1. 1.00 m minimum roof eaves distance of two 30. 24.00 m maximum distance of travel when above one
dwelling units (more than 4 storeys) storey
2. 1.5 minimum distance of roof eaves between 31. 25% maximum corridor of an interior corridor
two dwelling units
32. 25% non residential shall not exceed from
3. 1.20 m maximum landing width; equal to run residential
4. 1.80 m minimum door clear height for mezzanine 33. .25 m maximum riser height
and bathroom
34. 25 years lifespan of indigeneous materials
5. 1.80 m maximim distance between landings
35. 36.00 sqm minimum floor area for multi family dwellin
required of ladder
units
6. 1 for every 20 minimum parking requirement
36. 38 mm minimum clearance of handrail to wall
units
37. 45.00 m maximum exit of travel
7. 1 light and 1 electrical requirements
conv. outlet 38. 50% mezzanine shall not cover the floor area in %

8. 1 over 20 window opening and floor area of bathroom 39. 50 sqm min. lot sizes rowhouse

9. 2.00 m minimum roof eaves distance of two 40. 60.00 m maximum exit of travel if there is fire
dwelling units (3-4 storeys) extinguisher

10. 2.00 m minimum door clear height 41. .60 m stairway clear width

11. 2.00 m headroom clearances 42. .60 m bathroom

12. 3.60 m maximum height between landings 43. .70 m service door/bedroom

13. 4.00 m Frontage minimum width of alley after 250m 44. .80 m exit width w/ occupant load of 50 or less
block 45. .80 m opening of main door
14. 4.00 m minimum distance between two dwelling 46. .80 m - 1.00 above the nosing or tread
units m
15. 4m Frontage rowhouse 47. .80 m - 1.20 handrail measurement
16. 4 steps maximum number of risers w/o handrail m

17. 4" thk 2 units abut each other is re required of 48. .90 m clear width of stair w/ 2 or more living units
fireblock 49. 100 sqm min. lot sizes single detached
18. 5 mm maximim variation in tread and risers 50. 150 mm minimum tread of winding stair from 300 mm
19. 6.00 m minimum distance between two dwelling side
units (3-4 storeys) 51. 150 sqm min. lot sizes duplex
20. 6.00 m minimum horizontal distance of two dwelling 52. 400 m Frontage maximum length of blocklength
units (more than 4 storeys)
53. ALLEY a public way intended to serve for pedestrians
21. 6m Frontage irregular lot and emergency vehicles
22. 8m Frontage Model C 54. BLOCK a parcel of land bounded on the sides by the
23. 10.00 m minimum distance between two dwelling streets or alleys o pathways
units (more than 4 storeys) 55. CLUSTER a single family attached dwelling containing 3
24. 10 hectares shall cover of each phase HOUSING or more separate living units

25. 10 m Frontage Model A and B 56. FIREBLOCK a wall w/c seperates two abutting living units
as to resist the spread of fire
26. 10 % opening window opening and floor area
57. FIREWALL a fireblock which extends vertically from the
27. 12 m maximum dead end corridors
lowest portion of the wall
28. 15% maximum allowable slope ramps with
58. one with 3.00 m width of stair
300mm changes in elevation
handrail
29. .20 m minimum tread width
59. one stairwell for 4 or more building storey in height w/ roof slope not greater than 1:3
60. PARTYWALL a wall jointly used by two parties under easements agreement
61. plus .15 m for every additional occupant load of 25
62. two handrails with 3.00 m-3.50 m stair width