Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

02

SCHEDULE OF BEAMS

B1 230 380 3 12 - - 3 12 - - 1 12 8 100 8 100


REBARING OF BEAM ON THIS SIDE BR1 230 380 3 12 - - 5 12 - - 1 12 8 75 8 75
MIN. 200MM INSIDE USING REBARING B2 150 380 2 12 - - 2 12 - - - - 8 100 8 100
REBARING OF BEAM ON CHEMICAL (DOWELS TO BE LEFT MIN. NOTE : ALL BEAM MIN. REBARING INTO EXISTING MEMBER 200MM.
THIS SIDE 200MM INSIDE 1000MM & TO BE LAPPED WITH NEW
USING REBARING CHEMICAL BEAM BARS
(DOWELS TO BE LEFT MIN.
1000MM & TO BE LAPPED SCHEDULE OF SLAB
WITH NEW BEAM BARS BOTTOM STEEL TOP STEEL EXTRA TOP STEEL
SLAB SLAB

B1
Y REMARKS
BR1 X MKD THICKNESS MAIN SPAN OTHER SPAN MAIN SPAN OTHER SPAN MAIN SPAN OTHER SPAN

BEAM TOP AT S1 110 #08@125 C/C #08@125 C/C #08@125 C/C #08@125 C/C -- -- PLAIN DOUBLE MESH SLAB
B2

Z REGULAR SLAB
Y
TOP LEVEL S2 110 #08@125 C/C #08@125 C/C #08@125 C/C #08@125 C/C -- -- PLAIN DOUBLE MESH SLAB
BR1 EXISTING NOTE : REFER SECTIONAL DETAILS ACCORDING TO SLAB
REBARING OF BEAM ON
THIS SIDE 200MM INSIDE
STRUCTURE REBARING OF BEAM
ON THIS SIDE
USING REBARING CHEMICAL MIN. 200MM INSIDE USING
(DOWELS TO BE LEFT MIN. REBARING CHEMICAL NEW BEAM "B1"
1000MM & TO BE LAPPED (DOWELS TO BE LEFT MIN. DOWELS 8MM @ 6" C/C
(BEAM TOP AT SUNK TOP)
STEEL BOTHWAYS
WITH NEW BEAM BARS 1000MM & TO BE LAPPED AT BOTTOM FACE STAGGERED STEEL BOTHWAYS AT
DOWELS 8MM @ 8" C/C USE REBARING CHECMICAL
WITH NEW BEAM BARS 8@125 C/C BOTTOM FACE, 8@125 C/C
STAGGERED REBARING INSIDE BY 6"

110 EXISTING SUNK SLAB 110


SUNK TOP LEVEL
STEEL BOTHWAYS
AT TOP FACE 150 150
EXISTING EXISTING
BEAM B2 8@125 C/C STEEL BOTHWAYS AT TOP FACE
RCC BEAM RCC BEAM 8@125 C/C
PROPOSED

REGULAR SLAB TOP LEVEL


BRACKET
PROPOSED

STRUCTURAL LAYOUT AT SECOND SLAB LEVEL TYP. SECTION Y-Z AT REBARING OF SLAB "S2" TYP. SECTION X-Y AT REBARING OF PROPOSED OF SLAB "S1"

IMPORTANT INSTRUCTIONS :
1) GRADE OF CONCRETE = M25
2) GRADE OF STEEL = FE500
3) COVER TO BEAM = 30MM,
4) COVER TO SLAB = 20MM
*** IMP NOTE : BEFORE DOING REBARING AT ANY SURFACE, CHIP OFF EXISTING 5) ALL DIMENSIONS WILL BE AS PER ARCHITECTURAL DRAWING UNLESS OTHERWISE
PLASTER & COLOR FROM THAT EXISTING CONCRETE SURFACE, SPECIFIED.
*** DO MIN. 150MM REBARING BY USING ADHESIVE CHEMICAL & BEFORE DOING 6) ADD SUPPORT TO 2ND SLAB (BELOW EXTENDED PORTION) FROM BELOW UNLESS
CONCRETING APPLY RBR ADHESIVE CHEMICAL OVER THE SURFACE , BEFORE UNTIL ABOVE SLAB IS COMPLETED.
LAYING NEW CONCRETE. 7) EXISTING STRUCTURAL STABILITY WILL NOT BE OUR RESPONSIBILITY.
8) REFER ARCHITECTURAL DRAWINGS ALONG WITH THIS DRAWING.
9) DISCREPANCY IF ANY SHALL BE DISCUSSED WITH STRUCTURAL ENGINEER.

TYPICAL RING HOOK