(((i))) Kockum Sonics

SUPERTYFQN® AT 150/200
~
with Valve Unit TV 784
. A high-power whistle according to IM
for vessels of 75 to 200 m in length

AT 150/200 Housing Complete


Ref. no. 24510052
Valve Unit
TV784
Ref. no. 24510043

• Horn AT 150/200
Ref. no. 32170883

Genera/Information
Before "COLREG 1972" (the International Regulations for
Preventing Collisions at Sea), a popular practice was to use Installation
low-pitched tones even for smaller vessels. In other words, SUPERTYFON AT 150/200 is to be fixed with four M16
the principle of a low tone for large vessels was not fol- bolts to an outrigger or similar construction. To avoid func-
lowed with sufficient stringency. tional trouble blow the supply pipe thoroughly clean be-
According to the IMO regulations. the very low tones are fore connecting to the signalling whistle. If the pipe line
strictly reserved for the largest ships. For middle-sized and above deck is longer than 100m, a primary FILTER TP
smaller vessels, there are rather wide limits as to the choice 15/2 should be installed at the. foot of the mast to protect
of frequencies. Preference has been given to signals which, the signalling apparatus from water condensate and rust
even at some distance, have capability to be heard. For particles. This filter is recommended to be drained regu-
vessels of75 to 200m, TYFON• and SUPERTYFON with larly, approximately once a month.
frequencies between 130 and 350 Hz are appropriate.
Technical Data
Positioning Whistles Frequency: 200 Hz
For an all-round radiation and a limited noise level from Sound Pressure Level (1m):
the ship's whistles at the listening posts, the positioning of Total: 148 dB
the ship's whistles is very important. For further informa- 1j3 octave IMO limit: 138 dB
tion regarding installation regulations and "Combined Sys- Air consumption: 20-30 ljs
tems", see our leaflet "IMO Regulations, KSM 265E".
Air supply pressure with choke regulation:
0,6-3 MPa (6-30 bar) (40 bar optional)
Valve Unit
Electric power:
The VALVE UNIT TV 784 has a good air flow section,
Thermostat heating: 24 W
thermostatic heating. exchangeable choke flanges and fil-
Valve: 8-15 W
ters. The apparatus is fitted with two coils for normal and
emergency operation and lanyard as standard (see sepa- Weight: 12,5 kg
rate leaflet KSM 264). rnr v.Jirino rii::.or.:ln"l" O::P.:> V::.IHP I lnit KSM 264.

Postal Address Address T~l€-phone

postbus 4226, 3006 AE


1 334E/9507
Kockum Sonics AB
annastraat 2, 3062 KA
Box 1035 Nat 040 -67 ROTTERDAM :es KSM 334Ej9109
S-212 10 MalmO, Sweden lndustrigatan 39 /nl+ 4640 'teti.Of0-4140411*
tax010-4114470 venteville bv
AT IS0/200: Spare Parts and Dimensions
985
785


(mm)

Air pipe 3 holes 12) 11


1~1~
182
~
View from beneath A-A

Spare Parts AT 150/200


No. Name Material Ref. no.
VALVE UNIT
1 Horn AT 150/200 Glass-fibre 32170883 TV784
reinf. polyester
2 Screw M6S 8 x 16 Stainl. steel 20801121
3 Diaphragm KM 150 AT Titan/ 21758006
campi. with 0-rings Nitrile rubber
4 Screw M6S 8 x 30 Stainl. steel 20801124
5 Choke flange Brass 21768201
(state pressure) 10
6 Filter Brass 32170418 Cable
7 Screw M6S 8 x 25 Stain!. steel 20801123 connection
8 Housing 150 AT Brass · 21754100
9 Packing 120/36 x 1 Nitrile rubber 37710245

