Kingspan Kooltherm k3 Product Datasheet en Au
Kingspan Kooltherm k3 Product Datasheet en Au
K3 Floorboard
Insulation for Floors
Solid Residential Concrete Slab on Ground Residential Concrete Slab and Hydronic
Floor - Insulation below the Floor Slab Underfoor Heating on Ground Floor -
Insulation above the Floor Slab
Masonry Kingspan Kooltherm®
Cavity Wall K8 Cavity Board Kingspan Kooltherm® Masonry
K8 Cavity Board Cavity Wall
Kingspan Kooltherm®
K3 Floorboard
Concrete
Slab Concrete
Slab
Hydronic
Separation
Underfloor
Layer (e.g.
Heating
Polythene
Sheet)
Compacted Aggregate
Separation Layer Damp Proof
/ Sand Blinding
(e.g. Polythene Sheet) Membrane
Kingspan
Damp Proof Kooltherm® Compacted Aggregate Underfloor
Membrane K3 Floorboard / Sand Blinding Heating Pipes
Figure 1. Solid residential concrete slab on ground floor with Figure 2. Residential concrete slab with hydronic underfloor
Kooltherm® K3 Floorboard below the floor slab. heating on ground floor with Kooltherm® K3 Floorboard over the
floor slab.
Thermal Performance
Nominal Product Declared Product
Thickness R-value at 23ºC
25 mm R1.10
50 mm R2.30
2
Product Details
Product R-value
Nominal Product Declared Product
Thickness R-value at 23ºC
25 mm R1.10
50 mm R2.30
3
Product Details
Compressive AS 2498.3:1993 Typically exceeds 120 kPa at Water Use No water used in Kingspan Insulation’s
Stress (Insulant) 10% compression manufacturing process
Blowing Agent Manufactured with a blowing agent that
Water Vapour ASTM E96 > 35 MN.s/g has zero ODP and low GWP
Transmission Part B - 2016
Fire Performance
Test Test Method Result
4
Installation Instructions
Subsoil
5. Kingspan Kooltherm K3 Floorboard should not be
®
5
Other Information
Packaging
According to quantity, the boards are supplied in packs,
labelled and shrink-wrapped in polythene.
Resistance to Solvents
The insulation core is resistant to short–term contact with
petrol and with most dilute acids, alkalis and mineral oils.
However, it is recommended that any spills be cleaned
off fully before the boards are installed. Ensure that safe
methods of cleaning are used, as recommended by suppliers
of the spilt liquid. The insulation core is not resistant to
some solvent-based adhesive systems, particularly those
containing methyl ethyl ketone. Adhesives containing such
solvents should not be used in association with this product.
Damaged boards or boards that have been in contact with
harsh solvents or acids should not be used.
6
Contact Details
Australia
Kingspan Insulation Pty Ltd
T: 1300 247 235
E: info@kingspaninsulation.com.au
www.kingspaninsulation.com.au
® Kingspan, Kooltherm, KoolDuct, Air-Cell, GreenGuard, Thermakraft and the Lion Device are Registered Trademarks
of the Kingspan Group plc in Australia and other countries. All rights reserved. © Kingspan Insulation Pty Ltd.
Kingspan Insulation Pty Ltd reserves the right to amend product specifications without prior notice.
The information, technical details and fixing instructions etc. included in this literature are given in good faith and
apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual
requirements, specifications and any applicable laws and regulations. For other applications or conditions of use,
Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan
Insulation products that are not specifically described herein. Please check that your copy of the literature is current
by contacting us or visiting https://www.kingspan.com/au/en/products/insulation/floor-insulation/kooltherm-k3-