HIGH PERFORMANCE,

NON-COMBUSTIBLE
FACADE CLADDING

TECHNICAL INFORMATION
www.wintecsystems.com.au
CONTENTS
pg 3 About This Guide

pg 3 Introduction
pg 3 • About Alyclad
pg 3 • Key Features

pg 4 Product Specifications
pg 4 • Typical Composition
pg 4 • Dimensions

pg 4 Finish
pg 5 • Coating Technology
pg 5 • Material Data

pg 6 Performance
pg 6 • Fire
pg 6 • Thermal

pg 7 Installation Details
pg 7 • Installation Considerations
pg 7 • Protective Film
pg 7 • Sequence
pg 8 • Typical Details

pg 8 Installation Details

pg 14 Fabrication Detail
pg 14 • Fabrication Considerations

pg 16 Typical Warranty Details


pg 16 • Warranty Considerations
pg 16 • Keeping Your Warranty Fresh

pg 16 Miscellaneous
pg 16 • Manufacturing Quality
pg 17 • Handling and Storage
DISCLAIMER
pg 17 • Sustainability While the information provided relating to Wintec Systems products is
true to the tests and measures available to us, the information provided
in this article is general in nature only and does not constitute project-
specific building, construction or fire-safety advice. Before acting on any
information on this document, you should consider the appropriateness of
the information having regard to your project parameters and requirements.
Wintec products are deemed suitable or compliant after approval from
building and construction professionals associated with specific projects and
developments. If you’d like some further insight about this topic, contact
Wintec on (07) 5535 4477 or email connect@wintecsystems.com.au
We’re here to see how we can help.
ALYCLAD - TECHNICAL INFORMATION

About This Guide


This guide has been developed to effectively assist fabricators and contractors to work with Wintec Systems’ aluminium cladding suite: Alyclad.

Due to the uncontrollable conditions and methods of job scope, as well as the variable skills and judgment of users/installers, and the quality of equipment,
tools, etc; the suggestions and recommendations contained in this manual are provided without warranty.

The information and recommendations contained herein are believed to be correct at time of publishing, September 2020.

Wintec System reserves the right to revise the contents of this guide.

Introduction
ABOUT ALYCLAD

Alyclad is a 3mm non-combustible solid aluminium cassette cladding system, deemed non-combustible cladding solutions;
perfectly suitable for constructions where non-combustible products are required.

Alyclad is a high impact resistant, solid panel which can be fabricated, curved and rolled. The pre-finished large format cladding panels feature
a PVDF coating system well proven for its superior quality, extensive colour range and design integrity.

KEY FEATURES

Alyclad’s versatility is achieved due to the combination of high-quality considerations and industry leading components. It is an ideal product for application in
type A and B developments where non-combustible building materials are critical.

Alyclad is one of the few large format cladding panels that are deemed non-combustible when tested to AS1530.1.

PRODUCT DNA Pre-finished solid aluminium panel

Alyclad uses only the highly recognised paints known for their high durability, providing the optimum
FINISH
resistance to weather and industrial pollution.

FIXING SYSTEM A cassette style concealed fixing system which is the same to fabricate and install as traditional ACPs.

Type A and B constructions where non-combustible materials are required such as mixed-use
APPLICATION
developments, residential construction, and large-scale government infrastructure projects like hospitals.

3
ALYCLAD - TECHNICAL INFORMATION

Product Specifications
TYPICAL COMPOSITION

Alyclad is an 100% aluminium product. The 3mm thick panels weigh in at 8.1 kilograms per square metre, making the product ideal for large infrastructure
developments such as schools and hospitals.

Alyclad is available in a variety of width and length combinations to suit almost any project and custom sizes are also available on request.

Protective film
PVDF coating system
3mm Aluminium

The material is rigid, resistant to blows, breakage and pressure and has high bending, buckling and breaking strengths.

DIMENSIONS

Thickness: 3mm
Weight: 8.1kg/m2

WIDTH LENGTH THICKNESS

2400

1200/1500 3000 3mm

3600

CUSTOM SIZES ARE AVAILABLE, PLEASE SPEAK TO THE WINTEC SYSTEMS TEAM.

*NOTE: may not be available in all finishes.

Finish
COATING TECHNOLOGY

Alyclad uses only the highly recognised PVDF paints known for their high durability. These premium paints provide the ultimate resistance to weather
and industrial pollution on commercial, industrial, infrastructure and residential developments.

More than 50 years of Australian Exposure Testing is continuing to confirm the superior chemical and physical properties of fluoropolymer coatings.

Alyclad has virtually an unlimited colour range with the possibility of matching almost any panel colour, which provides a fully customisable option
to achieve your dream design.

