BlueDrive Propulsion
Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 1
BlueDrive Propulsion Catalogue 2020-06
OVERVIEW Page
1.1 Topology 03
1.2 Main Components 06
1.3 Standard Ratings 08
1
1.4 Standard Options 09
1.5 Request Options 10
DESCRIPTION Page
2.1 Rectifier 12
2.2 Inverter 14
2.3 HMI 15
2.4 Software 17 2
2.5 Cooling 20
2.6 Cubicle Design 22
2.7 Regulations 24
ARRANGEMENT
BlueDrive 560 – 1500kW DFE
Propulsion Converter 1900 – 2850kW DFE
560 – 1500kW 12/24 pulse
Catalogue 2020-06 1900 – 2850kW 12/24 pulse 3
3420 – 5700kW 12/24 pulse
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 2
BlueDrive Propulsion Catalogue 2020-06
1.1 Topology
BlueDrive
TOPOLOGY
DFE 12 pulse 24
AC MultiDrive system
Common DC Bus VFD’s (on request)
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 3
BlueDrive Propulsion Catalogue 2020-06
Mechanical construction
The frequency converter is mounted in our cubicle Local control panel
system 8PT. Standard degree of protection is IP22. Braking Unit (Option)
Other degrees of protection up to IP44 can be
delivered (standard options). The heat from the power losses is dissipated by a
closed water circuit. The water is conducted directly
The frequency converter consists of: through aluminum heat sinks in the rectifier and
Rectifier bridge(s) inverter unit.
Inverter(s)
Precharging system The unit is designed in accordance to relevant
Cooling system with heat exchanger unit instructions in IEC and classification societies.
Control electronics
Protection and monitoring facilities
Switches / isolators
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 4
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 5
BlueDrive Propulsion Catalogue 2020-06
1.2 MAIN COMPONENTS and a pump. As an option the unit can be delivered
with two alternating pumps for redundancy.
The cooling water circuit is monitored by the control
system.
AUX AUX
Supply Supply
Transformer AC DC Control system
The BlueDrive converter includes a “tailor-made”
control system based on a Simatic S7 PLC and the
control board CU320 for the Sinamics Motor Module,
Precharge
taking care of the special functions needed to obtain
a reliable operation and control of a propulsion drive
Aux
Control
system.
Control
signals Interface
Local
Operator
The Simatic PLC unit with its interface modules is
Panel used to obtain a potential free interface to other
Converter
control systems onboard. Standard interface is
Profinet. It can also communicate via Profibus.
The Simatic PLC is located in the control cubicle. The
interface signals are isolated from the converter
Motor
internal control.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 6
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 7
BlueDrive Propulsion Catalogue 2020-06
690V Bluedrive Single Propulsion Converter 690V Bluedrive Single Propulsion Converter
12 Pulse / Single Pump Cooling 24 Pulse / Dual Pump Cooling
CD-0560-IJ3000-BG0575-BA 560 kW CD-0560-IJ3000-BG0575-BA 560 kW
CD-0800-IJ3000-BE0810-BA 800 kW CD-0800-IJ3000-BE0810-BA 800 kW
CD-1000-IJ3000-BD1025-BA 1000 kW CD-1000-IJ3000-BD1025-BA 1000 kW
CD-1200-IJ3000-BC1270-BA 1200 kW CD-1200-IJ3000-BC1270-BA 1200 kW
CD-1500-IJ3000-BB1560-BA 1500 kW CD-1500-IJ3000-BB1560-BA 1500 kW
CD-1900-IJ3000-CD1947-DA 1900 kW CD-1900-IJ3000-CD1947-DA 1900 kW
CD-2250-IJ3000-CC2413-DA 2250 kW CD-2250-IJ3000-CC2413-DA 2250 kW
CD-2650-IJ3000-CB2750-DA 2650 kW CD-2650-IJ3000-CB2750-DA 2650 kW
CD-2850-IF6000-CB2964-DA 2850 kW CD-2850-IF6000-CB2964-DA 2850 kW
CD-3420-IF6000-DC3619-FA 3420 kW CD-3420-IF6000-DC3619-FA 3420 kW
CD-3800-IF6000-ED3895-HA 3800 kW CD-3800-IF6000-ED3895-HA 3800 kW
CD-4270-IF6000-DB4446-FA 4270 kW CD-4270-IF6000-DB4446-FA 4270 kW
CD-4560-IF6000-DC4826-HA 4560 kW CD-4560-IF6000-DC4826-HA 4560 kW
CD-5300-IF6000-EB5510-HA 5300 kW CD-5300-IF6000-EB5510-HA 5300 kW
CD-5300-ID6000-EB5510-HA 5300 kW CD-5700-ID9000-EB5928-HA 5700 kW
CD-5700-ID9000-EB5928-HA 5700 kW
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 8
BlueDrive Propulsion Catalogue 2020-06
z = G03 Closed bottom with MCT frame z = I09 Wire marking (not inside modules)
This option includes a MCT frame in the bottom This option include wiremarking in each end of the
for cable access. Filling modules are not included. control wire with ferrules or print sleeve indicating
connection terminal and number. Does not include
z = G04 Other RAL color marking of modules.
