Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Reasons

toCHOOSE
ZOD

Because You Are Priceless

Extinguishers Department
2
ExtinguishErs DEpartmEnt

Fast
Service
Delivery
within

Reasons
to
1 week

CHOOSE How to
ZOD Extinguish
a Fire?!
Ask for your FREE “How-
to-use-an-extinguisher”
stickers and/or get
special
package
Competitive for the
Fire
prices Training
and Work-
unbeatable shop.
service

ONLINE Expertise
Since 1977
status 3 Years
Workshop Guaranty*
LIVE view
With ZOD, no need
Get access to ZOD
to change your
surveillance cam-
cam
eras and check Certificates dry powder every
year!
your extinguishers
maintenance from &
anywhere!
Track your Fire Memberships

6
Extinguishers
Maintenance on
ZOD website: BSI
tracking.zodsecurity.com
ED

Chemical-Proof
RE

GI
STER

& Perforated
Stickers
To insure Expiry Date and
Next Maintenance data re-
main intact and readable in
all conditions...

Indestructible

*for Dry Powder Extinguishers


3
Extinguishers Department

Dry Powder
in conformity with

EN3

6Kg 12Kg 50Kg *


Description 1Kg 2Kg 3.5Kg 6Kg 9Kg 12Kg
AUTO AUTO wheeled
Overall Height
31.5 36.5 44.5 49.5 58 63 25 29 110
(cm)

Height (cm) 26.5 31.5 36.5 41.5 50.5 55.5 20 24 90

Cylinder
8 11 14 16 18.5 18.5 25 35 31
Diameter (cm)
Total Weight
1.8 3.2 5.75 8.75 12.75 16.6 8.35 16.75 81.3
(Kg)
Hose Length w/
- - - 50.5 55 64 - - 500
nozzle (cm)
Hose Diameter
- - - 1.7 1.7 1.7 - - 2.7
(cm)
Working
Pressure @ 20°C 18 18 18 18 18 18 18 18 18
(bar)
Test Pressure
27 27 27 27 27 27 27 27 27
(bar)
8A 13A 21A 34A 34A 55A 43A 43A 34A
Fire Rating 34B 55B 113B 183B 183B 233B 233B 233B 65B
C C C C C C C C C
Temperature -30 -30 -30 -30 -30 -30 -30 -30 -30
Range (°C) +60 +60 +60 +60 +60 +60 +60 +60 +60
Covering
- - - - - - 23 23 -
area@3m height
Powder
Concentration 82 82 70 70 70 70 82 82 70
(%)
Discharge Time
8 11 12 16 16 22 - - 45
(S)
Body Burst
- - - - - - 35+ 35+ 89+
Pressure (Bar)

Water Silver coated


Extinguishers extinguishers
Old but Gold Need a stylish look?
Although rarely requested, water extin- You can request a silver color, nickel coat-
guishers are also ready for supply upon ing for your extinguishers - Security can
request. also rime with style!
*50Kg cylinder wall Thickness is 2.32mm
Foam

carBon
dIoxIde
CO2

description 2.3Kg co2 5Kg co2 6Kg co2 6l Foam 9l Foam

overall height (cm) 53.5 75 85 50 58

height (cm) 43 65 76 41.5 50

cylinder diameter
12 13.5 13.5 16 18.5
(cm)

total Weight (Kg) 6.75 13.85 15.85 8.75 12.85

hose length with


- 103 103 52 72
nozzle (cm)

hose diameter (cm) - 1.7 1.7 1.7 1.7

Working Pressure
55 55 55 14 14
@ 20°c (bar)

test Pressure (bar) 250 250 250 27 27

21A 21A
Fire rating 34BC 55BC 55BC
183B 183B
t
temperature range -30 -30 -30 +5 +5
(°C) +60 +60 +60 +555 +555
extinguishing
CO2 CO2 CO2 3%AFFF 3%AFFF
agent

discharge time (S) 8 13 13 26 28

Body Burst
480+ 480+ 480+ - -
Pressure (Bar)
cylinder Wall
4 5 5 - -
thickness (mm)

extInguIshers maIntenance
accessorIes
Hoses

Valves

Horn
Strap

Heat Bulb Manometer/Pressure Gage


5
ExtinguishErs DEpartmEnt

What you should know:


What do you need in a living environment?
Dry Powder extinguishers:
As per NFPA standard, each 100sqm needs at least
4 Dry powder extinguishers of 3.5kg each

• Class A: SOLIDS
such as paper, wood, plastic
etc...

