DATA SHEET FOR DIFFERENTIAL PRESSURE

TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code
DATA SHEET FOR DIFFERENTIAL PRESSURE
OIL-100-ND-I-DS-0820 A0 Sheet No.: 02 of 05
TRANSMITTER

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code
DATA SHEET FOR DIFFERENTIAL PRESSURE
OIL-100-ND-I-DS-0820 A0 Sheet No: 03 of 06
TRANSMITTER

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT
NADUA Datasheet Number Rev Code

DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER OIL-100-ND-I-DS-0820 A0 Sheet No: 04 of 05

Notes:

1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weathe
proof certificate, Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indicating total level in mm & %.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All field transmitters shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal mode with superimposed
HART digital transmission signal for remote calibration and diagnostics from HART maintenance system.
6. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ
7. The housing of all transmitters shall be SS 316 minimum and suitable for aggressive offshore environment.
8. Certified plug shall be provided for spare cable entry.
9. All Transmitters shall be provided with SIL-2 (min) certification.
10. The over-range/static pressure protection of the transmitter shall be 130% of range.
11. Painting shall be Manufacturer standard suitable to all aggressive environment.
12. The design of electronic instruments shall be in compliance with the electromagnetic compatibility requirements as per IEC-61000-4.

Hold:
1. Design condition to be confirmed

REFERENCE DOCUMENTS:
17039-ND-I-DB-8001_Functional specification for package instruments_Rev C
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER SEE BELOW TABLE OIL-100-ND-I-DS-0820
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-ND-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 29-Nov-18 MV 29-Nov-18 PG 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
VS 29-Nov-18

UNITS: Pressure: kg/cm2 g Temp: ° C

GENERAL

1. MOUNTING REMOTE (2" PIPE MOUNTED) 8. ZERO SUPPRESSION REQUIRED


2. ACCURACY ± 0.25% OF SPAN 9. ZERO ELEVATION REQUIRED
3. OVER PRESSURE LIMIT * 10. ZERO ADJUST LOCATION EXTERNAL
4. AMBIENT TEMP. LIMIT 11 TO 34°C 11. SPAN ADJUST LOCATION EXTERNAL
5. OUTPUT 4-20 MADC, HART PROTOCOL WITH SMART TR. 12. ENCLOSURE RATING IP 65
6. POWER SUPPLY 24 VDC LOOP POWERED 13. AREA CLASSIFICATION ZONE 2, GAS GROUP IIA/IIB, T3
7. INDICATING YES, LCD IN ENGINEERING UNIT 14. EQUIPMENT CERTIFICATION EX 'IA'

CONSTRUCTION
1. SERVICE PRESSURE 11. HOUSING MATERIAL SS 316
2. PROCESS CONNECTION 1/2" NPT 12. XMTR DIAPHRAGM. MATERIAL N/A
3. ELECTRICAL CONNECTION 1/2" NPT(F) 13. O-RING MATERIAL GLASS-FILLED PTFE
4. MOUNTING BRACKET YES, FOR 2" PIPE 14. SENSOR FILL FLUID SILICONE OIL
5. PROCESS SEAL TYPE N/A 15. DIAPHRAGM SEAL MATERIAL N/A
6. HYDROTEST REQ'D NO 16. CAPILLARY MATERIAL N/A
7. DIAPHRAGM SEAL NO 17. DRAIN/VENT MATERIAL SS 316
8. CAPILLARY LENGTH N/A 18. FLANGE BOLT MATERIAL N/A
9. CAPILLARY FILL FLUID N/A 19. BRACKET BOLT MATERIAL SS 316
YES (1/4" DRAIN CONNECTION PIPE
10. DRAIN / VENT PLUG 20. SIL COMPLIANCE SIL-2
SUPPLIED WITH MANIFOLD) 21. MANUFACTURER *

NOTES
1) EACH INSTRUMENT SHALL INCLUDE A SS 316 TAG PERMANENTLY ATTACHED TO THE INSTRUMENT USING SS 316 SCREWS, SS 316 BOLTS OR SS 316 WIRE.
2) TRANSMITTER UN-USED CONDUIT ENTRY SHALL BE PLUGGED WITH CERTIFIED EX'D' PLUG.
3) PAINTING SHALL BE MANUFACTURER STANDARD SUITABLE FOR HAZARDOUS ENVIRONMENT.
4) DIFFERNTIAL PRESSURE TRANSMITTER SHALL BE PROVIDED WITH 5 VALVE MANIFOLD.
5) FOR GENERAL NOTES REFER NOTES SECTION.

INSTRUMENT OPERATING DESIGN OPERATIN DESIGN


CALIBRATED RANGE DENSITY SPECIFIC MODEL
S.NO. TAG NUMBER LOCATION / SERVICE P&ID NUMBER RANGE PRESSURE PRESSURE G TEMP. TEMP. REMARKS
IN KG/CM2 (KG/M3) GRAVITY NUMBER
IN KG/CM2 (KG/CM2) (KG/CM2) (°C) (°C)

ACROSS BASKET TYPE STRAINER


90
1 20-PDT-2000 (3"-PL-20-2402-AC01) / CRUDE 17039-ND-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 870 0.87 *
(HOLD 1)
OIL
ACROSS BASKET TYPE STRAINER
90
2 20-PDT-2001 (3"-PL-20-2403-AC01) / CRUDE 17039-ND-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 870 0.87 *
(HOLD 1)
OIL
ACROSS BASKET TYPE STRAINER
90
3 20-PDT-2002 (3"-PL-20-2404-AC01) / CRUDE 17039-ND-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 870 0.87 *
(HOLD 1)
OIL
ACROSS BASKET TYPE STRAINER
90
4 20-PDT-2003 (3"-PL-20-2405-AC01) / CRUDE 17039-ND-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 870 0.87 *
(HOLD 1)
OIL

* To be Provided By Vendor.