This option includes non standard color with RAL
code. Standard color is RAL7032 (light grey). z = J01 Profibus DP interface CP342-5
Color code to be specified. This option include Profibus DP connection to
control system. Standard is Profinett connection.
z = G05 Other NCS color
This option includes non standard color with NCS z = J02 Modbus interface CP341
code. Standard color is RAL7032 (light grey). This option include Modbus connection to control
Color code to be specified. system. Standard is Profinett connection.
z = H01 Counter flange for water connection. z = L01 Seaworthy packing in wooden crates
Standard connection for drives with This option includes packing in crates ready for
higher rating than 1500kW is two sea freight. Certified packing materials.
flanges with DN40PN10. This option
include counter flange with open pipe for
welding (diam. 40/44mm).
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 9
BlueDrive Propulsion Catalogue 2020-06
AFE System
Including Active Front End (AFE) rectifiers feeding
one or more inverters.
Input ACB
Air Circuit Breaker can be implemented in front of
the Rectifier if requested.
DC Switch
A DC switch can be used to isolate different drive
groups within a switchboard or between
switchboards. Depending on requirements
precharge functionality must be considered.
Output choke
Depending on motor requirements or cable length
output choke may be included between inverter
and motor.
Additional DC capacitors
Depending on Drive topology additional DC
capacitors may be added.
Output filter
Output filter may be included on specific drive
systems.
GPA circuits
Special circuits for system protection may be
implemented on request.
Modbus
Modbus signal interface can be implemented as a
request option.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 10
BlueDrive Propulsion Catalogue 2020-06
Aux voltage
690V
480V
450V
440V
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 11
BlueDrive Propulsion Catalogue 2020-06
Diode Rectifier
DESCRIPTION The rectifier system includes 6 pulse,12 pulse or 24
pulse diode bridges without fuses. The diodes are
2.1 RECTIFIER protected by Rectifier Protection Unit(RPU) and RC
protection.
Input section
ACB breaker
Input section can also be fitted with input ACB
breakers (Request Option). These breakers will be
motor operated and have overload protection.
Breaker size and short circuit level depend on
transformer rating.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 12
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 13
BlueDrive Propulsion Catalogue 2020-06
2.2 INVERTER
IGBT Inverter
The Sinamics water-cooled inverter drive is based on
the latest IGBT technology.
Main component in the inverter section are:
DC capacitor
IGBT’s with Snubber protection
Output current sensing
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 14
BlueDrive Propulsion Catalogue 2020-06
Inverter screen
Control screen
The control screen is accessed by clicking on the
“Control” button. The control screen allows the
operator to take control for local operation and then
control the converter. Motor screen
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 15
BlueDrive Propulsion Catalogue 2020-06
System screen
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 16
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 17
BlueDrive Propulsion Catalogue 2020-06
latter is used if there is no transformer between torque. In bollard condition the full torque will occur at
switchboard and converter. lower speed than in free run.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 18
BlueDrive Propulsion Catalogue 2020-06
Internal water cooling pumps (57,5 Hz by 60 Hz nominal frequency), all drives are
As a protection against insufficient cooling, or failures limited. If necessary, they will limit down to zero
in the cooling system, the DCS SW monitors both load to prevent the generators from being
cooling water flow and heat sink temperature. In overloaded.
