WALL FOOTING
T
L = LENGTH
W
FORMULA: VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length LT (M) 32.00 M
Enter Width W (M) 0.30 M
Enter Thickness T (M) 0.15 M
TOTAL VOLUME OF CONCRETE: 1.44 CU.M.
# OF CEMENT BAGS 13.00 BAGS
VOL. OF SAND CU.M. 0.80 CU.M.
LT = TOTAL LENGTH/PERIMETER VOL. OF 3/4" GRAVEL CU.M. 1.50 CU.M.
W2
FORMULA: VOLUME = H * W1 * W2
H CLASS A CONCRETE MIX
Enter Height L (M) 1.22 M
VOLUME OF CONCRETE FOR EACH COLUME: 0.08 CU.M.
Number of Columns Units 10.00 Units
TOTAL VOLUME OF CONCRETE: 0.76 CU.M.
# OF CEMENT BAGS 7.00 BAGS
VOL. OF SAND CU.M. 0.40 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 0.80 CU.M.
CONCRETE BEAMS
FORMULA: VOLUME = LT * W * D
CLASS A CONCRETE MIX
LT EnterTotal Length LT (M) 5.00 M
Enter Width W (M) 0.20 M
BEAM DIMENSIONS: Enter Depth D (M) 0.30 M
D TOTAL VOLUME OF CONCRETE: 0.30 CU.M.
# OF CEMENT BAGS 3.00 BAGS
VOL. OF SAND CU.M. 0.20 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 0.30 CU.M.
W
CONCRETE STAIRS
RIPRAPING WORKS L
W1
Enter Height H (M) 2.00 M
Enter Width 1 W1 (M) 0.30 M
Enter Width 2 W2 (M) 0.60 M
Enter Length L (M) 20.00 M
spacing
layer
80 1.6 4 Layers 1.720
FOOTING MATTING
Enter Footing Length L (M) 0.60 M
Enter Footing Width W (M) 0.60 M
Enter # of Bars along L # 4.00 Pcs
Enter Number of Bars along W # 4.00 Pcs
L Enter Number of Footing # 10.00 Units
Enter Clear Cover Cc (M) 0.050 M
Note: Standard Clear Cover for footing =0.05m to 0.075m
# of Bars
per Side Net. Length along L 0.50 M
W Net. Length along W 0.50 M
# OF REIN. BARS USED: 8.00 LHS
#16 TIE WIRE USED: 1.30 Kgs
Clear Cover
Tie Bars
Spacing
LT = TOTAL LENGTH/PERIMETER
D1
H
Clear Cover
D2 for columns =
0.40m
1 0.2
Use End Hook: 0.200 M
Total length of each bars should be more than or equal to: 4.20 M
Total Number of Vertical Bars @ 6M: 48.00 LHS
6 Circular Stirrups
Cut Length of each stirrups: 0.90 M
Number of Stirrups per Column: 28.50 M
Total Number of Bars required for stirrups @ 6M : 35.00 LHS
#16 TIE WIRE required: 7.80 Kgs
Spiral Stirrups
Cut Length of each stirrups: 0.70 M
Number of Stirrup Loops per Column: 28.50 M
Total Number of Bars required for stirrups @ 6M : 30.00 LHS
#16 TIE WIRE required: 7.80 Kgs
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY
L = Span
L/4
0.15L
Column
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
0.15 L
0.15 L
Column
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 4.00 PCS
BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 3.764 0.474
12.500 3.062 0.316
15.000 2.584 0.228
17.500 2.232 0.168
20.000 1.980 0.132
22.200 1.786 0.110
25.000 1.627 0.089
BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
CONCRETE STAIRS
Enter Riser Height RH (M) 0.20 M
TR Enter Tread Run TR (M) 0.30 M
W Enter Stair Width W (M) 1.00 M
Enter # of Steps N 10.00 Steps
RH
Enter Stringer Thickness TS (M) 0.15 M
0.30 0.36 0.66
Enter Spacing (M)
0.30
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.30 12
Enter Stringer Lateral Bar diameter (mm)
TS
16
Enter Spacing (M)
0.30
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.30 12
Enter Stringer Horizontal Bar diameter (mm)
NOTES: DOWELS FOR LATERAL BARS ARE ALREADY INCLUDED IN THE ESTIMATES
FOR STAIRS LANDINGS YOU MAY USE THE SLAB REINFORCEMENT CALCULATOR
CONCRETE CANAL
W2
W1
W1
NUMBER OF BOARD FOOT OF STUDS & NAILING JOIST PER SQUARE METER
SPACING IN CENTIMETER (CENTER TO CENTER)