1~ I ~=~~:~~ 80x39x1
Nitrile rubber 21765037
62 X 62 X 1
Nitrile rubber 37710278
Spare parts can be obtained from Kockum Sanies or their agents. Pipe thread 1;1"
When ordering, please, give working pressure, reference number
and part name.
Spare parts for valve unit, see Valve Unit TV 784, KSM 264. Air Pressure Choking
The basic condition for good performance and reliable
Pipe line dimensions function is the appropriate air pressure activating the
diaphragm.
Working pressure Length of pipe Inside diam. of
MPa (overpressure) metres pipe, mm (inches) When ordering, please state the working pressure. If the
below 2.0 Max. 150 Min. 25 (1 ")* connection pipe is dimensioned in accordance with the
1S0--350 Min. 32 (1 %')* recommendations (see table), the pressure gauge reading
above 2,0 Max. 150 Min. 19 (%")*
at the air receiver in the engine room is adequate for choice
150--350 Min. 25 (1")* of choke.

*Converting muff necessary for connection to signal apparatus. Subject to alteration without notice.
(((e))) Kockum Sonics Valve Unit TV 784
""
...for installation together with TYFON®
and SUPERTYFON® Whistles

.
... ,:
3

Valve Unit TV 784


230V 60Hz/24V DC
Ref. no. 24510043
Items
1 Three cable connections
Cable gland 0 9,5-12mm
2 2 Lanyard
3 Choked connections flange JZl62mm
4 Pipe thread for 1" filter (I.D.)
5 Pipe thread for 112'' filter (I.D.)

••• Genera/Information Technical Data


One ofthe most important parts assembled to a whistle Protection class: IP 65
is the valve. The new Valve Unit TV 784 designed for Mains operation: 230V AC, 50j60 Hz, 8/15W*
this purpose provides the following: Emergency operation: 24V DC 8j15W
Heating: 230V AC 25W*
• Good air flow section with low electric power con-
Working pressure: 0,3-3,0 MPa*
sumption.
(different chokes)
• Electric heating provided by a 25W element with ther- Air consumption: 8-100 ijs
mostat. (for different whistle types)
Dimensions: Box, 170 x 135 x 145 (L x D x H)
• Exchangeable flange choke for different pressures. Weight:: 3,6 kg
• Two solenoid coils for normal and emergency opera- *Other voltage and air pressure on request.
tion.
Note: To avoid functional trouble, blow the pipe line
• Lanyard for stand-by operation. thoroughly clean before connecting to valve.

Postal Address Address Telephone

Kockum Sanies AB postbus 4226, 3006 AE


1 264Ej9502
Box 1035 Nat 040-67 annastraat 2, 3062 KA
S-212 10 MalmO, Sweden lndustrigatan 39 lnt + 46 40 ROTTERDAM
es KSM 264E/8707
tel. 01o.414 04 11•
faxOI0-4114470 venteville bv
Units, Dimensions and Wiring Diagram
3 2

rm-.
r

f-
n
It-
I 16

t
1.,1. J. mounting holes
M8 065mm for fiange
' connection to whistle

10

~
(Q -180mm

• No. Name
Units
Material Ref. no.
Valve
Coil1
Valve
Coil2
Heater -:l
1 Heating complete incl.
element and thermostat
* 230V AC 25W 24510041
115V AC 25W 24510044 Thermostat
24V DC25W 24510045
2 Pilot valve campi. 24V DC 24510065
3 Pilot valve compl. 115V AC
* Pilot valve campi. 230V AC 24510064
*4 0-ring Rubber 20862062
*5 Piston campi. incl. spring Brass 39880149
6 0-ring Rubber 37690006
7 Spring Stainl. steel 20881000
8
9
Press pin
Screw M6S 6 x 20
Brass
Stain!. steel
Stainl. steel
21768198
20801113 T T
10 Spring campi. 24510042
Screw M6S 8 x 25 Stain!. steel 20801123 Operating Emergency Mains
11
12 0-ring Rubber 20862060 2 x 1,5mm 2 2 x 1,5mm2 3 x 1,5mm2
13 Screw MCSS 6 x 20 Stainl. steel 32621163
14 0-ring Rubber 37690018
15 Choke Flange** Brass 21768201
16 Packing 62 x 62 x 1mm Rubber camp. 21765037
Wiring diagram
17 Valve box for TV 784 campi. Plastic 21768199

