Valves Only
00 Spring return end cap Secondary Actuator
EI Internal Pilot
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
74(Ex emb) 77(Ex d) 78(Ex ia)
A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables.
XX Power (W) 74 (Ex emb) - 1.8 & 3.6 Watts Page 12 - Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP ports Option
K85 ½" NPT conduit entry Option

SPR E1 32 NU 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
22 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Accessory Information

Options
Product Options

The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.

Type M - Electrical to Switch or Temporary Type MOR - Electrical to Switch or Temporary


Manual Override Manual Rotary Override

Manual Override Type M Manual Rotary Override Type MOR


The solenoid valve switches on and off with the electrical
The solenoid valve switches on and off with the electrical
supply. The manual override button can be pressed to
supply. The manual override rotary operator can be
operate the valve when the solenoid is in the electrically
turned to operate the valve when the solenoid is in the
de-energised position. The manual override is
electrically de-energised position. The manual override is
non-detented, i.e. does not latch in position. When the
detented, i.e. does latch in position.
button is released, the valve spring returns.

Type ML - Electrical and Manual Required to Switch


or Temporary Manual Override
Type MLT - As above - Tamperproof Type LE - Latched Energised

Manual Reset Type ML & MLT Latch Energised Type LE


For Types ML and MLT, apply the electrical signal and press
Designed specifically for Deluge systems. The solenoid
the reset button. With type ML, the valve moves to the
valve can be used in the electrically de-energised
energised position and will not de-energise until the
condition. When an electrical signal is applied to the valve,
electrical supply is removed. The manual reset button also
the valve shifts to the energised position and stays in this
acts as a manual override, when the valve is in the
position, even if the electrical signal is removed, and until
de-energised position and the electrical supply is off. The
the valve is manually moved back to the de-energised
manual reset is non-detented, spring return, i.e. does not
position by pressing the reset button. The valve can only
latch in position. With type MLT, the valve cannot be
be manually reset after the electrical signal is removed.
moved to the energised position by pressing the button if
The reset button is fitted at the base of the valve.
there is no electrical supply to the solenoid.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
23
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Accessory Information

Options
Product Options for Type 58

The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.

Type M / ML - Electrical to Switch or Temporary Auto Reset Electrical to Switch


Manual Reset (Slimline 58 - Series) (Slimline 58 - Series)

Manual Override Type M & Manual Reset Type ML

The solenoid valve switches on and off with the electrical supply. The manual override button can be pressed to operate the
valve when the solenoid is in the electrically de-energised position. The manual override is non-detented, i.e. does not latch
in position. When the button is released, the valve spring returns.

For Type ML, apply the electrical signal and press the reset button. The valve moves to the energised position and will not
de-energise until the electrical supply is removed. The manual reset button also acts as a manual override, when the valve is
in the de-energised position and the electrical supply is off. The manual reset is non-detented, spring return, i.e. does not latch
in position.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
24 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Models FP06P, FP12P, SJ06, S06, S09, S12 & SPR

Solenoid Valves

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
25
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Installation Workover Control System (IWOCS)

HPU & Wellhead

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
26 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Installation Workover Control System (IWOCS)

HPU & Wellhead

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
27
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Instrumentation Ball and Needle Valves

Selection Table

INSTRUMENTATION PRODUCTS - NEEDLE VALVES (Up to and including 10,000 psi / 690 bar)
Schematic Page
Product Product Code Product Description
Representation Number
¼”NPT, Single Isolate, Needle configuration,
NV0104F02M5V6K
6,000 psi / 414 bar
8”NPT, Single Isolate, Needle configuration,
3
NV0106F02M5V6K
6,000 psi / 414 bar
½”NPT, Single Isolate, Needle configuration,
NV0108F02M5V6K
10 6,000 psi / 414 bar
¼”NPT, Single Isolate, Needle configuration,
NV0104F02M5V10K
10,000 psi / 690 bar
8”NPT, Single Isolate, Needle configuration,
3

NV01 NV0106F02M5V10K
10,000 psi / 690 bar
Single Isolate
½”NPT, Single Isolate, Needle configuration,
NV0108F02M5V10K
10,000 psi / 690 bar
¼”NPT,Block & Bleed Manifold,Needle -
NV0304F02M5V6K
CaptiveVent Plug configuration,6,000 psi / 414 bar
½”NPT,Block & Bleed Manifold,Needle -
NV0308F02M5V6K
CaptiveVent Plug configuration,6,000 psi / 414 bar
11
¼”NPT,Block & Bleed Manifold,Needle -
NV0304F02M5V10K
CaptiveVent Plug configuration,10,000 psi / 690 bar
NV03
Block & Bleed ½”NPT,Block & Bleed Manifold,Needle -
Manifold NV0308F02M5V10K
CaptiveVent Plug configuration,10,000 psi / 690 bar
¼”NPT, Block & Bleed Manifold, Needle -
NV0404F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
½”NPT, Block & Bleed Manifold, Needle -
NV0408F04F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
12
¼”NPT, Block & Bleed Manifold, Needle -
NV0404F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
NV04 ½”NPT, Block & Bleed Manifold, Needle -
Block & Bleed
NV0408F04F02M5V10K Needle configuration, 10,000 psi / 690 bar,
Manifold
¼” Vent Bleed
THIS PRODUCT DESIGN IS UNIQUE TO BIFOLD AND PATENTED
¼”NPT, DBB Manifold, Needle - Needle -
NV0504F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
½”NPT, DBB Manifold, Needle - Needle -
NV0508F04F02M5V6K Needle configuration, 6,000 psi / 414 bar,
¼” Vent Bleed
13
¼”NPT, DBB Manifold, Needle - Needle -
NV0504F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
NV05
½”NPT, DBB Manifold, Needle - Needle -
Double Block &
Bleed Manifold
NV0508F04F02M5V10K Needle configuration, 10,000 psi / 690 bar,
¼” Vent Bleed
THIS PRODUCT DESIGN IS UNIQUE TO BIFOLD AND PATENTED

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated Quality Assurance
so to ensure accurate and up-to-date information please All Bifold products are manufactured to a most stringent
refer to the product catalogue issue list on our web site or QA programme. Every care is taken at all stages of
contact a member of our sales team. is a member of the
4
manufacture to ensure that every product will give optimum
www.bifold.co.uk When selecting a product, the applicable operating system
performance and reliability. We are third party certified to
EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing
function, material compatibility, adequate ratings, correct total traceability are available on request, to BSEN 10204.3.1.B
installation, operation, and maintenance are the where available. We reserve the right to make changes of companies
responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
BFD01/5 August '10 C Bifold 2010
Instrument, Process,
Directional Control Valves,
and Pumps

Pneumatic and
Instrumentation Valves
Hydraulic Valves
Subsea Valves
Hydraulic Pumps,
Intensifiers and Valves

Quality Assurance
All Bifold products are manufactured to a most stringent
Accuracy of Information QA programme. Every care is taken at all stages of
We take care to ensure that product information in this manufacture to ensure that every product will give When selecting a product, the applicable operating
catalogue is reasonably accurate and up-to-date. However, optimum performance and reliability. We are third system design must be considered to ensure safe use.
our products are continually developed and updated so to party certified to BS EN ISO 9001:2008. Functional test The products function, material compatibility, adequate
ensure accurate and up-to-date information please refer to certificate, letter of conformity and copies of original mill ratings, correct installation, operation, and maintenance
the product catalogue issue list on our web site or contact certificates, providing total traceability are available on are the responsibilities of the system designer and user.
a member of our sales team. request to BS EN 10204 3.1 where available. We reserve
the right to make changes to the specifications and
design etc., without prior notice.

UK Office USA Office Singapore Office


Bifold Fluidpower Ltd Marshalsea Hydraulics Limited Bifold Fluidpower Ltd Bifold Fluidpower Ltd
Bifold, Bifold Fluidpower, Bifold Subsea Greenside Way, Marshalsea House,Venture Way 11490 Westheimer, Toa Payoh Industrial Park,
and Marshalsea Hydraulics Ltd Middleton, Manchester, Priorswood Industrial Estate Suite 850, Lorong 8 #07-1475,
are all members of the Bifold Group.
M24 ISW. UK. Taunton, Somerset,TA2 8DE. UK. Houston,TX, 77077. Singapore, 3109075.
Registered No. 1787729 in England.
Registered Office: Greenside Way, Tel: +44 (0) 161 345 4777 Tel: +44 (0) 1823 331081 Tel: +1 (713) 783 4253 Tel: +65 6735 1323
Middleton, Manchester, M24 ISW. Fax: +44 (0) 161 345 4780 Fax: +44 (0) 1823 323382 Fax: +1 (713) 783 0067 Fax: +65 6735 1367
Email: marketing@bifold.co.uk Email: info@marshalsea.co.uk Email: marketing@bifold.co.uk Email: marketing@bifold.co.uk
Web: www.bifold.co.uk Web: www.bifold.co.uk Web: www.bifold.co.uk Web: www.bifold.co.uk

Innovative and Reliable


www.bifold.co.uk
Valve Solutions
BFD15/2 December ‘12 © Bifold 2012
OLIVER
BALL VALVE
ITEM1: BV1, BV2, BV3, BV4, BV5, BV6, BV7, MBV4, MBV5, MBV7, MBV8

CHECK VALVE
ITEM2: CV1, CV2, MCV1, MCV3

NEEDLE VALVE
ITEM3: NV2, MNV2, MNV3

DBB VALVE
ITEM4: DBB
Product Data Sheet LP Type Ball Valve

These high performance quality ball valves are


stocked in 316 stainless steel. Even the pressed
handle on the valve is 304 stainless steel to avoid
rusting on site.

Offered in pressure ranges 1000 PSI to 3000 PSI and


sizes from 9mm to 19mm diameter bores these valves
are recommended for use in oil, gas and
petrochemical applications where reliable long-term
performance is essential.

Threaded connections are NPT, Handle Locking


Standard, NACE Standard, Firesafe Standard (on
3000 PSI version)

Key Features of the Oliver Ball Valve range


• Enclosed soft seats giving positive sealing and low torque operation across the pressure range
• One-piece spindle with anti-blowout shoulder that maintains seal integrity at all pressures
• Precision machined ball for smooth operation through 90 degrees to give straight through bore
• 316 stainless steel one-piece handle fitted with twin anti-vibration locknuts

Standard Specification
Pressure: 1000psi Seals: PTFE Seats: PTFE/PVDF
Temp: 120 deg C (PTFE/PVDF) Thread form: NPT Handle: Lever

Ordering Code
(Typical example) → LPB1F 50 S
Type
LPB – low pressure ball valve
1 – 1000PSI
3 – 3000PSI
F - female

Size (bore sizes available)

25 - 1/4"
38 - 3/8”
50 - 1/2"
75 - 3/4”
10 - 1”

Material

S - 316S31 Stainless Steel

Oliver Valves Ltd, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX. United Kingdom.
T: +44 (0)1565 632636 E: sales@valves.co.uk. W: www.valves.co.uk
© Oliver Valves Ltd 2010
Oliver Valves Limited, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX, England
Telephone: 01565 632636 Fax: 01565 654089 Email: sales@valves.co.uk www.valves.co.uk

Product Data Sheet B10F Type Ball Valve

The ‘B10’ Type Single Isolating Ball Valve is designed


for safe and reliable isolation giving bubble tight shut
off. Totally enclosed soft seats offer both positive
sealing and low operating torques, from vacuum to
high-pressure service. Anti-blow out spindle is fitted as
standard with the option of PTFE or Grafoil seals.

Part No. Connections A B C Weight


Size (Kgs)
B10FX25 1/4" 2.4 1.3 2.5 0.4
B10FX38 3/8” 2.4 1.3 2.5 0.4
B10FX50 1/2" 2.4 1.3 2.5 0.5

Key Features of the Oliver Ball Valve range


• Totally enclosed soft seats giving positive sealing and low torque operation across the pressure
range
• One-piece spindle with anti-blowout shoulder that maintains seal integrity at all pressures
• Precision machined ball for smooth operation through 90 degrees to give straight through bore
• Either PTFE or Grafoil spindle and body seals to give high body integrity
• 316 stainless steel one-piece handle fitted with twin anti-vibration locknuts

Standard Specification
Pressure: 10,000psi Seals: PTFE Seats: PTFE/KEL-F
Temp: 200 deg C Thread form: NPT Handle: Lever

Ordering Code
(Typical example) → B10FX 50 S / BT / FS
Type
B10 = Ball valve 10,000 psi
F = Female x Female
X = 10mm bore

Size (10mm bore size only)

25 - 1/4"
38 - 3/8”
50 - 1/2”

Material

S - 316S31 Stainless Steel


M - Monel (400)
HC - Hastalloy C276
(Others available)

Optional Connections (NPT Standard)

BT - BSP Taper
BP - BSP Parallel (top sealing)
SW - Socket Weld

Options

FS - Firesafe to BS6755 Pt2/API 607 Rev4 OH - Oval Handle


(Firesafe approval to 6000 psi only) PE - Pinned End Connectors (prevents accidental removal)
HL - Handle Locking PMHB - 4 x M5 mounting holes in base for panel mounting
NA - NACE MR-01-75 (latest revision) PMHT - 4 x M5 mounting holes in top for panel mounting

Copyright  2005 Oliver Valves Ltd. All rights reserved. E&OE. Rev. 1.0
Product Data Sheet Check Valve
Key features

• In-line poppet type


• Allows flow in one direction only,
closing when flow reverses
• Max temperature 200°C
• VITON seats (VITON 90 available
for NACE, KALREZ also available
if required
• NPT female X female connections

General Arrangement Drawing

Sizes Part No Max Pressure Cracking Pressure A B Weight CV (Max)

¼” CV25S 6,000 PSI 7 PSI 0.87” 2.31” 0.2kg 0.7


⅜” CV38S 6,000 PSI 7 PSI 1.10” 2.50” 0.3kg 0.7
½” CV50S 6,000 PSI 7 PSI 1.10” 3.06” 0.3kg 2.0
¾” CV75S 6,000 PSI 4 PSI 1.63” 3.63” 0.8kg 4.6
1” CV10S 6,000 PSI 4 PSI 2.05” 4.19” 0.9kg 7.2

Rev 1.1

Oliver Valves Ltd, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX. United Kingdom.
T: +44 (0)1565 632636 E: sales@valves.co.uk. W: www.valves.co.uk
© Oliver Valves Ltd 2009
Oliver Valves Limited, Parkgate Industrial Estate, Knutsford, Cheshire, WA16 8DX, England
Telephone: 01565 632636 Fax: 01565 654089 Email: sales@valves.co.uk www.valves.co.uk

Product Data Sheet F Type Needle Valve

The ‘F’ Type Single Isolating Needle Valve is designed


for safe and reliable isolation giving bubble tight shut off,
non-rotating & anti-galling tip and dynamic self-adjusting
spindle seal to give long service life in a variety of
applications.

Part No. Connections A B C Weight


Size (Kgs)
F25 1/4" 3.6 2.1 1.1 0.5
F38 3/8” 3.6 2.4 1.1 0.5
F50 1/2" 3.6 2.6 1.1 0.5
F75 3/4" 3.6 2.9 1.5 0.8
F10 1” 3.6 3.2 2.0 1.4

Key Features of the Oliver Needle Valve range


• Non rotating tip - self centering & anti-galling
• Piston ring - gives dynamic adjustment of gland seal in response to pressure change
• Anti-blow out spindle - a major safety feature
• Secure seal - precision machined to give leak free operation for the life of the valve. Available
in either PTFE or Grafoil

Standard Specification
Pressure: 6000psi Packing: PTFE Handle: T-Bar Bore: 0.21” (5.4mm)
Temp: 240 deg C Thread form: NPT Seat: Metal to metal CV: 0.46

Ordering Code
(Typical example) → F 50 S / BT / AT
Type
Female x Female

Size

25 - 1/4" 75 - 3/4"
38 - 3/8” 10 - 1”
50 - 1/2"

Material

S - 316S31 Stainless Steel


C - 230M07 Carbon Steel
M - Monel (400)
HC - Hastalloy (C276)
(Others available)

Optional Connections (NPT Standard)

BT - BSP Taper
BP - BSP Parallel (top sealing)
SW - Socket Weld

Options

AG - Grafoil LT200 - Cryogenic Head Unit (-200°C)


AT - Anti-Tamper MT - Metering Tip
HL - Handle Locking MTG - Mounting Holes x 2
HL PI - Handle Locking + Position Indicator NA - NACE MR-01-75 (latest revision)
HP - 10000 psi OXY - Oxygen Cleaned
HW - Hand Wheel PK - PEEK Soft Tip (not available oxygen cleaned)
LT100 - Cryogenic Head Unit (-100°C) PM - Panel Mount

Copyright  2005 Oliver Valves Ltd. All rights reserved. E&OE. Rev. 1.0
BIS
RELIEF VALVE
ITEM1: PSV‐2880A, PSV‐2880B, PSV‐2880AB, PSV‐2880C, PSV‐2880D,
PSV‐2880CD
RELIEF VALVE (H.P.) TYPES: RL25, RL37
PRESSURE EQUIPMENT DIRECTIVE (PED) 97/23/EC APPROVED.
STAINLESS STEEL (316 / 1.4404) Valves Ltd
SUITABLE FOR LIQUID USE.
ALL DIMENSIONS IN INCHES.

Leaktight when 90% of "set pressure" is applied. Ø2.50 Handwheel

Repeatability ±5% of "set pressure".

Re-seating within 20% of "cracking pressure".


(Pre-set cracking pressure is optional)
State details when ordering.

Recommended MAXIMUM back


pressure 1,000 psi. (70 Bar).

Mounting details for the RL25-E only.

3.80 (5.30" with Handwheel)


Hole panel dia: Ø0.75"
Panel thickness: 0.125" to 0.250"

OUTLET

Circuit Symbol
1.35

Handwheel (external) Adjustment


assembly. (Optional extra)
Ordering Code: E

INLET

1.48
(Across Flats)

ORDERING
TECHNICAL SPECIFICATION EXAMPLE
Valve Type: RL25 RL37 RL25

Porting / Connection Options: P = BSP (Parallel) N = NPT (Taper)


("AE" threads fitted only to the INLET port)
N
44AE (1/4" O.D. Tube) 56AE (3/8" O.D. Tube) 81AE (9/16" O.D. Tube)
Autoclave Outlet Port Options: 25N (1/4" NPT) 37N (3/8" NPT)
Valve Options: E = Handwheel (external) Adjustment
Working Media: (std) Oil / Water Glycol Duty (no ordering code req'd)
Working Media: (options) WD = Water Duty SWD = Sea Water Duty
Press. Range: 0.4K - 1.6K psi, 1K - 4K psi, 3K - 9K psi, 8K - 15K psi Max W.P. 9K
Orifice Size: Ø0.125"
Port Size: 1/4" 3/8"
Valve Seat Mat'l: (standard) Stainless Steel - 440C (liquid use)
Valve Seat Mat'l: (options) 1.4542 St.Steel - Water Duty Inconel - Sea Water Duty
Seal Material: Viton (other materials available by request)
Dry Weight: (kg) 1.2 1.2
Working Temperature Range: -10°C to +120°C
Flow Rate: Contact factory for details
Technical Specification Notes:-
* Other materials available (Monel, Inconel, Hastelloy) subject to PED approval.

C.1102.00.0005 09/07 Page 7 : 7


RELIEF VALVE (H.P.) TYPE: RL50
PRESSURE EQUIPMENT DIRECTIVE (PED) 97/23/EC APPROVED.
STAINLESS STEEL (316 / 1.4404) Valves Ltd
SUITABLE FOR LIQUID USE.
ALL DIMENSIONS IN INCHES Ø2.50" Handwheel with
Locking Nut
(Optional extra)
Ordering Code: "E"
Leaktight when 90% of "set pressure" is applied.

Repeatability ±5% of "set pressure".

Re-seating within 20% of "cracking pressure".


(Pre-set cracking pressure is optional)
State details when ordering.