addition the water level in the expansion tank is
monitored, and in case of a leakage, an alarm is Power Regulation
given. Modes of operation
The DCS SW may be parameterized for no pumps,
one pump or two pumps and with or without pump Speed reg. mode (RPM Mode):
load monitoring. In this mode the converter will try to keep the
For dual pump systems the pumps are alternated by propeller speed constant like the reference signal.
each start of the converter. When the converter is not This is the default regulation mode and is preferred
running, the pump(s) can be started and stopped for maneuvering and positioning.
from the touch-panel for testing.
DP mode:
External water cooling pumps This mode is made for control from Dynamic
The DCS SW may be parameterized for no pumps, Positioning (DP) and Joystick system. The propeller
one pump or two pumps. is speed controlled and always enabled. That means
For dual pump systems the pumps are alternated by that it does not need any “throttle zero” to start.
each start of the converter. When the converter is not Propellers for main propulsion are normally designed
running, the pump(s) can be started and stopped for full power at full speed forward. The DP
from the touch-panel for testing. mode are normally used when the ship is laying still
(bollard condition). Then the propeller can not
GPA use the drive full power because the drive is limited
Generator Power Adaptation (GPA) by its maximal torque. In bollard condition the
In the main switchboard, each generator is equipped full torque will occur at lower speed than in free run.
with a power transducer that generates a signal
proportional to the generator load. The signal from Power reg. mode:
the generator with the highest load is To obtain a stable generator load, the power
selected and sent to every propulsion converter on regulation mode is normally selected for use in
the vessel. When this signal exceeds the value transit.
corresponding to generator full load, all drives are With power control, the motor speed and torque can
limited. If necessary, they will limit down to zero load change freely within its maximal limits. This means
to prevent the generators from being overloaded. that speed and torque are continuously adapting
If there are faults in the load sharing between the themselves to obtain fixed power consumption
diesel engines that drives the generators, the according to the power reference given by the
converter drives will limit when the engine with the reference signal. This is important in heavy sea
highest load is at its maximum power. condition.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 19
BlueDrive Propulsion Catalogue 2020-06
2.5 COOLING
Water-Cooling Maintenance valves for redundant pumps make it
The Converter system (Rectifiers and Inverters) is possible to change pumps / motors during operation.
water-cooled. Either with open loop fresh water-
cooling (Request Option), closed loop fresh water- Automatic air relief valve for bleeding out of air
cooling system with primary fresh water (Standard), bubbles in the water.
or closed loop fresh water-cooling system with Strainer with bypass valve for possibility of cleaning
primary seawater (Request Option). during operation (option).
Expansion tank for reduction of pressure fluctuations
Closed loop water-cooling systems may be and water reservoir.
integrated in the converters, or as an individual skid. Temperature and pressure monitoring and indication.
Water filling and draining valves.
Double set of output pipes to the VFD line-up enable
disconnection of one half for convenient
maintenance.
External freshwater,
closed loop internal freshwater.
(standard solution)
A typical PID is shown beneath. The number of
Rectifiers, Choppers and Inverters may vary
depending on drive application. The PID show dual
pumps. Also single pump may be delivered.
Chopper
T10
P1 / M1
V101
V11 V12 V13
Inverter 1
P2/ M2
Inverter 3
V03 P03 V02 HX1 V01
cooling system.
External piping Minimum DN50 SS316.
Pressure at connection point 2,0 bar G at specified cooling-
water flow.
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 20
BlueDrive Propulsion Catalogue 2020-06
Piping will be of Stainless Steel or PP. Flanges will The design flexibility of integrated or stand-alone
be DN40/DN50 Metric (other as option) VFD elements will be maintained by the use of
dedicated choppers/resistors to every drive motor.
External freshwater directly from the vessel
(no heat exchanger in Converter) Chopper (Option)
(on request). The chopper unit is described earlier in this
Requirements to internal freshwater description. Please refer to this chapter.