Units can be Obtained from Kockum Sanies or their agents. When *Spare parts recommended to be kept on board.
ordering, please, giv_e voltage and working pressure, reference ** When ordering. please state what INOrking pressure and which
number and part name. type of whistle to be used.
(((e)))
:::'
Kockum Sonics Signal Controller Tl 56

Automatic Signal Controller


for whistle and lamp

Signal Controller Tl 56
Ref. no. 24500044

Genera/Information
Signal Controller Tl 56 is a robust, simple, inexpensive unit The automatics switch off in OFF/RESET position. They
which can be installed in all types of vessels. It is designed can also be switched off by pressing the push-button. The
for simultaneous sound and light signalling for one sound symbol switch should then be turned to the OFF/RESET
emitter and/or one lamp only. position.

>.
·.··.
Tl 56 cannot be controlled by external push-buttons, but
if external push-buttons are to be used, it is possible to
connect them directly to the sound emitter and/or lamp
(see wiring diagram over).
The indicating lamp extinguishes when the symbol switch
is in OFF/RESET position only indicating that the Signal
Controller is shut off.
It is also possible to change the symbol (whistle, lamp or
whistle plus lamp) during signalling by turning the symbol .,-_·
It must be noted that when the whistle is activated by the
switch direct to the required position. If the automatics
external push-button. the automatics will stop. however,
have been shut off via the hand push-button and the sym-
the external push-button for the lamp does not stop the
bol switch still being in the previous position, the automat-
automatics.
ics can be re-started with the same symbol by turning the
'.\
switch to the nearest position and then quickly back to the
Automatic Signalling previous position.
The automatics have five signal characters and an SOS sig-
nal for emergency use. All characters can be used for the ~anua/Signafling
whistle or the lamp or both simultaneously.
The push-button marked HAND is for manual signalling.
The interval between signals is always 90 seconds (between It shuts off an "automatic" signal even during signalling. A
SOS signals, 20 seconds). mains failure also shuts off the automatics.
The automatics start when the symbol switch is turned to If the switches are in the positions "OFF/RESET or SOS"
the required position even if the switch before starting is in then the hand push-button will activate the sound signal
the OFF/RESET position or at another symbol. only.

Postal Address Address Telephone


t77Ej9507
Kockum Sonics AB poslbus 4226, 3006 AE
Box 1035 Nat 040-671 8; annastraat 2, 3062 KA (SH 277E/9009
S-212 10 MalmO, Sweden tndustrigatan 39 lnt + 46 40 671 ROTIERDAM
tei.010.4140411'
fax 010-411 44 70 venteville bv
Signal Controller Tl 56 Dimensions

External push- .:..~ !f!


buttons i" 'i i ·1_
~------~·~~·~·~--~-ol+ ~
Technical Data + t

Voltage supply: r-'--L------_.j-H--o\+-P.-


Min: 10V DC. Max. 30V DC

Power consumption:
Note: max 3A
0.1A

Relay contactor:
Max. voltage: 32V
Max. current: 3A +
Min. 10VDC
Dimensions: Max. 30V DC
185 110 X 53 (L X H X D)


X
Wiring diagram
Weight:
0,5 kg Tl56

Units can be obtained from Kockum Sanies or their


agents. When ordering, please, give reference
number and part name.

Console mounting

SIGNAL CONTROLLER Tl 56 Hand push-button

• Switch for .signali+--"""""C~-:>.


characters
_..t----1'---Whistle

o--f--Indicating lamp

Symbol switch

4 screws

1-- -f-
to fasten
control-
\ ...
ler to ;
~~
0
mounting
I <b Hole for cable
0
::: ~ plate "'
"'
'
-~gJ
0

~
~ -f-
0
O<l 0

4 holes

I. 185
Rear view
.I 152.5
05mm
for mou n-
t1ng to
Rear view with mounting plate console
(included in delivery)

Subject to alteration without notice. (mm)