Recommended MAXIMUM back


4off Fixing Holes

6.70 Adjustable
pressure 1,000 psi. (70 Bar).
(threaded) for M6 bolts 1.54"
SQ. Fixing Centres
(Ø1.80" recommended
Locking Screw and Washer clearance hole for panel
(can be removed when mounting)

5.45
mounting valve to a panel)

(2.50" for 81AE option)


OUTLET

2.00
Circuit Symbol

1.20
INLET

2.00 SQ. Body

ORDERING
TECHNICAL SPECIFICATION EXAMPLE
Valve Type: RL50 RL50

Porting / Connection Options: P = BSP (Parallel) N = NPT (Taper)


("AE" threads fitted only to the INLET port)
N
56AE (3/8" O.D. Tube) 81AE (9/16" O.D. Tube)
Autoclave Outlet Port Options: 50N (1/2" NPT)
Valve Options: E = Handwheel (external) Adjustment
Working Media: (standard) Oil / Water Glycol Duty (no ordering code req'd)
Working Media: (options) WD = Water Duty SWD = Sea Water Duty
Press. Range: 200 - 1.6K psi, 1 - 5K psi 4K - 15K psi Max W.P. 5K
Orifice Size: Ø6.0mm Ø4.1mm
Port Size: 1/2"
Valve Seat Mat'l: (standard) Stainless Steel - 440C (liquid use)
Valve Seat Mat'l: (options) 1.4542 St.Steel - Water Duty Inconel - Sea Water Duty
Seal Material: Viton (other materials available by request)
Dry Weight: (kg) 1.75
Working Temperature Range: -10°C to +120°C
Flow Rate: Contact factory for details

Technical Specification Notes:-


* Other materials available (Monel, Inconel, Hastelloy) subject to PED approval.

C.1104.00.0012 09/07 Page 7 : 11


BIFOLD MARSHALSEA
MOTOR DRIVEN PISTON PUMP
ITEM1: PBE‐2880A, PBE‐2880B, PBE‐2880C, PBE‐2880D
Type SW water pump . . . Marshalsea Hydraulics Page 1 of 1

Type SW hydraulic pump for water

Small – low power requirement


Specifically designed for water applications
Rotating swash plate design – 2 or 3 pistons
HOME
Pressure up to 690 bar
PUMPS, MOTOR PUMP 316 stainless steel
UNITS
Vertical or horizontal mounting
Water/Glycol pumps
Water pumps
Oil pumps
PRESSURE INTENSIFIERS
Topside use The SW high pressure pump is designed princi璸ally for Applications
Subsea applications operation with water and water-based fluids where limited Ideal for the charging of accumulators on unmanned
DOWN HOLE POWER PACK power is available, but the re璹uire ment is for pressure platforms or for use in remote and inaccessible locations.
VALVES up to 690bars. This pump can be powered by a 0.5 to 0.75 The SW pump is manufactured from 316 stainless steel to
Relief valves Kw 24v DC motor where only wind or battery power or withstand hostile environments.
Thermal relief backup is available. Pump characteristics options
Directional valves Installation Theoretical
Slide valves Rotation is bi-directional and the pump may be mounted No. of pistons flow Max pressure
Shutdown, lockout relay, horizontally or vertically. If vertical mounting is selected, Pump No. and size (ins) (cc/rev) (bar)
excess flow, flowline pilot our Technical Department should be consulted. A suction 11440–21 2 x 0.250 0.43 850
GENERAL filter of at least 60 microns should be used, and care 11440–41 3 x 0.250 0.65 850
About us should be taken to ensure that the filter is of adequate size
11440–42 3 x 0.313 1.00 850
Quality and does not cause more than 300 mm Hg depression.
Contact 11440–43 3 x 0.375 1.45 690
11440–44 3 x 0.437 2.00 690

WATER PUMPS
The picture indicates the
Type TW
small size of a typical motor
Type SW
pump unit based on the SW
pump. One assembly offers
1.5 lpm at 207 bars with 1,500
rpm. The other offers 0.3 lpm
at 690 bars with 500 rpm.
Pipes should be of sufficient size to give not more than Both assemblies are driven by
3.70 m/sec velocity in the delivery line and 1.20 m/sec in a 0.75 Kw 24v DC powered
the suction line. The suction line should be kept under flameproof rated motor.
positive pressure when the pump is stationary to allow
priming.
We recommend that the fluid reservoir should be between Material and weight
50 mm and 3 m above the suction port. 316 stainless steel, 19Kg

Drawing
Dimensions in mm

© Marshalsea Hydraulics Limited – a member of the Bifold Fluidpower group of companies.


Website by Big Bird Design

http://www.marshalsea.co.uk/typesw.html 03/04/2013
Type XW water glycol pump . . . Marshalsea Hydraulics Page 1 of 2

Type XW water glycol pump/motor pump unit

Rotating swash plate design – 3 or 6 pistons


Flow/pressure combinations within 15 Kw range
– up to 41 l/m or up to 870 bar continuous
HOME Casing all 316 stainless steel
PUMPS, MOTOR PUMP Duplex operation option
UNITS Vertical or horizontal mounting
Water/Glycol pumps
Water pumps
Oil pumps
PRESSURE INTENSIFIERS
Topside use The high pressure Type XW hydraulic Pump characteristics options
Subsea applications pump is suitable for a wide range of fluids Max pressure
including water-based solutions and oil- Piston Theoretical flow Continuous Intermittent
DOWN HOLE POWER PACK
based fluids. Separation of the lubricating Pump No. size (ins) USg/m l/m cc/rev psi bar psi bar
VALVES oil and the pumped fluid is achieved by 1/3 stroke, 3 piston pumps
Relief valves the installation of a cavity between the
Thermal relief 11196–50R1 0.437 0.7 2.8 1.59 12,750 870 14,500 1,000
cylinder block and the case. Bypass from
Directional valves the pistons is collected in this cavity and 11196–51R1 0.500 0.9 3.6 2.08 10,000 700 12.000 825
Slide valves returned to the inlet side of the pump. 11197–50 0.437 0.7 2.8 1.59 7,500 520 9.000 625
Shutdown, lockout relay,
The pump is available with either three or 11197–51 0.500 0.9 3.6 2.08 7,500 520 9.000 625
excess flow, flowline pilot
six pistons. The six piston version can be 11197–52 0.562 1.2 4.6 2.63 7,500 520 9.000 625
GENERAL supplied with duplex deliveries which may
About us 11197–53 0.625 1.5 5.6 3.70 6,000 420 7.000 500
be used for simultaneous high and low
Quality pressure applications when used with an 11197–54 0.687 1.8 6.8 3.93 5,000 345 6.000 414
Contact automatic unloading valve. Additional 2/3 stroke, 3 piston pumps
variations are possible by varying the 11196–60R1 0.437 1.5 5.6 3.20 12,750 870 14,500 1,000
input speed to a maximum of 1,800rpm.
WATER GLYCOL PUMPS 11196–61R1 0.500 1.9 7.3 4.16 10,000 700 12.000 825
Type XW 11197–60 0.437 1.5 5.6 3.20 7,500 520 9.000 625
XW installation and start up
11197–61 0.500 1.9 7.3 4.16 7,500 520 9.000 625
Type XWH
Comparison of pump types 11197–62 0.562 2.4 9.2 5.26 7,500 520 9.000 625
Testimonials 11197–63 0.625 3.0 11.4 6.53 6,000 420 7.000 500
Simplex Duplex
11197–64 0.687 3.6 13.7 7.86 5,000 345 6.000 414
Various combinations of flows and
Full stroke, 3 piston pumps
pressures are possible within the 15 kw
range up to a maximum of 870 bar 11196–40R1 0.437 2.2 8.4 4.80 12,750 870 14,500 1,000
(12,750 psi) at 2.8 litres/min (0.7 USg/m) 11196–41R1 0.500 2.8 10.9 6.25 10,000 700 12.000 825
or up to 41.2 l/m (10.8 USg/m) at 220 bar 11197–40 0.437 2.2 8.4 4.80 7,500 520 9.000 625
– see table on the right.
11197–41 0.500 2.8 10.9 6.25 7,500 520 9.000 625
Installation
11197–42 0.562 3.6 13.8 7.90 7,500 520 9.000 625
See installation and start up page.
11197–43 0.625 4.5 17.1 9.79 6,000 420 7.000 500
Material
All external components manufactured 11197–44 0.687 5.4 20.6 11.79 5,000 345 6.000 414
from 316 stainless steel – pump shaft is Full stroke, 6 piston pumps
medium carbon steel EN9 or EN8M. 11202–40 0.437 4.4 16.8 9.60 7,500 520 9.000 625
Weight 11202–41 0.500 5.6 21.8 12.50 6,000 420 7,000 500
45 Kg
11202–42 0.562 7.2 27.6 15.80 4,800 330
11202–43 0.625 9.0 34.2 19.58 3,750 260
11202–44 0.687 10.8 41.2 23.58 3,200 220
3 x 0.625
11202–45 5.0 19.3 11.00 10,000 700
3 x 0.500
Pressure and flow combinations are at 1,750rpm using a 4-pole motor at 60Hz.

Drawing

http://www.marshalsea.co.uk/typexw.html 03/04/2013
Type XW water glycol pump . . . Marshalsea Hydraulics Page 2 of 2

© Marshalsea Hydraulics Limited – a member of the Bifold Fluidpower group of companies.


Website by Big Bird Design

http://www.marshalsea.co.uk/typexw.html 03/04/2013
COMMERCIAL
MOTOR DRIVEN PUMP
ITEM1: PBE‐2883
LARZEP
MANUAL HAND PUMP
ITEM1: PBE‐2881, PBE‐2882
LARZEP
MANUAL HAND PUMP
ITEM1: DPI‐2882‐1, DPI‐2881‐1, DPI‐2883‐1, DPI‐2884‐1
BULLETIN NO. 120/02
(Supersedes 120/01)

Mid-West
Instrument
®

Model 120 Series “Filter Minder”®


Piston-Type Differential Pressure Gauge
MEDIUM RANGE: 0-5 P.S.I.D. to 0-110 P.S.I.D. (0.35 to 7.0 bar)
A low cost differential pressure gauge for use
in measuring the pressure drop across filters,
strainers, separators, valves, pumps, chillers,
etc., and for local flow indication and control.
• Simple, rugged, compact design.
• Working pressure 6000 P.S.I.G. (400 bar)
models 120-A and 120-S.
• Working pressure 5000 P.S.I.G. (340 bar)
models 120-M and 120-N.
• Over-range protection to max. pressure.
• Aluminum or 316 stainless steel housing
with 316 stainless steel internals.
• Monel or Aluminum Bronze housing with
monel internals.
• Weather-resistant construction standard.
• Accuracy +3-2-3% full scale (ascending).
• Shatter resistant lens.
• More cost effective and more accurate than 2-1/2" Plastic Dial Assy.
using two pressure gauges in monitoring
differential pressure.
• 3-1/2" and 4-1/2" annodized aluminum dial assemblies.
• 2-1/2" and 4-1/2" plastic dial assemblies. • Uni-directional or bi-directional.
• Five Year Limited Warranty

Differential pressure is sensed by the movement of a floating piston


magnet against a calibrated spring. The gauge pointer, outside the
pressure housing, follows the movement of the piston magnet and
indicates differential pressure.
Available with magnetically actuated hermetically sealed CSA listed
reed switches to provide high and low limit alarm or control.

4-1/2" Plastic Dial Assy

An optional maximum indication follower pointer provides automatic


indication of maximum differential occuring during a time period or
system cycle.
Reversed pressure ports are optionally available to facilitate
installation and readability depending on which side of a filter, etc.,
the instrument must be installed. 2-1/2" Plastic Dial Assy. w/Max.
Follower Pointer
Why use a dp gauge like this, instead of one or two
pressure gauges to monitor a filter? Let's take a
typical filter application – 1000 P.S.I.G. system
pressure and 25 P.S.I.G. maximum dp. Two 1%
accuracy pressure gauges (0-2000 P.S.I.G.) could
have a combined error of +40 P.S.I.G. (more than the
maximum allowable dp!) A 0-50 P.S.I.D. Model 120
would have an error of +1 P.S.I. at a reading of 25
P.S.I.D., 40 times the accuracy of more costly
pressure gauges!
NOTE: Due to precision sizing of piston and body
bore, leakage across the piston will not
exceed 15 SCFH air at 100 P.S.I.D. at
ambient conditions.
Cutaway View w/1/4" FNPT Back Connections
®
Model 120 “Filter Minder”
Differential Pressure Gauge with Control Switching
The Model 120 “Filter Minder”® gauge is available with one or two hermetically sealed
reed switches.The switches are adjustable (see table for adjustment range) within a
defined percentage of the full scale range of the gauge and are available in SPDT and
SPST, normally open or normally closed configurations for various load power ratings.
The switches can be set to activate or deactivate on rising or falling pressure.
All hazardous location switches are CSA & UL Listed.The CSA & UL listings are for
the entire design and not just the enclosure. All standard and weatherproof units are
CE marked for conformance with the Low Voltage Directive to harmonized standard
EN 61010-1.
The standard reed switch is enclosed in a weather-resistant plastic housing.
Adjustment of the switch setting is made with an external screw adjustment.
The switch functionality will be different for gauges with bi-directional operation for
Standard Enclosures for two (2) Switches positive and negative delta pressure. For example a SPDT switch with positive ∆P
w/1/4" FNPT Conduit Connection. applied to the gauge, the red wire will be N.O. and the black will be N.C.. For negative
Nema 4X /IP65 ∆P the functionality will be reversed.
Location for a single SPDT (grommet or conduit) switch will be on the bottom of the gauge body for a
normal port and on the top for a reverse port. Locations for a single SPST (grommet or conduit) N.O.
or SPST N.C. switch will be on the bottom and top respectively for a normal port gauge.The locations
will be reversed for a reverse port gauge. For more details request IM 120/latest.
A non-indicating (no dial) differential pressure switch is also available.

Special Switch Enclosures


1 Hazardous Locations Division 1:
CSA & UL listed design with SPST 1 2
or SPDT switches in NEMA 7/9
enclosure approved for use in Class UL ®

1 Division 1, Groups C & D; Class 2, LISTED

Division 1, Groups E, F, & G atomospheres.


2 Hazardous Locations Division 2:
CSA & UL listed design with SPST
or SPDT switches in a general
purpose enclosure approved for use UL
®

in Class 1, Division 2, Groups LISTED


A, B, C, & D; Class 2, Division 2,
Groups F & G atmospheres.
3
3 Weatherproof:
Switch(es) and gauge are
enclosed in a non-corrosive, molded, plastic
enclosure that are oil-tight, dust-tight, and
water-tight per NEMA 4X. Design is CE
marked for conformance to the Low Voltage
Directive.
Reed Switch Ratings
(Resistive Load)
Type SPST SPST SPDT SPDT
Option: B,C,D*** E,F,G H A Red (Normally Open)
*Power 50 W 60 W 60 W 3W
Max. Current 0.5 Amps 3.0 Amps 1.0 Amps 0.25 Amps
Switch
Max. Voltage Shown at White (Common)
240 240 240 125
VAC/VDC Zero
**Setting (%F.S.) 10 to 100 25 to 95 25 to 100 10 to 90 Pressure Black (Normally Closed)
Hysterisis 10% / 2% 15% / 8% 20% / 13% 10% / 5%
(Max/Nom) (F.S.) (F.S.) (F.S.) (F.S.)
Repeatability 1% F.S. 1% F.S. 1% F.S. 1% F.S.
Leads 22 Awg. (2), 24" (2), 24" (3), 24" (3), 24"

*Product of the Switching Voltage & Current shall not exceed power rating of the device.
**Except where otherwise noted.
***B, C, & D options are available, however they are not identified in Electrical
Specifications. (Recommend using E, F, or G)

STANDARD MODEL SPECIFICATIONS


120-AA-00-OO
6000 P.S.I.G. Working Pressure Aluminum Body, Stainless Steel Piston, Ceramic
Magnets, Buna N Seals, 2-1/2" Engineering Plastic Case with Shatter-Resistant Lens.
1/4" FNPT Back Connections. Accuracy +3-2-3% Full Scale (Ascending).

PART NUMBERING SYSTEM


1 2 0 – – – –

➅ OPTIONS (Up to four options)


O. None (Standard)
➀ BASIC MODEL NUMBER A.
B.
Reversed High/Low Process Connections
DIN2353 12-S (12mm) Steel Tube Fittings (2)
C. Mounting Holes in Gauge Body for Field Mounting of Electrical Configurations Options A & B

➁ MATERIAL
A. Aluminum Body, S.S. Piston (Standard)
D.
F.
Mounting Holes in Gauge Body for Field Mounting of Electrical Configurations Options L & M
Pipe Mounting Kit (Carbon Steel) (Not available w/C or D Electrical Switch Options)
L. Liquid Fill (Not available w/follower pointer) (Not available with 3-1/2" dial)
M. Monel Body (See 120 ABM) (5000 P.S.I.G. working pressure)
M. Maximum Indicator Follower Pointer
N. Aluminum Bronze Body (See 120 ABM) (5000 P.S.I.G. working pressure)
T. Oxygen Cleaning
S. 316 S.S. Body & S.S. Piston (Standard)
U. S.S. Tag Mounted w/S.S. Wire
Z. SPECIAL (Uncoded Options)
V. S.S. Tag Mounted w/S.S. Screws

➂ DIAL TYPE
A. 2-1/2” Round Uni-Directional Engrd. Plastic Housing Assy. (Standard)
W.
X.
Wall Mounting Kit
Individual Gauge Packaging
Z. Special (Uncoded Options)
B. 2-1/2” Round Bi-Directional Engrd. Plastic Housing Assy.
C. 4-1/2” Round Uni-Directional Engrd. Plastic Housing Assy.
D. 4-1/2” Round Bi-Directional Engrd. Plastic Housing Assy.
E. 3-1/2” Round Uni-Directional Anod. Aluminum Housing Assy.
F. 3-1/2” Round Bi-Directional Anod. Aluminum Housing Assy.
G. 4-1/2” Round Uni-Directional Anod. Aluminum Housing Assy.

– (Up to three options)


H.
T.
4-1/2” Round Bi-Directional Anod. Aluminum Housing Assy.
Non-Indicating Differential Pressure Switch Only (Select Appropriate Electrical Option) ➆ ELECTRICAL CONFIGURATIONS
(NOTE: All options marked, except E, F, J & K)
Z. Special (Uncoded Options)
O. None
A. One (1) Switch in STD. Enclosure with Grommet Wire Seal
B. Two (2) Switches in STD. Enclosures with Grommet Wire Seal
C. One (1) Switch in STD. Enclosure with 1/4” FNPT Electrical Connection NEMA 4X
➃ SEALS
0. Buna N (Standard)
D.
E.
Two (2) Switches in STD. Enclosures with 1/4” FNPT Electrical Connection NEMA 4X
One (1) Switch in General Purpose Enclosure, C.S.A. & U.L. Listed, Division II Locations (1) (3)
1. Viton® F. Two (2) Switches in General Purpose Enclosure, C.S.A. & U.L. Listed, Division II Locations (1) (3)
2. Neoprene G. One (1) Switch & Gauge in NEMA 4X Plastic Enclosure (Not Available With End Connections)
4. Teflon® H. Two (2) Switches & Gauge in NEMA 4X Plastic Enclosure (Not Available With End Connections)
J. One (1) Switch in Explosion Proof Enclosure with Glass Window Cover and C.S.A. & U.L. Listing (2)
➆➇

5. Ethylene Propylene
6. Perfluoroelastomer K. Two (2) Switches in Explosion Proof Enclosure with Glass Window Cover and C.S.A. & U.L. Listing (2)
9. Special (Uncoded Options) L. One (1) Switch in STD. Enclosure with Plug-In Connector (DIN 43650/IP65-PG11)
*Viton® is a Registered Trademark of DuPont Dow Elastomers. M. Two (2) Switches in STD. Enclosure with Plug-In Connector (DIN 43650/IP65-PG11)
**Teflon® is a Registered Trademark of DuPont. Z. Special (Uncoded Options)

(1)
Complete Assembly Rated Class I, Div. II, Groups A, B, C, & D; Class II, Div. II, Groups F and G.
(2)
Complete Assembly Rated Class I, Div. I, Groups C & D; Class II, Div. I, Groups E, F, & G.
(3)
5000 PSIG Working Pressure.

