Media Number -SENR6413-08 Publication Date -01/06/2008 Date Updated -05/06/2008
i02875901
The electronic systems monitor the operating parameters of the engine. The systems can initiate
responses if a specific parameter exceeds an acceptable range. The systems perform the following
functions:
If the engine is equipped with a Remote Control Panel (Status), the request for a shutdown is sent to the
Status Control Module (SCM). The SCM will terminate the flow of fuel. The SCM will also send a
request to the EIS control module in order to terminate the ignition.
If the engine is not equipped with a Remote Control Panel (Status), the request for a shutdown is sent to
the customer's equipment. The customer's equipment must terminate the fuel flow. The customer's
equipment must also send a request to the EIS control module in order to terminate the ignition.
2. If the engine is equipped with a Remote Control Panel (Status), the ECM sends a request for a
shutdown to the Status Control Module (SCM). The SCM sends a command to the EIS control
module in order to terminate the ignition. The SCM also stops the flow of fuel.
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 21/09/2009
G3516 Generator Set CSZ00001-UP(SEBP3374 - 29) - Document Structure Page 2 of 2
3. If the engine is not equipped with a Remote Control Panel (Status), the ECM sends a request for a
shutdown to the customer's equipment. The customer's equipment must terminate the fuel flow.
Additionally, the customer's equipment must send a request to the EIS control module in order to
terminate the ignition.
z Overspeed
z Overcrank
When one of the above faults occurs, the SCM sends a command to the gas shutoff valve in order to stop
the flow of fuel. If the engine does not shut down, the SCM sends a command to the EIS control module
in order to terminate the ignition.
When an emergency stop button is pressed, the SCM immediately sends commands in order to terminate
the fuel flow and the ignition.
For more information, refer to Systems Operation/Testing and Adjusting, SENR6420, "REMOTE
CONTROL PANEL (STATUS) G3500 & G3400 ENGINE ".