710-20269-00A M-Series MVE Brochure Global EN - Web

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

2 M-Series MVE Soft Starter www.aucom.

com
Chemical / Petrochemical

Industry / Production
Water / Wastewater

Building technology

Marine / Off shore


Power generation

Wood processing
Cement / Stone
Pulp / Paper

Mining

Pump ¢ ¢ ¢ ¢ ¢ ¢ ¢
Fan/Blower/Aerator ¢ ¢ ¢ ¢ ¢ ¢ ¢
Compressor ¢ ¢ ¢ ¢ ¢
Chiller ¢ ¢ ¢ ¢
Refiner ¢ ¢
Extruder ¢
Centrifuge ¢ ¢
Mill crusher ¢ ¢ ¢
Hacker ¢ ¢
Conveyor ¢ ¢ ¢ ¢
Roller ¢ ¢
Rotating converter ¢ ¢ ¢ ¢
Bow thruster ¢
Main propulsion ¢
4 M-Series MVE Soft Starter www.aucom.com
Feature Benefit

Quick Application Setup Easy commissioning

Multi-language
Ease of use and communication
Graphical Display

Dual Motor Set Allows for two different starting and stopping motor data sets

Starting and Stopping A range of starting methods including current based torque control
Options make the MVE soft starter suitable for all applications
Fast and easy testing during installation and commissioning without
Simulation Mode
the need for a mains supply or motor
Real-time Performance Real-time graphs of motor performance and current quickly and clearly
Graph illustrate how your motor is performing
Recorded waveforms can help diagnose conditions interfering with
Diagnostic Tool
operation
AuCom IBT Interface Board Technology isolates the core starter control
LV/MV Isolation via IBT
system and HMI from the MV power section, creating a safer work
Technology
environment
Conduct factory testing without the need for a medium voltage motor
LV Motor Test
or supply
Secondary Injection Allows full testing of motor protections via an external system such as
Testing Omicron
A wide range of protection features including ground fault protection
Complete Motor
ensure that your equipment can operate safely even in the most
Protection
demanding environments

DOL+ Mode Protects your motor even while operating in bypass mode

Intelligent thermal modelling allows the soft starter to dynamically


Advanced Thermal
calculate motor temperature and determine whether the motor can
Modelling
start successfully
6 M-Series MVE Soft Starter www.aucom.com
Eq. ANSI
Description Built-in Protection
Code

Maximum start time Excess start time 48

Too many starts Restart delay and dynamic thermal model 66

Undercurrent Undercurrent 37

Overcurrent - jam
Instantaneous/time-delay overcurrent 50/51/51R
(Locked rotor, load increase)

Overcurrent - short (short circuit) Instantaneous/time-delay overcurrent (stage 2) 50/51

Checking or Interlocking relay Shorted SCR 3

Thermal overload Thermal overload - dynamic model 49/51

Current imbalance Current imbalance 46

Undervoltage Undervoltage 27

Overvoltage Overvoltage 59

Phase loss Phase loss 47

Phase sequence Phase sequence 47

Power loss Power loss 32

Ground fault Ground fault 50G

Mains frequency Frequency check, frequency variation 81

External communications failure Communications failure 85

Internal communications failure Internal failure 85

Ext. fault 1/code - 1 Auxiliary trip A 94/95

Ext. fault 2/code - 2 Auxiliary trip B 94/95

Motor overtemperature Thermistor protection* 23

Stator winding overtemperature Thermistor protection* 49

* RTD Relay is an optional extra.


8 M-Series MVE Soft Starter www.aucom.com
controller controller F1-3 controller controller

V sensing
V sensing V sensing V sensing
K1 K1 Q1
SST SST SST SST

3 3 3 3
20170.A

20167.A

20168.A

20169.A
M M M M

Q1 Q1
F1-3
Q1
K1 controller
controller
controller F1-3
K1
controller controller

K1 Q2
V sensing
V sensing Q2
K2 V sensing SST
SST
SST K2
V sensing V sensing

3 SST K2 SST Q3
3
3

3 3
20120.A
20171.A
13514.B

20172.A
13513.B

M M M M M

Controller controller Controller

F MV Fuses
V sensing
MVE soft starter with
MVE SST voltage sensing A

K Vacuum contactor

Q Vacuum circuit breaker


20209.A

Q Disconnecting switch
B C
3 3 current transformer

L Model Height (A) Width (B) Depth (C) (mm)


L Inrush current limiter
(mm) (mm) E1/E2 E3
C Capacitors
M-MVE-[70-540]-[V02-V06] 1240
2320 840 1240
M-MVE-[70-180]-V10 N/A
M-MVE-[200-540]-V10 2275 1190 1452 N/A

10 M-Series MVE Soft Starter www.aucom.com


M - MVE - X X X X - V X X - SC X X - E X - F X - L X - B X - PF X

Soft Motor Current Voltage


Start Protection Range Range

CSXi • • ≤ 200 A ≤ 575 VAC

EMX3 • • ≤ 2400 A ≤ 690 VAC

EMX4 • • ≤ 870 A ≤ 690 VAC

MVX • • ≤ 450 A ≤ 12 kV
12 M-Series MVE Soft Starter www.aucom.com
14 M-Series MVE Soft Starter www.aucom.com

You might also like