➄ CONNECTIONS
(NOTE: Models 120M and 120N available only with end connections)
0.
2.
1/4" FNPT Back Connections (Standard)
1/4" FNPT End Connections
➇ ELECTRICAL SPECIFICATIONS (For Resistive Loads)
A. S.P.D.T., 3W, 0.25 Amp., 125 VAC/VDC (Standard) (Switch adjustable range of 10-90%)
6. 7/16" - 20 Str. Thd. O-Ring Port (Back Connections) E. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC (Normally Open) (Switch adjustable range of 25-95%)
7. 1/2" FNPT Stainless Steel Adaptors F. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC (Normally Closed)
8. 1/2" FNPT Monel Adaptors (Switch adjustable range of 25-95%)
9. Special (Uncoded Options) G. S.P.S.T., 60W, 3.0 Amp., 240 VAC/VDC One (1) Normally Open, One (1) Normally Closed (4)
H. S.P.D.T., 60W, 1.0 Amp., 240 VAC/VDC (Switch adjustable range of 25-100%)
Z. Special (Uncoded Options)

(4)
Available with Electrical Configurations B, D, F, H, K and M only.
NOTE: NOT ALL OPTIONS AVAILABLE IN COMBINATION WITH OTHER OPTIONS.
NOTE: FACTORY PRESET SWITCHES AT NO CHARGE (SPECIFY SETTING)
NOTE: THE USE OF DIAPHRAGM SEALS IS NOT RECOMMENDED FOR MODEL 120 SERIES GAUGE.
ATTEMPTS TO INSTALL SUCH SEALS ON THIS GAUGE WILL VOID THE WARRANTY.
MOUNTING INFORMATION & DIMENSIONAL DATA
MODEL 120: 2-1/2" INCH PLASTIC DIAL ASSY.

MODEL 120: 4-1/2" INCH PLASTIC DIAL ASSY.

NOTES: 1. Drawings show standard gauge nominal dimensions. (not to scale)


2. Dimensions shown in parentheses are in millimeters.
3. Mounting dimensions for 3-1/2" & 4-1/2" alum. Dial assys. – Contact Factory

Manufacturer reserves the right to change specifications without prior notice.

PROOF PRESSURE: 12,000 PSI for models 120-A and 120-S.


10,000 PSI for models 120-M and 120-N.
TEMPERATURE LIMITS: -40°F(-40°C) to +200°F(+93°C) - These limits are based on the entire instrument
being saturated to these temperatures. System (process) temperatures may exceed these limitations with
proper installation. Contact our customer service representative for details.
STANDARDS: All Model 120 Series differential pressure gauges either conform to and/or are designed to
the requirements of the following standards:
ASME B1.20.1 NACE MR0175
ASME B40.1 NEMA Std. No. 250
CSA-C22.2 No. 14.25 and 30 SAE J514
EN-61010-1 UL Std. No. 50,508 and 1203

Mid-West
Instrument
®
R E P R E S E N T E D B Y:

6500 Dobry Dr. ■ Sterling Heights, MI 48314 U.S.A.


(586) 254-6500 ■ FAX (586) 254-6509
E-mail: sales@midwestinstrument.com
Website: www.midwestinstrument.com

Printed in U.S.A.
PARKER
SPIN‐ON FILTER
ITEM1: HF1, HF2

HYDRAULIC FILTER
ITEM2: HF3
12AT/50AT Series
Spin-On Filters

1
Spin-On Filters
12AT/50AT Series

Applications for
Spin-On Filters
Mounting Ports
n 6 hole pattern n Both NPT and
n Mobile Equipment
for flexibility SAE straight
n Hydrostatic Drives thread available

n Industrial Power Units


Disposable
n Reservoir Breathers Canister
Indicator Gauge
n No mess, oil is
n Shows at a glance
contained inside
when the canister
Often, economic conditions dictate n Easy to handle
needs changing
n Single and
what type of filter is used on a double lengths
piece of equipment. When costs for longer life
are tight, you need a filter that is
inexpensive, yet uncompromising
in performance and quality. Interchangeability
n Parker canisters
Parker's spin-on filters fit that fit many competitors'
need. They are built to fit heads. Contact
demanding design parameters Hydraulic Filter
in today's mobile and industrial Division for
part numbers
equipment. No compromising.

TYPICAL
RETURN
LOCATIONS

RETURN
SUCTION

BREATHER
OFFLINE

Parker Hannifin Corporation


Hydraulic Filter Division
2 Metamora, OH
Spin-On Filters
12AT/50AT Series

Typical Element Performance: 12AT Typical Element Performance: 50AT


Media Filter Beta Particle Media Filter Beta Particle
Code Media Ratios Size / Efficiency Code Media Ratios Size / Efficiency

25C Cellulose B25=2 25 / 50% 25C Cellulose B25=2 25 / 50%


10C Cellulose B10=2 10 / 50% 10C Cellulose B10=2 10 / 50%
03C Cellulose B3=2 3 / 50% 03C Cellulose B3=2 3 / 50%
20B Microglass B20=75 20 / 98.7% 20B Microglass B20=75 20 / 98.7%
10B Microglass B10=75 10 / 98.7% 10B Microglass B10=75 10 / 98.7%
10C-2 Cellulose B10=2 10 / 50%
20B-2 Microglass B20=75 20 / 98.7%
10B-2 Microglass B10=75 10 / 98.7%
03B-2 Microglass B3=75 3 / 98.7%
Actual results are dependent on system flow rates, Actual results are dependent on system flow rates,
fluid viscosities, and other parameters. fluid viscosities, and other parameters.

Beta Efficiency at (X)


Rating Particle Size
Bx = 2 ................................................................................... 50.0%
Bx = 20 ................................................................................. 95.0%
Bx = 75 ................................................................................. 98.7%
Bx = 200 ............................................................................... 99.5%
Bx = 1000 ........................................................................... 99.99%

20B 25C
.70 12AT ASSEMBLY 03C 10C 25C
.70 50AT-1 ASSEMBLY 03C 10B 10C
10 10

.60 150 SUS .60 150 SUS


(BAR)

(BAR)

8 8

.50 .50
PRESSURE DROP

PRESSURE DROP

.40 6 .40 6

.30 .30
4 4

.20 .20
(PSI)

(PSI)

2 2

.10 .10

0 0
.0 0 2 4 6 8 10 12 14 16 18 .0 0 5 10 15 20 25 30 35 40 45 50

(GPM) FLOW (LPM) (GPM) FLOW (LPM)


0 7 14 21 28 35 42 49 56 63 .0 0 15 30 45 60 75 90 105 120 135 150 165 180

.70 12AT ASSEMBLY 10B 20B


.70 50AT-2 ASSEMBLY 03B 10B
10 10
20B
.60 150 SUS .60 150 SUS
10C
(BAR)

(BAR)

8 8

.50 .50
PRESSURE DROP

PRESSURE DROP

.40 6 .40 6

.30 .30
4 4

.20 .20
(PSI)

(PSI)

2 2

.10 .10

0 0
.0 0 2 4 6 8 10 12 14 16 18 .0 0 5 10 15 20 25 30 35 40 45 50

(GPM) FLOW (LPM) (GPM) FLOW (LPM)


0 7 14 21 28 35 42 49 56 63 .0 0 15 30 45 60 75 90 105 120 135 150 165 180

Parker Hannifin Corporation


Hydraulic Filter Division
3 Metamora, OH
Spin-On Filters
12AT/50AT Series

Installation and Element Collapse Rating: Filter Material:


100 psid minimum Head: Aluminum
Specification Data Canister: Low Carbon Steel
Model 12AT Element Condition Indicators:
Gauge: Color coded 15/25 psi Shipping Weights (approximate):
Pressure Ratings: 1.6 lbs.
Maximum Allowable Operating Pressure Switch: Normally open
Pressure (MAOP): 150 psi (10.3 bar) 20 +/- 2 psi Gauge Port Locations:
5 Amps @ 24 VDC RI - Right side of inlet
Design Safety Factor: 2.5:1 LI - Left side of inlet
Vacuum Switch: Normally open RO - Right side of outlet
Operating Temperatures: 5" +/- 1" Hg LO - Left side of outlet
-40°F to 225°F (-40°C to 107°C) 1.0 Amp @ 120 VAC

LI LO
67.82
MAX
2.67
95.00
3.74
38.10
1.50

RI RO

95.25 Linear Measure: millimeter


3.75 inch
¼ - 20 UNC x .31 MIN
THREAD DEPTH
2-TOTAL

OPTIONAL 1/8 - 27 NPT 23.62


GAUGE PORT (RIGHT SIDE 27.43
1.08 .93
INLET SHOWN, PLUGGED) 47.62
1.875

INLET OUTLET
12.19
.48

PORTS (BOTH ENDS)


¾"-14 NPTF
OR
¾" SAE - 12

172.97MAX
6.81

148.84
5.68

15.7 MINIMUM
.62 REMOVAL
CLEARANCE

Parker Hannifin Corporation


Hydraulic Filter Division
4 Metamora, OH
Spin-On Filters
12AT/50AT Series

Installation and Element Collapse Rating: Filter Material:


100 psid minimum Head: Aluminum
Specification Data Canister: Low Carbon Steel
Model 50AT Element Condition Indicators:
Gauge: Color coded 15/25 psi Shipping Weights (approximate):
Pressure Ratings: Single length: 3.7 lbs.
Maximum Allowable Operating Pressure Switch: Normally open Double length: 5.3 lbs.
Pressure (MAOP): 150 psi (10.3 bar) 20 +/- 2 psi
5 Amps @ 24 VDC Gauge Port Locations:
Design Safety Factor: 2.5:1 RI - Right side of inlet
Vacuum Switch: Normally open LI - Left side of inlet
Operating Temperatures: 5" +/- 1" Hg RO - Right side of outlet
-40°F to 225°F (-40°C to 107°C) 1.0 Amp @ 120 VAC LO - Left side of outlet

Linear Measure: millimeter


inch

Ports: (both ends)


1¼"-11½" NPTF
or
1¼" SAE-20

Parker Hannifin Corporation


Hydraulic Filter Division
5 Metamora, OH
Spin-On Filters
12AT/50AT Series

Reservoir Model Air Rating* Element Adaptor Kit


Breather Assemblies
12AT and 50AT 12AT-03C 1 micron 926543 926876
12AT-10C 2 micron 921999 926876
Sizing
12AT-25C 5 micron 925023 926876
Select the proper size canister for the
maximum rate of reservoir draw down 50AT-03C 1 micron 926541 926875
or air exchange rate. As a rule of 50AT-10C 2 micron 926169 926875
thumb, clean pressure drop should be
limited to 0.18 psid (5" H2O). 50AT-25C 5 micron 926170 926875
* 99% Removal efficiency for particles larger than the stated size in air.
A pipe flange, weld collar, etc. may be
used to connect the canister adaptor Graphs are for 03C canisters only. Total pressure drop across
kit to the reservoir. Make sure that air canister, adaptor, and pipe may be found by adding pressure
is not able to leak around the adaptor. drops below:
When mounting on the side of the
reservoir, make sure the installation is + 1.5% for each inch of 12AT adaptor or 3/4" pipe used.
above the surface of the fluid. + 3.0% for each 3/4" elbow used.
+ 1.0% for each inch of 50AT adaptor or 1-1/4" pipe used.
Recommended canister change out + 2.0% for each 1-1/4" elbow used.
is after 500 hours of operation. More
frequent replacement may be re-
quired when operated in heavily TYPICAL INSTALLATIONS
contaminated areas such as grinding MOUNTED ON TOP
operations, primary metal mills, and OR SIDE OF
RESERVOIR
on mobile equipment. Under such
conditions, increase replacement
frequency to every 250 hours.

ALLOW 1.25" FOR CANISTER


REMOVAL CLEARANCE

10 .4

12AT
DIFFERENTIAL PRESSURE (IN H20)

8
DIFFERENTIAL PRESSURE (PSI)

.3
7

6
12AT
5
.2

4
50AT

3
50AT
.1
2

0
0 10 20 30 40 50 60 70 80 90 100 0 100 200 300 400 500 600

AIR FLOW (SCFM) OIL LEVEL CHANGE RATE (GPM)

Parker Hannifin Corporation


Hydraulic Filter Division
6 Metamora, OH
Spin-On Filters
12AT/50AT Series

Filter Service Accessory Parts List

Filter canisters need to be replaced Description 12AT 50AT


when the pressure gauge reads the Gauge - 15 psi 934238 934238
filter bypass setting. For example, if a Gauge - 25 psi 934237 934237
12AT filter has a 25 psi bypass valve,
Pressure switch-15 psi 926359 926359
it needs to be replaced when the
pressure gauge reads 25 psi. If no Pressure switch-25 psi 926923 926923
indicator of any kind is used, replace Vacuum switch 926949 926949
the canister after the first 50 hours of Breather adaptor kit 926876 926875
operation, and every 250 hours Vacuum gauge 934239 934239
thereafter. More frequent replacement
could be required depending on
operating conditions.
Replacement Canisters
When servicing a 12AT or 50AT filter,
use the following procedure: Media 12AT 50AT 50AT-2

A. Shut down the main system and 25C 925023 926170 N/A
release pressure in the filter line. 10C 921999 926169 927736
B. Unthread the canister and discard 03C 926543 926541 N/A
it along with the accompanying 20B 928764 928767 929446
seal. A strap wrench may be
10B 928763 928766 929445
required.
C. Apply a small amount of lubricant 03B N/A 934200 932073
to the new canister seal.
D. Install the new canister and hand
tighten.

15 15
10

20
10

1.0
20

1.0
12-30 PSI
COLOR BAND (RED) 20-30 PSI
1.5 0.5 1.5 COLOR BAND (RED)
0.5
25
25

5
5

2.0 2.0
bar bar

psi psi
30
30

Indicator Gauge (15 PSI) Indicator Gauge (25 PSI)

1/8-27 NPTF 1/8-27 NPTF

VACUUM SWITCH PRESSURE SWITCH

Parker Hannifin Corporation


Hydraulic Filter Division
7 Metamora, OH
Spin-On Filters
12AT/50AT Series

How To Order
Select the desired symbol (in the correct position) to construct a model code.
Example:

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

50AT 2 10C N 25 DD N

BOX 1: Seals BOX 4 : Canister Media BOX 7 : Ports


Symbol Description Symbol Description Symbol Description
None Buna 25C* Cellulose 12AT
10C Cellulose BB 3/4" NPTF
03C* Cellulose MM SAE-12
BOX 2 : Basic Assembly 20B Microglass 50AT
Symbol Description 10B Microglass DD 1-1/4" NPTF
12AT Spin-on (¾" nom.) 03B ** Microglass OO SAE-20
50AT Spin-on (1¼" nom.)
* Not available in 50AT-2
** Not available in 12AT BOX 8 : Gauge Port Location
BOX 3 : Length Symbol Description
Symbol Description N None
BOX 5 : Indicator
None Single length canister Symbol Description H Inlet and outlet,
2 Double length canister both sides
(50 AT only) N None
(all ports drilled
and tapped)
BOX 6 : Bypass Setting
Symbol Description
25 25 psid
15 15 psid
3 3 psid
X No bypass

NOTE: Gauges must be ordered separately.

Please note the bolded options reflect


standard options with a reduced
lead-time. Consult factory on all
other lead-time options.

Parker Hannifin Corporation


Hydraulic Filter Division
8 Metamora, OH
12S Series
High Pressure Filters

155
High Pressure Filters
12S Series

Features/Applications
■ Offshore – High pressure and aggressive environment
■ DI Water – Water fogging
■ Food Processing – Caustic washdown (poultry, etc.)
■ Test Stands – High pressure

Feature Advantage Benefit


Lightweight Ease of service and installation Reduced installation cost
Porting Flexibility Reduction in piping and use
of adaptors
Multipass tested elements Filter performance backed Filters you select have
(per ANSI/NFPA T3.10.8.8 by recognized and accepted known performance levels
R1-1990) laboratory test standards
Optional visual and Know exactly when to Keeps system clean
electrical indicators service elements
Drain port Drain all oil from assembly Eliminates cross contamination
prior to servicing
Optional upstream & Add additional instrumentation Product flexibility
downstream sensing ports
High strength Microglass III 2000 psid collapse strength High capacity with high efficiency
elements Multi-layer media No performance loss from
Wire reinforced pleats pleat bunching
100% pressure tested Quality Reliability

Parker Hannifin Corporation


Hydraulic Filter Division
156 Metamora, OH
High Pressure Filters
12S Series

12SMP (10,000 psi) Specifications

Pressure Ratings: Element Collapsing Rate:


Maximum Allowable Operating Pressure High Collapse “H” option: 2,000 psi (138 bar)
(MAOP): 10,000 psi (690 bar)
Materials:
Proof: 15,000 psi (1035 bar)
Head: Stainless Steel 316L
Operating Temperatures: Bowl: Stainless Steel 316L
Fluorocarbon (FKM) -15°F (-26°C) to 275°F (-135°C)
Weight (approximate):
Ethylene Propylene (EPR) -40°F (-40°C) to 225°F (-107°C)
Model Single Length Double Length
Perfluoroelastomer (FFKM) 5°F (-15°C) to 536°F ( 280°C)*
12SMP 14 lbs. (6.35 kg.) 17 lbs. (7.71 kg.)

* Consult factory when requesting this seal. A special element may


be required to withstand operating temperature.

12SHP (20,000 psi) Specifications


Pressure Ratings: Element Collapsing Rate:
Maximum Allowable Operating Pressure High Collapse “H” option: 2,000 psi (138 bar)
(MAOP): 20,000 psi (1,380 bar)
Materials:
Proof: 30,000 psi (2,070 bar)
Head: Stainless Steel 17-4
Operating Temperatures: Bowl: Stainless Steel 17-4
Fluorocarbon (FKM) -15°F (-26°C) to 275°F (-135°C)
Weight (approximate):
Ethylene Propylene (EPR) -40°F (-40°C) to 225°F (-107°C)
Model Single Length Double Length
Perfluoroelastomer (FFKM) 5°F (-15°C) to 536°F (-280°C)*
12SHP 14 lbs. (6.35 kg.) 17 lbs. (7.71 kg.)
* Consult factory when requesting this seal. A special element may
be required to withstand operating temperature.