Lumber size
in inches 30 x 30 30 x 60 40 x 40 40 x 60 60 x 60
1x2 4.103 3.147 3.189 2.686 2.268
2x2 8.198 6.293 6.379 5.373 4.594
2x3 12.284 9.440 9.569 8.060 6.898
2x4 16.414 12.592 12.758 10.746 9.195
L
Enter Length of Wall/Ceilling/Flooring L (M) 9.00 M
Enter Height of Wall/Ceilling/Flooring H (M) 3.00 M
Enter Constant Factor C 6.898
# OF BD.FT OF STUDS & NAILING JOIST USED: BD.FT 186.25 BD.FT.
# OF 1" CWNails Used for Boards (ONE SIDE) KGS 0.6 KGS
# OF 1" CWNails Used for Boards (TWO SIDES) KGS 1.1 KGS
# OF 2 1/2" CWNails Used for Joining the Studs together KGS 1.4 KGS
Eff
ecti
ve
W i dt
Sid h
e l ap
pi n
g
Ls
Span
Projection (Bulada)
Pitch
12
Roof Width
Roof Width
ROOF ACCESSORIES
TILING WORKS
Enter Wall or Floor Area 22.14 SQ.M.
Enter Breakage Allowance (5 - 10%) 5.00 %
Primer for
3. Red Oxide ferrous and 35 to 40
Primer non-ferrous Paint Thinner 3 Hours sq.m.
materials
Rust
preventive
4. Red Lead 30 to 40
primer for Paint Thinner 3 Hours
Primer sq.m.
ferrous
surfaces
For Steel,
6 hrs, allow
5. Epoxy Aluminum, Epoxy 30 to 40
overnight b4
Primer Galvanized Reducer sq.m.
recoating
iron
Exterior &
30 minutes
1. Acrylic Interior 1/2 lts/ 4 lts 30 to 40
allow 6 hrs b4
Latex Paint masonry water sq.m.
recoat
surfaces
Exterior &
2. Acrylic Interior 30 minutes 30 to 40
Semi-Gloss Water allow 6 hrs b4
masonry sq.m.
Latex recoat
surfaces
Exterior &
30 minutes
3. Acrylic Interior 30 to 40
Gloss Latex masonry Water allow 6 hrs b4 sq.m.
surfaces recoat
For furniture,
cabinets,
doors,
4. Latex Hi- windows, 1 Hour. Allow 30 to 40
Gloss Enamel tools, toys, Usse as is 4 hrs before sq.m.
recoating
wrought iron,
& primed
metals
5. Tinting
Acrylic colors water
Colors
ROOF PAINT
6 hrs. allow
2. Interior Interior wood
overnight 25 to 30
semi-Gloss and metal Paint Thinner
before sq.m.
Enamel surfaces recoating
3 hrs. allow
3. Flat wall for interior overnight 40 to 50
wall & Paint Thinner
Enamel before sq.m.
ceilings
recoating
for exterrior
wood and 6 hrs. allow
4. Exterior properly Paint Thinner 48 hrs. before 30 to 35
Gloss paint sq.m.
primed metal recoating
surfaces
VARNISHING
KIND OF PAINT USES THINING DRYING TIME COVERAGE/Gal
for floors,
1. Valspar or sidings 40 to 50
furnitures, Paint Thinner
24 hours
Spar Varnish sq.m.
deck of boats
for interior
new wood 10 minutes.
2. Hi-solid furnitures Lacquer Allow 30 40 to 50
sanding
and fixtures, Thinner minutes sq.m.
sealer cabinet, before recoat
doors, etc.
for interior
new wood
3. Hi-solid furnitures, Lacquer Allow 30 30 to 40
clear gloss door Thinner minutes sq.m.
Lacquer before recoat
panelling and
trim.
for interior
new wood
4. Hi-solid furnitures, Lacquer Allow 30 30 to 40
Semi-gloss cabinets, Thinner minutes sq.m.
Lacquer doors, before recoat
shelves, etc
for furnitures,
6. Water cabinets, Allow 30
white gloss doors, panel Lacquer minutes 30 to 40
Thinner sq.m.
Lacquer and interior before recoat
walls
DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS
B
BY: ENGR. RONALD JOHN R. CAJILLA
SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
COLUMN BEAM
Enter Column Height M 3.00 Enter Beam Length M 3.50
Enter # of Columns Units 10.00 Enter # of Beams Units 6.00
Total Column Height: 30.00 M. Ht. Total Beam Length: 21.00 M. Ht.
FLOORING
Enter Floor Area SQ.M. 80.00