FW Main Module From 1 6 00 Rev 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

By Jindrich Smitka, 22.7.

2016

Firmware revisions of Main Module from 1.6.00, rev 2

1.6.00: 17.9.2014, used for serial Iveco production


- released Iveco configurations 50, 60, 61, 62 per initial specification

1.6.01: 16.10.2014, for testing purposes only


- added diagnostics of Eberspacher preheater for Iveco configurations
- added program 66 (standard 1000 with 100% FA and FH, FH pulsing valve on FH
module)
- added delayed winter clutch function (if ATS < Ab when winterclutch shall start, the
function will wait and start compressor as soon as ATS > Ab)

1.6.02: 21.10.2014, for internal TK testing purposes only


- first tests of indep. Driver’s AC Iveco, internal TK testing only

1.6.03: 11.11.2014, for TK test and Iveco test only


- first functional version of configuration 67 indep. Driver AC w/ Aerotherms
o corrected missing LPCO/HPCO alarms for conf. 67
o corrected permanently operating FB blower at switch off for conf. 67
o corrected freezing alarm for conf. 67
- corrected water pump activation in programs 35, 37, 43, 48, 66 using FH modules
with on/off water valves (always active water pump despite water valve status)
- first version of Iveco conf. 68, 69 (duct Hisp. Blowers off in 6H control phase)
- PULL DOWN separated from control phase 3, new parameters
PullDown On/PullDown OFF
- HEAT UP separated from control phase 6, new parameters HeatUP On/HeatUp OFF

1.6.04: 17.11.2014, for TK test and Iveco test only


- corrected mistake in conf. 63, 64, 68, 69 where opened door forced evap. blowers
to low speed also in 6H. Now blowers always off in 6H
- evaporator blower speed limits extended down to zero

1.6.05: 23.11.2014, for TK test and Iveco test only


- after road tests done by Iveco there is a new request to activate roof blowers in 6H
again in configurations 63, 64, 68, 69. Change reflected also to prg. 66

1.6.06: 10.12.2014, for TK test and Iveco test only


- after next Iveco road tests roof blowers disabled in 6H for conf. 63, 64, 68, 69,
change reflected also to prg. 66
- after next Iveco road tests roof blowers disabled in 7H for conf. 68, 69

Page 1 of 3
1.6.07: 14.1.2015, for serial production EXCEPT Iveco
- added winterclutch function for conf. 67 Iveco Indep. drv. AC
- modified conf. 67 algorithm
- added clutch off function 1 minute in 1 hour for conf. 67
- created Iveco conf. 65 based on approved features of conf. 67
- compressor cycling protection timer 36 sec added for conf. 65/67
- added prg. 70

1.6.08: 20.1.2015, for field tests only


- corrections on special prg. 58 (conf. 996)

1.6.09: 2.2.2015, for field tests only


- added prg. 71 (like 06, but blowers heat_min in 1H, 2H, 3H, 4H)
- roof blower prevention against short dropouts variant 1

1.6.10: 4.2.2015, for field tests only


- added roof blower prevention against short dropouts variant 2

1.6.11: 22.2.2015, for field tests only


- added program 72
- added new parameter ATS Cooling Disabled

1.6.12: 5.3.2015, for serial production


- added Delta T regulation (Iveco Top Cooling)

1.6.13: 11.3.2015, for field tests only


- added prg. 73

1.6.14: 19.4.2015, for serial production


- added prg. 74 (conf. 996, dual zone)
- reduced EEPROM writing of ATS, HTS values to 1 x 15 minutes

1.7.02: 25.8.2015
- optimisation of EEPROM writing
- correction of CO2 sensor control
- correction of prg. 59
- add SW filters of inputs and alarms
- add prg. 76

Drawing 1E49209 rev. E


------------------------------------------

Page 2 of 3
Drawing 1E49209 rev. F

1.7.03: 22.1.2016, service alarms sent for tests to Frigicoll and Graysons

- correction of PWM1 blockage at D+ OFF


- correction of slowly rising temperature sensor reading from minus temperatures,
causing sham alarms
- new accurate timer programmed
- service alarm function programmed. Device X1 > 32000h represents disabled
function, Device X1 < 32000h represents enabled function.

1.7.04: 16.2.2016, Bozankaya II


- created programs 87 and 88 for Bozankaya II Articulated with electrical heating.
- floor blowers excluded from Ht limit for prg. 87, 88 only
- floor blower low speed ventilation 30 seconds after floor blowers are deactivated
(to cool down electrical spirals). Function reflected to all the programs.

1.7.05: 14.3.2016
- floor blower low speed ventilation after floor blowers are deactivated extended
from 30 seconds to 120 seconds (Bozankaya II request)
- Iveco programs 60, 62, 64, 65, 69 with convector heating: floor water valve opening
during static preheater reduced from 100% water flow to 30% waterflow
- after D+ON -> D+OFF, boost pump remains enabled if HTS > +40°C. Prepared for
Iveco to utilize remaining waste heat by frontbox after engine is switched off.

1.7.06: 8.6.2016, Firmware released after Iveco validation


- floor blower low speed ventilation after floor blowers are deactivated – reduced
from 120 seconds to 0 seconds (1.7.06 not suitable for Bozankaya II).
- after D+ON -> D+OFF, boost pump remains enabled if HTS > +150°C. Function
„Utilize remaining waste heat by frontbox after engine is switched off“ disabled by
value +150°C per Iveco request.
- add program 91 (based on prg. 37, Plaxton damper implemented)
- add program 92 (based on prg. 37, 100% enabled for a possibility to reduce air
damper down to 50%)

Page 3 of 3