2.34 (59.44) ELECTRICAL INDICATOR


1.44 (36.58) VISUAL INDICATOR

Dimensions
BURST TEST
PROOF TEST ON FILTER HOUSING

30000

PORT SIZES PER


25000 REQUIREMENTS
(BOTH SIDES)

20000

APPLY PST PIPE SEALANT


#567 TO THREADS
PSID

SINGLE LENGTH:
15000 8.09 (205.49) LUBRICATE O-RING
TORQUE BOWL TO
DOUBLE LENGTH: 75 ± 10 FT-LBS
11.80 (299.72)
10000

5000

0
OPTIONAL DRAIN PLUG
TORQUE SPECIFICATIONS:
TIME 1.00 SAE-4: 18-20 FT-LB
(25.4) 1/4 M/P: 20-25 FT-LB

INLET
.75 INLET
(19.05)
4.25 DIA. REF
I
I

.75
(19.05)
1.50
(38.1)
OPTIONAL
VISUAL/
ELECTRICAL
INDICATOR

3/8-16 UNC-2B x .63 MIN. OPTIONAL 1/4" NOM. PRESSURE


FULL THREAD SENSING PORTS (2 PLACES)
MOUNTING HOLES
O

(2 PLACES)
O

OUTLET OUTLET

Parker Hannifin Corporation


Hydraulic Filter Division
157 Metamora, OH
High Pressure Filters
12S Series

12S-1 Element Performance


Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10000 100

10Q

05Q
2Q 5Q
6
80

1000 99.9 5
10Q
60
4
200 99.5

20Q
100 99.0 3
20Q
40

2
20 95.0 02Q
20
1

2 50.0 0 0
0 1 2 3 4 5 6
Grams
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 10 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 10 20 30 40 50 60 70 0 20 40 60 80

25 25
150SUS HOUSINGS SAE-10
1.5 3/4 M/P
1.5
20 20

SAE-8
15 1.0
15 1.0
BAR
02Q
PSID
PSID

BAR

05Q 10Q

10 10
20Q
0.5 SAE-12 0.5
5 5
1 NPTF

0 0.0 0 0.0
0 5 10 15 20 0 5 10 15 20 25
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
158 Metamora, OH
High Pressure Filters
12S Series

12S-2 Element Performance

Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10000 100

05Q
2Q 6
5Q 80

20Q
99.9

02Q
5

10Q
1000
10Q
60
4
200 99.5
100 99.0 3
40
20Q
2
20 95.0
20
1

2 50.0 0 0
0 5 10 15 20
Grams
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 15 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 20 40 60 80 0 20 40 60 80
25 25
150SUS HOUSINGS SAE-10
1.5 3/4 M/P
1.5
20 20

SAE-8
15 1.0 15 1.0
PSID

PSID
BAR

BAR

02Q
10 10
05Q
10Q 0.5 SAE-12 0.5
20Q
5 5
1 NPTF

0 0.0 0 0.0
0 5 10 15 20 25 0 5 10 15 20 25
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
159 Metamora, OH
High Pressure Filters
12S Series

HOW TO ORDER:
Select the desired symbol (in the correct position) to construct a model code.

Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

12SMP 1 10QH SP MP 6 11

BOX 1: Basic Assembly BOX 6: Port Type1


Symbol Description Symbol Description
12SMP 10,000 psi MAOP (316 S.S.) S2 SAE O-ring port
12SHP 20,000 psi MAOP (17-4 S.S.) N3 NPTF port
MP Medium pressure Autoclave (M/P) type port
BOX 2: Length HP High pressure Autoclave (H/P) type port
Symbol Description
Notes: 1. For other options, please contact HFD
1 Single 2. Available for operating pressure <6,000 psi only
2 Double
3. Available for operating pressure <10,000 psi only

BOX 3: Element Media BOX 7: Port Size


Symbol Description Symbol Description (Port Type Options)
20QH 20µm Microglass III, 2000 psid collapse 4 1/4” Nominal (N, MP)
10QH 10µm Microglass III, 2000 psid collapse
6 3/8” Nominal (N, MP)
05QH 5µm Microglass III, 2000 psid collapse
02QH 2µm Microglass III, 2000 psid collapse 8 1/2” Nominal (N)
10 9/16” Nominal (MP, HP)
12 3/4” Nominal (S,N)
BOX 4: Seals
16 1” Nominal (S,N)
Symbol Description
None Fluorocarbon (FKM) BOX 8: Options
E1 Ethylene Propylene (EPR) Symbol Description
Note: 1.Recomended for DI Water applications 1 Bypass (60 psid)
11 No Bypass (standard)
BOX 5: Indicator 191 Bypass with 1/4” drian port
Symbol Description 211 No bypass with 1/4” drain port
N No Indicator, no pressure port
Note: 1.Drain port will be SAE or M/P Autoclave plug as
SP1 1/4” pressure ports only
4L352 Visual manual reset, 50 psid setting required. Plug is included.
5T352 Electrical (DIN 43650-A/ISO 4400), 50 psid setting
Note: 1.Pressure ports will match port type selected in BOX 6
2.Available for operating pressure <10,000 psi only

Replacement Elements
Microglass III (Fluorocarbon) Microglass III (Ethylene Propylene -EPR)
Media Single Double 12SMP-1 / 12SHP-1 12SMP-2 / 12SHP-2
20QH 403400 403404 403485 403488
No-Bypass 10QH 403399 403403 403484 403487
05QH 403398 403402 403483 403486
02QH 403397 403401 403482 403417
20QH 937442 937446 937474 937478
Bypass 10QH 937441 937445 937473 937477
05QH 937440 937444 937472 937476
02QH 937439 937443 937471 937475

Parker Hannifin Corporation


Hydraulic Filter Division
160 Metamora, OH
PARKER
DIFFERENTIAL PRESSURE TRANSMITTER
ITEM1: LZT‐2880‐1, DPI‐2882‐1, DPI‐2881‐1, DPI‐2883‐1, DPI‐2884‐1

PRESSURE TRANSMITTER
ITEM2: PT‐2880A‐1, PT‐2880C‐1, PZT‐2880‐1, PZT‐2880‐2, PT‐29XX‐4
<<Contents>> <<Index>>

General Model EJX110A


Specifications Differential Pressure Transmitter

GS 01C25B01-01E

The high performance differential pressure transmitter


model EJX110A features single crystal silicon reso-
nant sensor and is suitable to measure liquid, gas, or
steam flow as well as liquid level, density and pres-
sure. It outputs a 4 to 20 mA DC signal corresponding
to the measured differential pressure. Model EJX110A
also features remote setup and monitoring via commu-
nications with the BRAIN terminal or HART communi-
cator. By utilizing an unique feature of silicon reso-
nant sensor, static pressure can be monitored either
on the integral indicator or via communication.

 STANDARD SPECIFICATIONS
 SPAN AND RANGE LIMITS
Measurement
Span/Range kPa inH2O(/D1) mbar(/D3) mmH2O(/D4) Square Root Output Accuracy
L
Span 0.1 to 10 0.4 to 40 1 to 100 10 to 1000 The square root accuracy is a percent of flow span.
Range -10 to 10 -40 to 40 -100 to 100 -1000 to 1000
Span 0.5 to 100 2 to 400 5 to 1000 50 to 10000 Output Accuracy
M
Range -100 to 100 -400 to 400 -1000 to 1000 -10000 to 10000
50% or Greater Same as reference accuracy
Span 3.5 to 700 14 to 2800 35 to 7000 0.035 to 7 kgf/cm2
H Reference accuracy50
Range -700 to 700 -2800 to 2800 -7000 to 7000 -7 to 7 kgf/cm2 50% to Dropout point
T01E.EPS Square root output (%)
T00E.EPS
 PERFORMANCE SPECIFICATIONS
Ambient Temperature Effects per 28˚C (50˚F)
Zero-based calibrated span, linear output, wetted
Change
parts material code S and silicone oil, unless other-
wise mentioned. Capsule Effect
Specification Conformance M and H (0.04% Span0.009% URL)
EJX series ensures specification conformance to at L (0.1% Span0.05% URL)
least 3.
Reference Accuracy of Calibrated Span Static Pressure Effects per 6.9 MPa (1000 psi)
(includes terminal-based linearity, hysteresis, and Change
repeatability) Span Effects
Measurement span M H
L, M, and H capsules
0.075% of span
Reference X  Pressure 0.04% of Span Effect on Zero
accuracy M and H capsules
X  Pressure (0.0050.0035 URL/span)% of Span 0.02% of URL
10 kPa 70 kPa L capsule
X (40 inH2O) (10 psi) 0.05% of URL
URL 100 kPa 700 kPa Overpressure Effects
(the upper range limit) (400 inH2O) (100 psi)
Overpressure condition: up to maximum working
T02E.EPS
pressure
Measurement span L M and H capsules
0.03% of URL
Reference X  Pressure 0.04% of span
Stability (All normal operating condition, including
accuracy
X  Pressure (0.020.04 URL/span)% of span overpressure effects)
M and H capsules
2 kPa
X (8 inH2O) 0.1% of URL per 10 years
URL 10 kPa Power Supply Effects
(the upper range limit) (40 inH2O) 0.005 % per Volt (from 21.6 to 32 V DC, 350 )
T03E.EPS

Yokogawa Electric Corporation GS 01C25B01-01E


2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Dec. 2003
Phone: 81-422-52-5690 Fax.: 81-422-52-2018 Sales Release Version 2003
<<Contents>> <<Index>> 2
Gauge Pressure Reference
 Total Probable Error (M and H capsules) Gauge pressure reference is 1013 hPa (1 atm)
0.12% of Span @1:1 to 5:1 Rangedown Note : Gauge pressure variable is based on the above
Total probable error, known as a measure of the total fixed reference and thus subject to be affected by
the change of atomospheric pressure.
performance of the transmitters under the condition of
fixed line presurre.  FUNCTIONAL SPECIFICATIONS
Output
Total Probable Error  E12E22E32
Two wire 4 to 20 mA DC output with digital communi-
E1: Reference Accuracy of Calibrated Span cations, linear or square root programmable. BRAIN
E2: Ambient Temperature Effects per 28 C change or HART FSK protocol are superimposed on the 4 to
E3: Static Span Effects per 6.9 MPa change 20 mA signal.
Output range: 3.6 mA to 21.6 mA
Output limits conform to NAMUR NE43 can be pre-
 Total Accuracy (M and H capsules)
set by option C2 or C3.
0.12% of Span @1:1 Rangedown Failure Alarm
0.25% of Span @ 5:1 Rangedown Output status at CPU failure and hardware error;
Total accuracy is a comprehensive measure of transmitter Up-scale: 110%, 21.6 mA DC or more (standard)
total performance, covering all major factors in actual Down-scale: 5%, 3.2 mA DC or less
Note: Applicable for Output signal code D and E
installation, that cause errors in measurement.
As a standard measure, YOKOGAWA uses this to evaluate Damping Time Constant (1st order)
transmitter performance. Amplifier damping time constant is adjustable from 0
to 100.00 seconds and added to response time.
Total Accuracy  E12E22(E3E4)2E52 Note: For BRAIN protocol type, when amplifier damping
is set to 0.5 s or less, communication may
E1: Reference Accuracy of Calibrated Span occasionally be unavailble during the operation,
especially while output changes dynamically. The
E2: Ambient Temperature Effects per 28 C change
default setting of damping ensures stable
E3: Static Span Effects per 6.9 MPa change communication.
E4: Static Zero Effects per 6.9 MPa change
E5: Overpressure Effects upto overpressure 25MPa Update Period
Differential Pressure: 45 ms
Not only a day-to-day changes in temperature can affect Static Pressure: 360 ms
the measurement and lead to unnoticed errors; fluctuaion Zero Adjustment Limits
of line pressure, incorrect operation of three/five valve Zero can be fully elevated or suppressed, within the
manifold leading to over-pressure events, and other lower and upper range limits of the capsule.
phenomena can have the similar result. Total Accuracy External Zero Adjustment
factors in such changes and errors and provides much External Zero is continuously adjustable with 0.005%
comprehensive and practical determination of how a incremental resolution of span. Re-range can be
transmitter will perform under actual plant operation. done locally using the digital indicator with range-
setting switch.
Vibration Effects Integral Indicator (LCD display)
Less than 0.1% of URL when tested per the require- 5-digit Numerical Display, 6-digit Unit Display and Bar
ments of IEC60770-1 field or pipeline with high graph.
vibration level (10-60 Hz, 0.21 mm peak to peak The indicator is configurable to display one or up to
displacement/60-2000 Hz 3 g) four of the following variables periodically.;
Differential pressure in %, Scaled Differential
Mounting Position Effects pressure, Differential Pressure in Engineering unit,
Rotation in diaphragm plane has no effect. Tilting up to Static Pressure in Engineering unit.
90 degree will cause zero shift up to 0.4 kPa ( See “Setting When Shipped” for factory setting.
1.6 inH2O) which can be corrected by the zero
adjustment. Burst Pressure Limits
69 MPa (10000 psi)
Response Time (Differential pressure, all capsules)
95 ms  NORMAL OPERATING CONDITION
When amplifier damping is set to zero and including
dead time of 45 ms (nominal) (Optional features or approval codes may affect
Static Pressure Signal Accuracy limits.)
(For monitoring via communication or on Ambient Temperature Limits
indicator. Includes terminal-based linearity, 40 to 85˚C (40 to 185˚F)
30 to 80˚C (22 to 176˚F) with LCD display
hysteresis, and repeatability))
Process Temperature Limits
Absolute Pressure
40 to 120˚C (40 to 248˚F)
1MPa or higher : 0.2% of span
Less than 1 MPa: 0.2%(1 MPa/span) of span Ambient Humidity Limits
0 to 100% RH

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec.1, 2003-00
<<Contents>> <<Index>> 3
Working Pressure Limits (Silicone oil) Communication Requirements
Maximum Pressure Limits (Safety approvals may affect electrical require-
ments.)
L Capsule 16 MPa (2300 psi)
BRAIN
M and H Capsule 25 MPa (3600 psi)
Communication Distance
Minimum Pressure Limit Up to 2 km (1.25 miles) when using CEV polyethyl-
See graph below ene-insulated PVC-sheathed cables. Communication
distance varies depending on type of cable used.
100{14.5} Atmospheric
Load Capacitance
pressure 0.22 F or less
Working
pressure Load Inductance
kPa abs
{psi abs} 3.3 mH or less
Applicable range Input Impedance of communicating device
10{1.4}
10 k or more at 2.4 kHz.

2.7{0.38}
HART
Communication Distance
1{0.14} Up to 1.5 km {1 mile} when using multiple twisted pair
-40 0 40 80 120
(-40) (32) (104) (176) (248) cables. Communication distance varies depending on
Process temperature C ( F) type of cable used.
F01E.EPS

Figure 1. Working Pressure and Process Temperature


Use the following formula to determine cable length
for specific applications:

Supply & Load Requirements 65  106 (Cf + 10,000)


L= -
(R  C) C
(Optional features or safety approvals may affect
electrical requirements.) Where:
With 24 V DC supply, up to a 570  load can be L = length in meters or feet
used. See graph below. R = resistance in  (including barrier resistance)
C = cable capacitance in pF/m or pF/ft
Cf = maximum shunt capacitance of receiving devices
in pF/m or pF/ft
600 EMC Conformity Standards ,
E-10.5 EN 61326, AS/NZS 2064
R=
0.0236 Digital
External
load
Communication
range  PHYSICAL SPECIFICATIONS
resistance BRAIN and HART
Wetted Parts Materials
250
Diaphragm, Cover Flange, Process Connector,
R () Capsule Gasket, and Vent/Drain Plug
Refer to “MODEL AND SUFFIX CODE.”
Process Connector Gasket
10.5 16.4 24.7 42 PTFE Teflon
Power supply voltage E (V DC)
F02E.EPS
Fluorinated rubber for Option code /N2 and /N3
Figure 2. Relationship Between Power Supply Voltage Non-wetted Parts Materials
and External Load Resistance Bolting
ASTM-B7M carbon steel, 316 SST(ISO A4-70)
stainless steel, or ASTM grade 660 stainless steel
Supply Voltage Housing
10.5 to 42 V DC for general use and flameproof type. Low copper cast aluminum alloy with polyurethane,
10.5 to 32 V DC for lightning protector (Option code mint-green paint (Munsell 5.6BG 3.3/2.9 or its
/A). equivalent)
10.5 to 30 V DC for intrinsically safe, type n, non- Degrees of Protection
incendive or non-sparking type.
IP67, NEMA4X, JIS C0920
Minimum voltage limited at 16.4 V DC for digital
communications, BRAIN and HART Cover O-rings
Buna-N
Load (Output signal code D and E)
0 to 1335  for operation Name plate and tag
250 to 600  for digital communication 304 SST

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 4
Fill Fluid
Silicone, Fluorinated oil (option)
Weight
[Installation code 7, 8 and 9]
2.7 kg (6.0 lbs) without integral indicator, mounting
bracket, and process connector.
Connections
Refer to “MODEL AND SUFFIX CODE.”

< Related Instruments>


Power Distributor: Refer to GS 01B04T01-02E or
GS 01B04T02-00E
BRAIN TERMINAL: Refer to GS 01C00A11-00E

< Reference >


1. Teflon; Trademark of E.I. DuPont de Nemours & Co.
2. Hastelloy; Trademark of Haynes International Inc.
3. HART; Trademark of the HART Communication
Foundation.
Other company names and product names used in this
material are registered tradmarks or trademarks of
their respective owners.

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 5
 MODEL AND SUFFIX CODES
Model Suffix Codes Description
EJX110A ························· Differential pressure transmitter
Output Signal -D · · · · · · · · · · · · · · · · · · · · · · · 4 to 20 mA DC with digital communication (BRAIN protocol)
-E · · · · · · · · · · · · · · · · · · · · · · · 4 to 20 mA DC with digital communication (HART protocol)
Measurement L ····················· 0.1 to 10 kPa (0.4 to 40 inH2O)
span (capsule) M····················· 0.5 to 100 kPa (2 to 400 inH2O)
H····················· 3.5 to 700 kPa (14 to 2800 inH2O)

Wetted parts S ···················


– ··················· Refer to "Wetted Parts Material" Table below.
material
– ···················
– ···················
– ···················
– ···················
– ···················

Process connections 0·················· without process connector (Rc1/4 female on the cover flanges)
1·················· with Rc1/4 female process connector
2·················· with Rc1/2 female process connector
3· · · · · · · · · · · · · · · · · · with 1/4 NPT female process connector
4· · · · · · · · · · · · · · · · · · with 1/2 NPT female process connector
 5· · · · · · · · · · · · · · · · · · without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material J · · · · · · · · · · · · · · · · ASTM-B7M carbon steel
 G················ 316 SST (ISO A4-70) stainless steel
C················ ASTM grade 660 stainless steel
Installation -7 · · · · · · · · · · · · · · Vertical piping, left side high pressure, and process connection downside
-8 · · · · · · · · · · · · · · Horizontal piping and right side high pressure
 -9 · · · · · · · · · · · · · · Horizontal piping and left side high pressure
Amplifier housing 1············ Cast alluminum alloy

Electrical connection 0··········· G1/2 female, one electrical connection without blind plugs
 2··········· 1/2 NPT female, one electrical connection without blind plugs
4··········· M20 female, one electrical connection without blind plugs
5··········· G1/2 female, two electrical connections and a blind plug
7··········· 1/2 NPT female, two electrical connections and a blind plug
9··········· M20 female, two electrical connections and a blind plug
Integral indicator D········ Digital indicator
E········ Digital indicator with the range setting switch
 N········ None
Mounting bracket B ····· 304 SST 2-inch pipe mounting (flat type)
D ····· 304 SST 2-inch pipe mounting (L type)
N ····· None
T04E.EPS
Contact Yokogawa representative for the suffix codes indicated as ‘-’.
The “” marks indicate the most typical selection for each specification.

*1: Cast version of 316SST. Equivalent to SCS14A.

Table. Wetted Parts Materials


Wetted parts Cover flange and
Capsule Capsule gasket Drain/Vent plug
material code process connector

# Hastelloy C-276 (Diaphragm)


S ASTM CF-8M Teflon-coated 316L SST 316 SST
316L SST (Others)
– # ASTM CF-8M Hastelloy C-276 PTFE (Teflon) 316 SST
– ASTM CF-8M Monel PTFE (Teflon) 316 SST
– ASTM CF-8M Tantalum PTFE (Teflon) 316 SST
– # Hastelloy C-276 euivalent Hastelloy C-276 PTFE (Teflon) Hastelloy C-276
– Hastelloy C-276 euivalent Tantalum PTFE (Teflon) Hastelloy C-276
– Monel equivalent Monel PTFE (Teflon) Monel
M04E.EPS

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of
316 SST material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 6
 OPTIONAL SPECIFICATIONS (For Explosion Protected type)
Item Description Code
FM Explosionproof Approval *1
Explosionproof for Class I, Division 1, Groups B, C and D
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G –
Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
Factory Mutual (FM)
FM Intrinsically safe Approval *1
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1 Hazardous Locations. –
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups E, F & G, and Class III, Division 1 Hazardous Locations.
Combined FF1 and FS1 *1 –
ATEX (KEMA) Flameproof Approval *1

II 2G EExd IIC T4, T5, T6
ATEX ATEX (KEMA) Intrinsically safe Approval *1
II 1G EEx ia IIC T4 –
Combined KF2, KS2 and Type n *1
Type n: II 3G EEx nL IIC T4 –
CSA Explosionproof Approval *1
Explosionproof for Class I, Division 1, Groups B, C and D –
Canadian Standards Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Association (CSA)
CSA Intrinsically safe Approval *1
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x –
Combined CF1 and CS1 *1 –
T05E.EPS
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 3, 7, and 9.

