Professional Documents
Culture Documents
18 135100 0000100595 Acm STR DRG 102514 - A
18 135100 0000100595 Acm STR DRG 102514 - A
LA
QIB
RB3
BARRIER AND
COUNTERBALANCE SLAB
E 400 THK
(BY SPECIALIST) 400 THK HIGH CONTAINMENT TL5
MSE WALL HEAD WALL TOP BARRIER
HEAD WALL CONCRETE BARRIER
MSE WALL
FRL
CJ CJ CJ CJ
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS. ALL COORDINATES AND LEVELS ARE IN
UP 3A UP 3B METER AND TO WGS84 ZONE 36 NORTH, AS PER THE PROJECT REQUIREMENTS.
2. THE DRAWING SHOULD BE READ IN CONJUNCTION WITH GENERAL NOTES AND
STANDARD DETAILS.
3. THE DETAIL SHOWN IN THIS DRAWINGS IS BASED ON THE AVAILABLE INFORMATION,
WHICH MAY BE MODIFIED UPON RECEIVING INFORMATION FROM OTHER
MIN. CLEARANCE
DISCIPLINES / DESIGNER.
4. THE DRAWINGS DEMONSTRATE A CONCEPT STRUCTURAL DESIGN UP TO DESIGN
MIN. CLEARANCE
FN01 FN02
STAGE 3A REQUIREMENTS. THE D&B CONTRACTOR IS TO DEVELOP THE FINAL
8000
C/L TRACK BRIDGE ARRANGEMENT BASED ON CHOSEN STRUCTURAL SYSTEM AND EXISTING
(FUTURE) SITE CONDITION IN COMPLIANCE WITH ALL NEOM PROCEDURES AND TECHNICAL
8000
SPECIFICATIONS.
1000 WIDE x 150 THK.
5. SPAN LENGTHS SHOWN ARE ALONG THE CENTERLINE OF THE ROAD ALIGNMENT.
REMOVABLE PRECAST
6. THE CONTRACTOR SHALL REFINE THE TYPICAL SECTION TO INCLUDE AN
D 1000 WIDE x 150 THK.
PLANK (TYP.)
ARCHITECTURAL FINISH TO THE APPROVAL OF NEOM. THIS MAY INCLUDE, BUT IS
1660 1940 3600 1660 1940 4000 3600 CIP KERBS (TYP.)
REMOVABLE PRECAST NOT LIMITED TO PROFILING OF CONCRETE ON WEB, FLANGES AND OTHER FACES,
(TYP.)
PLANK (TYP.) WALKWAY 400 CIP KERBS (TYP.) WALKWAY 400 INTRODUCTION OF BEVELS, ARCHITECTURAL PROFILING OF PIER HEADS AND OR
760
(TYP.) (TYP.) 200 THICK OTHER ITEMS.
200 THICK RC SLAB (TYP.) 7. THE SURFACE DRAINAGE FOR THE CROSSING UNDERPASS CAN BE FREELY
TOR TOR EGL
760
RC SLAB (TYP.) DISCHARGED DOWN TO THE RAMPS AND EVENTUALLY TOWARDS THE
SURROUNDINGS SINCE THE SPAN IS SHORT, PROVIDED WITH ADEQUATE
LONGITUDINAL AND CROSS SLOPES NO NECESSITY TO ADD A DRAINAGE SYSTEM.
EGL FURTHER DETAILS AND CALCULATIONS CAN BE PROVIDED AT LATER STAGES.
(MIN.)
2000
(MIN.)
2000
SLOPE SLOPE
SOIL SOIL SOIL SOIL
CJ FILL FILL CJ FILL FILL
CJ CJ
TOP OF
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
EMBANMENT
UNDERPASS DRAINAGE
1100 7200 1100 PIPES SYSTEM BELOW
THE MSE WALLS DESIGN STAGE:
1100 11200 1100
3A
ELEVATION
B 1 : 100
A
REV
FOR INFORMATION
DESCRIPTION
MC
APP
03/02/22
DATE
C PURPOSE OF ISSUE:
FOR INFORMATION
CLIENT: PROJECT MANAGEMENT CONSULTANT:
FRL
FRL
FILL
FILL
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):
1100
1100
CJ CJ CJ CJ
MIN. CLEARANCE
B DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:
WATER PROOFING
WATER PROOFING AS PER PROJECT DRAWN: I. HAI 03.02.22
AS PER PROJECT
8000
8000
SPECIFICATION
SPECIFICATION (TYP.) CHECKED: M.KHAN 03.02.22 CHECKED:
(TYP.)
C/L RAIL APPROVED: M.CUNNINGON 03.02.22 APPROVED:
1000 WIDE x 150 THK.
(FUTURE TRACK)
1000 WIDE x 150 THK. CIP KERBS (TYP.) REMOVABLE PRECAST 1660 1940 4000 3600 CIP KERBS (TYP.)
REMOVABLE PRECAST 1660 1940 3600 PLANK (TYP.) WALKWAY SCALE: AS SHOWN SHEET SIZE: A1 (841mm x 594mm)
(TYP.)
400
760
PLANK (TYP.) WALKWAY 400
(TYP.) (TYP.) 200 THICK DISCIPLINE NAME:
200 THICK
(TYP.)
RC SLAB (TYP.)
EGL
EGL
NICC CONNECTOR
(MIN)
2000
(MIN)
2000
2572
1100
SECTIONS)
7200 1100
(REFER EMBANKMENT NICC CIVILS SOUTH - NIC-00+000 TO NIC 75+000
SECTIONS)
18 135100 0000100595
07/02/2022 10:18:05 AM