• Class B: FLAMMABLE
LIQUIDS such as paraffin,
petrol, oil etc

• Class C: FLAMMABLE
GASES such as propane,
butane, methane etc

CO2 extinguishers: the 5kg CO2 extinguisher is to be Stand-alone Smoke Fire blanket: Stored
used in a ventilated space on electronic equipment; Detector: battery operated, in kitchens, in an
they cover to be placed near gas accessible place near
sources whereas in kitchen the cooking fire,
• Class E: Fires involving ELECTRICAL or near heating equipment. covers Cooking OIL &
APPARATUS FAT etc

What do you need in a transportation vehicle?

dry Powder
extinguishers :

1 kg for a 2 Kg (or 3.5Kg) for a 6 kg + for a truck


small car 4 wheeled big car / depending on size and
mini-van nature of transportation

FIrst aId measures


In case of contact with eyes: Gently wash the eye
with water for at least 15 minutes. Consult an
ophthalmologist if irritation persists.
avaIlaBle 1 and 2 Kg
extInguIshers

ZOD 82% extinguishers


% 82 BC Class Powder *

Working Pressure 18 Bar


Test Pressure 27 Bar
Material Quality FePO4
Material Thickness 1.5mm
Working Temperature Range: -30°~ +60°C

extinguisher
tinguisher 1 kg: extinguisher
tinguisher 2 kg:
Volume 1.25L Volume 2.5L
Out-diameter Φ 85 mm Out-diameter Φ 110 mm
Height 265 mm Height 380 mm

*for more info on powder check page 9

ZOD CE 40% extinguishers


% 40 MAP ABC Class Rühl German Powder TS862-EN3-7+A1
EN3 Legislation No. Pursuant 1907/2006 (REACH)

1. suBstance
Trade name: ABC 40 3. PhysIcal and chemIcal ProPertIes
Use of the substance/preparation: Structure: Solid and dust
A, B, C type powder fire extinguishing fires. Color: yellow
Manufacturer:RÜHLE FEUERLÖSCHMITTEL GMBH; pH: 4 to 4.5 (10% water repellent) DIN ISO 787/9
Hugenottenstr. 105 Melting point:> 200 ° C approximately
61381 Friedrichsdorf / germany Density: at 20 ° C for about 1.8 g / ml

2. comPosItIon 4. toxIcologIcal InFormatIon


Chemical characterization: LD-50 Rat (oral)> 2000 mg / kg
Ammonium salts and mineral additives based fire
extinguishing powder. 5. regulatory InFormatIon
Do not contain hazardous components as specified in National regulations (Germany):
the German regulations. Water hazard class: 1 (less pollutant)
Basic Components:
Mono Ammonium Phosphate (MAP)
Ammonium sulfate
Working Pressure 18.5 Bar
CAS-No .: 7722-76-1 ;
7738-20-2 Test Pressure 27 Bar
EINECS-No .: 231-764-5 ; Material Quality FePO4
231-984-1 Material Thickness 1.5mm
Product Standard EN 3.1-3.8
Working Temperature Range: -20°~ +60°C

extinguisher
tinguisher 1 kg:
Volume 1.5L
Out-diameter Φ 94 mm
Height 230 mm
extinguisher
tinguisher 2 kg:
Volume 2.28L
Out-diameter Φ 114 mm
Height 245 mm
certIFIcatIons BSI

ED
ul listed extinguishers can be provided upon request

RE
GI
STER
from noha

en3-7 laBo
t pe
ty Certifications Fire ratings
test rePort nr
POWDER 40% EN 615
EN 10479
ABC DRY CHEMICAL STANDARTFM 589985
POWDER 70% EN 615
EN 10480
ABC DRY CHEMICAL STANDARTFM 589986

1Kg ABC powder EN3-12/281 8A -34 B -C EN 10870

2Kg ABC powder EN3-12/282 13A - 55 B -C EN 10871

6Kg ABC powder EN3-12/283 34A - 183 B -C EN 10872

9Kg ABC powder EN3-12/284 8A - 34 B -C EN 10873

6L Foam EN3-12/286 8A - 113 B EN 10874

9L Foam EN3-12/287 13A - 183 B EN 10875

All ZOD Powder Extinguishers are pressurized with 99.9% Dry Nitrogen
Propeller (Azote45)
8
Extinguishers Department

Test Reports
Dry Powder

% 70 BC Class Powder % 82 BC Class Powder


1. SUBSTANCE 1. SUBSTANCE
Trade name: ABC 70 Trade name: BC 82
Use of the substance/preparation: Use of the substance/preparation:
A, B, C type powder fire extinguishing fires. B, C type powder fire extinguishing fires.