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 7
 OPTIONAL SPECIFICATION
Item Description Code
Terminal cover only P
Color change
Painting Both sides of amplifier covers, Munsell 7.5 R4/14 PR
Coating change Anti-corrosion coating X2
Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically
Lightning protector safe type.) A
Allowable current: Max. 6000 A ( 140 s ), Repeating 1000 A ( 140 s ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Degrease cleansing treatment K1
Oil-prohibited use*1 Degrease cleansing treatment and with fluorinated oilfilled capsule.
Operating temperature 20 to 80 C( -4 to 176 F) K2

Degrease cleansing treatment and dehydrating treatment K5


Oil-prohibited use
with dehydrating treatment*1 Degrease cleansing treatment and dehydrating treatment with fluorinated oilfilled capsule.
Operating temperature 20 to 80 C( -4 to 176 F) K6

Capsule fill fluid Flourinated oil filled in capsule K3


P calibration (psi unit) D1
Calibration units*2 (See Table for Span and
bar calibration (bar unit) D3
Range Limits.)
M calibration (kgf/cm2 unit) D4
Total length: 119 mm (standard: 34 mm); Total length when combining with Optional code
Long vent*3 U
K1, K2, K5, and K6: 130 mm. Material: 316SST.
Failure alarm down-scale : Output status at CPU failure and hardware error is
Output limits C1
-5%, 3.2mA DC or less.
and failure operation*4
NAMUR NE43 Compliant Failure alarm down-scale : Output status at CPU
C2
Output signal limits : 3.8 mA to failure and hardware error is -5%, 3.2 mA DC or less.
20.5 mA Failure alarm up-scale : Output status at CPU C3
failure and hardware error is -110%, 21.6 mA or more.
Without drain and vent plugs N1
N1 and Process connection, based on IEC61518 with female thread on both sides of
N2
Body option*5 cover flange, with blind kidney flanges on back.
N1, N2, and Material certificate for cover flange, diaphragm, capsule body, and blind
N3
kidney flange
Stainless steel tag plate 304SST tag plate wired onto transmitter N4
Data configuration for HART communication type Software damping, Descriptor, Memo CA
Data configuration at factory*6
Data configuration for BRAIN communication type Software damping CB
Cover flange *8 M01
Material certificate*7
Cover flange, Process connector *9 M11
Pressure test/ Test Pressure: 16 MPa(2300 psi)*10 Nitrogen(N2) Gas*12 T12
Leak test certificate Test Pressure: 25 MPa(3600 psi)*11 Retention time: one minute T13
T06E.EPS
*1: Applicable for Wetted parts material code S,.
*2: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by Optional code
D1, D3, and D4.
*3: Applicable for vertical impulse piping type (Installation code 7) and Wetted parts material code S.
*4: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule.
*5: Applicable for Wetted parts material code S; Process connection code 3, 4, and 5; Installation code 9; and Mounting
bracket code N. Process connection faces on the other side of zero adjustment screw.
*6: Also see ‘Ordering Instructions’.
*7: Material traceability certification, per EN 10204 3.1B.
*8: Applicable for Process connections code 0 and 5.
*9: Applicable for Process connections code 1, 2, 3, and 4.
*10: Applicable for Capsule code L.
*11: Applicable for Capsule code M, H and V.
*12: Pure nitrogen gas is used for oil-prohibited use (Optional code K1, K2, K5, and K6).

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 8
 DIMENSIONS
 Model EJX110A
Vertical Impulse Piping Type
Process connector upside (INSTALLATION CODE '7')
Unit : mm (approx.inch)

(0.23)
240(9.45)

6
177(6.97) 110(4.33)

(2.13)
97 129 12

54
(3.82) (5.08) (0.47) 39
(1.54) 2-inch pipe
(O.D. 60.5 mm)
Electrical connection
Mounting bracket for code 5 and 9. Vent/drain
(2.05)

(L-type, Optional)
52

plugs
Vent/drain plugs Conduit
connection
223(9.17)
97(3.82)

ø69(2.72)
ø77(3.03)
95(3.74)

138(5.43)
(1.61)
(2.64)
41
67

Internal
Zero indicator
adjustment (Optional)
Ground High 54
Low
Process connector terminal pressure (2.13) pressure
(Optional) side side
F03E.EPS

Horizontal Impulse Piping Type (INSTALLATION CODE '9') (For CODE '8', refer to the notes below.)
54 89(3.50) 67(2.64) Conduit 110 (4.33)
6 connection Zero
adjustment 12
95(3.74) (0.47) 39
Integral (1.54)
Indicator
ø77(3.03)

(optional)

(2.72)
ø69
(5.75)

Electrical connection
146

177(6.97)

for code 5 and 9.

(5.08)
129
Ground
terminal

Vent plug

Drain plug
Process
(4.88)

Low
124

connection
41 High pressure
(1.61) pressure side
side
115
(4.53)
(1.85)
47

Mounting bracket
2-inch pipe
(Flat-type, optional) (O.D. 60.5mm)
54
(2.13)
117
(4.61)
* 1: When Installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 9

● Terminal Configuration ● Terminal Wiring


Communication
Terminals(BT200 etc.) CHECK METER
Connection hook Connection hook*1 SUPPLY +
– Power supply and output terminal

+
CHECK – External indicator(ammeter) terminal*1

Ground terminal

E
PULS
SUP
PLY
K
CHEC M
ALAR
*1: When using an external indicator or a check meter,
the internal resistance must be 10  or less.
CHECK +
SUPPLY +
F05E.EPS
SUPPLY - CHECK -

< Ordering Information >


Specify the following when ordering < Factory Setting >
1. Model, suffix codes, and optional codes Tag Number As specified in order
2. Calibration range and units:
1) Calibration range can be specified with range Amplifier
Damping *1 ‘2 sec.’ or as specified in order
value specifications up to 5 digits
(excluding any decimal point) for low or high range Output Mode ‘Linear’ unless otherwise specified in order
limits within the range of -32000 to 32000. When Calibration Range
reverse range is designated, specify URV as greater Lower Range Value As specified in order
than LRV. Calibration Range As specified in order
2) Specify only one unit from the table, ‘Settings Upper Range Value
when shipped.’ Selected from mmH2O, mmH2O(68˚F),
3. Select linear or square root for output mode and Calibration Range mmAq, mmWG, mmHg, Pa, hPa, kPa,
Units
display mode. MPa, mbar, bar, gf/cm2, kgf/cm2, inH2O,
Note: If not specified, the instrument is shipped set for inH2O(68˚F),inHg, ftH2O, ftH2O(68˚F) or
linear mode. psi. (Only one unit can be specified)

Display Setting Designated differential pressure value


4. Display scale and units (for transmitters equipped specified in order. (%, Engineering unit or
with integral indicator only) user scaled value.) Display mode 'Linear'
Specify either 0 to 100 % or engineering unit scale or 'Square root' is also as specified in
and ‘Range and Unit’ for engineering units scale: order.
Scale range can be specified with range limit Periodic display of differential pressure
specifications up to 5 digits (excluding any decimal and static pressure can be set at factory
point) for low or high range limits within the range of when /CA or /CB option is specified.
-32000 to 32000.
Static Pressure '0 to 25MPa' for M and H capsule and
If periodic display of differential pressure and static Display Range*1 '0 to 16MPa' for L capsule, unless
pressure is designated, also specify the following otherwise specified in order. Display unit
items fro static pressure. is selectable from the units listed in
1) 0 and 100% scale value for bar-graph. above 'Calibration Range Units'.
2) Specify one unit from the table, ‘Settings when T07E.EPS
shipped.’ *1: To specify these items at factory, /CA or /CB option
5. Tag Number (if required). is required.
For BRAIN communication type, specify upto 16
letters. The specified letters will be written in the
amplifier memory and engraved on the tag plate.
For HART communication type, specify software tag
(upto 8 letters) to be written on the amplifier memory
and Tag number(upto 16 letters) to be engraved on
the tag plate seperately.
6. Other factory configurations (if required)
Specifying option code /CA or /CB will allow further
configuration at factory. Following are configurable
items and setting range.
[/CA : For HART communication type]
1) Descriptor(upto 16 characters)
2) Memo (upto 32 characters)
3) Amplifier damping (0.0 to 100.00 sec)
[/CB : For BRAIN communication type]
1) Amplifier damping (0.0 to 100.00 sec)

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation GS 01C25B01-01E Dec. 1, 2003-00
<<Contents>> <<Index>> 10

All Rights Reserved. Copyright © 2003, Yokogawa Electric Corporation


ALLEN BRADLEY
ILLUMINATED PUSH BUTTON
ITEM1: HS‐2880A‐1, HS‐2880B‐1, HS‐2880C‐1, HS‐2880D‐1, HS‐2880E‐1




 

   


 

 

  

   



   

 









     
      
    
   




   


      

    

    



 

      
      
 
     
 
   






 
        
       
   


  
 
    

    
 
    


    




  
    
 
    
 
     

 
    




    
  
  
  
 
  
      
 

  
  
   
 
   
   
     
 


 

 




   
   
 
   
 
    

 







 
    
     
    







 

 
MACIS
FLOW CONTROL VALVE
ITEM1: MFCV

VOLUME BOTTLE
ITEM2: MVB

PILOT OPERATED VALVE


ITEM3: MPV

HYDRAULIC INTERFACE VALVE


ITEM4: MHV1, MHV2

PRESSURE RELIEF
ITEM5: MPRV
70

 ,62
&HUW1R&,,(
2+6$6
&HUW1R&,6

         0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
)/2:&21752/9$/9(6 36,  
7<3(0$&,69$/9(




,1
 287

7:2:$<

 )/2:&21752/9$/9(6


,1 287
137

137





00


25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(

9DOYH7\SH 09 09


,QOHW&RQQHFWLRQ 137 7DSHU ´)´ 
2XWOHW&RQQHFWLRQ 137 7DSHU ´)´ 
3KRWRGUDZLQJVKRZDUHVWDQGDUGLWHPV FXVWRPL]HWKUHDGDUHDYDLODEOH 
9DOYH2SWLRQV %
$ 0DOHFRQQHFWLRQ% )HPDOHFRQQHFWLRQ
:RUNLQJ0HGLD 6WDQGDUG  /LTXLG 2LO  /LTXLG 2LO 
:RUNLQJ0HGLD 2SWLRQV  $LURU+\GURFDUERQ*DV 
3UHVVXUH5DQJH SVL   0D[   0D[ 
&RQWURO)XQFWLRQ 7ZR:D\ 

2ULILFH6L]H ‘
%RG\6KDSH +H[DJRQ $)00 
9DOYH6HDW0DW O 6WDQGDUG  6WDLQOHVV6WHHO±686
9DOYH6HDW0DW O 2SWLRQV  2WKHUPDWHULDOVZLOOEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW
6HDO0DWHULDO 6WDQGDUG2ULQJ 
'U\:HLJKW NJ  
:RUNLQJ7HPSHUDWXUH5DQJH ƒ&WRƒ&
)ORZ5DWH &Y 

0$&,63WH/WG   %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO  )D[  (PDLOVDOHV#PDFLVFRPVJ  :HEVLWHZZZPDFLVFRPVJ
70

 ,62
&HUW1R&,,(
2+6$6
&HUW1R&,6

         0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
$,56725$*(7$1. 36, 7:2:$< 12  
7<3(0$&,69$/9($67

200
 137


,1

 ,1 287
00

 7:2:$<
1250$//<23(1
$,56725$*(7$1.

287


25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(

9DOYH7\SH 09$67 09$67


,QOHW&RQQHFWLRQ ´137 7DSHU ´)´ ´137³)´
2XWOHW&RQQHFWLRQ ´137 7DSHU ´)´ ´137´)´
:RUNLQJ0HGLD 6WDQGDUG  $LURU+\GURFDUERQ*DV 
)ORZ&RQWURO$SSOLFDWLRQ 1RUPDOO\2SHQ 
&RQWURO)XQFWLRQ 7ZR:D\ 
3UHVVXUH5DQJH SVL   0D[   0D[ 

2ULILFH6L]H ‘ 
,QWHUQDO6WRUDJH&DSDFLW\ OLWHU   
9DOYH6HDW0DW O 6WDQGDUG  6WDLQOHVV6WHHO686 
9DOYH6HDW0DW O 2SWLRQV  2WKHUPDWHULDOVFDQEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW 
6HDO0DWHULDO 6WDQGDUG2ULQJ  
'U\:HLJKW NJ   
:RUNLQJ7HPSHUDWXUH5DQJH ƒ&WRƒ& 

0$&,63WH/WG   %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO  )D[  (PDLOVDOHV#PDFLVFRPVJ  :HEVLWHZZZPDFLVFRPVJ
TM

ISO 14001:2004 OHSAS 18001:2007


Cert. No: CI/ 3995IE Cert. No: CIS/

MACIS High Pressure & Control Technology


PILOT OPERATED VALVES (THREE-WAY)
TYPE:MACIS VALVE 29171-54-H-C
1/8-27NPT
PILOT

/
MOUNTING HOLE (O7.0MM)
EX
1/4-18NPT

PILOT

OUT
87MM

1/4-18NPT

11MM OUT
EX
IN

IN
55.5MM
51.9MM

11MM 3-WAY 2-POSITION


1/4-18NPT

NORMALLY CLOSED
PILOT OPERATER VALVES
39MM

39MM
26.3MM

22.6MM

ORDERING
TECHNICAL SPECIFICATION EXAMPLE

Valve Type: MV 29171-54-H-C MV 29171-54-H-C


Inlet Connection: 1/4"-18NPT (Taper)”F”
Outlet Connection: 1/4"-18NPT (Taper)”F”
Exhaust Connection: 1/4"-18NPT (Taper)”F”
Pilot Connection: 1/8"-27NPT (Taper)”F”
Working Media: (Standard) Liquid (Oil)
Inlet Pressure Range:(psi) 200(Max) 200(Max)
Pilot Pressure Range:(psi) 200(Max) 200(Max)
Flow Control Application: Normally Closed Normally Closed

Body Shape Hexagon (A/F 34.925MM)


Valve Seat Mat'l: (Standard) Stainless Steel – SUS316
Valve Seat Mat'l: (Options) Other materials will be provided according to customer’s request.
Seal Material: Standard O-ring
Dry Weight: (kg) 0.6
Working Temperature Range: -30°C to 120°C
Flow Rate: Cv=1.6

MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
TM

ISO 14001:2004 OHSAS 18001:2007


Cert. No: CI/ 3995IE Cert. No: CIS/

MACIS High Pressure & Control Technology


INTERFACE VALVES(10000PSI)(THREE-WAY)(NC)
TYPE: MACIS VALVE B29AM10K3W-3/8NC-3/8E-1/8P-N

PANEL NUT
/
Panel Hole Size Required:O22.5mm
1/8NPT

PIOLT
PILOT

OUT
(132.5MM)

SUPPLY
EX
(126.5MM)

(NC)
(118MM)

EX
3/8NPT

OUT
3-WAY 2-POSITION
(38.5MM) 3/8NPT

NORMALLY CLOSED
(57.5MM)

IN
3/8NPT
(20MM)

ORDERING
TECHNICAL SPECIFICATION EXAMPLE

Valve Type: MV B29AM10K3W-3/8NC-3/8E-1/8P-N MV B29AM10K3W-3/8NC-3/8E-1/8P-N


Inlet Connection: 3/8"-18NPT (Taper)”F”
Exhaust Connection: 3/8"-18NPT (Taper)”F”
Outlet Connection: 3/8"-18NPT (Taper)”F”
Pilot Connection: 1/8"-27NPT (Taper)”F”
Flow Control Application: Normally Closed
Control Function: Three-Way
Working Media: (Standard) Liquid(Oil) Liquid(Oil)
Working Media: (Options) Air or Hydrocarbon Gas
Pressure Range:(psi) 10000 (Max) W.P. 10000(Max)
Pilot Pressure Range(psi) 150(Max)
Manual Override Handle: Rotating screw type
Panel Hole Size Required: Ø22.5mm
Valve Seat Mat'l: (Standard) Stainless Steel – SUS316
Valve Seat Mat'l: (Options) Other materials will be provided according to customer’s request.
Seal Material: Teflon‚Standard O-ring and Ceramic Ball
Dry Weight: (kg) 2.4
Working Temperature Range: -30°C to 120°C
Flow Rate: Cv=0.36

MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
TM

ISO 14001:2004 OHSAS 18001:2007


Cert. No: CI/ 3995IE Cert. No: CIS/

MACIS High Pressure & Control Technology


INTERFACE VALVES(10000PSI)(THREE-WAY)(NC)
TYPE: MACIS VALVE B29AM10K3W-1/4NC-1/4E-1/8P-N

PANEL NUT
/
Panel Hole Size Required:O22.5mm
1/8NPT

PIOLT
PILOT

SUPPLY OUT
(132.5MM)
(126.5MM)

EX (NC)
EX
(118MM)

1/4NPT

OUT 3-WAY 2-POSITION


NORMALLY CLOSED
(38.5MM) 1/4NPT
(57.5MM)

IN
1/4NPT
(20MM)

ORDERING
TECHNICAL SPECIFICATION EXAMPLE

Valve Type: MV B29AM10K3W-1/4NC-1/4E-1/8P-N MV B29AM10K3W-1/4NC-1/4E-1/8P-N


Inlet Connection: 1/4"-18NPT (Taper)”F”
Exhaust Connection: 1/4"-18NPT (Taper)”F”
Outlet Connection: 1/4"-18NPT (Taper)”F”
Pilot Connection: 1/8"-27NPT (Taper)”F”
Flow Control Application: Normally Closed
Control Function: Three-Way
Working Media: (Standard) Liquid(Oil) Liquid(Oil)
Working Media: (Options) Air or Hydrocarbon Gas
Pressure Range:(psi) 10000 (Max) W.P. 10000(Max)
Pilot Pressure Range(psi) 150(Max)
Manual Override Handle Rotating screw type

Panel Hole Size Required: Ø22.5mm


Valve Seat Mat'l: (Standard) Stainless Steel – SUS316
Valve Seat Mat'l: (Options) Other materials will be provided according to customer’s request.
Seal Material: Teflon ‚Standard O-ring and Ceramic Ball
Dry Weight: (kg) 2.4
Working Temperature Range: -30°C to 120°C
Flow Rate: Cv=0.36

MACIS Pte Ltd BLK 3015A Ubi Road 1 #01-02/01-06 Kampong Ubi Industrial Estate Singapore 408705
Tel:65-6749 6011/6749 7882 Fax:65-6749 1398 E-mail:sales@macis.com.sg Website:www.macis.com.sg
70

 ,62
&HUW1R&,,(
2+6$6
&HUW1R&,6

         0$&,6+LJK3UHVVXUH &RQWURO7HFKQRORJ\
5(/,()9$/9(6 36, 7:2:$< 1&  
7<3(0$&,69$/9(...


 35(6685(6(77,1*187

 287
00

137


00

287 ,1


00 7:2:$<
1250$//<&/26('
 5(/,()9$/9(6


,1


137


25'(5,1*
7(&+1,&$/63(&,),&$7,21 (;$03/(

9DOYH7\SH 09. 09. 09. 09.