4
ALYCLAD - TECHNICAL INFORMATION

MATERIAL DATA

PROPERTIES UNITS VALUES

Alloy 5052

Temper H32

Standard thickness mm 3

Raw density kg/m3 2680

Indicative minimum radius mm 4.5

Tensile strength MPa 216

0.2% Proof stress MPa 169

Elongation % 13

Linear thermal expansion 2.38mm at 100 temperature difference


0

Hardness Brinell 60

Melting range c
o
607-650

Modulus of elasticity - Tension GPa 69.3 @ 200c

Modulus of elasticity - Torsion GPa 25.9 @ 200c

Modulus of elasticity - Compression GPa 70.7 @ 200c

Electrical resistivity micro-ohm.m 70.7 @ 200c

Electrical conductivity - Equal volume MS/m 20 @ 200c

Electrical conductivity - Equal weight MS/m 67 @ 200c

Sound absorbtion factor Noise Reduction Co-efficient 0.05

Sound reflection % 95

Test Standard Result


AS1530.1 Non-combustible
TEST REPORT NUMBER: RTF200074

NON-COMBUSTIBLE OUTSTANDING DURABILITY


15 YEAR WARRANTY ABRASIVE RESISTANT
HIGH QUALITY MARINE GRADE NO VISIBLE EXTERNAL JOINTS
SUSTAINABLE WEATHER PROOF
100% RECYCLABLE AS1530.1 CERTIFIED
5
ALYCLAD - TECHNICAL INFORMATION

Performance
FIRE

In today’s architecture, it is the technical details as well as the appearance that count; such as sustainability, thermal insulation and fire protection.

Visually, Alyclad is like traditional composite panel, however what makes it different is the fact that it is constructed from 100% aluminium,
rather than combustible material such as polyethylene and fire rated mineral. This makes Alyclad an ideal product for all applications where
non-combustible panels are required, such as high-rise buildings, schools or hospitals.

As with all building products, the use of Alyclad must be authorised by the regulatory body. The Fire Resistance standards achieved with standard Alyclad
are as follows:

TEST STANDARD RESULT

AS1530.1 NON-COMBUSTIBLE

TEST REPORT NUMBER - RTF200074 - TEST DATE 5 MARCH 2020

THERMAL
THERMAL INSULATING PROPERTIES

THERMAL RESISTANCE FROM -500C to +800C

TEST STANDARD THERMAL RESISTANCE 1A M2.K/W HEAT TRANSMISSION COEFFICIENT W/(M2.K)

Panel Thickness (mm) Thermal Resistance 1A m2.K/W Heat Transmission Coefficient W/(m2.K)

3 0.0069 5.65

AVERAGE EXPANSION

MATERIAL EXPANSION COEFFICIENT (X10 -6/0C) ELONGATION PER 1000MM T = 500C

Alyclad 23.8 1.2mm

Aluminium 23.8 1.2mm

Zinc 26.7 1.3mm

Steel 12.2 0.6mm

Concrete 12 0.6mm

6
ALYCLAD - TECHNICAL INFORMATION

Installation Details
INSTALLATION CONSIDERATIONS

• All sheets should be installed in the same direction as marked on the protective film to prevent possible finish variation.

• As minor colour variation can occur between production lots, it is recommended to place total requirement for a project in one order
to ensure colour consistency.

• Where aluminium materials come in contact with dissimilar metals, a proper insulator or isolation tape should be applied to insulate
between dissimilar materials in order to avoid corrosive and electrolytic action.

• For Cassette Fix, the returns between panel joints should not be caulked before film is removed.

• Please ensure Alyclad is used as part of a compliant wall system, with all components complying with the Deemed-to-Satisfy provisions
of the relevant NCC, or approved as part of a performance solution. Consult with a professional to get their expert opinion.

PROTECTIVE FILM

• Make sure no damage will occur to the panel following removal of protective film.

• Remove protective film within 45 days of installation to avoid glue residue on panel surface due to weathering.

• Do not apply PVC tapes, polyurethane sealant or silicone sealant onto Alyclad protective film. The plasticiser contained in these materials
can penetrate the protective film and cause a gloss change in the coating.

• Do not apply spray paint or permanent marker to the film as the colour may penetrate the film and affect the panel.

