Professional Documents
Culture Documents
FCU TRANE - Tehnicke Karakteristike - Gas Intela Kovin
FCU TRANE - Tehnicke Karakteristike - Gas Intela Kovin
FCU TRANE - Tehnicke Karakteristike - Gas Intela Kovin
Harmony FVAS fan coil units, version vertical casing, having the following technical
features:
Outer casing made with strong synthetic lateral corners and from galvanized and pre-painted front steel panel. The
plastic top grid has fixed louvres and is reversible in order to distribute the air in two different directions.
Inner casing made from 1 mm galvanized steel insulated with 3 mm polyolefin (PO) foam (class M1).
Coil manufactured from drawn copper tube and aluminium fins mechanically bonded onto the tube by an expansion
process. The coil has two 1/2inch BSP internal connections and 1/8 inch BSP air vent and drain. The connections are
on the left hand side facing the unit, on demand on the right and this change can also be easily carried out on site
during installation.
Condensate collection tray made from plastic (ABS UL94 HB) with an “L”-shaped plastic fitted on the inner casing. The
outside diameter of the condensate discharge pipe is 15mm.
The fans have aluminium or plastic blades directly keyed on the motor with double aspiration and they are dynamically
and statically balanced during manufacture in order to have an extremely quiet operation
The motor is wired for single phase and has six speeds, three of which are connected, with capacitor. The motor is fitted
on sealed for life bearings and is secured on anti-vibration and self-lubricating mountings. Internal thermal protection
with automatic reset, protection IP 20, class B.
Polypropylene cellular fabric regenerating filter with galvanized steel frame inserted into special plastic sliding guides
fastened to the internal structure for easy insertion and removal. Filter presence is highlighted by a plastic front cover
featuring the same colour as the top grid.
For further details, refer to our technical catalogue: Harmony fan Coil units, TRANE.
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Reference: FVAS43-2P
Version with coil for 2-pipe system, consisting of cooling section at 3 rows and heating section 3 row/rows.
UT 9066301T 3 speed control with electronic thermostat and manual summer/winter switch
Technical data
Speed: 1 3 5
Air flow m3/h: 415 590 760
Electric absorption W (E): 37 55 78
Noise power level Lw dB(A) (E): 37 46 52
Noise pressure level Lp dB(A): 28 37 43
(*) The sound pressure level applies to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
DIMENSION mm
LENGTH x WIDTH x HEIGHT 1224 530 225
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Water entering temperature °C: 60 60 60
Leaving water temperature °C: 40.0 40.0 40.0
Water flow l/s: 0.04 0.05 0.07
Total emission W (E): 3446 4562 5558
Water pressure drops kPa (E): 1.11 1.82 2.58
Leaving air temperature °C: 44.3 42.6 41.4
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Reference: FVAS44-2P
Version with coil for 2-pipe system, consisting of cooling section at 4 rows and heating section 4 row/rows.
UT 9066301T 3 speed control with electronic thermostat and manual summer/winter switch
Technical data
Speed: 1 3 5
Air flow m3/h: 415 590 760
Electric absorption W (E): 37 55 78
Noise power level Lw dB(A) (E): 37 46 52
Noise pressure level Lp dB(A): 28 37 43
(*) The sound pressure level applies to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
DIMENSION mm
LENGTH x WIDTH x HEIGHT 1224 530 225
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Water entering temperature °C: 60 60 60
Leaving water temperature °C: 40.0 40.0 40.0
Water flow l/s: 0.05 0.07 0.08
Total emission W (E): 4031 5402 6635
Water pressure drops kPa (E): 1.97 3.30 4.75
Leaving air temperature °C: 48.4 46.8 45.5
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Reference: FVAS61-2P
Version with coil for 2-pipe system, consisting of cooling section at 3 rows and heating section 3 row/rows.
UT 9066301T 3 speed control with electronic thermostat and manual summer/winter switch
Technical data
Speed: 1 3 5
Air flow m3/h: 510 815 1100
Electric absorption W (E): 47 81 116
Noise power level Lw dB(A) (E): 39 50 58
Noise pressure level Lp dB(A): 30 41 49
(*) The sound pressure level applies to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
DIMENSION mm
LENGTH x WIDTH x HEIGHT 1439 530 255
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
Water entering temperature °C: 60 60 60
Leaving water temperature °C: 40.0 40.0 40.0
Water flow l/s: 0.05 0.08 0.10
Total emission W (E): 4412 6440 8141
Water pressure drops kPa (E): 1.01 1.96 2.96
Leaving air temperature °C: 45.3 43.1 41.6
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com
(E) = Eurovent certified - Software Selection tool FCEASYSEL Rel. 1.3.5.0 30/06/2022
The certification of the software has to be verified in: http://www.eurovent-certification.com