,QOHW&RQQHFWLRQ 137 7DSHU ´)´ 
2XWOHW&RQQHFWLRQ 137 7DSHU ´)´ 
3KRWRGUDZLQJVKRZDUHVWDQGDUGLWHPV FXVWRPL]HWKUHDGDUHDYDLODEOH 
9DOYH2SWLRQV %
$ 0DOHFRQQHFWLRQ% )HPDOHFRQQHFWLRQ
&RQWURO)XQFWLRQ 7ZR:D\ 
:RUNLQJ0HGLD 6WDQGDUG  /LTXLG 2LO  /LTXLG 2LO 
:RUNLQJ0HGLD 2SWLRQV  $LURU+\GURFDUERQ*DV 
3UHVVXUH5DQJH SVL      VHW 

2ULILFH6L]H PP  ‘ 
9DOYH6HDW0DW O 6WDQGDUG  6WDLQOHVV6WHHO±686 
9DOYH6HDW0DW O 2SWLRQV  2WKHUPDWHULDOVZLOOEHSURYLGHGDFFRUGLQJWRFXVWRPHU¶VUHTXHVW 
6HDO0DWHULDO 6WDQGDUG2ULQJDQG&HUDPLF%DOO 
'U\:HLJKW NJ   
:RUNLQJ7HPSHUDWXUH5DQJH ƒ&WRƒ& 

g/HDNWLJKWZKHQRI³VHWSUHVVXUH´LVDSSOLHG
g5HSHDWDELOLW\ fRI³VHWSUHVVXUH´
g5HVHDWLQJZLWKLQRI³FUDFNLQJSUHVVXUH´6WDWHGHWDLOVZKHQRUGHULQJ

0$&,63WH/WG   %/.$8EL5RDG.DPSRQJ8EL,QGXVWULDO(VWDWH6LQJDSRUH
7HO  )D[  (PDLOVDOHV#PDFLVFRPVJ  :HEVLWHZZZPDFLVFRPVJ
RSTAHL
START PUSHBUTTON
ITEM1: HS‐2880A‐1A, HS‐2880B‐1A, HS‐2880C‐1A, HS‐2880D‐1A, HS‐
2883‐1A, HS‐SCSSV‐0, HS‐SCSSV‐C, HS‐SSV‐O, HS‐SSV‐C, HS‐WV‐O, HS‐
WV‐C, HS‐LGV‐O, HS‐LGV‐C

STOP PUSHBUTTON
ITEM2: HS‐2880A‐1B/G, HS‐2880B‐1B/G, HS‐2880C‐1B/G, HS‐2880D‐
1B/G, HS‐2883‐1B/G

LAMP INDICATOR
ITEM3: XA‐2880A‐1, XA‐2880B‐1, XA‐2880C‐1, XA‐2880D‐1, XA‐2883‐1,
XA‐2800‐1

ESD/USD PUSH BUTTON


ITEM4: ESD2‐WHCP/HPU, ESD3‐WHCP/HPU, HZ‐2941, HZ‐2942, HZ‐2943,
HZ‐2944, HZ‐2945

LIGHTING& EMERGANCY LINGTING


Series Panel Mounted Control Devices CONTROL DEVICES

• Suitable for hazardous and


Series Features:

corrosive locations.
• Installation is easy and
precise.
• Devices fit into a standard
30.5mm, 1.2" knock-out.
• Tightening the retainer nut
makes installation complete.
• Available with cage clamp
terminals or leads
for easy connection.

E
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
8003 PUSHBUTTONS AND CONTROL SWITCHES

Technical Data
Enclosure Material Polyamide

Contact Material Silver-Nickel

NEC- Class I, Zone 1 & 2, AEx de IIC T6


CLASSIFICATIONS

Class I, Division 2, Groups A,B,C,D


Mechanical/Electrical Life 106 Operations

* Class II, Division 2, Groups F,G


* Class III
Terminal Wire Capacity 2 x 18 to 2 x 12 AWG

Environmental Protection 4, 4X, IP66,


Wire Leads 4 Core, 18 AWG

Front, depending on enclosure (see table –


“Enclosure Type Rating For Installation”)
Contact AC switching capacity UL A 600 (600VAC 10A)

File No. E 182378


Contacts DC switching capacity 110V Max. 1 Amp. Max.
Lowest Energy 12V AC/DC, 50 mA*

CEC- Class I, Zones 1 & 2, Ex de IIC T6


Knockout for 8003

Class I, Division 2, Groups A,B,C,D


*For lower energy use gold plated contacts, available on request.

Enclosure Type Rating For Installation


* Class II, Divisions 2, Groups F,G
* Class III
* UL applied for
Area Classification Pushbutton with Cap 8003/1•1 or Pushbutton with Cage Clamps 8003/1•2
Gas Explosion Protection
0f Use with Cap and Lead 8003/1•3 (without Cap)
8003/1•1 and 8003/1•3
II 2 G EEx de IIC T6
Class I Zone 1 Enclosure Type➀ 1, 2, 3, 3R, 4, 4X, 12, 13 Enclosure AEx e, Ex e
Class I Division 2
8003/1•2
Enclosure Type 1, 2 ,3, 3R, 4, 4X, 12. 13
Groups A, B, C, D
II 2 G EEx de IIC Class II Division 2 Enclosure Type 3, 4, 4X, 12, 13

Dust Explosion Protection


Groups F, G

8003/1••
II 2 D IP66 T80°C
Class III Enclosure Type 3 ,4, 4X, 12, 13

Certificates for Gas and Dust Explosion


➀Terminate in “Increased Safety” Enclosure.

8003/1•1 and 8003/1•3


PTB 02 ATEX 1057 X

Certificate for Gas Explosion


8003/1•2
PTB 02 ATEX 1080 U

Ambient Temperature Range:


+55°C (+131˚F) Max.
–30°C (–22˚F) Min.

FEATURES
The 8003 pushbutton and control switch series
are typically mounted in an electrical panel or
enclosure, for custom control applications.
They come with different actuators, contact
arrangements and connection options as
indicated on pages E2, E3 and E4.

Installation is easy and precise. To install,


simply snap through a standard 30.5mm
(1.20") pushbutton knockout. Hand tightening of
the retainer nut makes the installation complete.
The pushbuttons are suitable for hazardous
(classified) locations in conjunction with the
appropriate enclosure type (see above table for
“Enclosure Type Rating For Installation”).

E1
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES

1123
Ordering Information
PUSHBUTTONS

1224
Connection
Options
11 21

12 22
13 23
Actuator
Options

With Cage Clamps & Cap With Cage Clamps With Cap & 20' Lead 14 24

Descriptions C A T A L O G N U M B E R Contacts

Momentary 8003/111-001 8003/112-001 8003/113-001-6 NC/NO


Pushbutton
1.5" (38mm) O.D. 8003/121-001 8003/122-001 8003/123-001-6 NC/NC
With two legend
disks START 8003/131-001 8003/132-001 8003/133-001-6 NO/NO
STOP.➁

Emergency Stop 8003/111-009 8003/112-009 8003/113-009-6 NC/NO


Red Mushroom
1.5" (38mm) O.D. 8003/121-009 8003/122-009 8003/123-009-6 NC/NC
Maintained action.
Key-to-Release from
maintained position.➀

Mushroom Black 8003/111-006 8003/112-006 8003/113-006-6 NC/NO


1.5" (38mm) O.D.
Maintained action. 8003/121-006 8003/122-006 8003/123-006-6 NC/NC
Key-to-Release from
maintained position. 8003/131-006 8003/132-006 8003/133-006-6 NO/NO

Emergency Stop 8003/111-010 8003/112-010 8003/113-010-6 NC/NO


Red Mushroom
Pushbutton 8003/121-010 8003/122-010 8003/123-010-6 NC/NC
1.5" (38mm) O.D.
Maintained action.
Turn-to-Release.➀

Emergency Stop 8003/111-015 8003/112-015 8003/113-015-6 NC/NO


(Jumbo)
Red Mushroom 8003/121-015 8003/122-015 8003/123-015-6 NC/NC
Pushbutton
2.16" (55mm) O.D.
Maintained action.
Turn-to-Release.➀

Mushroom
Pushbutton 8003/111-012 8003/112-012 8003/113-012-6 NC/NO
Maintained Black
with Red Legend 8003/121-012 8003/122-012 8003/123-012-6 NC/NC
Disk
1.5" (38mm) O.D. 8003/131-012 8003/132-012 8003/133-012-6 NO/NO
Maintained action.
Turn-to-Release.➁

Mushroom
Pushbutton Black
8003/111-003 8003/112-003 8003/113-003-6 NC/NO
1 .5" (38mm) O.D.
Momentary action.
8003/121-003 8003/122-003 8003/123-003-6 NC/NC
With black snap-in
legend disk.➁
8003/131-003 8003/132-003 8003/133-003-6 NO/NO

➀Yellow plastic washer for E-STOP function is enclosed.

E2
➁Other legend disks must be ordered separately. See Page E7.

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357


CONTROL DEVICES Series Panel Mounted Control Devices
8003 SELECTOR SWITCHES

CATALOG CATALOG
CONTACT ARRANGEMENTS CONTACT ARRANGEMENTS

8003/11■■-■■ ■ ■ -2-r 8003/14■■-■■ ■ ■ -2-r


NUMBER NUMBER

maintained maintained
maintained maintained

8003/11■■-■■ ■ ■ -2-t 8003/14■■-■■ ■ ■ -2-t

maintained maintained
spring return spring return

8003/12■■-■■ ■ ■ -2-r 8003/11■■-■■ ■ ■ -3-rr

maintained maintained
maintained maintained
maintained

8003/12■■-■■ ■ ■ -2-t 8003/11■■-■■ ■ ■ -3-rt


maintained
maintained maintained
spring return spring return

8003/13■■-■■ ■ ■ -2-r 8003/11■■-■■ ■ ■ -3-tr


spring return
maintained maintained
maintained maintained

8003/13■■-■■ ■ ■ -2-t 8003/11■■-■■ ■ ■ -3-tt


spring return
maintained maintained
spring return spring return

1 2
1 3

With Cage Clamps & Cap With Cage Clamps With Cap & 20' Lead

E3
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES

8003 SELECTOR SWITCHES

CATALOG CATALOG
CONTACT ARRANGEMENTS CONTACT ARRANGEMENTS

8003/12■■-■■ ■ ■ -3-rr 8003/13■■-■■ ■ ■ -3-tr


NUMBER NUMBER

maintained spring return


maintained maintained
maintained maintained

8003/12■■-■■ ■ ■ -3-rt 8003/13■■-■■ ■ ■ -3-tt


maintained spring return
maintained maintained
spring return spring return

8003/12■■-■■ ■ ■ -3-tr 8003/14■■-■■ ■ ■ -3-rr


spring return maintained
maintained maintained
maintained maintained

8003/12■■-■■ ■ ■ -3-tt 8003/14■■-■■ ■ ■ -3-rt


spring return maintained
maintained maintained
spring return spring return

8003/13■■-■■ ■ ■ -3-rr 8003/14■■-■■ ■ ■ -3-tr


maintained spring return
maintained maintained
maintained maintained

8003/13■■-■■ ■ ■ -3-rt 8003/14■■-■■ ■ ■ -3-tt


maintained spring return
maintained maintained
spring return spring return

726 727 008 Standard:


Key removable in all positions.
Key type: MS 1

Special:
Non-removable key positions need to be specified.
Non-lockable Pad-lockable Key Operated Other key types than MS 1 available.

E4
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices

Technical Data
8013/3 LED PILOT LIGHTS

Material - Enclosure Polyamide

Material - Bezel/Lens Polyamide

For standard type 8013/31•


CLASSIFICATIONS Mechanical/Electrical Life 10 Output Hours
5

NEC- Class I, Zone 1, AEx dem IIC T6


Class I, Division 2, Groups A,B,C,D
Rated Voltage - Standard 12V to 254V AC or DC 0-60 Hz

* Class II, Division 2, Groups F,G


* Class III
Rated Voltage - I. S. 10.8V to 28V AC or DC

Rated Current 14 mA at 24V DC

File No. E182378


CEC- Class I, Zones 1 & 2, Ex dem IIC T6
Rated Power 0.6W

Class I, Division 2, Groups A,B,C,D


Colors red, amber, green, blue and white

* Class II, Divisions 2, Groups F,G


* Class III
Wire Leads 2 Core, 18 AWG

II 2G EEx mde IIC (T6)


Terminal Capacity 2 x 16 or 2 x 14 AWG per terminal

II 2D IP66 T80°C V max 28V


Intrinsic Safety Ratings Entity Parameters

8013/311 and 8013/313 PTB 02 ATEX 2131X


Enclosure Knock-out 30.5 mm or 1.2" I.D.

I max 150 mA
8013/312 PTB 02 ATEX 2130U
P max 1W
Li 0
Ci 0
For I. S. version 8013/32•
CLASSIFICATIONS

Enclosure Type Rating For Installation


*NEC- Class I, Zone 1, AEx d ia m IIC T4
Class I, II, III, Division 1, Groups C-G T4;
*CEC- Class I, Zone 1, Ex d ia m IIC T4
Class I, II, III, Division 1, Groups C-G T4;
Area Classification Pilot Light with Cap 8013/3•1 or Pilot Light with Cage Clamps 8013/3•2

* UL applied for
of Use with Cap & Lead 8013/1•3 (without Cap)
Class I, Zone 1 Enclosure Type➀ 1, 2, 3, 3R, 4, 4X, 12, 13 Enclosure AEx e, Ex e
II 2G EEx md ia IIC (T6)
8013/321 & 8013/323 PTB 02 ATEX 2131X
Class I, Div. 1, I.S. Type 1, 2, 3, 3R, 4, 4X, 12, 13

8013/322 PTB 02 ATEX 2130U Class I, Division 2


Environmental Protection 3, 4, 4X; IP66 Front,
Enclosure Type 1, 2 ,3, 3R, 4, 4X, 12, 13

depending on enclosure (see table –


Groups A, B, C, D

“Enclosure Type Rating For Installation”)


Class II, Division 2 Enclosure Type 4, 4X, 12, 13
Ambient Temperature Range:
Groups F, G

+55°C (+131˚F) Max.


–30°C (–22˚F) Min.
Class III Enclosure Type 4, 4X, 12, 13

FEATURES:
The 8013/3 Series of Pilot Lights are avail-
➀Terminate in “Increased Safety” Enclosure.

able for standard – and I.S. application. The


Pilot Lights for standard application
8013/31•-al are capable to work on volt-

Ordering Information
ages between 12V up to 254V AC/DC.
The types 8013/32•-al are for connection
with intrinsically safe circuits only and oper-
ate safely within the values stated in the
above table “Intrinsic Safety Ratings Entity
Connection

Parameters”.
Options

The installation should be in accordance


with ANSI/ISA RP 12. 06. 01.
Recommended Barrier: 9002/13-252-121-041 Applications

All these pilot lights come with a clear,


color-neutral bezel and can be colored with
With Cage Clamps & Cap With Cage Clamps With Cap & 20' Lead

one snap-on lens. There are five lenses


Descriptions C A T A L O G N U M B E R
included in the package, colored red,
8013/311-al 8013/312-al 8013/313-al-6
amber, green, blue and white for the user
to choose from.
Standard -
12V to 254V AC/DC

8013/321-al 8013/322-al 8013/323-al-6


For I.S. Circuits
10.8V to 28V AC/DC

E5
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES

8018/3 ILLUMINATED PUSHBUTTONS

Technical Data
ENCLOSURE
Material - Enclosure Polyamide
Material - Bezel Polyamide
Colors red, amber, green, blue and white

NEC- Class I, Zone 1, AEx dm IIC T6


Wire Leads 6 Core, 18 AWG, 20' Length CLASSIFICATIONS

Class I, Division 2, Groups A,B,C,D


Enclosure Knock-out 30.5 mm or 1.2" I.D.
Class II, Division 2, Groups F,G
Class III
CONTACTS
Material Silver-Nickel

CEC- Class I, Zones 1 & 2, Ex dm IIC T6


Contact Life 106 Operations

Class I, Division 2, Groups A,B,C,D


* Class II, Division 2, Groups F,G
Lowest Energy 12V AC/DC, 50 mA*

* Class III
Contact Switching Capacity AC – A600 (600V AC, 10A) Knockout for 8018

* UL applied for
DC – 110V Max. 1 Amp Max.
LED PILOT LIGHT

File No. E182378


LED Life 105 Output Hours

Environmental Protection 3, 4, 4X; IP66


Rated Voltage 12V to 254V AC/DC 0-60 Hz

depending on enclosure (see table –


Rated Current 14 mA at 24V DC

“Enclosure Type Rating For Installation”)


Rated Power 0.6W

II 2 G EEx dm IIC T6
*For lower energy use gold plated contacts, available on request.

II 2 D IP66 T80°C
Enclosure Type Rating For Installation PTB 02 ATEX 2129X
IP66 depending on enclosure

Ambient Temperature Range:


Area Classification

+55°C (+131˚F) Max.


Illuminated Pushbutton with Lead
of Use
Class I Zone 1 Enclosure Type➀ 1, 2, 3, 3R, 4, 4X, 12, 13 –30°C (–22˚F) Min.
Class I Division 2 Enclosure Type 1, 2 ,3, 3R, 4, 4X, 12, 13
Groups A, B, C, D
Class II Division 2 Enclosure Type 3, 4, 4X, 12, 13
Groups F, G
Class III Enclosure Type 3 ,4, 4X, 12, 13
➀Terminate in “Increased Safety” Enclosure.

