Hit. Kontrol Pilecap

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

No.

Doc :
KANTOR POLSEK Penulangan Pile Cap Rev :

PERHITUNGAN PILE CAP TYPE P1

Pile Cap Type P1 (1 tiang ) Arah X ( 1300x1300x400 mm2)


Data - data

fc' 25 Mpa Type P1


P 100536 kg Jumlah 1 tiang
Selimut beton 50 mm Lx 1300 mm
Ht 400 mm Ly 1300 mm
d 350 mm
bc 1
bklm 500 mm
hklm 500 mm
bo = bklm + 2*0.5*Ht 900 mm
ho = hklm + 2*0.5*Ht 900 mm

Cek Geser Pons

A = 2*(bo+ho)*d
= 2*(900+900)*350 = 1260000 mm2

Vc1 = (1+2/bc) x (fc'0.5 /6) x A


= (1+2/1) x (25^0.5 /6) x 1260000
= 3150000 N ~ 315000 kg

Vc2 = (fc'0.5 /3) x A


= (25^0.5 /3) x 1260000
= 2100000 N ~ 210000 kg

Diambil yang terkecil ---> Vc = 210000 kg


Cek : Vc > P/f
210000 > 167560 (ok)
Berarti dimensi pile cap bisa dipakai.

Penulangan Pile Cap

Data-data
fc' (beton) 25,00 Mpa Ht 400 mm
fy' (baja) 350,00 Mpa b 1300 mm
d' (1) 50 mm

ALTERNATIVE 1
Q pile cap = 1248 kg/m

0,3 m 2P
0,55 m

L1 = 0,30 m 2P = 201072 kg
L= 0,55 m
No. Doc :
KANTOR POLSEK Penulangan Pile Cap Rev :

Mu = 1.2 x ( 2P.L1 - 1/2.Q.L^2)


= 1.2 x (201072x0,3-1/2x1248x0,55^2)
= 72159,41 kgm

Qpile cap = Ht x B x 2400


= 0,4 x 1,3 x 2400 = 1248 kg/m

pmin = = 0,0025
pmaks = 0,75 x (0,85 x 25)/350 x 0,85 x [600/(600+350)]
= 0,0244

Mu = 72159,408 kgm = 721,59 kNm


d = 400 - 50 = 350,00 mm
j = 0,80

Rn = (721,59 x 10^6) = 5,6640 Mpa


(0,8 x 1300 x 350^2)
W = 0,85 { 1 -sqrt[1 - (2,353 x 5,6640)/25]}
= 0,2692
p = 0,2692 x 25/350 = 0,0192 > 0,0025
< 0,0244
ppakai = 0,0192
As = 0,0192 x 1300 x 350 = 8748,73 mm2

mm2 dipakai
As 8748,73 D16 - 150 ( 1.340 mm2 )
As pembagi 1749,75 D16 - 150 ( 1.340 mm2 )