Doweled Undoweled Doweled Undoweled
Recommended Design Thickness: 150.00 mm 150.00 mm Maximum Joint Spacing: 2.64 m 2.64 m
Calculated Minimum Thickness: 152.15 mm 152.15 mm
Pavement Structure
SUBBASE
Calculated Composite K-Value of Substructure: 123.3 MPa/m
CONCRETE SUBGRADE
Compressive Strength: 28 MPa Edge Support: Yes CBR: 10 %
Modulus of Elasticity: 27500 MPa Macrofibers in Concrete: No Calculated MRSG Value 65 MPa
Calculated Flexural Strength: 4 MPa
Project Level
TRAFFIC GLOBAL
Spectrum Type: Minor Arterial Reliability: 80 %
Design Life: 30 years % Slabs Cracked at End of Design Life: 20 %
USER DEFINED TRAFFIC
Trucks Per Day: 500 Avg Trucks/Day in Design Lane Over the Design Life: 261
Traffic Growth Rate %: 1 % per year Total Trucks in Design Lane Over the Design Life: 2.858.666
Directional Distribution: 50 %
Design Lane Distribution: 90 %
Design Method
The PCA design methodology from StreetPave, was used to produce these results.