Ordering Information
Description Wire Connections CATALOG NUMBER

8018/3113-al-6 FEATURES:
Illuminated
Pushbutton

The illuminated Pushbutton for panel


Spring Return
mounting Series 8018/3 combines control
1 NC and 1 NO
and indicating functions. One actuator oper-
ates two contacts and simultaneously can
indicate their actual operating status by
8018/3123-al-6
Illuminated
means of an LED. All illuminated
Pushbutton
Pushbuttons are spring return action and
come with a clear bezel and five colored
Spring Return

snap-in filter disks, red, amber, green, blue


2 NC

and white. All disks are included in the


package for the user to choose from.
8018/3133-al-6
Illuminated
Pushbutton
Spring Return
2 NO

E6
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
ACCESSORIES AND SPARE PARTS

Ordering Information
DESIGNATION ILLUSTRATION DESCRIPTION CATALOG NUMBER
Spare For all key-operated buttons/
Keys key-operated switches
Standard version MS 1 3746050
Special key, specify number 3746060

Pushbutton Blank, Legend Disk Blue 86 029 34 85 6


Legend Blank, Legend Disk Amber 86 029 35 85 6
Disks Blank, Legend Disk Red 86 029 30 85 6
Blank, Legend Disk Green 86 029 31 85 6
Blank, Legend Disk White 86 029 33 85 6
Blank, Legend Disk Black 86 029 32 85 6
Red, Legend Disk “STOP” 86 029 03 84 0
Green, Legend Disc “START” 86 029 09 84 0
Red, Legend Disk “OFF” 86 029 05 84 0
Green, Legend Disk “ON” 86 029 06 84 0
Green, Legend Disk “I” 86 029 07 84 0
Green, Legend Disk “II” 86 029 08 84 0
Red, Legend Disk “O” 86 029 02 84 0
Red, Legend Disk Arrow 86 029 01 84 0
Black, Legend Disk “UP” 86 029 32 85 0 “UP”
Black, Legend Disk “DOWN” 86 029 32 85 0 “DOWN”
Black, Legend Disk “RUN” 86 029 32 85 0 “RUN”
Black, Legend Disk “SLOW” 86 029 32 85 0 “SLOW”
Black, Legend Disk “FAST” 86 029 32 85 0 “FAST”
Black, Legend Disk “CLOSE” 86 029 25 84 0
Black, Legend Disk “OPEN” 86 029 23 84 0
Black, Legend Disk “AUTO” 86 029 32 85 0 “AUTO”
Black, Legend Disk “RIGHT” 86 029 32 85 0 “RIGHT”
Black, Legend Disk “LEFT” 86 029 32 85 0 “LEFT”
Black, Legend Disk “HAND” 86 029 32 85 0 “HAND”
Black, Legend Disk “RESET” 86 029 32 85 0 “RESET”
Black, Legend Disk “OFF-ON” 86 029 32 85 0 “OFF-ON”
Black, Legend Disk Arrow 86 029 11 84 0
Black, Legend Disk Arrow 86 029 12 84 0

Inserts HAND 0 AUTO 86 029 09 85 0


OFF • ON 86 029 08 85 0
0/OFF I/ON 86 029 01 85 0
blank 1 line text 86 029 10 85 0
blank 2 lines text 86 029 24 85 0

Legend Small Legend Frame 86 029 04 80 0


Frames for one line
Large Legend Frame 86 029 07 80 0
for two lines

Actuator for illuminated pushbutton


(spring-return) 86 020 24 03 0

Color Filter Snap-in Color Filters


white 86 029 25 58 0
red 86 029 26 58 0
amber 86 029 27 58 0
green 86 029 28 58 0
blue 86 029 29 58 0

Close-up To close-up unused mounting


Plug holes I.D. 1.2" (30.5mm) 86 028 01 58 7

E7
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES
DIMENSIONS

8003/1••-003, -010, -012


Mushroom Buttons
Mushroom E-STOP Button
8003/1••-006, Mushroom 8003/1••-726,
Black Key Button Control Switch Handle
8003/1••-009, E-STOP Red Non-Lockable
Mushroom, Key Button

8003/1•1-001 Momentary 8003/1•2-001 Momentary


Pushbutton with Pushbutton with Cage
Cage Clamps & Cap Clamps 8003/1••-015 E-STOP
Red Mushroom
Pushbutton
8003/1••-008 8003/1••-727,
Key Operated Switch Control Switch Handle
Pad-Lockable

Standard Knock-out Distance for Standard Knock-out Distance Knock-out Distance for Aligning Several
Jumbo E-STOP Button with / without Legend Frame devices with O.D. 1.49"(38mm) in a Panel
(8003/1••-015 Mushroom Maintained)

8018 Illuminated Pushbutton


8013/3•1 Pilot Light with Cap 8013/3•2 Pilot Light without Cap with Lead

E8
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
CONTROL DEVICES Series Panel Mounted Control Devices
8415 LED PILOT LIGHT ASSEMBLY

Technical Data
Mechanical/Electrical Life 105 Output Hours

Rated Voltage - Standard 12V to 254V AC or DC 0-60 Hz

For Pilot Light 8010/2 and Bezel 8602


CLASSIFICATIONS Voltage Tolerance -10% +6%
NEC- Class I, Zones 1 & 2, AEx de IIC T6
Class I, Division 2, Groups A,B,C,D
Rated Voltage - I. S. 10.8V to 28V AC or DC

Class II, Division 2, Groups F,G


Class III
Rated Current 15 mA at 24V DC

File No. E182378


Rated Power 1W max. Knockout for 8415
CEC- Class I, Zones 1 & 2, Ex de IIC T6
Class I, Division 2, Groups A,B,C,D
Colors red, amber, green, blue and white
V max 28V
Intrinsic Safety Ratings Entity Parameters

Class II, Divisions 1 & 2, Groups E,F,G I max 150 mA


Terminal Capacity 2 x 12 AWG (2.5mm2)
Class III P max 1W
Certified File No. LR99480-26 Li 0
Enclosure Knock-out 30.5 mm or 1.2" I.D.

Ci 0
II 2G EEx de IIC
Enclosure/Lens Material Polyamide

PTB 01 ATEX 1160 U


Enclosure Type Rating For Installation
PTB 01 ATEX 1129 U

For I. S. Pilot Light 8010/3 and Bezel 8602


CLASSIFICATIONS Area Classification

NEC- Class I, Zone 0, AEx ia/ib IIB T4


Pilot Light
of Use

Class I, Zone 1, AEx ia/ib IIC T4


Class I, Division 1, Groups A,B,C,D;
Class I Zone 1 Enclosure AEx e

CEC- Class I, Zone 0, Ex ia/ib IIB T4


Class I Div. 1, Zone 0 I.S. Enclosure Type 1, 2, 3, 3R, 4, 4X, 12, 13

Class I, Zone 1, Ex ia/ib IIC T4


Class I, Division 1, Groups A,B,C,D;
Class I Division 2 Enclosure Type 1, 2 ,3, 3R, 4, 4X, 12, 13
Groups A, B, C, D

File Nos. E81680 and E182378 Class II Division 1


II 2G EEx d ia/ib IIC
Enclosure Type 3, 4, 4X, 9, 12, 13

PTB 01 ATEX 1160 U


Groups E, G

PTB 01 ATEX 1129 U


Class II Division 2 Enclosure Type 3, 4, 4X, 12, 13
Ambient Temperature Range:
Groups E, G

+55°C (+131˚F) Max.


–25°C (–13˚F) Min.
Class III Enclosure Type 3 ,4, 4X, 12, 13

Environmental Protection 3, 4, 4X; IP66


front, depending on enclosure (see table –
“Enclosure Type Rating For Installation”)

FEATURES: Ordering Information


The 8415 Pilot Light assembly consists
of an LED/power pack 8010/3, one APPLICATIONS LENS COLORS CATALOG NUMBER
mounting bracket and one bezel/lens
assembly. Five different colors are avail-
able: red, green, amber, white and blue. red
Standard
The 8415 Pilot Light assemblies are
8415/24-R-9
green
available for power circuits – and intrin- 12V – 10% to
8415/24-G-9
amber
sically safe circuits. The types for 254V + 6%
8415/24-A-9

power applications 8415/24 are capable white


AC/DC
to work on voltages between 12V up
8415/24-W-9
blue
to 254V AC/DC.
8415/24-B-9
red
The types 8415/24-50 are for connec-
8415/24-50-R-9

tion with intrinsically safe circuits only, For I.S. green


and operate safely within the values
8415/24-50-G-9
Circuits amber
stated in the above table “Intrinsic
8415/24-50-A-9
10.8-28V AC/DC white
Safety Rating Entity Parameters”. 8415/24-50-W-9

The installation should be in accordance blue


with ANSI/ISA RP 12. 06. 01. and control
8415/24-50-B-9

drawing 80 106 01 31 3.
Recommended Barrier:
9002/13-252-121-041.

E9
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Panel Mounted Control Devices CONTROL DEVICES

8703 PUSHBUTTON ASSEMBLY

Contact Block Information


CONTACT SYMBOL INDIVIDUAL
DESCRIPTION ORDER
IEC NEMA CATALOG NUMBER

Single contact
block, 1 NC
CLASSIFICATIONS for Contact

NEC- Class I, Zones 1 & 2 AEx de IIC T6


8082/1-1-00 Block 8082/1 and Actuator 8602
Single contact Class I, Division 2, Groups A,B,C,D
block, 1 NO Class II, Division 2, Groups F,G
8082/1-2-00

Class III

Technical Data of Contact Block


Environmental Protection 3, 4, 4X;
IP66 Front, depending on enclosure
NEC/CEC IEC (see table – “Enclosure Type Rating
Rated Voltage 600VAC 500VAC For Installation”)
Continuous Current 10A 6A
Terminals 12AWG 2.5mm2 File No. E182378
Mechanical Life ≥ 106 operations
CEC- Class I, Zones 1 & 2 Ex de IIC T6
Electrical Life ≥ 106 operations
Class I, Division 2, Groups A,B,C,D
Housing Material polyamide Class II, Divisions 2, Groups F,G
Contact Material silver plated Class III
Lowest Energy 50mA. @ 12V* CERTIFIED - FILE No. LR99480-26

II 2 G EEx de IIC
Enclosure Type Rating For Installation PTB 00 ATEX 1031 U
PTB 01 ATEX 1129 U

FEATURES:
Area Classification
Pushbutton 8703

The 8703 pushbutton assembly con-


of Use

sisst of contact block(s) 8082/1, one


Class I Zone 1 Enclosure AEx e, Ex e

mounting bracket and one actuator


8602 - as listed on page F7.
Class I Division 2 Enclosure Type 1, 2 ,3, 3R, 4, 4X, 12, 13

The contact blocks have a single


Groups A, B, C, D

contact either 1 NC or 1 NO.


Class II Division 2 Enclosure Type 3, 4, 4X, 12, 13
The terminals are accessible from the
Groups F, G

front, therefor the wires need to be


connected before the contact block
Class III Enclosure Type 3 ,4, 4X, 12, 13

is snapped into the bracket.

Ordering Information
PUSHBUTTON
CATALOG NUMBER
CONTACTS

1 NC 8703/01 - ❐❐ -9

1 NO 8703/02 - ❐❐ -9

1 NC / 1 NO 8703/12 - ❐❐ -9

2 NC 8703/11 - ❐❐ -9

2 NO
Knockout for 8703
8703/22 - ❐❐ -9

Fill out the blanks in the Catalog Number with the information found on
pages F7 or F8 in the column “ACTUATOR CODE” (actuator code 23 not
possible).

E10
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
NOTES Notes

E11
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
> As pendant light fitting or side
entry lamp
> Version with 1 or 2 lamps:
18 W, 36 W and 58 W E2
> Central locking
> All-pole disconnection by means
of an N/C switch when the lamp
is opened E2
> End of life switch 1 and 2
(only 6000)

E2

E2
www.stahl.de

E2
Series EXLUX 6000 / 6400 E2

00280E00

E2
The lights of the Series EXLUX 6000 and EXLUX 6400 can be used
for normal lighting but also for an emergency light which is supplied
with current via a group or a central system.
E2
ATEX / IECEx / GOST NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
E2
EXLUX 6000 x x x x EXLUX 6000 x x EXLUX 6000 x x x x x
For use in: For use in: For use in:
EXLUX 6400 x*) x*) x*) EXLUX 6400 x EXLUX 6400 x x x x x
For use in: For use in: For use in:
*) ATEX E2

E2

E2

E2

WebCode 6000A
E2
2012-06-19·EK00·III·en Lighting E2/1
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400

Selection Table
Version Lamp wattage Number of lamps Electronic ballast Order number Weight
W kg
Light Fittings for Fluo- 18 1 1 channel EB 6000/521-8..1-013. 4.500
rescent Lamps (Zone
2 2 channel EB 6000/522-9..1-013. 6.800
1) Series 6000
36 1 1 channel EB 6000/541-8..1-013. 7.300
2 2 channel EB 6000/542-9..1-013. 9.100
01968E00
58 1 1 channel EB 6000/561-8..1-013. 10.200
2 2 channel EB 6000/562-9..1-013. 10.800
Side entry lamp (Zone 18 1 1 channel EB 6000/821-8081-0130 6.200
1) Series 6000
2 2 channel EB 6000/822-9081-6130 8.000
36 1 1 channel EB 6000/841-8081-0130 9.600
2 2 channel EB 6000/842-9081-0130 9.600
01962E00

Light Fittings for Fluo- 18 1 1 channel EB 6400/521-8..0-213. 4.100


rescent Lamps (Zo-
2 2x 1 channel EB 6400/522-9..0-213. 4.200
nes 2, 21, 22) Series
6400 36 1 1 channel EB 6400/541-8..0-213. 6.900
2 2x 1 channel EB 6400/542-9..0-213. 7.000

01968E00
58 1 1 channel EB 6400/561-8..0-213. 8.700
2 2x 1 channel EB 6400/562-9..0-213. 8.800
Side entry lamp (Zo- 18 2 2 channel EB 6400/822-9080-6130 6.300
nes 2, 21, 22) Series
36 2 1 channel EB 6400/841-8080-0130 9.100
6400

01962E00

Order Number Supplement


Through wiring without 6000/...-.0..-....
with 3 conductors 6000/...-.3..-....
with 5 conductors 6000/...-.5..-....
Cable glands Standard 1 x M25 x 1.5 cable gland and 6000/...-..1.-....
2 x M25 x 1.5 stopping plugs

Special Specify non-standard gland parts 6000/...-..9.-....

Monitoring module without 6000/...-....-...0 6.900


6048/131-02 address component (STAHL) 6000/...-....-...2 9.000
EB with extended for 110 ... 240 V (only 18 and 36 W) 6000/...-....-4....
voltage range
for 120 ... 277 V (17, 32 and 40 W NEC standard) 6000/...-....-8...
Note
The lights are delivered without fluorescent lamps and assembly parts.
These parts must be ordered separately!

E2/2 Lighting 2012-06-19·EK00·III·en


Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
Explosion Protection
Global (IECEx)
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Gas and dust IECEx PTB 05.0018
Ex d e IIC T4 E2
Ex tD A21 IP65 T80°C / T90°C
Europe (ATEX)
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Gas PTB 97 ATEX 2031 SNCH 03 ATEX 3517
E II 2 G Ex d e IIC T4 E II 3 G EEx nA II T6 (T4 bei Ta = 55°C)
at 18 W
E2
E II 3 G EEx nA II T4 bei 36 und 58 W
Dust PTB 97 ATEX 2031 Zone 21: SNCH 03 ATEX 3516
Zone 22: SNCH 03 ATEX 3517
E II 2 D Ex tD A21 IP 65 T80°C / T90°C E II 2 D IP66 T80°C ** T95°C at Ta ( 55°C
Certificates and approvals E2
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Certificates IECEx, ATEX, Brazil (UL do Brasil), India ATEX, Canada (CSA), USA (FM)
(PESO), Canada (CSA), Kazakhstan
(GOST-K), Russia (GOST-R), Ukraine
(GOST-U), USA (FM), Belarus (GOST-B),
Serbia (IZP), Corea KGS), China (CQST) E2
Other approvals ship approval (GL)
Further parameters
Marking (CE) C 0158 C 0158

Technical Data
Electrical data
E2
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Rated voltage
Electronic ballast AC: 220 (- 10%) ... 240 (+ 10%) V, 50 / 60 Hz

EB with extended
DC: 198 ... 254 V/ 1 lamp: 176 ... 264 V
6000/...-....-4... (18 and 36 W lamps) E2
voltage range AC: 110 (- 10%) ... 240 (+ 10%) V, 50 / 60 Hz
DC: 104 ... 264 V
6000/...-....-8... (17, 32 and 40 W NEC lamps)
AC: 120 (- 10%) ... 277 (+ 10%) V, 50 / 60 Hz
DC: 113 ... 294 V
Nominal operational for lights of the versions for lights of the versions E2
current IEC 60081 18 W 36 W 58 W
18 W 36 W 58 W with 2 0.18 A 0.33 A 0.49 A
with 1 lamps 0.08 A 0.16 A 0.25 A lamps
with 2 lamps 0.17 A 0.32 A 0.50 A
ANSI C78.1 E2
17 W 32 W 40 W
with 1 lamps 0.15 A 0.28 A 0.36 A
with 2 lamps 0.30 A 0.56 A 0.72 A
Power factor cos p cos p ) 0.97 capacitive; no additional cos p ) 0.97 capacitive; no additional
compensation required compensation required E2
Disconnection of the light When opening the light In case of a lamp fault, the electronic ballast
Switch with safety lock; when opening the disconnects the defective lamp from the power
central lock, all poles of the voltage supply to supply.
the ballast are disconnected; contacts of the
switching element are NC contacts, they can
only be switched on again when the lamp cover
and the central locking system are closed.
E2
In case of a lamp fault, the electronic ballast
disconnects the defective lamp from the power
supply.
End of life switch The electronic ballast, type 6042/9..-. fulfills the
requirements according to IEC 61347-2-3
(simulation of the "end of life effect" of
E2
fluorescent lamps, "asymmetric pulse test 1"
and "asymmetric power test 2" correspond to
the test conditions in the draft IEC 60079-7 ed.4
appendix H).
E2

E2
2012-06-19·EK00·III·en Lighting E2/3
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400

Technical Data
Luminous Characteristics
Lamps Fluorescent lamps with two-pin cap; Fluorescent lamps with two-pin cap;
T8;cap G13, according to IEC 60081 T8; cap G13, according to IEC 60081
Standard light: 1 x 18 W 2 x 18 W Standard light: 1 x 18 W 2 x 18 W
1 x 36 W 2 x 36 W 1 x 36 W 2 x 36 W
1 x 58 W 2 x 58 W 1 x 58 W 2 x 58 W
Side entry lamp: 1 x 18 W 2 x 18 W Side entry lamp: 1 x 18 W 2 x 18 W
1 x 36 W 2 x 36 W 1 x 36 W 2 x 36 W
Fluorescent lamps with two-pin cap; T8;
cap G13, according to ANSI C78.1
Standard light: 1 x 17 W 2 x 17 W
1 x 32 W 2 x 32 W
1 x 40 W 2 x 40 W
Side entry lamp: 1 x 17 W 2 x 17 W
1 x 32 W 2 x 32 W
Measures for light Standard: Deep bowl, reflector of the lamp is white
guidance Lateral dazzle limitation in the lamp cover
Special Additional reflector (can be easily mounted), deep broad bowl, polished aluminium
Operational efficiency broad beam
18 W / 36 W / 58 W with 1 lamps 83 %
with 2 lamps 76 %
Ambient conditions
Version EXLUX 6000 (Zone 1, 2, 21, 22) EXLUX 6400 (Zones 2, 21, 22)
Operating temperature 18 (17) W: - 25 ... + 55 °C - 30 ... + 55 °C
range 36 (32) W: - 25 ... + 55 °C
58 (40) W: - 25 ... + 50 °C
Mechanical data
Degree of protection IP66 IP66
IP64 when using the breather 8162 IP64 when using the breathing gland 8162
(according to EN 60529) (according to EN 60529)
Protection class I(with internal PE connection)
Material
Enclosure Polyester resin, glass fibre-reinforcedColour white, similar to RAL 9010colour white, similar to
RAL 9010
Gasket Polyurethane foam gasket in the lamp cover
Lamp cover Polycarbonate
Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13,
hinged lamp cover
Assembly / Installation
Cable glands Standard light
Plastic 1 x M25 x 1.5 cable gland 8161 and
2 x M25 x 1.5 stopping plugs 8290 (enclosed)
Metal: 2 x metal plates M20 connected by means of PE for metal cable glands
Attention: cable glands must be ordered separately
Special: max. 4 holes M20, M25, NPT ½’’
max. 2 holes NPT ¾’’
Metal cable glands: M20, M25; earthing of the metal gland parts by means
of metal plates
Side entry lamp
In case of a pole mount adapter mounted in factory: 1 x M32 x 1.5 cable gland 8161
1 x M25 x 1.5 stopping plugs 8290 (enclosed in the delivery)
1 x M25 x 1.5 breathing gland (enclosed in the delivery)
Connection Standard: Terminal block with cover
Designation: L1 + N + PE (3-pin) or L1 + L2 + L3 + N + PE (5-pin)
Terminal capacity: max 2 x 6 mm2 (single-wire); 2 x 4 mm2 (finely stranded)
Special Cage clamp terminals
Terminal capacity: max 2 x 2,5 mm2 (single-wire); 2 x 2,5 mm2 (finely stranded)
(3 free terminals available)

E2/4 Lighting 2012-06-19·EK00·III·en


Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
Technical Data
Through wiring Looping of the Standard light
cables On the connection side, there are two possibilities M25 x 1.5 for the
looping of the connecting line
(entry and exit on one side), also possible with lights subsequently
fitted with pole mount adapter.
E2
Through wiring Standard light Lights are available with internal through wiring.
Entry and exit holes for connecting cables are positioned on the op-
posite sides. A through-wiring kit can be installed later (see acces-
sories). Terminals: see Technical data.
Wiring cross-section 2.5 mm for max. 16 A E2
Assembly For outdoor installation, a breathing gland is recommended
Standard light
Standard: 2 x M8 insert nuts in the enclosure E2
Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for va-
riable light installation (variable mounting distances for lights 18 W (17 W):
312 ... 465 mm; 36 W (32 W)/ 58 W (40 W): 670 ... 865 mm)
A pole mount adapter can also be fitted to the standard light
Side entry lamp
E2
The light is mounted on a tube adapter, diameter 42 mm, and fixed by means of a clamp.
The pole mount adapter is mounted in factory; it is also possible to install it later on the
standard light.
Insertion of the connecting cable E2
Factory-mounted pole mount adapter: The cable is led through the pole mount adapter into
the light.
The cable is sealed by means of a gland M32 x 1.5.
When the pole mount adapter is use the cable gland of the standard light
mounted subsequently: E2
Monitoring module
Function Monitoring and switching module for emergency light systems according to VDE 0108:
The module is used for the monitoring of individual lights and for the control of network and
safety lights.
The module offers the following functions:
• Control of the light (ON / OFF) and function test
E2
• Up to 20 addresses can be set for each electric circuit by means of a coding switch
• The operating mode of the lamp (continuous light, stand-by light or activation by means of a
switch) is freely programmable
• Mixed operation within one circuit is possible
Input voltage (Input between L+ and N-) E2
UN 230 (+ 10 % / - 15 %) V AC, 50 Hz
U DC 175 ... 275 V DC
Control input (between L and N)
E2
UN 230 (+ 10 % / - 15 %) V AC, 50 Hz
Connected power (output P 4 ... 100 W
to light)
Ambient temperature Ta (Module) - 10 ... + 50 °C
E2
Dimensions L x W x H = 95 x 40 x 32 mm