• Free from oil, floating particles, glycol and
mineral salts. Braking Resistor (Request Option)
• With Antifrogen N (10% - 20%) Air-cooled or water-cooled braking resistors are built
• Max. particle size: ≤0.1 mm as separate units.
• pH-value: 6.0 – 8.0
• Amount of chlorides: <40ppm External resistor elements designed for 1070VDC
• Amount of sulphates: <50ppm
• Total amount of soluble matter: 340ppm
• Copper piping must be avoided
• Carbon Steel piping must be avoided
• PVC piping must be avoided
• Water inlet pressure: Max. 5 Bar
• Water Inlet temperature: +20°C - +45°C
• Strainer to be included externally (1,2mm)
External seawater,
closed loop internal freshwater
(on request).
Requirements to external seawater
• Free from oil and floating particles.
• Max. particle size: 0.5 mm
• Water Inlet temperature: +5°C - +38°C
• Water inlet pressure: Max. 5 Bar
• Strainer to be included externally (1,2mm)
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 21
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 22
BlueDrive Propulsion Catalogue 2020-06
- EN ISO 2813
Thickness: 75 +/- 25 µm
Salt fog test: 48 hrs. EN ISO 7253
Lattice cut: Gt-0. EN ISO 2409
Bending test: Ø 12 mm. EN ISO 1519
Hardnes: > 80. EN ISO 2815
Repair
In case of minor transportation damages, scratches
etc., a special mending lacquer is to be used:
12 ml: SWF 5.3720.1/0882, RAL 7032
1 litre: SWF5.3120.1/0687,RAL7032
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 23
BlueDrive Propulsion Catalogue 2020-06
2.7 REGULATIONS
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 24
BlueDrive Propulsion Catalogue 2020-06
ARRANGEMENTS
560kW / 800kW / 1000kW / 1200kW (DFE)
FRONT VIEW SIDE VIEW
Rectifier/ Inverter
Cool
Control Master
BlueDrive Propulsion
2150mm
1308mm 850mm
1500kW (DFE)
2150mm
1508mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 25
BlueDrive Propulsion Catalogue 2020-06
BlueDrive Propulsion
2150mm
1710mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 26
BlueDrive Propulsion Catalogue 2020-06
BlueDrive Propulsion
2150mm
1308mm 850mm
1500kW (12pulse)
2150mm
1508mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 27
BlueDrive Propulsion Catalogue 2020-06
BlueDrive Propulsion
2150mm
1710mm 850mm
2150mm
2110mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 28
BlueDrive Propulsion Catalogue 2020-06
3420kW (12pulse)
BlueDrive Propulsion
2150mm
2212mm 850mm
2150mm
2614mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 29
BlueDrive Propulsion Catalogue 2020-06
4270kW (12pulse)
BlueDrive Propulsion
2150mm
2812mm 850mm
5300kW (12pulse)
2150mm
3414mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 30
BlueDrive Propulsion Catalogue 2020-06
5300kW/5700kW (12pulse)
BlueDrive Propulsion
2150mm
4016mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 31
BlueDrive Propulsion Catalogue 2020-06
BlueDrive Propulsion
2150mm
1910mm 850mm
2150mm
2110mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 32
BlueDrive Propulsion Catalogue 2020-06
1900kW/2250kW (24pulse)
BlueDrive Propulsion
2150mm
2312mm 850mm
2150mm
2712mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 33
BlueDrive Propulsion Catalogue 2020-06
2850kW (24Pulse)
BlueDrive Propulsion
2150mm
2712mm 850mm
3420kW (24Pulse)
2150mm
2814mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 34
BlueDrive Propulsion Catalogue 2020-06
4270kW (24Pulse)
BlueDrive Propulsion
2150mm
3414mm 850mm
3800kW/4560kW (24Pulse)
2150mm
3216mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 35
BlueDrive Propulsion Catalogue 2020-06
5300kW/5700kW (24Pulse)
BlueDrive Propulsion
2150mm
4016mm 850mm
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 36
BlueDrive Propulsion Catalogue 2020-06
Confidential
This information is Generic and can be changed without prior notice. © Siemens Energy AS, SE O SO OF OMC. Page - 37