NOTE: REFER TO THE ARCHITECT IN-CHARGE FOR

THE TYPE/DESIGN OF THE LIGHTING FIXTURES

SCHEDULE OF LOAD "DPB-M" SCHEDULE OF LOAD "DPB-1 TYPICAL UP TO DPB-6"


CRKT. CIRCUIT BREAKER PROTECTION CRKT. CIRCUIT BREAKER PROTECTION
DESCRIPTION VOLTS VA SIZE OF CONDUCTOR & CONDUIT DESCRIPTION VOLTS VA SIZE OF CONDUCTOR & CONDUIT
NO. AT AF POLE NO. AT AF POLE
USE 2-3.5mm2 THHN WIRE IN 20mm DIA. USE 2-3.5mm2 THHN WIRE IN 20mm DIA.
1 LIGHTING OUTLET 230 500 15 50 2 1 LIGHTING OUTLET 230 950 15 50 2
PVC PIPE PVC PIPE
SPARE FOR PERIMETER USE 2-3.5mm2 THHN WIRE IN 20mm DIA. USE 2-3.5mm2 THHN WIRE IN 20mm DIA. EL
2 230 1500 15 50 2 2 CONVENIENCE OUTLET 230 1260 20 50 2
FENCE LIGHT PVC PIPE PVC PIPE
1
USE 2-3.5mm2 THHN WIRE IN 20mm DIA. DPB-6
SPARE FOR WATER USE 2-3.5mm2 THHN WIRE IN 20mm DIA. 3 CONVENIENCE OUTLET 230 1080 20 50 2
3 230 1500 20 50 2 PVC PIPE
PUMP/PRESSURE PVC PIPE

TOTAL VA LOAD= 3500 0 USE 2-3.5mm2 THHN WIRE IN 20mm DIA. DPB
4 REFRIGERATOR 230 450 20 50 2
PVC PIPE
USE 2-5.5mm2 THHN WIRE &1-2.0mm2 RANGE
5 RANGE 230 2400 40 50 2
COMPUTATION FOR THE SIZE OF MAIN CIRCUIT BREAKER PROTECTION AND SIZE OF SERVICE WIRE CONDUCTOR Grounding wire IN 25mm DIA. PVC PIPE
PO

@ DF=70% 1 hp split type wall hang USE 2-5.5mm2 THHN WIRE &1-2.0mm2
6 230 1840 20 50 2
ACU Grounding wire IN 25mm DIA. PVC PIPE REF

3500*.75
I= 11.413043 Amp 1 hp split type wall hang USE 2-5.5mm2 THHN WIRE &1-2.0mm2
7 230 1840 20 50 2
230 ACU Grounding wire IN 25mm DIA. PVC PIPE

Icb= 11.4130 1.2500 14.2663 Amp TOTAL VA LOAD= 9820 0

USE 40AT, 50AF, 2pole MAIN CIRCUIT BREAKER PROTECTION.

USE 2-8.0mm² THHN WIRE and 3.5mm² GROUNDING WIRE IN 32mm DIA. ELECTRICAL PVC PIPE COMPUTATION FOR THE SIZE OF MAIN CIRCUIT BREAKER PROTECTION AND SIZE OF SERVICE WIRE CONDUCTOR

@ DF=70%

(9820+ (.25)(2400))*.70
I= 31.713043 Amp
230
Icb= 31.7100 1.2500 39.6375 Amp

USE 60AT, 100AF, 2pole MAIN CIRCUIT BREAKER PROTECTION.

USE 2-8.0mm² THHN WIRE and 3.5mm² GROUNDING WIRE IN 32mm DIA. ELECTRICAL PVC PIPE

COMPUTATION FOR MAIN SERVICE WIRE


TOTAL CURRENT = 11.413+91.71(6) = 201.67 Amp
1. ALL ELECTRICAL INSTALLATION HEREUNDER SHALL CONFORM IN ACCORDANCE WITH THE
Circuit Breaker rating Icb = 201.67 amp *1.25 = 252.10Amp PROVISIONS OF THE LATEST EDITION OF THE FOLLOWING STANDARD CODE AND
ORDINANCES:

USE 2-125.0mm² THHN WIRE and 5.5mm² GROUNDING WIRE IN 63.0mm/2 inches DIA. ELECTRICAL PVC PIPE A. LATEST EDITION OF PHILIPPINE ELECTRICAL CODE PART I (PEC I)
B. FIRE CODE OF THE PHILIPPINES
C. BUILDING CODE OF THE PHILIPPINES
D. EXISTING CITY ORDINANCES OF LOCAL GOVERNMENT

2. THE SIZE OF WIRE OF THE GROUNDING CONDUCTOR AND THE LINE CONDUCTOR MUST BE
THE SAME FOR SAFETY PURPOSES.

COMING FROM 3. SERVICE ENTRANCE SYSTEM SHALL BE 230V, 1Ø, 3W, 60HZ SYSTEM.
S D
TU M C ELECTRIC
M O

A 4. OUTLETS THAT ARE EXPOSED TO DIRECTLY EXPOSED TO WATER


G IT
U Y
EG
O COOPERATIVE 2 MUST BE WEATHER PROOF AND GFCI PROTECTED.
R
L A

AR
AO WIRE, 1 PHASE ,
N 5. PROVIDE GROUNDING SYSTEM TO POWER CIRCUITS, ALL NON-CURRENT CARRYING METAL
L E

230VOLTS , 60 HZ.
V

O PARTS SHALL BE BONDED AND GROUNDED, ALL PANEL BOARDS SHALL HAVE PROVISION FOR
DP I
M O

GROUNDING BUS AND GROUNDING TERMINALS. OBSERVE OUTLET POLARITY.


E

W S
H
3r
dD R 2- 125.0 mm² THHN in
N
S T.

EO E 6. MOUNTING HEIGHT FROM FINISH FLOOR LINE TO CENTER LINE OF DEVICES ARE AS
63.0mmØ PVC DPB-4 DPB-5 DPB-6
N

V FOLLOWS:
IO
S T.

AT

I
EN
ST

EV

Dept. of Agriculture D
AS

EL
G

7-

WIRE GUTTER A. CONVENIENCE OUTLET = 0.3M


E
B

EG

B. SWITCHES = 1.37m
LL
O
A

C. PANEL BOARD = 1.37M


AS

A D
D. ELECTRIC METER = 1.67M
G

O
S

R
R

R
VA

R O

O N E. OVERHEAD SERVICE ENTRANCE = 4.26M


TE CT

S I
FL
A

R
EN O

E F. COUNTER TOP OUTLET = 1.50M


C DD

I V
D T.
AL TE

ANG S
Y

IL
M M M M
IC NI

ILANG 7. NO CHANGE AND MODIFICATION SHALL BE MADE WITHOUT THE DESIGNER WRITTEN
ED U

DPB-3 DPB-2 DPB-1 DPB-M


M AN

CONSENT.
AY
R

AG

DPB-M DPB-1 DPB-2 DPB-3


C
O

8. VERIFY TO THE ARCHITECT OR OWNER REPRESENTATIVES TYPE OF THE LIGHTING FIXTURES


TO BE INSTALLED.
A
M O L A

M M M 9. WIRING METHOD SHALL BE IMC AND PLASTICIZED POLYVINYL CHLORIDE (PVC).


2- 8.0 mm² THHN in
E

DPB-4 DPB-5 PB-6


V

SIT

32mmØ PVC 10. PUT A PULL BOX IF EXCEEDED TO THE MAXIMUM BENDING OF A RACEWAY.
E

IS

U E
A V E N
S T.

TH

M A I N 11. USE OF HIGHER SIZE OF WIRE FOR SERVICE MAINS TO MINIMIZE VOLTAGE DROP.
U E
A V E N 12. ALL CONDUITS MUST BE EMBEDDED ON THE CONCRETE WALLS AND FLOORS, ALL WIRE
M A I N
MUST BE REAMED BEFORE INSTALLATION TO DAMAGE ON IT.

13. THERE SHOULD BE NO MORE THAN THREE CONDUCTORS IN A RACEWAY.

3
A 1
VICINITY MAP 14. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION
OF A DULY LICENSED ELECTRICAL PRACTITIONER

NOTE: SEE SCHEDULE OF LOADS FOR EXACT SIZING OF WIRE AND CONDUIT