SEQUENCE

As a rule, the sequence of installation is as follows:

1. Installation of the water membrane as per manufacturers requirements.

2. Installation of top hats, levelled and fixed as per wind loading requirements.

3. Alyclad panels fabricated and prepared for installation.

4. Installation of fabricated Alyclad panels, fixing through Z angles to top hats as per wind loading requirements.

5. Caulking applied to panel joints as per manufacturers requirements.

6. Removal of protective film within 45 days of installation.

7
ALYCLAD - TECHNICAL INFORMATION

Installation Details
A TYPICAL PANEL JOINT DETAIL

15 (TYP) Alyclad sealant


Alyclad 3mm panel
3mm

3mm
Factory panel rivet

Alyclad Z Angle Alyclad Z Angle


Cladding Zone

Isolation tape
Alyclad Tophat

Tek screw (TYP)


Moisture barrier as required

A HORIZONTAL JOINT DETAIL

Cladding Zone

3mm

Factory panel rivet

Alyclad 3mm panel Alyclad Z Angle

Alyclad sealant

Alyclad Tophat
15 (TYP)

Tek screw (TYP)

Isolation tape

Alyclad Z Angle

Moisture barrier as required

3mm

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

8
ALYCLAD - TECHNICAL INFORMATION

DETAIL SHOWING PANEL AT MASONRY WALL

Steel structure
Tek screw (TYP)

Moisture barrier as required Tek screw (TYP)

Alyclad Tophat
Isolation tape and
space washer as
required

Factory panel rivet


Alyclad sealant

Alyclad Z Angle
15 (TYP)

Alyclad 3mm panel

DETAIL AT SLAB JUNCTION - HEAD

Concrete structure

Tek screw (TYP) Drip Groove


Alyclad sealant
Isolation tape and space washer as required
15 (TYP)

Alyclad Z Angle

Factory panel rivet

Steel structure and fixing Alyclad Tophat


to engineers detail

Alyclad 3mm panel

Moisture barrier as required

3mm

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

9
ALYCLAD - TECHNICAL INFORMATION

DETAIL AT SLAB JUNCTION - BASE

3mm

Moisture barrier as required

Alyclad Tophat
Steel structure Alyclad Z Angle

Fixing to structure
to engineers detail

Alyclad 3mm panel

Factory panel rivet


Tek screw (TYP)

Zincalume flashing
10 nom

Concrete structure min 100 fall

DETAIL AT SOFFIT JUNCTION

Moisture barrier as required

Angle fixed to both


Alyclad 3mm panel tophats Tek screw (TYP)

Isolation tape Alyclad Tophat

Alyclad Z Angle
Alyclad Z Angle

Factory panel rivet

100 (TYP) 15 (TYP)


Alyclad sealant and backing rod

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

10
ALYCLAD - TECHNICAL INFORMATION

WALL ABUTMENT DETAIL

Tek screw (TYP)

Alyclad angle
Moisture barrier as required

Alyclad Tophat

Alyclad sealant and backing rod


Tek screw (TYP)

Isolation tape

Factory panel rivet

Alyclad 3mm panel

EXTERNAL CORNER DETAIL

Fixing to structure
to engineers detail

Steel structure

Moisture barrier as required

Alyclad 3mm panel

Lines of cassette
system below
Alyclad Tophat

Tek screw (TYP)

Isolation tape

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

11
ALYCLAD - TECHNICAL INFORMATION

INTERNAL CORNER DETAIL

Moisture barrier as required

Alyclad Tophat

Fixing to structure
to engineers detail

Steel structure

Alyclad 3mm panel

Isolation tape

WINDOW SILL DETAIL

Window sill

Alyclad sealant
and backing rod
Steel structure and
fixing to engineers detail

Alyclad Z Angle
Tek screw (TYP)
Isolation tape

Alyclad 3mm panel

Moisture barrier as required

Alyclad Tophat

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

12
ALYCLAD - TECHNICAL INFORMATION

WINDOW HEAD DETAIL/DOOR FRAME DETAIL

Alyclad Tophat
Alyclad Z Angle
Moisture barrier as required

Alyclad 3mm panel

Factory panel rivet


Tek screw (TYP)

Sealant and backing rod

Isolation tape and spacer


Window subhead washer as required

Window head

PARAPET CAPPING DETAIL

Alyclad Z Angle

Optional fixing by
Factory panel rivet
Tek screw

Sealant and backing rod


Alyclad tape
Isolation tape
Low modulus silicone
Moisture barrier as required
Alyclad 3mm panel

Parapet lining

Alyclad Tophat

DISCLAIMER

These details are limited to the generalized design specification for Alyclad, and are intended for use by a technically skilled person only. Use of the same is at their own discretion and risk.

13
ALYCLAD - TECHNICAL INFORMATION

Fabrication Details
FABRICATION CONSIDERATIONS

CUTTING

Alyclad can be cut with a wall-saw, circular saw, bandsaw or jigsaw. The requirements for a circular saw are identical
to that for cutting solid aluminium.

TOOLING (CNC) 6.35mm Upspiral Cutter 1 or 2 flute

FEED/SPEEDS RPM: 18,000 / SPEED: 6-10 m/min

COMMENTS Clean panel edges if not all swarf is removed.

GROOVING

Grooving Alyclad is a simple and easy process, very similar to grooving traditional ACP.