E2

E2

E2
2012-06-19·EK00·III·en Lighting E2/5
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400

Accessories and Spare Parts


Designation Illustration Description Art. no. Weight
kg
Fluorescent lamps Two-pin cap d 26 mm 0.000
Light colour: universal white
04936E00
18 W 1350 Im 108952 0.100

36 W 3350 Im 108951 0.200

58 W 5200 Im 108950 0.220

Bracket for wall for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480
mounting with tube

05460E00

Lamp cover for lamp 18 W 115814 0.800


for lamp 36 W 115817 1.500
05329E00 for lamp 58 W 115820 1.800
Pole mount adapter for the subsequent mounting on lights 18 W and 36 W, 115698 2.100
completely with assembly parts

05500E00

Lamp-holder Lamp holder G13 1 piece 117252 0.025

05696E00

Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025

10809E00

Mounting kit for for the subsequent installation in standard lamps 0.000
through wiring DV 5 with 5 conductors,
2,5 mm2 for max. 16 A; L1, L2, L3, N, PE
for lights 18 W 115806 0.400
05503E00
for lights 36 W 115813 0.400
for lights 58 W 115819 0.440
DV3; screwed terminals 3 x 2.5 mm2, max. 16 A 0.000
L1 + N + PE
for lights 18 W 115802 0.200
for lights 36 W 115810 0.240
for lights 58 W 115816 0.260
Reflectors for later installation; broad deep bowl 0.000
for lights with one lamp 18 W 115694 1.103
05324E00 for lights with one lamp 36 W 115731 2.079
for lights with one lamp 58 W 115757 2.079
for lights with two lamps 18 W 115716 1.105
for lights with two lamps 36 W 115745 2.070
for lights with one lamp 58 W 115767 1.985
Socket key M8 / wrench size 13; 140486 0.126
to open/close the central locking

05321E00

E2/6 Lighting 2012-06-19·EK00·III·en


Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
Accessories and Spare Parts
Designation Illustration Description Art. no. Weight
kg
Adapter plates for use together with metal cable glands; the metal cable 0.000 E2
glands are integrated in the earthing system via adapter
plates
1 x M20 x 1.5 1 piece 115815 0.070
05755E00

1 x M25 x 1.5 1 piece 115818 0.070 E2


1 x NPT 1/2“ 1 piece 115821 0.070

1 x NPT 3/4“ 1 piece 115824 0.070


E2
2 x M20 x 1.5 1 piece 115826 0.060

2 x M25 x 1.5 1 piece 115828 0.060

2 x NPT 1/2“ 1 piece 115829 0.060 E2


Mounting rail for a variable mounting distance 1 pair 115719 0.330

05490E00
E2
Mounting bracket Mounting clamp mounted on a mounting rail for a variable 115777 0.400
mounting distance; 1 pair

05496E00
E2
Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120

05378E00

Wall mounting bra- Material: stainless steel 115713 1.500 E2


cket 90° 1 pair

05555E00

Wall mounting bra-


cket 50°
Material: stainless steel
1 pair
115691 1.200
E2
05556E00

Top rail for ceiling suspension of the lamp 115733 0.280


1 pair E2
05493E00

Pipe clamp with mounting rail for a variable mounting distance; 0.000
Material: stainless steel
1 pair E2
R 11/2“ 115690 1.250
09402E00
R 2“ 115711 1.370
R 11/4“ 115728 1.250
Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020 E2
05703E00

Safety device ÐÐ 203914 0.167


E2
13076E00

E2
2012-06-19·EK00·III·en Lighting E2/7
Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations

04770E00 04771E00

Di- Light Dimen- Light


men- 18 W 36 W 58 W sions in 18 W 36 W
sions mm
in mm L1 724 1334
L1 700 1310 1610 b 221 221
L2 1) 400 800 800 h1 213 213
L3 2) 312 ... 465 670 ... 865 670 ... 865
b 221 221 221
h1 143 143 143
1) fixed mounting distance
2) variable mounting distance

EXLUX 6000 und EXLUX 6400 Standard Light EXLUX 6000 und EXLUX 6400 Side Entry Lamp

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm) - Subject to Alterations

148

03245E00 04775E00 13077E00

Top rail Safety device

03241E00 04776E00 04774E00 04777E00

Mounting rail Wall mounting bracket 50° Wall mounting bracket 90°

E2/8 Lighting 2012-06-19·EK00·III·en


Light Fittings for Fluorescent Lamps
Series EXLUX 6000 / 6400
E2
Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm) - Subject to Alterations

E2

E2

04778E00 04700E00 04701E00 03257E00 E2


Mounting brak- Ring bolt fitted Pipe clamp fitted in the fi- Bracket for wall mounting with pipe section
ket fitted in fi- in the insert xing bracket
xing bracket nuts of the
light
E2
Reflector for Reflector length in
light mm
18 W 554
36 W 1164
58 W 1464 E2
03260E00 03262E00

for lights with one lamp for lights with two lamps
Reflectors

E2
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.

E2

E2

E2

E2

E2

E2

E2
2012-06-19·EK00·III·en Lighting E2/9
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
E2
> As pendant light fitting or
side entry lamp
> Version with 2 lamps:
18 W and 36 W E2
> Central locking
> Weekly functional test
> Light duration test of the
emergency lighting once a year E2

E2

E2
www.stahl.de

E2
Series EXLUX 6008 / 6408 E2

10068E00

E2
The lights of the Series EXLUX 6008 and EXLUX 6408 can be used
as emergency lighting

Class I
E2
ATEX / IECEx (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
EXLUX 6008 x x x EXLUX 6008 x x EXLUX 6008 x x x x x
For use in: For use in: For use in: E2
EXLUX 6408 x*) x*) x*) EXLUX 6408 x EXLUX 6408 x x x x x
For use in: For use in: For use in:
*) only ATEX

E2

E2

E2

E2

WebCode 6008A
E2
2013-06-11·EK00·III·en Lighting E2/1
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408

Selection Table
Version Lamps Battery Lighting hours Order number Weight
kg
6008 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6008/522-9011-7147 8.200
Standard light
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6008/542-9011-7147 10.400
6008 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6008/922-9071-7147 10.800
Side entry lamp
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6008/842-9081-7147 13.000
6408 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6408/522-9011-7147 8.000
Standard light
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6408/542-9011-7147 10.200
(Zone 2, 21, 22)
6408 2 x 18 W 7 Ah 1.5 / 3 h (emergency light) 6408/922-9071-7147 10.600
Side entry lamp
2 x 36 W 7 Ah 1.5 / 3 h (emergency light) 6408/842-9081-7147 12.800
(Zone 2, 21, 22)
Order Number Supplement
Through wiring without 6.08/...-.0..-....
with 6 conductors (18 W only with spring-cage terminal) 6.08/...-.6..-....
Cable glands Standard 1 cable gland M25 x 1.5 and 6.08/...-..1.-....
2 stopping plugs M25 x 1.5

Special Specify non-standard gland parts 6.08/...-..9.-....

Emergency duration with 6.08/...-....-...7


test
without 6.08/...-....-...8
Note:
The continuous operation is set in factory; by removing a jumper and connecting an external switch,
the switchable continuous operation can be activated.
The lights are delivered without fluorescent lamps and assembly parts.
These parts must be ordered separately.

Explosion Protection
Global (IECEx)
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Gas and dust IECEx PTB 07.0053 --
Ex d e mb IIC T4 --
Ex tD A21 IP66 T80°C --
Europe (ATEX)
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Gas PTB 97 ATEX 2032 SNCH 03 ATEX 3519 (Zone 2)
E II 2 G Ex d e mb IIC T4 E II 3 G EEx nA II T4 (Zone 2)
Dust PTB 97 ATEX 2032 SNCH 03 ATEX 3518 (Zone 21)
SNCH 03 ATEX 3519 (Zone 22)
E II 2 D Ex tD A21 IP6. T80°C E II 2 D IP66 T80°C, T90°C (Zones 21, 22)
T80 °C at Ta = + 40 °C
T90 °C at Ta = + 50 °C
Certificates and approvals
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
Certificates IECEx, ATEX, Brazil (UL do Brasil), ATEX, Belarus (GOST-B)
India (PESO), Canada (CSA),
Kazakhstan (GOST-K), Russia (GOST-R),
Ukraine (GOST-U), USA (FM),
Belarus (GOST-B), Serbia (IZP), Corea KGS),
China (CQST)
Other approvals ship approval (GL) --
Further parameters
Marking (CE) C 0158 C 0158

E2/2 Lighting 2013-06-11·EK00·III·en


Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
E2
Technical Data
Electrical data
Rated voltage 220 ... 254 V, 50 / 60 Hz
110 ... 127 V, 50 / 60 Hz available on request
Disconnection of the light When opening the light
Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast E2
are disconnected; contacts of the switching element are NC contacts, they can only switched on
again when the lamp cover and the central locking system are closed.
In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power
supply.
Luminous characteristics
Lamps 2 x 18 W; 2 x 36 W E2
Measures for light Standard: deep bowl, internal reflector of the lights are painted in white colour.
guidance Colour: signal white RAL 9003; lateral dazzle limitation in the lamp cover.
Special feature: Additional reflector (can be easily mounted), broad deep bowl, polished
aluminium
Ambient conditions
Version 6008, Zones 1, 21, 22 6408, Zones 2, 21, 22
E2
Ambient temperature - 30 ... + 50 °C Standard operation: - 20 ... + 50 °C
- 5 ... + 40 °C operationable Battery operation:
- 5 ... + 50 °C charging,
- 20 ... + 50 °C discharging
Mechanical data E2
Degree of protection IP66 / IP65 (IP64 when using the breather 8162)
Protection class I (with internal PE connection)
Material
Enclosure material Polyester, glass fibre reinforced, colour: white, similar to RAL 9010
Lamp cover Polycarbonate; as an option an aromatic-resistant paint can be used E2
Gasket Polyurethane foam gasket in the lamp cover
Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13,
hinged lamp cover
Mounting / Installation
Cable entry Standard light
Standard: Connection side: 1 screw connection M25 x 1.5 and 1 stopping plug M25 x 1.5;
E2
opposite side: 1 stopping plug M25 x 1.5
Special: M20 in moulded material or metal
Possible holes: 2 x NPT 1/2" or 1 x NPT 3/4" for side entry lamp
Side entry lamp
Factory-mounted pole mount adapter: E2
18 W: Use the cable gland of the standard lamp.
36 W: The cable is inserted into the light through the pole mount adapter.
1 x M25 x 1.5 stopping plugs 8290 (enclosed in the delivery)
1 x M25 x 1.5 breathing gland (enclosed in the delivery)
The cable is sealed by means of a gland M32 x 1.5.
If the pole mount adapter is subsequently mounted (possible for lamps 18 W and 36 W): E2
Use the cable gland of the standard light
Connection Standard: Terminal block with cover designation: L1; N; PE; L' (L' = switched phase);
terminal capacity: max. 2 x 6 mm2 (singe-wire); 2 x 4 mm2 (fine-stranded wire)
Special Terminal block with additional terminals for through wiring,
6 poles (terminal designation: L1 + L2 + L3 + N + PE, L') E2
Through wiring Lights are available with internal through wiring, 6 conductors at 18 W are only possible in
connection with a spring cage terminal.
The through wiring kit is retrofittable; cross section 2.5 mm2 for max. 16 A

E2

E2

E2

E2
2013-06-11·EK00·III·en Lighting E2/3
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408

Technical Data
Assembly Looping of the Standard light
cables On the connection side, there are two possibilities M25 x 1.5 for the
looping of the connecting line
(entry and exit on one side), also possible with lights subsequently
fitted with pole mount adapter.
Through wiring Standard light Lights are available with internal through wiring.
Entry and exit holes for connecting cables are positioned on the
opposite sides. Terminals: see Technical data.
Wiring cross-section 2.5 mm2 for max. 16 A
Assembly Standard light
Standard: 2 x M8 insert nuts in the enclosure
Special: Mounting grooves in the enclosure for the use of fastening
and ceiling rails for variable light installation
(variable mounting distances for lights 18 W: 312 ... 465 mm;
36 W: 670 ... 865 mm)
The pole mount adapter is mounted in factory and can be retrofitted
on the standard light
Side entry lamp
The light is mounted on a tube adapter with the diameter 42 mm
and fixed by means of a clamp.
The pole mount adapter is mounted in factory; it is also possible to
install it later on the standard light.
Insertion of the connecting cable:
If a factory-mounted pole mount adapter is used:
The cable is lead through the pole mount adapter into the light.
The cable is sealed by means of a gland M32 x 1.5.
(only possible for 36 W lights)
If a retrofitted pole mount adapter is used:
use the gland of the standard light

Emergency light electronics


Operating modes Continuous operation, continuous operation with emergency light blocking and stand-by switching
Battery charge Intelligent battery management, controlled microprocessor (charging time max. 14 h) total
discharge protection to avoid a pole reversal
Emergency light mode During emergency light operation, only one lamp is used. This results in a reduced lighting power
(see emergency light service time)
Emergency light service Battery capacity Emergency light Emergency lighting power
time service time Lights 18 W Lights 36 W
7 Ah 1.5 h 100 % 60 %
3h 60 % 30 %
Switchover voltage from mains to battery operation for U < 0.74 x UN
from battery to mains operation for U > 0.80 x UN
Test functions
Functional test The emergency light function is checked once a week
First test takes place 1 hour after putting into operation
For the first test, both lamps are switched on for 1 minute and the battery is charged with the rated
current.
Battery errors and lamp faults are detected and indicated via the LED.
Light duration test of Automatic light duration test function integrated in the light;
the emergency lighting Activation of the function: remove the jumper between the terminals 9 and 12.
After having removed the bridge between the terminals 9 and 12, the test function is activated as
soon as the light is connected to the mains and repeated automatically after time has elapsed.
Test of the battery capacity in time intervals of 6 months; operation of the device in the emergency
light mode during 2/3 of rated operation time. If the light is switched off by the discharge protection
before the time has elapsed, the battery cannot be used for the emergency mode.
The red LED indicates the error.

E2/4 Lighting 2013-06-11·EK00·III·en


Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
E2
Technical Data
Function indicators 1 LED red and 1 LED green,
located in the reflector sheet, can be seen from the outside through the lamp cover
LED Indication Function
Green On
Blinking
Light is OK; charging current is supplied
Light is OK; function test and operating time
E2
test are active
Red On Battery error; connection to the battery is
interrupted or battery is completely discharged
Blinking Battery error; battery capacity is too low
Flashing Lamp fault; lamp defective or lamp at the end E2
of service life
Green/ Blinking Emergency light function is blocked by an
Red external switch
Blinking 1 s ON

Flashing
1 s OFF
0.25 s ON E2
1.75 s OFF
Operating modes On delivery, the light is wired for a continuous operation;
if the jumper between the terminals 9 and 10 of the emergency light electronics is removed and an
external switch F is connected, the continuous mode with switchable emergency light is activated.
Terminals emergency E2
Terminals emergency lighting electronics
lighting electronics

Jumper
External Maintained operation with E2
Maintained operation switch F switchable emergency lighting
08711E01 08712E01

Function description
Continuous operation
In case of a power failure of the general lighting system, the battery will supply the light with power
independently of the light switch position. E2
Continuous operation with switchable emergency light blocking
in case of a power failure for the general lighting system, the light is only switched to the emergency
light mode if the external switch F is closed. The external switch switches the emergency light
automatically to "Ready" or "Not ready" depending, for example, on the operating times of the
system; the external switch is equipped with a potential-free contact.
E2
A maximum number of 30 lights can be connected to each external switch with series connection
or 50 lights in a star-like arrangement. The cable length must not exceed 500 m.
Cross section of the cable: at least 1.5 mm
Battery set
Version
Operating voltage
Gas-tight NiCd battery
6V
E2
Capacity 7 Ah
Replacing the battery set When the battery enclosure is opened, the battery set is de-energised;
the battery set can be removed from the enclosure after disconnection of the plug-in contacts

E2

E2

E2

E2

E2
2013-06-11·EK00·III·en Lighting E2/5
Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408

Accessories and Spare Parts


Designation Illustration Description Art. no. Weight
kg
Fluorescent lamps 18 W 1350 Im 108952 0.100

04936E00
36 W 3350 Im 108951 0.200

Bracket for wall for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480
mounting with tube

05460E00

Lamp cover for lamp 18 W 115814 0.800


for lamp 36 W 115817 1.500
05329E00

Pole mount adapter for the subsequent mounting on lights 18 W and 36 W, 115698 2.100
completely with assembly parts

05500E00

Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025

10809E00

Switching element 8082/1-2-00, 1 NO contact 132640 0.030

13556E00

Reflectors for lights with two lamps 18 W 115716 1.105


for lights with two lamps 36 W 115745 2.070
05324E00

Socket key M8 / wrench size 13; 140486 0.126


to open/close the central locking

05321E00

Adapter plates 1 x M20 x 1.5 1 piece 115815 0.070

1 x M25 x 1.5 1 piece 115818 0.070

1 x NPT 1/2“ 1 piece 115821 0.070


05755E00

1 x NPT 3/4“ 1 piece 115824 0.070

2 x M20 x 1.5 1 piece 115826 0.060

2 x M25 x 1.5 1 piece 115828 0.060

2 x NPT 1/2“ 1 piece 115829 0.060

Battery set Gas-tight NiCd battery; 7 Ah / 6 V 118013 1.000

05567E00

Wall mounting Material: stainless steel 115713 1.500


bracket 90° 1 pair

05555E00

E2/6 Lighting 2013-06-11·EK00·III·en


Emergency Light Fitting for Fluorescent Lamps
Series EXLUX 6008 / 6408
E2
Accessories and Spare Parts
Designation Illustration Description Art. no. Weight
kg
Wall mounting
bracket 50°
Material: stainless steel
1 pair
115691 1.200
E2
05556E00

Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120
E2
05378E00

Mounting rail for a variable mounting distance 1 pair 115719 0.330

E2
05490E00

Mounting bracket Mounting clamp mounted on a mounting rail for a variable 115777 0.400
mounting distance; 1 pair

05496E00
E2
Top rail for ceiling suspension of the lamp 115733 0.280
1 pair

05493E00 E2
Pipe clamp R 11/2“ 115690 1.250
R 2“ 115711 1.370
R 11/4“ 115728 1.250
09402E00 with mounting rail for a variable mounting distance;
Material: stainless steel
E2
1 pair
Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020

05703E00 E2
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations

E2

04772E00 04773E00
E2
Dimensions Light Dimensions Light
in mm 18 W 36 W in mm 18 W 36 W
L1 782 1392 L 806 1416
L2 1) 400 800 E2
L3 2) 312 ... 465 670 ... 865
1) fixed mounting distance
2) variable mounting distance

EXLUX 6008 und EXLUX 6408 Standard Light EXLUX 6008 und EXLUX 6408 Side Entry Lamp E2
We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without
notice.The illustrations cannot be considered binding.

E2

E2
2013-06-11·EK00·III·en Lighting E2/7

You might also like