Professional Documents
Culture Documents
Zod Security Catalouge
Zod Security Catalouge
toCHOOSE
ZOD
Extinguishers Department
2
ExtinguishErs DEpartmEnt
Fast
Service
Delivery
within
Reasons
to
1 week
CHOOSE How to
ZOD Extinguish
a Fire?!
Ask for your FREE “How-
to-use-an-extinguisher”
stickers and/or get
special
package
Competitive for the
Fire
prices Training
and Work-
unbeatable shop.
service
ONLINE Expertise
Since 1977
status 3 Years
Workshop Guaranty*
LIVE view
With ZOD, no need
Get access to ZOD
to change your
surveillance cam-
cam
eras and check Certificates dry powder every
year!
your extinguishers
maintenance from &
anywhere!
Track your Fire Memberships
6
Extinguishers
Maintenance on
ZOD website: BSI
tracking.zodsecurity.com
ED
Chemical-Proof
RE
GI
STER
& Perforated
Stickers
To insure Expiry Date and
Next Maintenance data re-
main intact and readable in
all conditions...
Indestructible
Dry Powder
in conformity with
EN3
Cylinder
8 11 14 16 18.5 18.5 25 35 31
Diameter (cm)
Total Weight
1.8 3.2 5.75 8.75 12.75 16.6 8.35 16.75 81.3
(Kg)
Hose Length w/
- - - 50.5 55 64 - - 500
nozzle (cm)
Hose Diameter
- - - 1.7 1.7 1.7 - - 2.7
(cm)
Working
Pressure @ 20°C 18 18 18 18 18 18 18 18 18
(bar)
Test Pressure
27 27 27 27 27 27 27 27 27
(bar)
8A 13A 21A 34A 34A 55A 43A 43A 34A
Fire Rating 34B 55B 113B 183B 183B 233B 233B 233B 65B
C C C C C C C C C
Temperature -30 -30 -30 -30 -30 -30 -30 -30 -30
Range (°C) +60 +60 +60 +60 +60 +60 +60 +60 +60
Covering
- - - - - - 23 23 -
area@3m height
Powder
Concentration 82 82 70 70 70 70 82 82 70
(%)
Discharge Time
8 11 12 16 16 22 - - 45
(S)
Body Burst
- - - - - - 35+ 35+ 89+
Pressure (Bar)
carBon
dIoxIde
CO2
cylinder diameter
12 13.5 13.5 16 18.5
(cm)
Working Pressure
55 55 55 14 14
@ 20°c (bar)
21A 21A
Fire rating 34BC 55BC 55BC
183B 183B
t
temperature range -30 -30 -30 +5 +5
(°C) +60 +60 +60 +555 +555
extinguishing
CO2 CO2 CO2 3%AFFF 3%AFFF
agent
Body Burst
480+ 480+ 480+ - -
Pressure (Bar)
cylinder Wall
4 5 5 - -
thickness (mm)
extInguIshers maIntenance
accessorIes
Hoses
Valves
Horn
Strap
• Class A: SOLIDS
such as paper, wood, plastic
etc...