2. COMPOSITION 2. COMPOSITION
Chemical characterization: Chemical characterization:
MAP (Mono Ammonium Phosphate) based Powder 82% Sodium Bicarbonate
70% Mono Ammonium Phosphate 15% Calcium Carbonate
25% Ammonium Sulfate
5% mica powder 70% ABCD
3% mica powder

3. PHYSICAL AND CHEMICAL PROPERTIES


82% BC
3. PHYSICAL AND CHEMICAL
Quality PROPERTIES
Requirement Report Quality
Structure: Solid Requirement Report
and dust
Structure: Solid and dust Color: yellow
Color: yellow for ABC Dry Chemical Powder ° CBC
Density: at 20for forDry Chemical
about 0.98 gPowder
/ ml
Density: at 20 ° C for about 0.98 g / ml

Item Requirement Record Item Requirement Record


% Main content(MAP) % Sodium Bicarbonate
70.0 ± 3.0 72.6 82.0 ± 2.0 82.53

Ammonium Sulfate 20 ± 2.0 22.4 Looseness g/cm 0.95 ± 0.10 0.98


Kg/l Apparent density 0.93 ± 0.07 0.85 Hygroscopic ratio % ≤ 2.0 0.1
Particle 0.250mm - 0.125mm ± 3.0 8.0 Needling Degree mm ≥16.0 20
distribution 0.125mm – 0.063mm ± 6.0 20.0 Repellency S ≤ 5.0 2
0.063mm – 0.040mm ± 6.0 21.0 % > 0.250mm 0 0
Particle 0.250mm - 0.125mm 3.0 ± 3.0 3.0
Colour YELLOW YELLOW
distribution 0.125mm - 0.063mm 6.0 ± 6.0 6.0
Resistance to caking and lumping
No Lumping on Qualified
0.063mm - 0.040mm 16.0 ± 6.0 18
Thc425µ m aieve
Water repellency Qualified Qualified < 0.040mm ≥ 65.0 70
% Moisture content < 0.20 0.07 Cryogenic proof S ≤5.0 0.2
Calcium Carbonate NO NO
XUANCHENG JINDUN FIRE FIGHTING EQUIPMENT CO., LTD. Tested Date XJ/11/05/2015 Verified LSZ 11/05/2015
Conclusion Qualified Conclusion: Qualified
TEST REPORT

Date: Feb 2015 Date: May 2015


FOAM
Product Name: Foam extinguishing agent
(Aqueous Film Forming Foam extinguishing agent)
Type: Zod
Joumana 3%(AFFF -10� ) NO.: 0811SM30810-Q Joumana Zod
Communication Director Brackets, signs
Communication Director

& Cabinet
TEST ITEM STANDARD GB15308-2006 RESULT

FREEZING POINT/� 0-4� -10

Violette Awad PH VALUE 6.0~9.5 8.2 Ask


Violette Awadfor a survey and get your extin-
Extinguishers Coordinator guishers
Extinguishers placed in their right loca-
Coordinator
DIFFUSED QUOTIETY
≥0
2.6 tion, ready for use and visible for an
emergency action!
6.5±20%
VESICANT MULTIPLE 7.1

25% ATTENUANT TIME/min 2.5±20% 3.0

TIME OF
≤5 3.5
SLOW ERADICATE /min
DISCHARGE TIME OF BURN
≥15 15.5
RESISTANCE/min
QUICK TIME OF
≤3 2.6
DISCHARGE ERADICATE /min

REMARK:
9
ExtinguishErs DEpartmEnt

maIntenance

2
Process

1
As per NFPA
& LIBNOR And replaced by extinguishers
Standards on consignment basis during
the maintenance time process

3
Extinguishers
are retrieved
from the client

All extinguishers

9
are dismantled in
ZOD workshop

4
Cylinders and
accessories are
checked and
Stickers are installed changed
showing weight, date of upon need
filling , next maintenance, For all Powder

5
and expiry date
Extinguishers

8 6
Then they are
re-painted
Extinguishers
are re-mantled

Powder is changed

7
upon need

Extinguishers are
placed in a water
tank to make sure no
pressure is leaking

For all CO2 Extinguishers: - fiber optic inspection of the interior of the cylinder
Testing, filling & quality control flow for damage & corrosion
- hydrostatic pressure test at 1.5 the cylinder’s Test-
Extinguishers are retrieved from the client and replaced ing Pressure using the latest equipment
by extinguishers on consignment basis during the main- • If the Cylinder passes all the tests, it’s sent to
tenance time process, then for each extinguisher: the filling station:
• Before filling: 1. The cylinder is weighted empty
1. check physical damage 2. The cylinder gets filled with Liquid CO2 to its cor-
2. check the testing date of the cylinder respondent capacity (6kg, 9kg…)
3. check if the cylinder is compliant with the list of 3. The cylinder is re-weighted to make sure it’s full
unusable cylinders (0.66 x Volume in L = max capacity in KG)
4. check if the valve is functional and compliant with 4. The valve is checked with a specific material to
the list of usable valves make sure it sealed and there’s no leakage
5. then, if required, the cylinder is submitted to a 5. Then there’s the Pressure Test
series of inspections: 6. Then it’s sealed and sent to the customer

G.S.S Center, Dbayeh Highway, Beirut, Lebanon P.O.Box 70-539 Antelias


Tel +961 4 543 666 Sales +961 3 543 666 AfterSales +961 3 360 560
Fax +961 4 543 777 Email zod@zod.com.lb Web www.zodsecurity.com

You might also like