Professional Documents
Culture Documents
MeterControl FLEXY Modular Smart Meters
MeterControl FLEXY Modular Smart Meters
FLEXY
FLEXY F2-T
FLEXY F2-M
Three-phase and single-phase modular meters
with replaceable communication modem
2DLM
Reg No: 0052
FLEXY are smart electronic meters for measurement of active, to keep pace with fast transitions and evolutions of communication
reactive and apparent electrical energy, with direct or CT connection technologies within meter lifetime and to choose a smart metering
to three-phase and single-phase networks. The new platform allows concept according to their needs. FLEXY series feature high level
the use of various communication technologies by easy replacement of security, wide range of measurement data much beyond classic
of communication modem. LTE NB IoT and CAT M1 communication billing data, and various interfaces toward smart home and other
technologies are supported, as well as G3-PLC in CENELEC A and external systems. FLEXY empower utilities with data necessary for
FCC frequency range and hybrid RF-PLC solution. This allows utilities successful handling of ongoing energy market transformation.
Key features
Measurement of electrical values (total and per phase) High level data security
Exchangeable communication modem IDIS2 interoperability
Replaceable real-time clock battery Fraud detection
Flexible tariff policy with up to 8 tariffs Load profiles
Two measurement principles including Ferraris method Power limit
suitable for prosumers Event logs
Two RS485 ports Measurement of energy quality
Support for In-Home Display with easy accessible RJ12 connector Firmware update
Variety of additional input/output options available on demand M-Bus port for G, W, H meters reading
(relays, pulse outputs, inputs and other) (optionally Wireless M-Bus)
Integrated switching device
DLMS/COSEM
MID certified
Technical data FLEXY
Measurements Inputs and outputs • Billing profile 2: recording billing limit value of power or current in
• Measurement of power and energy • Multiple configurations of 230 V, data in case of fraud detection with- dedicated meter registers
in both directions and absolute 5 A relays, low voltage and high out reset of maximum demand • Programmable Tolerance time and
values (A+, A-, |A|, R+, R-, R1, R2, R3, voltage inputs/outputs for different Penalty time
R4, S+, S- and by quadrants) functions, available according to Load profiles
• Ferrearis measurement method customer specification • 4 load profiles for measured values Code Red
suitable for prosumers (optional) • Exact configuration is defined with • 4 M-Bus profiles for registration of • Enables synchronous power limiting
• Measurement of energies, voltages customer according to specific or- measured data from other types of of groups (large number) of users in
and currents per phase, network der prior to manufacturing process measuring devices (multi-utility) case of irregular situation on distri-
frequency and power factor • Programmable and independent bution network (e.g. lack of power)
Communication options registration periods (5, 10, 15, 30,
Maximum demand • Communication module is ex- 60 minutes and 24 hours) Data security
• Programmable maximum demand changeable without removal of • High level data security including
integration period (typically 5, 10, metrology seals, which allows easy Log books authentication and data encryption
15, 30 or 60 minutes) replacement of communication • Standard log book (DLMS Security Suite 0 and 1)
module and adjustment to new • Fraud detection log book
Multi-rate registration and TOU communication technologies even • Disconnector control log book Firmware update
• Programmable tariff structure in years after meter installation • 4 M-Bus event logs which record • Firmware is separated to Metrolo-
(up to 8 tariffs) • Available communication options: events from other measuring devic- gy and Applicative part according
Cellular: GPRS/3G/LTE/NB IoT/CAT es connected to M-Bus port to Welmec 7.2, which allows safe
Internal real-time clock with DST M1 update of applicative part of the
• In accordance with IEC 62054-21 Power Line Communication: G3- Energy quality measurement firmware without need for addition-
• Automatic DST switching PLC in CENELEC A or FCC band • In accordance with EN 50160 al meter verification after firmware
• Backup battery supply • Hybrid RF+PLC communication • Voltage variation registration update
(replaceable battery) module (optional) • Outage registration (short outage – • Firmware update can be done local-
• RS485 port allows connection of the Event counter, long outage – Long ly and remotely with no impact on
Visual communication with meter meter to RS485 bus or local com- power interruption log) accuracy, parameter configuration
• Programmable selection of data and munication with external systems • Under-voltage and over-voltage or billing data
display sequence • RJ12 connector for communication measurement and registration in
• LED - configurable constant (1.000, with smart home systems (optional) Quality Event log book No-power reading (optional)
3.200, 10.000...imp/kWh/kvarh) • Local reading via display or via
Integrated switching module Fraud detection optical port in no power condition
Optical port (optional) • Detection of meter cover opening/ • Integrated battery supply
• Physical layer in accordance with • Bi-stable switching module placed closing
IEC 62056-21 under meter cover for remote or • Detection of terminal block cover Current terminal block
• Communication protocol - DLMS/ local connection/disconnection opening/closing • For current up to 100 А
COSEM mode C or mode E • Phase current break up to 100 A, • Detection of wrong authorization for • For all types of conductors up to
whilst neutral stays closed meter parameterization 35 mm2
M-Bus micro master port • In accordance with IEC 62055-31, UC3 • Detection of strong magnetic field
• Suitable for connection of gas, water • Minimum 10 000 mechanical dis- • Detection of strong EMF Compact meter case
or heat meters and in-home display connections/reconnections under • Detection of neutral conductor • Dimensions and fixing points in
• Physical layer in accordance with EN maximum load interruption accordance with DIN 43857
13757-2 (wired M-Bus), communica- • Measurement of neutral conductor • High quality, transparent, rein-
tion protocol EN 13757-2/3 Billing profiles current (optional) forced, self-extinguishing polycar-
• Optionally, Wireless M-Bus port is • Billing profile 1: recording billing bonate case
available data at the end of the programma- Power limiting • IP54 protection against water and
ble billing period with automatic • Power or current limiting of electri- dust (in accordance with IEC 60529)
reset of maximum demand. cal consumers by defining the
Accuracy Class
41,3
Reactive energy 2 or 3
Nominal and maximum current 5 (80) A (single-phase)
5 (100) A (three-phase)
72,5
160