• Class B: FLAMMABLE
LIQUIDS such as paraffin,
petrol, oil etc
• Class C: FLAMMABLE
GASES such as propane,
butane, methane etc
CO2 extinguishers: the 5kg CO2 extinguisher is to be Stand-alone Smoke Fire blanket: Stored
used in a ventilated space on electronic equipment; Detector: battery operated, in kitchens, in an
they cover to be placed near gas accessible place near
sources whereas in kitchen the cooking fire,
• Class E: Fires involving ELECTRICAL or near heating equipment. covers Cooking OIL &
APPARATUS FAT etc
dry Powder
extinguishers :
extinguisher
tinguisher 1 kg: extinguisher
tinguisher 2 kg:
Volume 1.25L Volume 2.5L
Out-diameter Φ 85 mm Out-diameter Φ 110 mm
Height 265 mm Height 380 mm
1. suBstance
Trade name: ABC 40 3. PhysIcal and chemIcal ProPertIes
Use of the substance/preparation: Structure: Solid and dust
A, B, C type powder fire extinguishing fires. Color: yellow
Manufacturer:RÜHLE FEUERLÖSCHMITTEL GMBH; pH: 4 to 4.5 (10% water repellent) DIN ISO 787/9
Hugenottenstr. 105 Melting point:> 200 ° C approximately
61381 Friedrichsdorf / germany Density: at 20 ° C for about 1.8 g / ml
extinguisher
tinguisher 1 kg:
Volume 1.5L
Out-diameter Φ 94 mm
Height 230 mm
extinguisher
tinguisher 2 kg:
Volume 2.28L
Out-diameter Φ 114 mm
Height 245 mm
certIFIcatIons BSI
ED
ul listed extinguishers can be provided upon request
RE
GI
STER
from noha
en3-7 laBo
t pe
ty Certifications Fire ratings
test rePort nr
POWDER 40% EN 615
EN 10479
ABC DRY CHEMICAL STANDARTFM 589985
POWDER 70% EN 615
EN 10480
ABC DRY CHEMICAL STANDARTFM 589986
All ZOD Powder Extinguishers are pressurized with 99.9% Dry Nitrogen
Propeller (Azote45)
8
Extinguishers Department
Test Reports
Dry Powder
2. COMPOSITION 2. COMPOSITION
Chemical characterization: Chemical characterization:
MAP (Mono Ammonium Phosphate) based Powder 82% Sodium Bicarbonate
70% Mono Ammonium Phosphate 15% Calcium Carbonate
25% Ammonium Sulfate
5% mica powder 70% ABCD
3% mica powder
& Cabinet
TEST ITEM STANDARD GB15308-2006 RESULT
TIME OF
≤5 3.5
SLOW ERADICATE /min
DISCHARGE TIME OF BURN
≥15 15.5
RESISTANCE/min
QUICK TIME OF
≤3 2.6
DISCHARGE ERADICATE /min
REMARK:
9
ExtinguishErs DEpartmEnt
maIntenance
2
Process
1
As per NFPA
& LIBNOR And replaced by extinguishers
Standards on consignment basis during
the maintenance time process
3
Extinguishers
are retrieved
from the client
All extinguishers
9
are dismantled in
ZOD workshop
4
Cylinders and
accessories are
checked and
Stickers are installed changed
showing weight, date of upon need
filling , next maintenance, For all Powder
5
and expiry date
Extinguishers
8 6
Then they are
re-painted
Extinguishers
are re-mantled
Powder is changed
7
upon need
Extinguishers are
placed in a water
tank to make sure no
pressure is leaking
For all CO2 Extinguishers: - fiber optic inspection of the interior of the cylinder
Testing, filling & quality control flow for damage & corrosion
- hydrostatic pressure test at 1.5 the cylinder’s Test-
Extinguishers are retrieved from the client and replaced ing Pressure using the latest equipment
by extinguishers on consignment basis during the main- • If the Cylinder passes all the tests, it’s sent to
tenance time process, then for each extinguisher: the filling station:
• Before filling: 1. The cylinder is weighted empty
1. check physical damage 2. The cylinder gets filled with Liquid CO2 to its cor-
2. check the testing date of the cylinder respondent capacity (6kg, 9kg…)
3. check if the cylinder is compliant with the list of 3. The cylinder is re-weighted to make sure it’s full
unusable cylinders (0.66 x Volume in L = max capacity in KG)
4. check if the valve is functional and compliant with 4. The valve is checked with a specific material to
the list of usable valves make sure it sealed and there’s no leakage
5. then, if required, the cylinder is submitted to a 5. Then there’s the Pressure Test
series of inspections: 6. Then it’s sealed and sent to the customer