TOOL (CNC) 90 degree V-groover with 2-3mm flat


7.40
FEED RPM: 18,000 / SPEED: 6-10 m/min
90o
2.20
3

DEPTH 0.8mm of core material should remain at base of groove

Clean panel edges if not all swarf is removed.


Take care not to overheat the blade. 3
COMMENTS
0.80

Groove on a flat, even surface to ensure depth accuracy


and consistency.

CONTOUR CUTTING

Alyclad panel can be contour cut with water jets, CNC routers, copy routers and jigsaws. Coolant is recommended
for router processing.

FOLDING

There must be between 0.7mm and 1mm of aluminium left at the base of the routed groove. Too much material
can cause stress and result in a larger radius fold than desired. It will also make folding the panel more difficult
and prevent the required fold angle from being obtained.

14
ALYCLAD - TECHNICAL INFORMATION

SHEARING

Shearing can be done with a guillotine. Ensure the blanking tools are padded. Shearing causes a slight roll down
along the cut edge of the panel.

PUNCHING

The punching of flat formed parts from Alyclad is performed in the same way as a solid aluminium sheeting, using sharp tools
and dies with minimal cutting clearance. Varying shapes may easily be punched with normal aluminium punching machinery.
As with shearing, a slight roll down may occur.

ROLL BENDING

Alyclad panel can be bent with a roll-bending machine. Use polished rollers free of imperfections only with a minimum radius
of 200mm.

SCREWING

Alyclad can be screwed with conventional stainless steel or galvanised screws for metal. For outdoor use,
allow for thermal expansion.

RIVETING

Riveting is possible with the usual equipment and solid rivets or blind rivets. For outdoor use allow for thermal expansion.

DRILLING

Alyclad panel can be drilled with centre point twist drills normally used for aluminium or machines common for metals.
Drill material: High-Speed Steel (HSS).

BENDING

Bending is possible with a folding table or brake press. The inside bending radius is roughly 5 times the Alyclad panel thickness.
Use protective foils. For serial production, tests should be made on sample panels.

15
ALYCLAD - TECHNICAL INFORMATION

Typical Warranty Details


WARRANTY CONSIDERATIONS

Alyclad is an incredibly durable material when used in the right application. When assessing an installation for warranty defects, unless given express written
authorization, check for the following:

• Less than a 50 pitch (risk of water pooling)

• Panels installed with directional arrows consistent (unless intentional)

• Maintenance schedule is documented and undertaken

Please contact your Wintec Systems representative for full terms and conditions.

KEEP YOUR WARRANTY FRESH

Maintaining your Alyclad finish is an important component to maintaining your warranty. Document each time you clean your Alyclad panels.
Cleaning frequencies are based on project location and are provided in the warranty.

RECOMMENDED CLEANING AGENTS

• Mineral spirits

• Organic cleaners

• PH-Neutral solvents

Miscellaneous
MANUFACTURING QUALITY

A dedication to the total fulfillment of our client’s and customer’s expectations is reflected by a complete quality control system, beginning at the point
of specification and continuing through to delivery of the guaranteed products.

All activities are carried out in a manner which:

• Uses the framework of ISO 9000 Quality Standards to verify the quality of our systems

• Ensures that our products and services are of the highest standards

• Create continuous improvements to our product through the application of the best quality practices.

ACCEPTABLE VARIATION

WIDTH ± 2.0mm

LENGTH ± 4.0mm

THICKNESS ±2%

BOW Maximum 0.5% of the length and/or width

SQUARENESS Maximum 5.0mm

The surface shall not have any irregularities such as dents, scratches
SURFACE DEFECTS
and other imperfections in accordance with our quality assurance.

16
ALYCLAD - TECHNICAL INFORMATION

HANDLING AND STORAGE

• Considerable care should be taken in the handling of Alyclad.

• Alyclad panels are sensitive to impact, particularly shocks from small, hard objects, which can dent the aluminium.

• A minimum of two people should be used when sliding large sheets to avoid scratching.

• To prevent surface damage when stacking Alyclad, there should be nothing between the panels.

• Alyclad should be stored in a cool and dry area where temperature is relatively stable.

• Pallets of Alyclad should be stored horizontally with adequate support to prevent sagging.

• Stacked pallets should be identically sized and not more than four (4) pallets high.

SUSTAINABILITY

Alyclad has been designed with an expected performance life of over 50 years. All Wintec Systems products have been developed with the health
of the environment, and the community, in mind.

As part of our commitment to use recyclable or reusable materials wherever possible, all Alyclad is 100% recyclable.

REPORT REGISTER

REPORT/REFERENCE
BCA 2019 VOL1 SECTION DESCRIPTION TEST/ASSESSMENT
NUMBER

C – Fire Resistance Combustibility AS 1530.1 RTF200074

F – Health and Amenity Weatherproofing FP.14 Contact Wintec Systems