Extract From AXH1146 - UK - Ed02 - SIRZ (Samson Icarus Runner Zeus)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ANTI-TIPPING DEVICE ERRORS

The errors of the anti-tipping device are displayed in place of the clock. The displayed message is of “Er: nn” type, where “Er” is
“error” and “nn” indicates the identification number (E.g. “ER:64”).

Panel main errors

Alarm code Description


90 Hour meter message error (10FF80E3)
91 Hour meter message error (10FF80E3)
92 Hour meter message error (10FF80E3)
93 Hour meter message error (10FF80E3)
94 SARL reply error, different reply value
95 Calibration pin no longer connected during calibration
96 Errors inside the panel
97 Errors inside the panel
98 Errors inside the panel
99 Errors inside the panel

Alarm codes/system errors

Alarm
Description What to do
code
11 CRC error of the memory zone containing the software Contact after-sales technical assistance
12 CRC error of the memory zone containing the parameters Contact after-sales technical assistance
13 Error of flow control of the program Contact after-sales technical assistance
14 Data exchange between the two micro controls error Contact after-sales technical assistance
Verify battery voltage with machine off and on is
15 Error out of scale power supply voltage +7Vdc, +18Vdc
within the indicated range.
Error internal power supply voltage of first out of scale
16 Contact after-sales technical assistance
channel 4.8 Vdc, 5.2Vdc
Error internal power supply voltage of second out of scale
17 Contact after-sales technical assistance
channel 4.8 Vdc, 5.2Vdc
21 Error of compatibility of the Cut Off1 output state Contact after-sales technical assistance
22 Error of compatibility of the Cut Off 2 output state Contact after-sales technical assistance
23 Error of compatibility of the WDO1 output state Contact after-sales technical assistance
24 Error of compatibility of the 1 output state Contact after-sales technical assistance
25 Error of compatibility of the 2 output state Contact after-sales technical assistance
26 Error of compatibility of the WDO2 output state Contact after-sales technical assistance
Load cell A:
31 Contact after-sales technical assistance
Error of CRC of the internal parameters of the load sensor.
Load cell A:
32 Contact after-sales technical assistance
Out of scale signal reading error (10-990)
Load cell A:
33 Contact after-sales technical assistance
Out of scale internal offset reading error (466-526)
Load cell A:
34 Contact after-sales technical assistance
Internal 5Vdc power supply voltage error

- CAUTION: - Read the SAFETY REGULATIONS (in this manual) carefully for the safety of all personnel and the machine. C/81
Mod. Samson - Icarus - Runner - Zeus Knowing and using the vehicle
Integrated devices

Alarm
Description What to do
code
Load cell A:
35 Contactafter-salestechnicalassistance
Thermal calibration not present error
Load cell A:
36 Contactafter-salestechnicalassistance
Check error on LIN bus message
Load cell A:
37 Contactafter-salestechnicalassistance
Error of CRC of transmitted data
Load cell A:
38 Contactafter-salestechnicalassistance
Error of LIN bus message receipt
Load cell A:
39 Contactafter-salestechnicalassistance
Error of LIN bus message control hour meter
Load cell B:
41 Contactafter-salestechnicalassistance
Error of CRC of the internal parameters of the load sensor
Load cell B:
42 Contactafter-salestechnicalassistance
Out of scale signal readings error (10-990)
Load cell B:
43 Contactafter-salestechnicalassistance
Out of scale internal offset reading error (526-586)
Load cell B:
44 Contactafter-salestechnicalassistance
Internal 5Vdc power supply voltage error
Load cell B:
45 Contactafter-salestechnicalassistance
Thermal calibration not present error
Load cell B:
46 Contactafter-salestechnicalassistance
Check error on LIN bus message
Load cell B:
47 Contactafter-salestechnicalassistance
Error of CRC of transmitted data
Load cell B:
48 Contactafter-salestechnicalassistance
Error of LIN bus message receipt
Load cell B:
49 Contactafter-salestechnicalassistance
LIN bus message control hour meter error
51 Difference too large between load cells A and B readings Carry out calibration test
52 Difference too large between load percentages detected by channel 1 and 2 Carry out calibration test
61 Error of double safety input compatibility for ground outriggers reading. Contactafter-salestechnicalassistance
62 Error of double safety input compatibility for closed boom reading. Contactafter-salestechnicalassistance
63 Error of mode selector inputs compatibility Contactafter-salestechnicalassistance
64 Error exclusion key input active upon ignition Contactafter-salestechnicalassistance
65 Error movements in block re-arm input active upon ignition. Contactafter-salestechnicalassistance
66 Error feedback signal reading in frequency Contactafter-salestechnicalassistance
67 Error feedback signal reading of the external actuator 1 Contactafter-salestechnicalassistance
68 Error feedback signal reading of the external actuator 2 Contactafter-salestechnicalassistance
71 Error analogical signal reading from out of scale joystick Contactafter-salestechnicalassistance
72 Error pressure transducer reading to verify re-arm with joystick Contactafter-salestechnicalassistance
73 Error CAN BUS messages receipt from optional external unit Contactafter-salestechnicalassistance
81 Error buttons pressed upon ignition Contactafter-salestechnicalassistance

C/82 - CAUTION: - Read the SAFETY REGULATIONS (in this manual) carefully for the safety of all personnel and the machine.