How to Update both Controller CF Card and HMI

Software

When it’s required to update both Controller and HMI projects, it will save some time if
the previously entered machine parameters are saved before update and restored when
the update is complete. The sequence is described in the following instructions:

1. On running 2Touch control system insert the memory stick into HMI USB slot, go
to the 2Touch screen 5.2 and push the BACKUP button to back up the
parameters to HMI USB.

2. Update the Controller CF Card image. Turn the 2Touch controls power OFF.
If you used the OPC Server PC, disconnect it’s both communication and power
supply - you don't need it any more.
Remove an old CF card from the Controller and insert the new one.

3. Power up 2Touch system, wait until it starts.


Leave the 2Touch components running for 10 minutes. (Within 10 minutes the
Controller will retrieve the parameters from HMI and copy it into its own memory)

4. Now you can update the HMI Firmware and Software.

5. Once the HMI project update is complete, and the HMI has started again,
go to the 2Touch screen 5.2 and push the RESTORE button to restore the
parameters from HMI USB.