Professional Documents
Culture Documents
Extract From AXH1146 - UK - Ed02 - SIRZ (Samson Icarus Runner Zeus)
Extract From AXH1146 - UK - Ed02 - SIRZ (Samson Icarus Runner Zeus)
Extract From AXH1146 - UK - Ed02 - SIRZ (Samson Icarus Runner Zeus)
The errors of the anti-tipping device are displayed in place of the clock. The displayed message is of “Er: nn” type, where “Er” is
“error” and “nn” indicates the identification number (E.g. “ER:64”).
Alarm
Description What to do
code
11 CRC error of the memory zone containing the software Contact after-sales technical assistance
12 CRC error of the memory zone containing the parameters Contact after-sales technical assistance
13 Error of flow control of the program Contact after-sales technical assistance
14 Data exchange between the two micro controls error Contact after-sales technical assistance
Verify battery voltage with machine off and on is
15 Error out of scale power supply voltage +7Vdc, +18Vdc
within the indicated range.
Error internal power supply voltage of first out of scale
16 Contact after-sales technical assistance
channel 4.8 Vdc, 5.2Vdc
Error internal power supply voltage of second out of scale
17 Contact after-sales technical assistance
channel 4.8 Vdc, 5.2Vdc
21 Error of compatibility of the Cut Off1 output state Contact after-sales technical assistance
22 Error of compatibility of the Cut Off 2 output state Contact after-sales technical assistance
23 Error of compatibility of the WDO1 output state Contact after-sales technical assistance
24 Error of compatibility of the 1 output state Contact after-sales technical assistance
25 Error of compatibility of the 2 output state Contact after-sales technical assistance
26 Error of compatibility of the WDO2 output state Contact after-sales technical assistance
Load cell A:
31 Contact after-sales technical assistance
Error of CRC of the internal parameters of the load sensor.
Load cell A:
32 Contact after-sales technical assistance
Out of scale signal reading error (10-990)
Load cell A:
33 Contact after-sales technical assistance
Out of scale internal offset reading error (466-526)
Load cell A:
34 Contact after-sales technical assistance
Internal 5Vdc power supply voltage error
- CAUTION: - Read the SAFETY REGULATIONS (in this manual) carefully for the safety of all personnel and the machine. C/81
Mod. Samson - Icarus - Runner - Zeus Knowing and using the vehicle
Integrated devices
Alarm
Description What to do
code
Load cell A:
35 Contactafter-salestechnicalassistance
Thermal calibration not present error
Load cell A:
36 Contactafter-salestechnicalassistance
Check error on LIN bus message
Load cell A:
37 Contactafter-salestechnicalassistance
Error of CRC of transmitted data
Load cell A:
38 Contactafter-salestechnicalassistance
Error of LIN bus message receipt
Load cell A:
39 Contactafter-salestechnicalassistance
Error of LIN bus message control hour meter
Load cell B:
41 Contactafter-salestechnicalassistance
Error of CRC of the internal parameters of the load sensor
Load cell B:
42 Contactafter-salestechnicalassistance
Out of scale signal readings error (10-990)
Load cell B:
43 Contactafter-salestechnicalassistance
Out of scale internal offset reading error (526-586)
Load cell B:
44 Contactafter-salestechnicalassistance
Internal 5Vdc power supply voltage error
Load cell B:
45 Contactafter-salestechnicalassistance
Thermal calibration not present error
Load cell B:
46 Contactafter-salestechnicalassistance
Check error on LIN bus message
Load cell B:
47 Contactafter-salestechnicalassistance
Error of CRC of transmitted data
Load cell B:
48 Contactafter-salestechnicalassistance
Error of LIN bus message receipt
Load cell B:
49 Contactafter-salestechnicalassistance
LIN bus message control hour meter error
51 Difference too large between load cells A and B readings Carry out calibration test
52 Difference too large between load percentages detected by channel 1 and 2 Carry out calibration test
61 Error of double safety input compatibility for ground outriggers reading. Contactafter-salestechnicalassistance
62 Error of double safety input compatibility for closed boom reading. Contactafter-salestechnicalassistance
63 Error of mode selector inputs compatibility Contactafter-salestechnicalassistance
64 Error exclusion key input active upon ignition Contactafter-salestechnicalassistance
65 Error movements in block re-arm input active upon ignition. Contactafter-salestechnicalassistance
66 Error feedback signal reading in frequency Contactafter-salestechnicalassistance
67 Error feedback signal reading of the external actuator 1 Contactafter-salestechnicalassistance
68 Error feedback signal reading of the external actuator 2 Contactafter-salestechnicalassistance
71 Error analogical signal reading from out of scale joystick Contactafter-salestechnicalassistance
72 Error pressure transducer reading to verify re-arm with joystick Contactafter-salestechnicalassistance
73 Error CAN BUS messages receipt from optional external unit Contactafter-salestechnicalassistance
81 Error buttons pressed upon ignition Contactafter-salestechnicalassistance
C/82 - CAUTION: - Read the SAFETY REGULATIONS (in this manual) carefully for the safety of all personnel and the machine.